Search NASA⌕ Search

SEARCH · Search NASA

Results for “ANEMOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Turbulence measurements in the compressor exit flow of a General Electric CF6-50 engine

Ruggedized cooled film probes were used to measure CF6-50 compressor exit turbulence properties at three different engine idle condition test points. The turbulence probe was coupled to a constant temperature anemometer and signal conditioning system. An on-line readout system connected to the anemometer was used to check the data as it was acquired. At engine idle conditions, the turbulence intensity ranged from 4.8 percent to 5.6 percent and the length scale ranged from 5.64 cm to 6.95 cm. The length scale values are somewhat larger than the passage height at the measurement plane (5.54 cm), which indicates that the shape of the turbulent eddies are elongated in the axial direction. The microscale values range from about 0.73 cm to about 0.98 cm. Power spectral density distributions show that a large proportion of the turbulent energy at the measurement plane is concentrated at frequencies below one kilohertz.

Taylor, J. R.↗

Low-speed airspeed calibration data for a single-engine research-support aircraft

A standard service airspeed system on a single engine research support airplane was calibrated by the trailing anemometer method. The effects of flaps, power, sideslip, and lag were evaluated. The factory supplied airspeed calibrations were not sufficiently accurate for high accuracy flight research applications. The trailing anemometer airspeed calibration was conducted to provide the capability to use the research support airplane to perform pace aircraft airspeed calibrations.

Holmes, B. J.↗

Comparison between optical measurements and a numerical solution of the flow field within a transonic axial-flow compressor rotor

A comparison between numerical and experimental results is presented for the flowfield within a transonic axial-flow compressor rotor. The rotor was tested at design speed and a wide open throttle discharge condition. The relative tip Mach number was 1.4. A laser anemometer system was used to measure velocity and flow angle upstream, within, and downstream of the rotor. A holographic interferometer was used to visualize the rotor shock system near the tip. The computational procedure solves the full three-dimensional Euler equations using a time-marching technique. Shock location and shape determined from the two optical systems are compared. Calculated relative Mach number and flow angle contours, shock locations, and shock strength are compared to values measured with the laser anemometer.

Strazisar, A. J.↗

Effects of blade-vane ratio and rotor-stator spacing on fan noise with forward velocity

A research fan stage is acoustically tested in an anechoic wind tunnel with a 41 m/sec tunnel flow. Two stator vane numbers giving cut-on and cut-off conditions are tested at three rotor stator spacings ranging from 0.5 to 2.0 rotor chords. Hot-film anemometer turbulence measurements are made at the leading edge of the stator for each spacing, and a crossed film anemometer is radially transversed to define streamwise and upwash characteristics of the rotor blade wakes. Trends in the acoustic results are observed in the front and aft quadrants at 80% design fan speed. Aft quadrant results demonstrate a fundamental tone 9 dB lower for the 25 vane stator than for the 11 vane stator, while overtone levels are 3 dB higher. The cut-off criterion strongly controls fundamental tone level at all spacings, and spacing trends of the wake-defect upwash component show good agreement with corresponding cut-on acoustic tone levels.

Woodward, R. P.↗

Characterization of particles in the Langley 0.3 meter transonic cryogenic tunnel using hot wire anemometry

Hot wire anemometry was used to identify the nature of particles reportedly observed during free stream velocity measurements in the Langley 0.3-meter transonic cryogenic tunnel using a Laser Doppler Velocimeter. Since the heat-transfer process from the hot wire depends on the thermal conductivity and sticking capability of the particles, it was anticipated that the hot wire anemometer response would be affected differently upon impaction by liquid droplets and solid aerosols in the test gas stream. Based on the measured time response of the hot-wire anemometer in the cryogenic tunnel operated in the 0.3-0.8 Mach number range, it is concluded that the particles impacting the hot wire are liquid in nature rather than solid aerosols. It is further surmised that the liquid aerosols are unevaporated liquid nitrogen droplets used for cooling the tunnel test gas.

Singh, J. J.↗

The measurement of the synoptic scale wind over the ocean

The effects of mesoscale and microscale fluctuations of the winds on the determination of the synoptic scale wind are studied in order to show the effects of mesoscale variability on the verification of wind forecasts and on the comparison of remotely sensed and anemometer-averaged winds, and to show how to measure the synoptic wind scale more accurately. The frequencies involved correspond to periods longer than one hour and extend to the microscale. Nondimensional spectra that span both the mesoscale and the microscale are derived. Both conventional anemometer averages and remotely sensed winds contain a random component of the mesoscale wind in their values. These components are differences and not errors when winds are compared, and quantitative values for these differences are given. Ways of improving the measurement of the synoptic scale wind by transient ships, data buoys, and scatterometers on future spacecraft are described.

Pierson, W. J., Jr.↗

The structure of a separating turbulent boundary layer. V Frequency effects on periodic unsteady free-stream flows

The results of experimental trials to obtain measurements of the effects of frequency on the sinusoidal variations in the free stream velocity over a separating turbulent boundary layer are reported. An oscillation frequency of 0.596 Hz was examined, in conjunction with a free stream velocity of 10.18 m/sec. Hot-wire anemometers measured the velocity upstream of the separation and the phase-averaged skin friction, while the velocities in the detached flow zone and the downstream velocity were assayed with a laser anemometer. Large amplitude and phase variations developed at the beginning of separation, producing hysteresis in the relationships between flow parameters. Increases in the free stream velocity decreased the detached shear layer thickness, while in the deceleration segment of the cycle the separated shear layer grew thicker. The results are in a frequency range that are significant for axial compressor blades and helicopter blades.

Simpson, R. L.↗

Measuring the Liquid Content of a Gas

Instrument is adaptation of hot-wire anemometer. Hot-wire anemometer detects liquid droplets entrained in flowing gas. Droplets impinge on probe and carry away heat as vaporized. Power required to maintain probe at constant resistance and elevated temperature gives measure of amount of liquid present. Instrument used in steam turbines to check for condensation and detect fog at airports and highways, generating control signal to turn on fog lights.

Beekman, D. H.↗

Laser anemometry for hot section applications

Laser anemometers (LA's) for use in the study of the hot section components of turbomachinery are being developed. Specifically, laser anemometers are being developed for use in the 50.8-cm (20-in.) diameter warm turbine and high-pressure turbine (HPT) facilities at Lewis. A brief review of the status of the program along with some preliminary data taken in an open-jet burner are presented.

Seasholtz, R. G.↗

Uncertainties in hot-wire measurements of compressible turbulent flows implied by comparisons with laser-induced fluorescence

A hot-wire anemometer and a new nonintrusive laser-induced fluorescence (LIF) technique are used to survey a Mach 2 turbulent boundary layer. The hot-wire anemometer's ability to accurately measure mass flux, temperature, and density fluctuations in a compressible flow is examined by comparing its results with those obtained using LIF. Several methods of hot-wire calibration are used, and the uncertainties in their measurements of various fluctuating flow parameters are determined. The results show that although a hot-wire operated at high overheat can measure mass flux fluctuations, temperature and density fluctuations are not determined accurately from such measurements. However, a hot-wire operated at multiple overheats can be used to measure static and total temperature fluctuations. The presence of pressure fluctuations and their correlation with density can prevent the use of hot-wire data to determine density fluctuations.

Mckenzie, R. L.↗

Simultaneous measurements of temperature, density, and pressure in a supersonic turbulent flow using laser-induced fluorescence

A pulsed laser-induced fluorescence technique is described that provides simultaneous measurements of temperature, density, and pressure in low-temperature, turbulent flows. The measurements are made with spatial and temporal resolution comparable to that obtained with modern laser anemometer techniques used for turbulent boundary layer research. The capabilities of the method are briefly described and its demonstration in a simple two-dimensional turbulent boundary layer at Mach 2 is reported. The results are compared with conventional hot-wire anemometer data obtained in the same flow.

Mckenzie, R. L.↗

Development of buried wire gages for measurement of wall shear stress in Blastane experiments

Buried Wire Gages operated from a Constant Temperature Anemometer System are among the special types of instrumentation to be used in the Boundary Layer Apparatus for Subsonic and Transonic flow Affected by Noise Environment (BLASTANE). These Gages are of a new type and need to be adapted for specific applications. Methods were developed to fabricate Gage inserts and mount those in the BLASTANE Instrumentation Plugs. A large number of Gages were prepared and operated from a Constant Temperature Anemometer System to derive some of the calibration constants for application to fluid-flow wall shear-stress measurements. The final stage of the calibration was defined, but could not be accomplished because of non-availability of a suitable flow simulating apparatus. This report provides a description of the Buried Wire Gage technique, an explanation of the method evolved for making proper Gages and the calibration constants, namely Temperature Coefficient of Resistance and Conduction Loss Factor.

Murthy, S. V.↗

Techniques used in the F-14 variable-sweep transition flight experiment

This paper discusses and evaluates the test measurement techniques used to determine the laminar-to-turbulent boundary layer transition location in the F-14 variable-sweep transition flight experiment (VSTFE). The main objective of the VSTFE was to determine the effects of wing sweep on the laminar-to-turbulent transition location at conditions representative of transport aircraft. Four methods were used to determine the transition location: (1) a hot-film anemometer system; (2) two boundary-layer rakes; (3) surface pitot tubes; and (4) liquid crystals for flow visualization. Of the four methods, the hot-film anemometer system was the most reliable indicator of transition.

Anderson, Bianca Trujillo↗

Corona anemometry for qualitative measurement of reversing surface flow with application to separation control by external excitation

An corona anemometer which detects gas flow by the displacement of an ion beam is described, and experiments are performed using the anemometer to investigate the active control of diffusor separation by periodic forcing. The apparatus is applied to the separated flow over a rearward facing ramp. An oscillating vane is attached to the surface near the separation point. It is suggested that the enhancement in turbulent energy produced by the oscillating vane is due to drastic modification of the wake shear flow, and not to vane-produced turbulence.

Durbin, P. A.↗

Model of hot-film sensor with substrate

A detailed model is constructed to investigate parameters influencing a hot-film anemometer system used to study cross-flow phenomena on swept wings. This anemometer is designed to detect vortices set up by cross-flow. The nature of the vortices is not well known, and a well-verified instrumentation model is considered essential to allow accurate interpretation of experimental results. Previous investigators have indicated that heat conduction to the film's substrate is significant. Two variations on the inclusion of substrate effects in the model are discussed. In the first, the substrate is assumed to have a constant temperature throughput: in the second more elaborate model, the temperature of the substrate is allowed to vary. This variation is related to the convective heat removal at the substrate/gas interface.

Mcree, Griffith J.↗

Techniques used in the F-14 variable-sweep transition flight experiment

This paper discusses and evaluates the test measurement techniques used to determine the laminar-to-turbulent boundary-layer transition location in the F-14 variable-sweep transition flight experiment (VSTFE). The main objective of the VSTFE was to determine the effects of wing sweep on the laminar-to-turbulent transition location at conditions representative of transport aircraft. Four methods were used to determine the transition location: (1) a hot-film anemometer system, (2) two boundary-layer rakes, (3) surface pitot tubes, and (4) liquid crystals for flow visualization. Of the four methods, the hot-film anemometer system was the most reliable indicator of transition.

Trujillo Anderson, Bianca↗

Accuracy Of Hot-Wire Anemometry In Supersonic Turbulence

Sensitivity of hot-wire probe compared to laser-induced-florescence measurements. Report discusses factors affecting readings of hot-wire anemometer in turbulent supersonic boundary layer. Presents theoretical analysis of responses of hot-wire probe to changes in flow; also compares measurements by hot-wire probe with measurements of same flows by laser-induced fluorescence (LIF). Because LIF provides spatially and temporally resolved data on temperature, density, and pressure, provides independent means to determine responses of hot-wire anemometers to these quantities.

Logan, Pamela↗

Laser anemometry: A status report

A laser anemometer system is being developed for the warm turbine facility as part of the HOST program. The system will be built using results obtained from the analytical and experimental research program. The status report of the laser anemometry applications research effort is presented. The designs for the turbine casing, the windows, and the positioning system were completed. A block diagram of the laser anemometer system, signal processing scheme, and computer system is given.

Wernet, Mark P.↗