Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Measurement of beam characteristics from C{sup 6+} laser ion source

We developed a C{sup 6+} laser ion source for a heavy-ion accelerator. A carbon target was irradiated with a Q-switched Nd:YAG laser (1064 nm wavelength, 1.4 J maximum laser energy, 10 ns pulse duration) to generate a high-density plasma. The laser ion source employed a rotating carbon target for continuous operation. Ion beams were extracted from the plasma through a drift space using a direct plasma injection scheme [B. Yu. Sharkov, A. V. Shumshurov, V. P. Dubenkow, O. B. Shamaev, and A. A. Golubev, Rev. Sci. Instrum. 63, 2841 (1992)] up to a maximum voltage of 40 kV. We measured the characteristics of the ion beams from the laser ion source and present the results of experiments here.

43 PARTICLE ACCELERATORS↗

Computational study of tungsten and depleted uranium photoneutron targets for a 20 MeV electron linear accelerator

Neutron production can be realized with a high energy electron linear accelerator by using Bremsstrahlung and photoneutron converters. In this study, Monte Carlo N-Particle Code (MCNP) was used to evaluate potential photonuclear target designs for a high energy electron linear accelerator for applications such as neutron radiography and neutron resonance spectroscopy. A computational model was developed to inform a target design that would yield a high number of neutrons. It consists of a 20 MeV electron beam incident on a Bremsstrahlung target and a photonuclear target to generate neutrons. This computational model showed that a thickness of 0.75 inches for both tungsten and depleted uranium yields the most neutrons from photoneutron reactions. Saturation in the total number of generated neutrons was observed at over 0.75-inch thickness for both evaluated materials. Depleted uranium yielded approximately twice the number of neutrons overall compared to tungsten. The highest neutron surface flux for Depleted Uranium was 1.06 × 10-4 neutrons/cm2/source electron, and for Tungsten it was 5.12 × 10-5 neutrons/cm2/source electron. The optimal target design for this study’s application would consist of a 0.75 inch-thick block of depleted uranium with the length, width, and/or diameter varying dependent on application.

43 PARTICLE ACCELERATORS↗

Electron acceleration through two successive electron beam driven wakefield acceleration stages

Structure based wakefield acceleration may provide a viable approach for accelerating sufficiently large numbers of electrons and positrons at the high gradient needed to meet the luminosity, efficiency, and cost requirements of a future linear collider. An important step in proving its viability is the demonstration of acceleration in multiple stages. Here we show the results of the first experimental demonstration of staged two beam wakefield acceleration, conducted at the Argonne Wakefield Accelerator Facility (AWA), in which a 0.5 nC electron bunch gained equal amounts of energy in two stages (~2.4 MeV per stage, corresponding to an average acceleration gradient of ~70 MeV/m). Meanwhile 150MeV/m of acceleration in a single stage has been achieved. The demonstration experiment should be scalable to staged-acceleration at gradients of the order of 200 to 300 MeV/m. Furthermore, such a development would considerably reduce both the cost and footprint of both a future high-energy physics (HEP) collider, as well as future X-ray light sources.

43 PARTICLE ACCELERATORS↗

Development of high-voltage pulse-slicer unit with variable pulse duration for pulse radiolysis system

A high-voltage pulse-slicer unit with variable pulse duration has been developed and integrated with a 7 MeV linear electron accelerator (LINAC) for pulse radiolysis investigation. The pulse-slicer unit provides switching voltage from 1 kV to 10 kV with rise time better than 5 ns. Two MOSFET based 10 kV switches were configured in differential mode to get variable duration pulses. The high-voltage pulse has been applied to the deflecting plates of the LINAC for slicing of electron beam of 2 {mu}s duration. The duration of the electron beam has been varied from 30 ns to 2 {mu}s with the optimized pulse amplitude of 7 kV to get corresponding radiation doses from 6 Gy to 167 Gy.

43 PARTICLE ACCELERATORS↗

FLUTE: A versatile linac-based THz source

A new compact versatile linear accelerator named FLUTE is currently being designed at the Karlsruhe Institute of Technology. This paper presents the status of this 42 MeV machine. It will be used to generate strong (several 100 MV/m) ultra-short ({approx}1 ps) THz pulses (up to {approx}4-25 THz) for photon science experiments, as well as to conduct a variety of accelerator studies. The latter range from comparing different coherent THz radiation generation schemes to compressing electron bunches and studying the electron beam stability. The bunch charge will cover a wide range ({approx}100 pC-3 nC). Later we plan to also produce ultra-short x-ray pulses from the electron bunches, which, for example, could then be combined for THz pump-x-ray probe experiments.

43 PARTICLE ACCELERATORS↗

Development of a novel bunch oscillation recorder with RFSoC technology

The SuperKEKB accelerator is designed to achieve unprecedented luminosity levels, but this goal is currently hindered by Sudden Beam Loss (SBL) events. These events not only obstruct luminosity improvement but also pose a significant risk to accelerator components, the Belle II detectors, and the superconducting focusing system, potentially leading to severe damage and quenching of the superconducting system. Here, to address this critical challenge, we have developed a novel Bunch Oscillation Recorder (BOR) based on RFSoC technology. The BOR has demonstrated high precision with a position resolution of 0.03 mm, making it a powerful tool for real-time beam monitoring. In its initial deployment, the BOR successfully recorded multiple SBL events, providing valuable data for further analysis. By strategically positioning BORs at the suspected points of SBL origin, we aim to directly identify sources of beam instability. We anticipate that this portable, high-speed BOR monitor will play a crucial role in resolving the SBL issue, ultimately helping achieve SuperKEKB's luminosity targets.

Beam diagnostics↗

First Principles Modeling of RFQ Cooling System and Resonant Frequency Responses for Fermilab’s PIP-II Injector Test

In this study we develop an a priori method for simulating dynamic resonant frequency and temperature responses in a radio frequency quadrupole (RFQ) and its associated water-based cooling system respectively. Our model provides a computationally efficient means to evaluate the transient response of the RFQ over a large range of system parameters. The model was constructed prior to the delivery of the PIP-II Injector Test RFQ and was used to aid in the design of the water-based cooling system, data acquisition system, and resonance control system. Now that the model has been validated with experimental data, it can confidently be used to aid in the design of future RFQ resonance controllers and their associated water-based cooling systems. Finally, without any empirical fitting, it has demonstrated the ability to predict absolute temperature and frequency changes to 11% accuracy on average, and relative changes to 7% accuracy.

43 PARTICLE ACCELERATORS↗

Characterization of fluid physics effects on cardiovascular response to microgravity (G-572)

The recognition and understanding of cardiovascular adaptation to spaceflight has experienced substantial advancement in the last several years. In-flight echocardiographic measurements of astronaut cardiac function on the Space Shuttle have documented a 15 percent reduction in both left ventricular volume index and stroke volume with a compensatory increase in heart rate to maintain cardiac output. To date, the reduced cardiac size and stroke volume have been presumed to be the consequence of the reduction in circulating fluid volume following diuresis and other physiological processes to reduce blood volume within a few days after orbital insertion. However, no specific mechanism for the reduced stroke volume has been elucidated. The following investigation proposes the use of a hydraulic model of the cardiovascular system to examine the possibility that the observed reduction in stroke volume may, in part, be related to fluid physics effects on heart function. The automated model is being prepared to fly as a GAS payload. The experimental apparatus consists of a pneumatically actuated, elliptical artificial ventricle connected to a closed-loop, hydraulic circuit with compliance and resistance elements to create physiologic pressure and flow conditions. The ventricle is instrumented with high-fidelity, acceleration-insensitive, catheter-tip pressure transducers (Millar Instruments) in the apex and base to determine the instantaneous ventricular pressures and (delta)P(sub LV) across the left ventricle (LVP(sub apex)-LVP(sub base). The ventricle is also instrumented with a flow probe and pressure transducers immediately upstream of the inflow valve and downstream of the outflow valve. The experiment will be microprocessor controlled with analog signals stored on the FM data tape recorder. By varying the circulating fluid volume, ventricular function can be determined for varying preload pressures with fixed afterload pressure. Pilot experiments on board the NASA KC-135 aircraft have demonstrated proof-of-concept and provided early support for the proposed hypothesis. A review of the pilot experiments and developmental progress on the GAS version of this experiment will be presented.

Pantalos, George M.↗

Using time of flight separation to observe photoneutron production by X-rays incident on beryllium - 25592

The neutron time-of-flight (nTOF) component of the Brazos experiment conducted at the Naval Research Laboratory using the Mercury accelerator observed the production of photoneutrons in a beryllium target bombarded by an approximate 5 MeV endpoint Bremsstrahlung x-ray source. Properly spaced and shielded plastic scintillators and quartz and sapphire radiators were able to measure time-separated scattered x-ray and neutron signals. Validated with simulations, the measured neutron signal is consistent with greater than 3x10{sup 9} total neutrons off the beryllium target. (authors)

43 PARTICLE ACCELERATORS↗

LEPS2: the second Laser-Electron Photon facility at SPring-8

A new project to construct the second beamline for the laser-electron photon beam at SPring-8 (LEPS2) has started. Based on the LEPS experience, the project aims to improve the intensity of the photon beam and to expand the detector acceptance by adopting the BNL-E949 detector, which is a hermetic detector in a large 1 T solenoid magnet. The central region of tracking chambers will be upgraded for the LEPS2. A new LEPS2 experimental building has just been constructed outside the experimental hall of the storage ring. The present status of the development of a frozen-spin polarized HD target is also reported.

43 PARTICLE ACCELERATORS↗

Modeling charge collection efficiency degradation in partially depleted GaAs photodiodes using the 1- and 2-carrier Hecht equations

Here, the Hecht equation can be used to model the nonlinear degradation of charge collection efficiency (CCE) in response to radiation-induced displacement damage in both fully and partially depleted GaAs photodiodes. CCE degradation is measured for laser-generated photocurrent as a function of fluence and bias in Al 0.3 Ga 0.7 As/GaAs/Al 0.25 Ga 0.75 As p-i-n photodiodes which have been irradiated with 12 MeV C and 7.5 MeV Si ions. CCE is observed to degrade more rapidly with fluence in partially depleted photodiodes than in fully depleted photodiodes. When the intrinsic GaAs layer is fully depleted, the 2-carrier Hecht equation describes CCE degradation as photogenerated electrons and holes recombine at defect sites created by radiation damage in the depletion region. If the GaAs layer is partially depleted, CCE degradation is more appropriately modeled as the sum of the 2-carrier Hecht equation applied to electrons and holes generated within the depletion region and the 1-carrier Hecht equation applied to minority carriers that diffuse from the field-free (non-depleted) region into the depletion region. Enhanced CCE degradation is attributed to holes that recombine within the field-free region of the partially depleted intrinsic GaAs layer before they can diffuse into the depletion region.

43 PARTICLE ACCELERATORS↗

Impedance Measurement of an Antenna with Hydrogen Plasma Driven by 13.56 MHz-rf for J-PARC H{sup -} ion source

In order to satisfy the Japan Proton Accelerator Research Complex (J-PARC) second stage requirements of an H{sup -} ion beam current of 50 mA and a life-time of 2000 hours, the development of a 13.56 MHz-rf-driven H{sup -} ion source was started by using an antenna developed at the Spallation Neutron Source (SNS). As the first step, the impedance of an antenna with hydrogen plasma, which is one of the most important parameters, was measured. For an rf-power of 0 kW, 1.25 kW or 7.45 kW, it was measured as j84.19+5.107 {Omega}, j80.22+11.82 {Omega} or j58.24+21.16 {Omega}, respectively. Its real-part had a rather large value and rather large rf-power dependence unexpectedly. By using the measured impedance, the circuit to produce rf-plasma in the plasma chamber on a -50 kV potential with a 13.56 MHz-rf-source on the ground potential was designed by the circuit simulation code LTSpice IV.

43 PARTICLE ACCELERATORS↗

Diagnostics for the optimization of an 11 keV inverse Compton scattering x-ray source

In a scope of a collaboration between Thales Communications and Security and CEA DAM DIF, 11 keV Xrays were produced by inverse Compton scattering on the ELSA facility. In this type of experiment, X-ray observation lies in the use of accurate electron and laser beam interaction diagnostics and on fitted X-ray detectors. The low interaction probability between < 100 {mu}m width, 12 ps [rms] length electron and photon pulses requires careful optimization of pulse spatial and temporal covering. Another issue was to observe 11 keV X-rays in the ambient radioactive noise of the linear accelerator. For that, we use a very sensitive detection scheme based on radio luminescent screens.

43 PARTICLE ACCELERATORS↗

Solid state RF power: The route to 1W per euro cent

In most particle accelerators RF power is a decisive design constraint due to high costs and relative inflexibility of current electron beam based RF sources, i.e. Klystrons, Magnetrons, Tetrodes etc. At VHF/UHF frequencies the transition to solid state devices promises to fundamentally change the situation. Recent progress brings 1 Watt per Euro cent installed cost within reach. We present a Silicon Carbide semiconductor solution utilising the Solid State Direct Drive technology at unprecedented efficiency, power levels and power densities. The proposed solution allows retrofitting of existing RF accelerators and opens the route to novel particle accelerator concepts.

43 PARTICLE ACCELERATORS↗

Langmuir probe diagnostics of plasma in high current electron cyclotron resonance proton ion source

A high current Electron Cyclotron Resonance (ECR) proton ion source has been developed for low energy high intensity proton accelerator at Bhabha Atomic Research Centre. Langmuir probe diagnostics of the plasma generated in this proton ion source is performed using Langmuir probe. The diagnostics of plasma in the ion source is important as it determines beam parameters of the ion source, i.e., beam current, emittance, and available species. The plasma parameter measurement in the ion source is performed in continuously working and pulsed mode using hydrogen as plasma generation gas. The measurement is performed in the ECR zone for operating pressure and microwave power range of 10{sup −4}–10{sup −3} mbar and 400–1000 W. An automated Langmuir probe diagnostics unit with data acquisition system is developed to measure these parameters. The diagnostics studies indicate that the plasma density and plasma electron temperature measured are in the range 5.6 × 10{sup 10} cm{sup −3} to 3.8 × 10{sup 11} cm{sup −3} and 4–14 eV, respectively. Using this plasma, ion beam current of tens of mA is extracted. The variations of plasma parameters with microwave power, gas pressure, and radial location of the probe have been studied.

43 PARTICLE ACCELERATORS↗

An overview of the facilities, activities, and developments at the University of North Texas Ion Beam Modification and Analysis Laboratory (IBMAL)

The Ion Beam Modification and Analysis Laboratory (IBMAL) at the University of North Texas includes several accelerator facilities with capabilities of producing a variety of ion beams from tens of keV to several MeV in energy. The four accelerators are used for research, graduate and undergraduate education, and industrial applications. The NEC 3MV Pelletron tandem accelerator has three ion sources for negative ions: He Alphatross and two different SNICS-type sputter ion sources. Presently, the tandem accelerator has four high-energy beam transport lines and one low-energy beam transport line directly taken from the negative ion sources for different research experiments. For the low-energy beam line, the ion energy can be varied from {approx}20 to 80 keV for ion implantation/modification of materials. The four post-acceleration beam lines include a heavy-ion nuclear microprobe; multi-purpose PIXE, RBS, ERD, NRA, and broad-beam single-event upset; high-energy ion implantation line; and trace-element accelerator mass spectrometry. The NEC 3MV single-ended Pelletron accelerator has an RF ion source mainly for hydrogen, helium and heavier inert gases. We recently installed a capacitive liner to the terminal potential stabilization system for high terminal voltage stability and high-resolution microprobe analysis. The accelerator serves a beam line for standard RBS and RBS/C. Another beamline for high energy focused ion beam application using a magnetic quadrupole lens system is currently under construction. This beam line will also serve for developmental work on an electrostatic lens system. The third accelerator is a 200 kV Cockcroft-Walton accelerator with an RF ion source. The fourth accelerator is a 2.5 MV Van de Graaff accelerator, which was in operation for last several decades is currently planned to be used mainly for educational purpose. Research projects that will be briefly discussed include materials synthesis/modification for photonic, electronic, and magnetic applications, surface sputtering and micro-fabrication of materials, development of high-energy ion microprobe systems, and educational and outreach activities.

43 PARTICLE ACCELERATORS↗