Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Total Temperature Measurements in Icing Cloud Flows Using a Rearward Facing Probe

This paper reports on temperature and humidity measurements from a series of ice-crystal icing tunnel experiments conducted in June 2018 at the Propulsion Systems Laboratory at the NASA Glenn Research Center. The tests were fundamental in nature and were aimed at investigating the icing processes on a two-dimensional NACA0012 airfoil subjected to artificially generated icing clouds. Prior to the tests on the airfoil, a suite of instruments, including total temperature and humidity probes, were used to characterize the thermodynamic flow and icing cloud conditions of the facility. Two different total temperature probes were used in these tests which included a custom designed rearward facing probe and a commercial self-heating total temperature probe. The rearward facing probe, the main total temperature probe, was designed to reduce and mitigate the contaminating effects of icing and ingestion of ice crystals and water droplets at the probe's inlet. The probe also serves as an air-sample inlet for a light absorption based humidity measurement. The paper includes a section which discusses total temperature and humidity measurement considerations, and another section which provides an analysis of the main probe's performance characteristics. A computational fluid dynamic model of the flow around the probe was also conducted to gain insight into the trajectory of the flow entering the probe inlet. The experiments included a series of tests in which the relative humidity of the facility flow was swept through with increasingly larger values. The data showed that the rearward facing probe can reasonably capture the flow's total temperature and humidity under mild to moderate icing conditions but produces anomalous results under more intense icing conditions. The experimental data was also compared to an in-house developed thermodynamic model which takes into account the interaction of the main flow with the icing cloud. Comparison to the thermodynamic model showed that the rearward facing probe measured the predicted trends.

Agui, Juan H.↗

C-5 Electrical Substation (SWMU 066) Performance Monitoring Report

The C-5 Electrical Substation (C5ES) is a National Aeronautics and Space Administration (NASA) operated electrical power substation located at the John F. Kennedy Space Center (KSC), Florida. This facility has been designated Solid Waste Management Unit (SWMU) 066 under KSC’s Resource Conservation and Recovery Act (RCRA) Corrective Action program. This Performance Monitoring Report (PMR) presents the Interim Measure (IM) activities, including baseline sampling, air sparge system construction and operation, and performance monitoring, that were completed to remediate chlorinated volatile organic compounds (CVOC) in groundwater exceeding the Florida Department of Environmental Protection (FDEP) natural attenuation default concentrations (NADC).

Andrew Scott Starr↗

Detecting Volcanic Co2 Emissions Hidden in Tropical Volcanic Forests Using Fixed-Wing sUAS

CO2 emissions are among the earliest indicators of subsurface state change and reactivation of volcanic systems and these deep signals reflect in faint diffuse emissions variations on volcanic flanks. Monitoring vast areas of rainforests covering tropical volcanoes is challenging, and space-borne sensors like OCO-2 are not sensitive enough. Fortunately, trees exposed to mild enhancements of CO2 may experience fertilization and build excess CO2 into excess biomass (Cawse-Nicholson, et al. 2018, Biogeosciences). They also process excess CO2 through photosynthesis, measurable by fluorescence (Bogue et al., 2019, Biogeosciences). Furthermore, spaceborne remote sensing instruments have demonstrated increasing NDVI months to years before eruptions, unexplained by other factors (e.g., Houlie et al. 2006, EPSL; Seiler et al. 2017, PLoS One). By providing a means to map large areas of above-canopy CO2 variations over tropical rainforest on the flanks of actively degassing volcanoes, we enable to interpret the signals plants provide in response to excess CO2 with airborne and spaceborne hyperspectral remote sensing methods, including a possible future Surface Biology and Geology (SBG) NASA satellite mission.As a critical step to mature and test this concept, we deployed small unmanned aerial systems (sUAS) using a fixed-wing sUAS designed for autonomous operations and long endurance in extreme environments, without causing significant disturbance of the sampled air. We integrated an in-situ sensor to record the CO2 enhancement field above the forest canopy. Test flight results on the flanks of Turrialba volcano in Costa Rica above forest canopies covering known moderate gas seeps demonstrate the sUAS-borne detection and mapping capabilities of above-canopy elevated CO2 gradients. The strong detection capabilities and high detector signal stability resulted from key system design elements including RF shielding, mechanical stabilization, and calibration procedures. This highly robust system is readily applied for diffuse volcanic CO2 emission studies on active volcanoes covered by dense vegetation.

Volcanic↗

Soyuz 22 Return Samples: Assessment of Air Quality Aboard the International Space Station

Three mini-grab sample containers (m-GSCs) were returned aboard Soyuz 22 because of concerns that new air pollutants were present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The toxicological assessment of 3 m-GSCs from the ISS is shown in Table 1. The recoveries of the 3 standards (as listed above) from the GSCs averaged 103, 95 and 76%, respectively. Recovery from formaldehyde control badges were 90 and 91%.

Jams, John T.↗

Soyuz 23 Return Samples: Assessment of Air Quality Aboard the International Space Station

Six mini-grab sample containers (m-GSCs) were returned aboard Soyuz 23 because of concerns that new air pollutants had been present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The TOC began to decline in late October, 2010. The toxicological assessment of 6 m-GSCs from the ISS is shown in Table 1. The recoveries of 13C-acetone, fluorobenzene, and chlorobenzene from the GSCs averaged 73, 82, and 59%, respectively. We are working to understand the sub-optimal recovery of chlorobenzene.

James, John T.↗

CITE 3 meteorological highlights

Meteorological highlights from the third NASA Global Tropospheric Experiment Chemical Instrumentation Test and Evaluation (GTE/CITE 3) are presented. During August and September 1989, research flights were conducted from Wallops Island, Virginia, and Natal, Brazil, and included airborne sampling of air masses over adjacent regions of the Atlantic Ocean. Isentropic backward trajectory calculations, wind vector/streamline fields, rawinsonde data, and GOES and METEOSAT satellite imagery are utilized to examine the meteorological conditions for each flight and to determine the transport paths of the sampled air masses. Some aspects of the chemical signatures of the sampled air are also discussed. During the series of flights based at Wallops Island, Virginia, the flow into the experiment area was governed primarily by the position of the North Atlantic subtropical anticyclone. The large-scale tropospheric circulation switched from primarily a marine flow during flights 1-4, to a predominantly offshore mid-latitude continental flow during flights 5-10. During these later flights, the regional influences of large eastern U.S. cities along with vertical mixing by typical summertime convective activity strongly influenced the chemical characteristics of the sampled air. During the series of flights based at Natal, Brazil, the dominant synoptic feature was the South Atlantic subtropical anticyclone which generally transported air across the tropical Atlantic toward eastern Brazil. Pronounced subsidence and a well-defined trade wind inversion often characterized the lower and middle troposphere over the Natal region. Some high-altitude recirculation of air from South America was observed, as was cross-equatorial transport which had come from northern Africa. Biomass burning plumes were observed on segments of all of the flights, the source region being the central and southern savannah regions of Africa.

Shipham, Mark C.↗

Soyuz 24 Return Samples: Assessment of Air Quality Aboard the International Space Station

Fifteen mini-grab sample containers (m-GSCs) were returned aboard Soyuz. This is the first time all samples were acquired with the mini-grab samplers. The toxicological assessment of 15 m-GSCs from the ISS is shown. The recoveries of the 3 internal standards, C(13)-acetone, fluorobenzene, and chlorobenzene, from the GSCs averaged 75, 97 and 79%, respectively. Formaldehyde badges were not returned on Soyuz 24

James, John T.↗

Biases in Total Precipitable Water Vapor Climatologies from Atmospheric Infrared Sounder and Advanced Microwave Scanning Radiometer

We examine differences in total precipitable water vapor (PWV) from the Atmospheric Infrared Sounder (AIRS) and the Advanced Microwave Scanning Radiometer (AMSR-E) experiments sharing the Aqua spacecraft platform. Both systems provide estimates of PWV over water surfaces. We compare AIRS and AMSR-E PWV to constrain AIRS retrieval uncertainties as functions of AIRS retrieved infrared cloud fraction. PWV differences between the two instruments vary only weakly with infrared cloud fraction up to about 70%. Maps of AIRS-AMSR-E PWV differences vary with location and season. Observational biases, when both instruments observe identical scenes, are generally less than 5%. Exceptions are in cold air outbreaks where AIRS is biased moist by 10-20% or 10-60% (depending on retrieval processing) and at high latitudes in winter where AIRS is dry by 5-10%. Sampling biases, from different sampling characteristics of AIRS and AMSR-E, vary in sign and magnitude. AIRS sampling is dry by up to 30% in most high-latitude regions but moist by 5-15% in subtropical stratus cloud belts. Over the northwest Pacific, AIRS samples conditions more moist than AMSR-E by a much as 60%. We hypothesize that both wet and dry sampling biases are due to the effects of clouds on the AIRS retrieval methodology. The sign and magnitude of these biases depend upon the types of cloud present and on the relationship between clouds and PWV. These results for PWV imply that climatologies of height-resolved water vapor from AIRS must take into consideration local meteorological processes affecting AIRS sampling.

Atmospheric Infrared Sounder (AIRS)↗

Soyuz 7 Return Samples: Assessment of Air Quality Aboard the International Space Station

The toxicological assessments of one grab sample canister (GSC), 6 dual sorbent tubes (DSTs), and 20 formaldehyde badges returned aboard Soyuz 7 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSC were 84-89%. The recoveries of the less volatile surrogates from the DSTs were 87 to 112%; however, 13C-acetone was only recovered at 53-59%. Formaldehyde recoveries from 2 lab controls were 87 and 95%; trip controls were not returned to ground.

James, John T.↗

STS 117 Return Samples: Assessment of Air Quality aboard the Shuttle (STS-117) and International Space Station

The toxicological assessments of 2 grab sample canisters (GSCs) and one pair of formaldehyde badges from the Shuttle are reported. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the 2 GSCs averaged 109, 95, and 97%, respectively. Three formaldehyde controls averaged 93% recovery. The Shuttle atmosphere was acceptable for human respiration.

James, John T.↗

STS 118 Return Samples: Assessment of Air Quality aboard the Shuttle (STS-118) and International Space Station

The toxicological assessments of 2 grab sample canisters (GSCs) and one pair of formaldehyde badges from the Shuttle are reported. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the 2 GSCs averaged 120, 117, and 122 %, respectively. Three formaldehyde controls averaged 98% recovery. The Shuttle atmosphere was acceptable for human respiration. The toxicological assessment of 8 GSCs and 6 pairs of formaldehyde badges from the ISS is shown. The recoveries of the 3 standards (as listed above) from the GSCs averaged 99, 99 and 99%, respectively. Three formaldehyde control badges averaged 98% recovery. Based on these limited samples, the ISS atmosphere is acceptable for human respiration. The alcohol levels were well controlled throughout the period of sampling.

James, John T.↗

Hygrometer for Detecting Water in Partially Enclosed Volumes

A portable hygrometer has been devised to implement a pre-existing technique for detecting water trapped in partially enclosed volumes that may be difficult to reach and cannot be examined directly. The technique is based on the fact that eventually the air in such a volume becomes saturated or nearly so. The technique is straightforward: One measures the relative humidity and temperature of both the ambient air and a sample of air from the enclosed volume. If the relative humidity of the sample is significantly greater than that of the ambient air and/or if the sample is at or close to the dew point, then it can be concluded that water is trapped in the volume. Of course, the success of this technique depends on the existence of an access hole through which one can withdraw some air from the enclosed volume.

Youngquist, Robert C.↗

STS 120 Return Samples: Assessment of Air Quality Aboard the Shuttle (STS-120) and International Space Station (10A)

The toxicological assessments of 2 grab sample canisters (GSCs) from the Shuttle are reported. Formaldehyde badges were not used. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the 2 GSCs averaged 111, 82, and 78%, respectively. The Shuttle atmosphere was acceptable for human respiration.

James, John T.↗

STS 119 Return Samples: Assessment of Air Quality aboard the Shuttle (STS-119) and International Space Station (15A)

The toxicological assessments of 2 grab sample canisters (GSCs) from the Shuttle are reported. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the 2 GSCs averaged 106, 106, and 101 %,respectively. Based on the end-of-mission sample, the Shuttle atmosphere was acceptable for human respiration.

James, John T.↗

STS 130 Return Samples: Assessment of Air Quality Aboard the Shuttle (STS-130) and International Space Station (20A)

The toxicological assessments of 3 grab sample canisters (GSCs) from the Shuttle are reported in Table 1. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates ( 13C-acetone, fluorobenzene, and chlorobenzene) from the 3 Shuttle GSCs averaged 96, 90, and 85 %, respectively. Based on the end-of-mission sample, the Shuttle atmosphere was acceptable for human respiration.

James, John T.↗