Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerated Life Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

SU-F-J-47: Inherent Uncertainty in the Positional Shifts Determined by a Volumetric Cone Beam Imaging System

Purpose: To quantify inherent uncertainty associated with a volumetric imaging system in its determination of positional shifts. Methods: The study was performed on an Elekta Axesse™ linac’s XVI cone beam computed tomography (CBCT) system. A CT image data set of a Penta- Guide phantom was used as reference image by placing isocenter at the center of the phantom.The phantom was placed arbitrarily on the couch close to isocenter and CBCT images were obtained. The CBCT dataset was matched with the reference image using XVI software and the shifts were determined in 6-dimensions. Without moving the phantom, this process was repeated 20 times consecutively within 30 minutes on a single day. Mean shifts and their standard deviations in all 6-dimensions were determined for all the 20 instances of imaging. For any given day, the first set of shifts obtained was kept as reference and the deviations of the subsequent 19 sets from the reference set were scored. Mean differences and their standard deviations were determined. In this way, data were obtained for 30 consecutive working days. Results: Tabulating the mean deviations and their standard deviations observed on each day for the 30 measurement days, systematic and random errors in the determination of shifts by XVI software were calculated. The systematic errors were found to be 0.03, 0.04 and 0.03 mm while random errors were 0.05, 0.06 and 0.06 mm in lateral, craniocaudal and anterio-posterior directions respectively. For rotational shifts, the systematic errors were 0.02°, 0.03° and 0.03° and random errors were 0.06°, 0.05° and 0.05° in pitch, roll and yaw directions respectively. Conclusion: The inherent uncertainties in every image guidance system should be assessed and baseline values established at the time of its commissioning. These shall be periodically tested as part of the QA protocol.

60 APPLIED LIFE SCIENCES↗

Durability of Pt-Alloy Catalyst for Heavy-Duty Polymer Electrolyte Fuel Cell Applications under Realistic Conditions

As an emerging technology, polymer electrolyte fuel cells (PEFCs) powered by clean hydrogen can be a great source of renewable power generation with flexible utilization because of high gravimetric energy density of hydrogen. To be used in real-life applications, PEFCs need to maintain their performance for long-term use under a wide range of conditions. Therefore, it's important to understand the degradation of the PEFC under protocols that are closely related to the catalyst lifetime. Alloying Pt with transitional metal improves catalyst activity. It is also crucial to understand Pt alloys degradation mechanisms to improve their durability. To study durability of Pt alloys, accelerated stress tests (ASTs) are performed on Pt-Co catalyst supported on two types of carbon. Two different AST protocols were being studied: Membrane Electrolyte Assembly (MEA) AST based on the protocol introduced by the Million Mile Fuel Cell Truck consortium in 2023 and Catalyst AST, adopted from the U.S. Department of Energy (DoE).

25 ENERGY STORAGE↗

AI-Batt (Autonomous Identification of Battery Life Models) [SWR 21-36]

Autonomous Identification of Battery Life Models (AI-Batt) AI-Batt is a MATLAB code base for developing lifetime models for batteries from accelerated aging data. The code base provides many functions for processing, visualizing, and modeling battery aging data, making the data processing, exploration, and modeling workflow substantially faster. These tools are tailored for working with battery aging data sets, which usually consist of many separate time-series for each cell, with many test conditions and possible replicates at each condition, which makes it difficult to simply process or visualize the data set. Complex modeling tasks, such as cross-validation, sensitivity analysis, and uncertainty quantification have been implemented to enable thorough statistical investigation of model predictions. Additionally, several machine-learning algorithms are implemented to autonomously identify suitable models via symbolic regression. Data processing functions automatically cast data from the struct data type, which is commonly used to store experimental data, but is not an acceptable input for most algorithms, to the table data type, which can be easily used as input to any optimization algorithm. Also, the data can be separated into time-invariant and time-variant data tables, which is helpful for exploring the data set as well as developing separate models for time-variant and time-invariant aging mechanisms. For example, in aging tests with constant temperature, temperature is a time-invariant experimental condition. Visualization tools enable plotting of data, model fits, and model simulations possible with single-line function calls, empowering data exploration of complex data sets with both time-varying and time-invariant trends. Plots can be automatically generated for the whole data set, or separated by data group (groups of test replicates) or individual data series. Data points or data series can be automatically colored by the value of a variable with a variety of color maps, and model predictions can also be colored by the value of a fit statistic. Comparisons between data sets and the predictions/simulations of different models on the same data set can be easily plotted as well. Distributions of parameter values from bootstrap resampling can be plotted to visualize the reliability of parameter estimation, or determine any correlations between parameters. Modeling tools handle the complex task of creating and parsing symbolic equations for modeling battery lifetime. Equations are parsed to grab relevant data variables, parameter values, or specified sub-models for input into optimization, evaluation, or simulation functions. Models can be optimized locally (one set of parameters for each data series), bi-level (some parameters shared across the data set), or globally (single set of parameters for all data). Functions implementing symbolic regression algorithms help users to discover effective model equations, even in poorly sampled, high-dimensional data.

Smith, Kandler↗

Institute for Clean Energy Technology Mississippi State University NSR&D Aged HEPA Filter Study Final Report

Data have demonstrated that filter media lose tensile strength and the ability to resist the effects of moisture as a function of age. Testing of new and aged filters needs to be conducted to correlate reduction of physical strength of HEPA media to the ability of filters to withstand upset conditions. Appendix C of the Nuclear Air Cleaning Handbook provides the basis for DOE’s HEPA filter service life guidance. However, this appendix also points out the variability of data, and it does not correlate performance of aged filters to degradation of media due to age. Funding awarded by NSR&D to initiate full-scale testing of aged HEPA filters addresses the issue of correlating media degradation due to age with testing of new and aged HEPA filters under a generic design basis event set of conditions. This funding has accelerated the process of describing this study via: (1) establishment of a Technical Working Group of all stakeholders, (2) development and approval of a test plan, (3) development of testing and autopsy procedures, (4) acquiring an initial set of aged filters, (5) testing the initial set of aged filters, and (6) developing the filter test report content for each filter tested. This funding was very timely and has moved the project forward by at least three years. Activities have been correlated with testing conducted under DOE-EM funding for evaluating performance envelopes for AG-1 Section FC Separator and Separatorless filters. This coordination allows correlation of results from the NSR&D Aged Filter Study with results from testing new filters of the Separator and Separatorless Filter Study. DOE-EM efforts have identified approximately 100 more filters of various ages that have been stored under Level B conditions. NSR&D funded work allows a time for rigorous review among subject matter experts before moving forward with development of the testing matrix that will be used for additional filters. The NSR&D data sets are extremely valuable in as much as establishing a selfimproving, NQA-1 program capable of advancing the service lifetime study of HEPA filters. The data and reports are available for careful and critical review by subject matter experts before the next set of filters is tested and can be found in the appendices of this final report. NSR&D funds have not only initiated the Aged HEPA Filter Study alluded to in Appendix C of the NACH, but have also enhanced the technical integrity and effectiveness of all of the follow-on testing for this long-term study.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SU-F-J-148: A Collapsed Cone Algorithm Can Be Used for Quality Assurance for Monaco Treatment Plans for the MR-Linac

Purpose: Treatment plans for the MR-linac, calculated in Monaco v5.19, include direct simulation of the effects of the 1.5T B{sub 0}-field. We tested the feasibility of using a collapsed-cone (CC) algorithm in Oncentra, which does not account for effects of the B{sub 0}-field, as a fast online, independent 3D check of dose calculations. Methods: Treatment plans for six patients were generated in Monaco with a 6 MV FFF beam and the B{sub 0}-field. All plans were recalculated with a CC model of the same beam. Plans for the same patients were also generated in Monaco without the B{sub 0}-field. The mean dose (Dmean) and doses to 10% (D10%) and 90% (D90%) of the volume were determined, as percentages of the prescribed dose, for target volumes and OARs in each calculated dose distribution. Student’s t-tests between paired parameters from Monaco plans and corresponding CC calculations were performed. Results: Figure 1 shows an example of the difference between dose distributions calculated in Monaco, with the B{sub 0}-field, and the CC algorithm. Figure 2 shows distributions of (absolute) difference between parameters for Monaco plans, with the B{sub 0}-field, and CC calculations. The Dmean and D90% values for the CTVs and PTVs were significantly different, but differences in dose distributions arose predominantly at the edges of the target volumes. Inclusion of the B{sub 0}-field had little effect on agreement of the Dmean values, as illustrated by Figure 3, nor on agreement of the D10% and D90% values. Conclusion: Dose distributions recalculated with a CC algorithm show good agreement with those calculated with Monaco, for plans both with and without the B{sub 0}-field, indicating that the CC algorithm could be used to check online treatment planning for the MRlinac. Agreement for a wider range of treatment sites, and the feasibility of using the γ-test as a simple pass/fail criterion, will be investigated.

60 APPLIED LIFE SCIENCES↗

AST Development for PEM Electrolyzers [Slides]

The ASTWG charter targets include: Develop ASTs to predict 80,000 hours of life in desired application; and Develop additional ASTs to evaluate different PEM electrolyzer components.

30 DIRECT ENERGY CONVERSION↗

Production of Actinium-225 via High Energy Proton Induced Spallation of Thorium-232

The science of cancer research is currently expanding its use of alpha particle emitting radioisotopes. Coupled with the discovery and proliferation of molecular species that seek out and attach to tumors, new therapy and diagnostics are being developed to enhance the treatment of cancer and other diseases. This latest technology is commonly referred to as Alpha Immunotherapy (AIT). Actinium-225/Bismuth-213 is a parent/daughter alpha-emitting radioisotope pair that is highly sought after because of the potential for treating numerous diseases and its ability to be chemically compatible with many known and widely used carrier molecules (such as monoclonal antibodies and proteins/peptides). Unfortunately, the worldwide supply of actinium-225 is limited to about 1,000mCi annually and most of that is currently spoken for, thus limiting the ability of this radioisotope pair to enter into research and subsequently clinical trials. The route proposed herein utilizes high energy protons to produce actinium-225 via spallation of a thorium-232 target. As part of previous R and D efforts carried out at Argonne National Laboratory recently in support of the proposed US FRIB facility, it was shown that a very effective production mechanism for actinium-225 is spallation of thorium-232 by high energy proton beams. The base-line simulation for the production rate of actinium-225 by this reaction mechanism is 8E12 atoms per second at 200 MeV proton beam energy with 50 g/cm2 thorium target and 100 kW beam power. An irradiation of one actinium-225 half-life (10 days) produces {approx}100 Ci of actinium-225. For a given beam current the reaction cross section increases slightly with energy to about 400 MeV and then decreases slightly for beam energies in the several GeV regime. The object of this effort is to refine the simulations at proton beam energies of 400 MeV and above up to about 8 GeV. Once completed, the simulations will be experimentally verified using 400 MeV and 8 GeV protons available at Fermi National Accelerator Laboratory. Targets will be processed at Argonne National Laboratory to separate and purify the actinium-225 that will subsequently be transferred to NorthStar laboratory facilities for product quality testing and comparison to the product quality of ORNL produced actinium-225, which is currently the industry standard. The test irradiations at FNAL will produce 1-20 mCi per day which is more than sufficient for quantitative evaluation of the proposed production process. The beneficial outcome of this effort will be a new production route for actinium-225 that does not use or require any uranium-233 materials owned by DOE or use any radium-226 as an irradiation target but can supply the medical community's needs for actinium-225 now and in the future.

07 ISOTOPE AND RADIATION SOURCES↗

Thermal / structural analysis of the HB 650 thermal shield

Fermilab’s PIP-II project’s superconducting linear accelerator will drive the next generation of particle accelerators through a revolution in beam intensity. Key to beam intensification are the high efficiencies of niobium-tin superconducting radiofrequency (SRF) cavities operating at cryogenic temperatures near 5 Kelvin. A multifaceted approach is employed to achieve and maintain the extreme temperature. Vacuum provides the first barrier to thermal convection. Physical thermal intercept zones further isolate the exterior shell vacuum vessel at 300 Kelvin from the supercooled beamline. The first thermal intercept lies just inside the exterior vacuum vessel forming the 40 Kelvin zone. This 40K thermal shield is the focus of this investigation. In preparation for operation, the thermal shield is cooled from 300K to 40K in a slow process over 2-1/2 days. The factors limiting the cooling rate are a high thermal gradient which produces thermal strain and high mechanical stress. D ecreasing the time required to reach operational temperatures is the desired research goal. Physical testing data and finite element method (FEM) computer models from the Single Spoke Resonator – 1 (SSR1) and Linac Coherent Light Source (LCLS-II) cryomodules will be evaluated to determine needed design changes. The thermal shield design for the High Beta 650 MHz (HB650) will be modified and analyzed using FEM computer models to determine maximum cooling rate with a target of 50 thermal cycles of life. Maximum allowable stress will be determined through low cycle fatigue calculations.

43 PARTICLE ACCELERATORS↗

Remote Monitoring and Evaluation of Damage at a Decommissioned Nuclear Facility Using Acoustic Emission

Reinforced concrete systems used in the construction of nuclear reactor buildings, spent fuel pools, and related nuclear facilities are subject to degradation over time. Corrosion of steel reinforcement and thermal cracking are potential degradation mechanisms that adversely affect durability. Remote monitoring of such degradation can be used to enable informed decision making for facility maintenance operations and projecting remaining service life. Acoustic emission (AE) monitoring has been successfully employed for the detection and evaluation of damage related to cracking and material degradation in laboratory settings. This paper describes the use of AE sensing systems for remote monitoring of active corrosion regions in a decommissioned reactor facility for a period of approximately one year. In parallel, a representative block was cut from a wall at a similar nuclear facility and monitored during an accelerated corrosion test in the laboratory. Electrochemical measurements were recorded periodically during the test to correlate AE activity to quantifiable corrosion measurements. The results of both investigations demonstrate the feasibility of using AE for corrosion damage detection and classification as well as its potential as a remote monitoring technique for structural condition assessment and prognosis of aging structures.

47 OTHER INSTRUMENTATION↗

Degradable Biocomposite Thermoplastic Polyurethanes

In this project, the team developed tough and degradable biocomposite thermoplastic polyurethanes (TPUs) by incorporating bacterial spores into TPUs as a biofunctional living filler. The team screened various bacteria and selected the Bacillus subtilis ATCC 6633 strain as the final candidate, primarily due to its genomic availability, sporulation ability and TPU assimilation activity. The heat-shock tolerance of ATCC 6633 spores was further improved through evolutionary engineering via Adaptive Laboratory Evolution (ALE), demonstrating a 17.7-fold enhanced germination efficiency post heat-shock treatment compared to the wild-type strain (WT). The team fabricated biocomposite TPUs by incorporating lyophilized powder of heat-shock tolerized (HST) spores during the hot melt extrusion (HME) of TPU at 135 °C. The baseline TPU used in this project is a commercially available soft-grade TPU (BCF45) manufactured by BASF. Colony forming unit (CFU) assays quantified that WT and HST spores in the TPU matrix retained approximately 20% and 100% survivability, respectively, after HME. Tensile testing demonstrated that the spores behaved as a polymer-reinforcing filler, positively affecting the overall tensile properties of the biocomposite TPU. For example, biocomposite TPU with WT and HST spores (BC TPU WT and BC TPU HST , respectively) exhibited up to 25% and 37% improved toughness, respectively, compared to TPU without spores. BC TPU HST showed remarkably improved disintegration in autoclaved compost (92% mass loss in 5 months), which simulated a microbially poor environment for TPU degradation. When compared to TPU without spores (44% mass loss in 5 months) the acceleration of degradation is marked. Respirometry confirmed that 72% of BC TPU HST was biomineralized into CO2 within 6 months, indicating that spores in the biocomposite TPU were germinated by utilizing nutrients in the autoclaved compost, facilitating TPU degradation at the end of the material's life. The team demonstrated the scale-up of biocomposite TPU fabrication using continuous extrusion and injection molding techniques. Processing conditions optimized in a lab-scale microcompounder were successfully transferred to a continuous extruder with a 30-fold increased throughput. Biocomposite TPUs prepared using these industry-relevant processes showed comparable toughness improvements to samples prepared in the lab-scale extruder. Excitingly, following compounding in the pilot-extruder the composite material could be injection molded, while retaining high spore viability and similar toughness improvements. The team also found that spores in biocomposite TPU served as antioxidants, preventing toughness decay during the recycled extrusion of BC TPU HST . Long-term storage tests over one year showed that the addition of spores had no negative effect on the longevity of the TPU. Furthermore, the team demonstrated the fabrication of spore-bearing biocomposite polymers with other polyesters such as PBAT, PLA, and PCL. We obtained promising preliminary data that showed overall toughness improvements for all polymers with spore addition. Finally, life cycle assessment (LCA) and techno-economic analysis (TEA) were carried out, which indicated minimal additional cost of fabrication. Overall, a tough and degradable biocomposite thermoplastic was successfully developed through this project, with all tasks completed successfully, achieving >100% of the objectives.

36 MATERIALS SCIENCE↗

TH-EF-BRB-10: Dosimetric Validation of a Trajectory Based Cranial SRS Treatment Technique On a Varian TrueBeam Linac

Purpose: This work investigates the dosimetric accuracy of a trajectory based delivery technique in which an optimized radiation beam is delivered along a Couch-Gantry trajectory that is formed by simultaneous rotation of the linac gantry and the treatment couch. Methods: Nine trajectory based cranial SRS treatment plans were created using in-house optimization software. The plans were calculated for delivery on the TrueBeam STx linac with 6MV photon beam. Dose optimization was performed along a user-defined trajectory using MLC modulation, dose rate modulation and jaw tracking. The pre-defined trajectory chosen for this study is formed by a couch rotation through its full range of 180 degrees while the gantry makes four partial arc sweeps which are 170 degrees each. For final dose calculation, the trajectory based plans were exported to the Varian Eclipse Treatment Planning System. The plans were calculated on a homogeneous cube phantom measuring 18.2×18.2×18.2 cm3 with the analytical anisotropic algorithm (AAA) using a 1mm3 calculation voxel. The plans were delivered on the TrueBeam linac via the developer’s mode. Point dose measurements were performed on 9 patients with the IBA CC01 mini-chamber with a sensitive volume of 0.01 cc. Gafchromic film measurements along the sagittal and coronal planes were performed on three of the 9 treatment plans. Point dose values were compared with ion chamber measurements. Gamma analysis comparing film measurement and AAA calculations was performed using FilmQA Pro. Results: The AAA calculations and measurements were in good agreement. The point dose difference between AAA and ion chamber measurements were within 2.2%. Gamma analysis test pass rates (2%, 2mm passing criteria) for the Gafchromic film measurements were >95%. Conclusion: We have successfully tested TrueBeam’s ability to deliver accurate trajectory based treatments involving simultaneous gantry and couch rotation with MLC and dose rate modulation along the trajectory.

60 APPLIED LIFE SCIENCES↗

A System-Level Model for Estimating Residual Strain and Life of Nuclear Reactor Coolant System Components Under Connected-System-Thermal–Mechanical Boundary Conditions

Background: Environmental-assisted fatigue (EAF) is a major issue for the long-term survival of nuclear power plant fleets in the U.S. and worldwide. Multi-material welded regions (e.g., nozzles) and other high-stress regions of reactor coolant system (RCS) components are prone to EAF-related damage. Objective: The discussed work describes a system-level finite element (FE) model of RCS components of a pressurized water reactor (PWR). This is with the goal of predicting the stress hotspots, strain residuals, strain amplitudes and the resulting fatigue lives. Methods: Herein, the FE model was developed considering system-level loading conditions (under connected system thermal-mechanical boundary conditions). Thermal-mechanical stress analysis was performed considering thermal stratification and a design-basis reactor loading cycle. Based on the FE model results, the strain residuals, strain amplitudes and resulting fatigue lives of RCS components were predicted. Results: The results show that some of the RCS components can have significantly different strain amplitudes, residual strain, and fatigue lives, despite having similar geometry and material. Higher residual strain can lead to accelerated cyclic hardening of material and the associated effect of EAF. The simulated component-level strain profile (under realistic multi-axial-multi-physics loading cycle) can guide the selection of appropriate test inputs for conducting laboratory-scale EAF tests, which is a focus of future works. Conclusions: Despite similar geometry and material the RCS component can have significantly different strain profiles and resulting fatigue lives. The discussed approach can help to identify and prioritize the RCS components for conducting expensive nondestructive evaluation (NDE) inspections.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-T-88: Comprehensive Automated Daily QA for Hypo- Fractionated Treatments

Purpose: The trend towards more SBRT treatments with fewer high dose fractions places increased importance on daily QA. Patient plan specific QA with 3%/3mm gamma analysis and daily output constancy checks may not be enough to guarantee the level of accuracy required for SBRT treatments. But increasing the already extensive amount of QA procedures that are required is a daunting proposition. We performed a feasibility study for more comprehensive automated daily QA that could improve the diagnostic capabilities of QA without increasing workload. Methods: We performed the study on a Siemens Artiste linear accelerator using the integrated flat panel EPID. We included square fields, a picket fence, overlap and representative IMRT fields to measure output, flatness, symmetry, beam center, and percent difference from the standard. We also imposed a set of machine errors: MLC leaf position, machine output, and beam steering to compare with the standard. Results: Daily output was consistent within +/− 1%. Change in steering current by 1.4% and 2.4% resulted in a 3.2% and 6.3% change in flatness. 1 and 2mm MLC leaf offset errors were visibly obvious in difference plots, but passed a 3%/3mm gamma analysis. A simple test of transmission in a picket fence can catch a leaf offset error of a single leaf by 1mm. The entire morning QA sequence is performed in less than 30 minutes and images are automatically analyzed. Conclusion: Automated QA procedures could be used to provide more comprehensive information about the machine with less time and human involvement. We have also shown that other simple tests are better able to catch MLC leaf position errors than a 3%/3mm gamma analysis commonly used for IMRT and modulated arc treatments. Finally, this information could be used to watch trends of the machine and predict problems before they lead to costly machine downtime.

60 APPLIED LIFE SCIENCES↗

TU-AB-303-12: Towards Inter and Intra Fraction Plan Adaptation for the MR-Linac

Purpose: To develop a new sequencer for IMRT that during treatment can account for anatomy changes provided by online and real-time MRI. This sequencer employs a novel inter and intra fraction scheme that converges to the prescribed dose without a final segment weight optimization (SWO) and enables immediate optimization and delivery of radiation adapted to the deformed anatomy. Methods: The sequencer is initially supplied with a voxel-based dose prescription and during the optimization iteratively generates segments that provide this prescribed dose. Every iteration selects the best segment for the current anatomy state, calculates the dose it will deliver, warps it back to the reference prescription grid and subtracts it from the remaining prescribed dose. This process continues until a certain percentage of dose or a number of segments has been delivered. The anatomy changes that occur during treatment require that convergence is achieved without a final SWO. This is resolved by adding the difference between the prescribed and delivered dose up to this fraction to the prescription of the subsequent fraction. This process is repeated for all fractions of the treatment. Results: Two breast cases were selected to stress test the pipeline by producing artificial inter and intra fraction anatomy deformations using a combination of incrementally applied rigid transformations. The dose convergence of the adaptive scheme over the entire treatment, relative to the prescribed dose, was on average 8.6% higher than the static plans delivered to the respective deformed anatomies and only 1.6% less than the static segment weighted plans on the static anatomy. Conclusion: This new adaptive sequencing strategy enables dose convergence without the need of SWO while adapting the plan to intermediate anatomies, which is a prerequisite for online plan adaptation. We are now testing our pipeline on prostate cases using clinical anatomy deformation data from our department. This work is financially supported by Elekta AB, Stockholm, Sweden.

60 APPLIED LIFE SCIENCES↗

Total skin electron therapy (TSET): A reimplementation using radiochromic films and IAEA TRS-398 code of practice

Purpose: The aim of this work is to present an updated implementation of total skin electron therapy (TSET) using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films. The optimization of quality control tests is also included. Methods: A Varian 2100 C/D linear accelerator equipped with the special procedure HDTSe{sup -} (high dose rate total skin electron mode, E=6 MeV) was employed to perform TSET irradiations using the modified Stanford technique. The commissioning was performed following the AAPM report 23 recommendations. In particular, for dual-field beams irradiation, the optimal tilt angle was investigated and the dose distribution in the treatment plane was measured. For a complete six dual-field beams irradiation, the treatment skin dose on the surface of a cylindrical phantom was evaluated by radiochromic films and the B factor which relates the single dual-field skin dose to the six dual-field skin dose was assessed. Since the TRS-398 reference conditions do not meet the requirements of TSET absolute dosimetry, GafChromic EBT films were also employed to check and validate the application of the protocol. Simplified procedures were studied to verify beam constancy in PMMA phantoms without the more difficult setup of total skin irradiation. Results: The optimized geometrical setup for dual-field beams was: Tilt angle={+-}19 deg., SSD=353 cm, and the beam degrader (200x100x1 cm{sup 3}) placed at 320 cm from the source. As regards to dose homogeneity in the treatment plane, for dual-field beams irradiation, the mean relative dose value was 97%{+-}5% (normalizing to 100% at the calibration point level). For six dual-field beams irradiation, the multiplication factor B was 2.63. In addition, beam quality, dose rate, and bremsstrahlung contribution were also suitable for TSET treatments. The TRS-398 code of practice was used for TSET dosimetry, as dose measurements performed by ionization chamber and radiochromic film agreed within 2.5%. Simplified quality control tests and baseline values were presented in order to check flatness, symmetry, and field size with radiochromic films and output and beam quality constancy with ionization chamber. Short-term reproducibility and MU linearity tests were also included. Conclusions: Commissioning parameters met the requirements of TSET treatments and the matching of AAPM guidelines with the IAEA code of practice was successful. Frequent beam performance controls can be easily performed through the presented quality assurance tests. Radiochromic dosimetry facilitated the TSET commissioning and played a major role to validate the application of TRS-398.

60 APPLIED LIFE SCIENCES↗

Lifelong cytomegalovirus and early‐LIFE irradiation synergistically potentiate age‐related defects in response to vaccination and infection

Abstract While whole‐body irradiation (WBI) can induce some hallmarks of immune aging, (re)activation of persistent microbial infection also occurs following WBI and may contribute to immune effects of WBI over the lifespan. To test this hypothesis in a model relevant to human immune aging, we examined separate and joint effects of lifelong latent murine cytomegalovirus (MCMV) and of early‐life WBI over the course of the lifespan. In late life, we then measured the response to a West Nile virus (WNV) live attenuated vaccine, and lethal WNV challenge subsequent to vaccination. We recently published that a single dose of non‐lethal WBI in youth, on its own, was not sufficient to accelerate aging of the murine immune system, despite widespread DNA damage and repopulation stress in hematopoietic cells. However, 4Gy sub‐lethal WBI caused manifest reactivation of MCMV. Following vaccination and challenge with WNV in the old age, MCMV‐infected animals experiencing 4Gy, but not lower, dose of sub‐lethal WBI in youth had reduced survival. By contrast, old irradiated mice lacking MCMV and MCMV‐infected, but not irradiated, mice were both protected to the same high level as the old non‐irradiated, uninfected controls. Analysis of the quality and quantity of anti‐WNV immunity showed that higher mortality in MCMV‐positive WBI mice correlated with increased levels of MCMV‐specific immune activation during WNV challenge. Moreover, we demonstrate that infection, including that by WNV, led to MCMV reactivation. Our data suggest that MCMV reactivation may be an important determinant of increased late‐life mortality following early‐life irradiation and late‐life acute infection.

59 BASIC BIOLOGICAL SCIENCES↗

ILC MARX MODULATOR DEVELOPMENT PROGRAM STATUS

A Marx-topology klystron modulator is under development for the International Linear Collider (ILC) project. It is envisioned as a lower cost, smaller footprint, and higher reliability alternative to the present, bouncer-topology, baseline design. The application requires 120 kV (+/-0.5%), 140 A, 1.6 ms pulses at a rate of 5 Hz. The Marx constructs the high voltage pulse by combining, in series, a number of lower voltage cells. The Marx employs solid state elements; IGBTs and diodes, to control the charge, discharge and disolation of the cells. Active compensation of the output is used to achieve the voltage regulation while minimizing the stored energy. The developmental testing of a first generation prototype, P1, has been completed. This modulator has been integrated into a test stand with a 10 MW L-band klystron, where each is undergoing life testing. Development of a second generation prototype, P2, is underway. The P2 is based on the P1 topology but incorporates an alternative cell configuration to increase redundancy and improve availability. Status updates for both prototypes are presented.

43 PARTICLE ACCELERATORS↗