Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Simulated aging processes of black carbon and its impact during a severe winter haze event in the Beijing-Tianjin- Hebei region

Black carbon (BC) can mitigate or worsen air pollution through perturbing meteorological conditions. BC aging processes are important for the evolution of particle size, concentration, and optical properties of BC that determines its influence on the meteorology. Here we use the online coupled Weather Research and Forecasting-Chemistry (WRF-Chem) model to quantify the role of BC aging processes, including physical processes (PP) and absorption enhancements (AE), in exerting BC-induced meteorological changes and the associated feedback to PM2.5 (particulate matter less than 2.5 µm in diameter) and O3 concentrations during a severe haze event in Beijing-Tianjin-Hebei (BTH) region during 21-27 February 2014. Our results show that, compared to the simulation without the PP treatment, the simulated near-surface BC concentration and BC mass loading in BTH region is lowered by 6.6 % and 12.1 %, respectively, during the haze event with the PP included. PP increases the proportion of large-size BC (particle diameter greater than 0.312 µm) from 28 %-33 % to 59 %-64 % below 1000 m in BTH region. Both PP and AE enhance the “dome effect” of BC. With both PP and AE considered, a reduction in PBL height due to BC-PBL interaction is 116.3 m (20.7 %), compared to 75.7 m (13.5 %) without AE and 66.6 m (11.9 %) without both PP and AE. However, during this haze event, anomalous northeasterly winds are produced by the direct radiative effect of BC, which further affects the mixing and transport of aerosols. When PBL height is decreased (from 10:00 to 21:00), combining all the impacts on multiple meteorological factors, BC effect without PP and AE, without AE, and with PP and AE, respectively, increases surface concentrations of PM2.5 by 8.3 µg m-3 (6.1 % relative to the mean value), 6.1 µg m-3 (4.5 %) and 9.6 µg m-3 (7.0 %) but decreases surface O3 concentrations by 2.8 ppbv (7.4 %), 4.0 ppbv (9.0 %) and 5.0 ppbv (10.8 %) in BTH region averaged over 21-27 February 2014. Our results highlight the importance of the aging processes and absorption enhancements of BC in simulating weather and air quality.

Chen, Donglin↗

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗

Sensitivity evaluation of the Kudryavtsev permafrost model

Modeling is an important way to assess current and future permafrost spatial distribution and dynamics, especially in data poor areas like the Arctic region. Here, we evaluate a physics-based analytical model, Kudryavtsev's active layer model, which is widely used because it has relatively few data requirements. This model was recently incorporated into a component modeling toolbox, allowing for coupled modeling of permafrost and geomorphic processes over geological timescales. However, systematic quantitative assessment of the influence of its controlling parameters on permafrost temperature and active layer thickness predictions has not been undertaken before. In this work, we investigate the sensitivity of the Kudryavtsev's active layer model by Monte Carlo simulations to generate probability distributions for input parameters and compare predictions with a comprehensive benchmark dataset of in-situ permafrost observations over entire Alaska. Predicted permafrost surface temperature is highly dependent on mean annual air temperature (r = 0.78 on average), annual temperature amplitude (–0.41), and winter-averaged snow thickness (0.30). Uncertainty of predicted permafrost temperature is relatively small (RMSE = 1 °C), when air temperature and snow depth are well constrained. Similarly, RMSE between simulated and observed ALT at stations is ~0.08 m. However, under given air temperature and snow conditions, soil water content bias can significantly affect modeled active layer thickness (RMSE = 0.1 m or 40% of the observed active layer thickness). If soil water content has a large bias, improvements in other parameters may not significantly improve the active layer predictions of the Kudryavtsev's model.

54 ENVIRONMENTAL SCIENCES↗

Dynamic Modeling and Simulation of a Subcritical Coal-Fired Power Plant under Load-Following Conditions

Dynamic models for power plants that capture realistic general process trends and effects of manipulated variables are needed to improve load-following, while minimizing carbon footprint. In this work, a dynamic modeling approach and simulation results for subcritical coal-fired power plant components are presented. These encompass simulation of the dynamics in the fireside, including the effects of fuel, air combustion, and the dynamics of the entire waterside and power generation sections. This model development enables the simulation and analysis of the important short and long-time scale dynamics of components such as heaters, evaporative loop, and power generation units. Furthermore, additional variables in the power generation section are introduced to improve model accuracy, extending the prediction capability of subcritical power plant models and opening new opportunities for research in operator training, optimization, and advanced model-based controller design that are based on these models. The change in process gain for different ramp rates associated with disturbance signals that affect process variables is also explored and a correlation developed. This provides opportunities to study disturbance rejection control implementation and adaptation for scenarios with such variations in ramp rates. The prediction capabilities of selected components are compared to data available in literature, with the obtained root mean squared error ranges that reflect the model performance and quality of predictions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dose Coefficient Calculation for Use in Dosimetry Assessment of a Fission-Based Weapon

In the event of a fission-based weapon or improvised nuclear device (IND) detonation, dose coefficients can be harnessed to provide dose assessments for defense, emergency preparedness, and consequence management, as well as to prospectively inform the assessment of radiation biomarkers and development of medical prophylaxis countermeasures for defense and homeland security stakeholders and decision-makers. Although dose coefficients have previously been calculated for this group, they would apply specifically to the studied population, the 1945 Japanese cohort, after which their anthropomorphic computational phantoms were modeled. For this reason, applications to other populations may be limited, and instead, an assessment of a more standardized population is desired. We employed a series of computational human phantoms representing international reference individuals: UF/NCI voxel phantom series containing newborn, 1-, 5-, 10-, 15-, and 35-year-old males and females. Irradiation of the phantoms was simulated using the Monte Carlo N-Particle transport code to determine organ dose coefficients under four idealized irradiation geometries at three distances from the detonation hypocenter at Hiroshima and Nagasaki using DS02 free-in-air prompt neutron and photon fluence spectra. Through these simulations, age-specific dose coefficients were determined for individual organs. Various articulated PIMAL stylized phantoms were simulated as well to estimate the effect of body posture on dose coefficients and determine the effect of posture on dosimetric estimation and reconstruction. Results additionally demonstrate that 137 Cs and the Watt fission spectra are not ideal general surrogate sources for fission weapons, which may be considered for experimental testing of medical countermeasures. Supplementary data provided tabulates the compilation of organ dose-rate coefficients in this study.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Implications of Sea Breeze Circulations on boundary layer aerosols in the southern coastal Texas region

The Sea Breeze Circulation (SBC) influences atmospheric processes at multiple scales in coastal regions. Understanding how SBCs impact the aerosol number budget and aerosol–cloud interaction processes is essential. This study investigates sea breeze–aerosol interactions (SAIs) during 46 summertime SBC events using data from the TRacking Aerosol Convection Interactions Experiment (TRACER) field campaign across urban (main) and rural (supplemental) coastal sites in southern Texas. Weather Research and Forecasting model coupled with Chemistry (WRF-Chem) simulations complement observations to explore spatio-temporal meteorological controls on boundary layer aerosols. During the summertime, Sea Breeze Fronts (SBF) penetrating inland transported cool, moist air over the land, introducing air masses with distinct properties compared to the preexisting continental air. These SAIs cause variability in number concentrations of up to a factor of two, with events typically lasting ∼ 5 h before returning to background conditions. SAI impact on aerosols varies with site proximity to water and the preceding sea breeze (SB) history, primarily affecting the marine-influenced accumulation mode. The main site, influenced by both Galveston Bay and the Gulf of Mexico, reflects a stronger marine influence. In contrast, a supplemental site, at a similar shoreline distance but exposed only to the Gulf of Mexico and typically upstream of the urban core, samples SB air that has traversed land and partially regained continental characteristics. Simulations show that the regional SAIs extend ∼ 50 km inland and reach up to the boundary layer height. SAIs further decrease cloud condensation nuclei relevant aerosol number concentrations in ∼ 20 % of events during SBF passage.

54 ENVIRONMENTAL SCIENCES↗

Ab initio metadynamics calculations reveal complex interfacial effects in acetic acid deprotonation dynamics

Acid-base reactions play a central role in solution chemistry, with carboxylic acids being particularly important in atmospheric chemical processes. In this work, we harness metadynamics calculations with Born-Oppenheimer molecular dynamics (BOMD) simulations to understand deprotonation dynamics of acetic acid (CH 3 COOH) in both bulk and air-water interfacial environments. Collective variables are carefully chosen in our well-tempered metadynamics simulations to capture the deprotonation process in various aqueous configurations. Herein, our findings show that the free energy barrier for deprotonation of acetic acid at the air-water interface is lower than in the bulk, in accordance with the available experimental data. Furthermore, our well-tempered metadynamics calculations suggest that the variations in free energy are primarily due to intricate solvation shell effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Upper bounds for 21st-century surface air temperatures in the Western United States

The last decade has seen a large number of severe heatwaves that were unprecedented in the observational record, highlighting challenges associated with observationally-based statistical quantification of the likelihood and magnitude of future extreme temperatures. An alternative to such probabilistic assessments is identification of upper bounds that quantify the hottest surface air temperatures that can possibly be achieved by the end of the 21st century. Theory, simulations, and observational analyses support the existence of a finite upper bound for surface air temperature; however, estimates for future upper-bound values that are realistic and usable for planning remain unavailable. Here, we combine atmospheric theory with large ensembles of dynamically downscaled projections to estimate historical and end-of-century upper bounds for surface air temperatures. A number of physical mechanisms can influence upper bounds, and at the end of the 21st century, estimates based on mechanisms that yield more moderate upper-bounds produce values around 60∘C for much of the Western United States and in excess of 80∘C for the hottest parts of the domain. Even cooler high-altitude locations have end-of-century upper bounds over 50∘C. Although these upper-bound estimates might seem implausibly large, increases in the upper bounds over the 21st century are similar to increases in dynamically downscaled peak surface temperatures after adjusting those downscaled temperatures to eliminate the possibly biased model trends in surface specific humidity. While upper bound estimates are high relative to historical observations, they nonetheless suggest that heatwave intensity risk is bounded, with uncertainty dominated by projections of surface and upper-level humidity.

Risser, Mark D↗

Analysis of basic airflow configurations for separate sensible and latent cooling systems with indoor air recirculation

Separate sensible and latent cooling (SSLC) is a technology with efficiency and comfort advantages over conventional cooling systems used for space conditioning of buildings. Using multiple cooling processes at different temperatures allows SSLC to save energy by raising the evaporation temperature of the sensible cooling process. In this paper, all possible airflow configurations of SSLC systems are enumerated under the following constraints: exactly two heat exchangers are used, and air is recirculated to the conditioned space (no exhaust or outdoor air treatment). Seven designs are identified, with varying free operating variables, and each is modeled. Analysis reveals that several configurations are equivalent, and there is only one unique basic airflow SSLC configuration: the one with the sensible and latent heat exchangers placed in series. The efficiency of the SSLC system is compared against that of the conventional system. Under standard conditions, an SSLC system can improve the coefficient of performance by 14.8%. In addition to the numerical simulation, the optimal operating condition of the basic air configuration of the SSLC system is derived analytically. The basic SSLC system is shown to offer the highest performance improvement when the outdoor temperature is relatively cool and the space sensible heat ratio is high.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Historical global Earth System Model simulations with E3SM's dynamic root module

This data package contains global-scale Earth System Model simulations run with DOE's E3SM Model. The package includes one set of simulations run in the default configuration and a second set of simulations run with the dynamic root module enabled. These two datasets can be used to assess the impact that dynamic roots have on Land Surface fluxes such as carbon and water. The outputs are provided here on a 0.5 x 0.5 global grid at monthly resolution. The simulations were run with atmospheric forcing from the Global Soil Wetness Project. We provide specifically here Gross Primary Production, Transpiration, relative root fraction per soil layer as well as Air Temperature, Precipitation and all the parameterizations used for the simulations. Our purpose for generating and analyzing these simulations was to assess the role that root dynamics and foraging for water has in the recovery timescale of ecosystems following climate perturbation. All data provided are in the "netcdf" format using standard CF-1 (Climate and Forecast) Convention. The data are broken up into 20 year chunks to facilitate easier read-in. The data are all machine readable using various software platforms including Matlab, NCO, Panoply and GrADS.

54 ENVIRONMENTAL SCIENCES↗

Global Ocean Cooling of 2.3°C During the Last Glacial Maximum

Abstract Quantitative constraints on past mean ocean temperature (MOT) critically inform our historical understanding of Earth's energy balance. A recently developed MOT proxy based on paleoatmospheric Xe, Kr, and N 2 ratios in ice core air bubbles is a promising tool rooted in the temperature dependences of gas solubilities. However, these inert gases are systematically undersaturated in the modern ocean interior, and it remains unclear how air‐sea disequilibrium may have changed in the past. Here, we carry out 30 tracer‐enabled model simulations under varying circulation, sea ice cover, and wind stress regimes to evaluate air‐sea disequilibrium in the Last Glacial Maximum (LGM) ocean. We find that undersaturation of all three gases was likely reduced, primarily due to strengthened high‐latitude winds, biasing reconstructed MOT by −0.38 ± 0.37°C (1σ). Accounting for air‐sea disequilibrium, paleoatmospheric inert gases indicate that LGM MOT was 2.27 ± 0.46°C (1σ) colder than the pre‐industrial era.

Seltzer, A. M.↗

Comparison of effectiveness and energy use of airborne pathogen mitigation measures to meet clean air targets in a prototypical office building

Organizations such as ASHRAE and the Centers for Disease Control and Prevention (CDC) have proposed guidelines for controlling infectious aerosols in buildings, which can be met through measures such as modified operation of the heating, ventilation, and air-conditioning (HVAC) system or incorporating air-cleaning technologies. However, more research is needed to understand the trade-offs between health, energy, and comfort aspects when designing measures for these guidelines. To address this gap, this paper presents an analysis using new models for air-cleaning technologies, including in-duct and in-room germicidal ultraviolet (GUV) systems and portable air cleaners (PACs). These models are incorporated into an existing prototypical office building model and six measures are designed to meet ASHRAE Standard 241 and CDC clean air targets: MERV 13 HVAC filtration, maximum outdoor air supplied to the building, PACs, and in-duct, upper-room, and whole-room GUV. The measures are simulated for an office building in a cool and humid climate compared against a baseline simulation using MERV 8 filtration. The results show that all measures, except for the maximum outdoor air case, can meet the ASHRAE 241 standard without significant impacts on energy or comfort. The HVAC system measures were not able to meet the CDC target with the default system sizing and lead to significant energy increases, while the in-room measures were able to meet the CDC target with small impacts on energy consumption. Finally, this paper consolidates the simulation findings and provides practical guidance for building operators to meet clean air targets while limiting energy and comfort impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Earth System Model Simulations of Ameriflux sites using dynamic roots and dynamic leaf to root allocation

This data package contains point-scale Earth System Model simulations run with DOE's E3SM Model. The package includes four sets of simulations, one set of simulations run in the default configuration, a second set of simulations run with the dynamic root module enabled, the third set with dynamic leaf to fine root allocation, and the fourth with the combination of dynamic roots and dynamic allocation. These simulations were run in point mode a Ameriflux sites, US-MMS, US-Moz, US-Syv, and US-NR1. These datasets can be used to assess the impact that dynamic roots have on Land Surface fluxes such as carbon and water. The simulations were run with atmospheric forcing from the Global Soil Wetness Project. We provide specifically here Gross Primary Production, Transpiration, relative root fraction per soil layer as well as Air Temperature, Precipitation and all the parameterizations used for the simulations. Our purpose for generating and analyzing these simulations was to assess the role that root dynamics and foraging for water has in the recovery timescale of ecosystems following climate perturbation. All data provided are in the "netcdf" format using standard CF-1 (Climate and Forecast) Convention. The data are all machine readable using various software platforms including Matlab, NCO, Panoply and R.

54 ENVIRONMENTAL SCIENCES↗

Simulating physical and biogeochemical dynamics of the Arctic Ocean [Slides]

Ocean physics (currents, mixing, air-sea transfer of heat and gases) and biogeochemistry (carbon and oxygen cycles, ecosystem dynamics, nutrient distributions) are tightly coupled. We used the DOE-developed Energy Exascale Earth System Model (E3SM) to simulate physical and biogeochemical dynamics of the global ocean, with an emphasis on the western North Pacific. In particular, we used the grid refinement capability of E3SM’s ocean component (LANL-developed MPASOcean) to quantify the effect of model resolution on the carbon and oxygen cycles using a pair of century-long simulations that differ only in the western North Pacific grid. Regional grid refinement has a noticeable impact on biogeochemistry. Distribution of important nutrients (such as nitrate) changes the amount of photosynthesis by phytoplankton, which in turn affects air-sea transfer of CO2 and the local carbon cycle.

58 GEOSCIENCES↗

A Simulation Framework for Analyzing the Impact of Stochastic Occupant Behaviors on Demand Flexibility in Typical Commercial Buildings

As one of the primary users of the electric grid, buildings and building equipment, including heating, ventilation, and air conditioning (HVAC) systems, can be leveraged to provide the flexible demand needed to balance the grid. Typical strategies to achieve demand flexibility are to reduce electricity use during peak or critical periods by shutting down equipment or relaxing system setpoints, which will inevitably impact the occupants’ comfort. When occupants feel uncomfortable, they may take actions to regain their comfort, and some of those actions (such as turning on a personal fan) may have a negative impact on meeting the demand response goal. Therefore, it is important to incorporate occupant behaviors into the assessment ofthe building demand flexibility potential. In this study, a simulation framework that includes simulation of zone thermal loads, an HVAC system, and occupant behaviors, was developed to investigate the impact of occupant behaviors on demand flexibility. A case study was conducted using a small office model from the U.S. Department of Energy (DOE) Commercial Prototype Building Models to simulate the building envelope and zone loads. An agent-based occupant thermal behavior model was adapted to forecast occupants’ thermal comfort and their resulting thermal behaviors. An artificial neural network (ANN) based airflow model trained from a computational fluid dynamics (CFD) model of the zone was adopted to better predict the ambient environment of each occupant. An air-source heat pump simulation model that was calibrated from a real two-stage air-source heat pump system was used as the HVAC system. A typical load shedding event during peak hours was studied. Repeated simulations were conducted to capture the stochastic effects of occupant behaviors. The interplay between the demand flexibility, occupant comfort and behavior were analyzed by evaluating key performance indicators, including the energy use, occupant discomfort duration, and occupant behavior duration during the peak period. The results suggest that this framework can be used to analyze typical commercial buildings and their HVAC systems in terms ofdemand flexibility potential under the impact of occupant behaviors.

Chen, Zhelun↗

Heat Pumps with Phase Change Thermal Storage: Flexible, Efficient, and Electrification Friendly

As we continue to electrify space- and water-heating, the electricity demand profile of many buildings will change significantly, and periods of high electricity demand will likely not align with renewable energy generation. We expect electricity demands will increase substantially in the winter, annual maximum electricity demands will increase, and more regions will experience annual peak electrical demands – and higher wholesale electricity prices – in the winter. This is especially important for cold climates where 60% of site energy use in buildings is for heating, and where heat pumps perform least efficiently. This paper focuses on one promising solution among the many paths to electrification: the use of phase change materials (PCM) for compact low-cost thermal energy storage (TES). We present the design and simulation of a combi heat pump and phase change thermal storage system used for space- and water-heating in a multifamily residence in a cold climate. To assess the benefits of this technology, we compare its annual performance to that of a current state-of-the-art air-to-air heat pump and separate heat pump water heater. Simulation results for IECC Climate Zone 6A reveal that the combi heat pump with phase change thermal storage can reduce the design size for heat pumps by 40-60%, reduce maximum electric demand by 30-50%, reduce electricity use during 4-12-hour load shed periods by 50%, and avoid the need for auxiliary electric resistance for both space- and water-heating. Tariff structures are highly varied between different utilities and currently reflect higher wholesale market prices for electricity during summer days. Consequently, although this system design provides large electric demand reductions during hypothetical 4-12-hour load shed periods, it does not provide energy cost reductions with current winter residential time-of-use tariffs.

Helmns, Dre↗

Design and Modeling of a Demonstration-scale ORC Cycle for the Liquid Air Combined Cycle

Energy storage is becoming an increasing focus for the future energy markets. One potential hybrid system for ling duration energy storage is the Liquid Air Combined Cycle (LACC). The LACC utilizes excess renewable energy to liquefy and store air during the charge cycle. During its discharge cycle, the system uses the exhaust heat from a conventional combustion turbine and an ORC bottoming cycle to vaporize and superheat the stored air that has been pressurized, which is subsequently expanded to atmosphere through a turbine. During the development of the cycle, it has been identified that the main technologies to advance the cycle are the ORC bottoming cycle machinery and the coupled operation between the liquified air subsystem and the ORC subsystem. This paper presents modeling and simulation of the LACC that involves ORC conditions that fall outside the operating regime of more common applications. Due to the low temperatures of liquified air, the ORC system operates on the order of -70°C for the pump, and the turbine has a pressure ratio around 40. The conceptual design of a demonstration system has been developed that focuses on these challenges in order to advance the overall system.

Pryor, Owen↗

Comparing Retrofit Wall Performance Predicted from Hygrothermal Simulations to Measurements

Over the past few years ORNL has been showing that WUFI® can be used to predict the moisture performance of walls when exposed to diffusion of water vapor, convection of moist air through the wall, and solar driven moisture. This is accomplished by comparing the hygrothermal simulation results to carefully instruments walls exposed to these phenomena in a climate chamber. In FY 2018, three stick-built walls were succumbed to typical Chicago, Illinois weather conditions in Oak Ridge National Laboratory’s Heat, Air and Moisture chamber. The measured temperature, relative humidity, and moisture content within these walls were compared with WUFI hygrothermal simulation results. In FY 2019, similar experiments and comparisons with WUFI results were completed with two walls, a structural insulated panel-based wall and a concrete masonry unit-based wall. In FY 2020, experiments were completed for a probable exterior retrofit of a wall which included adding cavity and continuous insulation. Two pairs of walls were tested by exposing them to Chicago winter weather with a positive pressure pushing outside air into the wall. The results from the FY 2020 experiments are reported here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗