The Hot Fuel Examination Facility (HFEF) at the Materials and Fuels Complex (MFC) houses the largest U.S. inert atmosphere hot cell for nuclear material research. Key features include the precision gamma scanning (PGS), Fuel Accident Condition Simulator (FACS), Neutron Radiography Reactor (NRAD), and the focus of this project, the Metallograph Loading Cell (MET Cell). The MET Cell performs tests on spent nuclear fuel, such as microhardness testing, microscopy, and neutron radiography. However, the MET Cell’s existing pressure and lighting control systems are outdated and inefficient, with inadequate documentation for system changes over time. This project aims to design a new automated control system for the MET Cell, ensuring longevity (minimum ten years), ease of troubleshooting/repair, and integration into the building monitoring system. The design process addressed challenges such as space restrictions, varied voltages within enclosures, sourcing new components, and security limitations. Compliance with NFPA 70, UL508A, MFC Physical Security, and INL Engineering standards was essential. The project involves repurposing an existing PLC to manage lighting and pressure control using digital and analog signals, simplifying wiring, and ensuring thorough documentation for future reference.

42 - ENGINEERING↗

Analysis of the Amorphous and Interphase Influence of Comononomer Loading on Polymer Properties toward Forwarding Bioadvantaged Copolyamides

In this paper we present an approach for selectively modifying the properties of semicrystalline polymers by introducing “bioadvantaged” counits. With this approach, the unique functionality of biomass can be leveraged to tailor the properties of the amorphous phase of semicrystalline polymers with minimal impact on crystallinity and thermomechanical properties. As a model case, PA 6,6 copolyamides were produced using the bioadvantaged monomer trans-3-hexenedioic acid (t3HDA). The analogous structure of t3HDA to adipic acid, a PA 6,6 monomer, allows for seamless integration. Screening over the entire composition range identified the t3HDA loading (20 mol%) beyond which properties deviate appreciably from Nylon 6,6. Once identified, copolyamides of suitable compositions were upgraded to commercial quality and fully characterized to assess the influence of counit loading and polymer structure on thermal and mechanical properties. Samples were characterized using gel permeation chromatography (GPC), proton nuclear magnetic resonance spectroscopy (1H NMR), heteronuclear single quantum coherence spectroscopy (HSQC), wide-angle X-ray scattering (WAXS), differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), dynamic mechanical analysis (DMA), tensile testing, flexural testing, and water absorption testing. t3HDA units were shown to hydrate during the harsh polycondensation to 3-hydroxyhexanedioic acid (3HHDA) and fully incorporate into the polymer backbone. Loading levels up to 20% were shown to have comparable thermal and mechanical properties in the dry state, yet moisture absorption—a known method for improving the toughness, yield strain, and elongation of polyamides—was enhanced by over 100% at 20% loading. This case study on bioadvantaged copolymers elucidates the governing structure-function principles that can be leveraged to forward value-added renewable polymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of an MC&A toolbox for liquid-fueled molten salt reactors with online reprocessing (Final Report)

A critical barrier to the deployment of MSRs is the absence of a well-defined nuclear material control and accounting (MC&A) approach, a vital prerequisite to meet NRC licensing requirements as well as facilitating future international exports. Liquid-fueled MSR variants (especially those incorporating online refueling or reprocessing) present a unique set of challenges to traditional nuclear material control and accountancy. Unlike solid-fueled light-water reactors, traditional item-counting methods cannot be applied as an accountancy strategy. Rather, MC&A approaches to MSR variants (including both uranium and thorium fueled designs) are more analogous to bulk material handling facilities (e.g., enrichment and reprocessing); yet further complicating matters is the fact that fuel medium is also highly radioactive. Meanwhile, the space of MSRs covers a broad range of design parameters, including thermal and fast spectra designs; operation in actinide breeder or burner modes, choice of actinide fuel used (e.g., 235 U, 232 Th / 233 U, denatured 233 U, etc.), pool or loop-type configuration, and even different salt chemistry. Each of these design choices introduce significant challenges to MC&A approaches within MSR facilities. We propose to bridge this gap for liquid-fueled MSRs by developing a modular, component-based test framework for evaluating viable process monitoring and MC&A techniques specifically suited to liquid-fueled MSR system variants employing online refueling or reprocessing. This test platform will consist of a toolbox of independent process modules representing discrete physical units (such as the reactor core, off-gas processing, decay tanks, and actinide separation units), each with its own self-contained physics responsive to the input mass flow, along with appropriate measurement models that can be coupled to key flow points. These dynamic physical signatures thus afford the ability to test the viability and efficacy of potential accountancy techniques under the full range of reactor operating conditions. As process modules are connected via mass flows, the result is a reconfigurable, generic MSR mass flow model capable of serving as an MC&A test platform for a broad spectrum of possible MSR configurations. The resulting MSR MC&A toolbox will enable robust assessment of accountancy strategies for this unique facility type, including analysis of physical feedbacks arising both from depletion of the fuel over time as well as from potential off-normal events, including those introduced by equipment failures (e.g., a pump failure) as well as by malicious action (i.e., attempts to divert material). The proposed toolbox both addresses a critical needs area for the MPACT analysis toolkit while leveraging existing MPACT-sponsored tools, especially with respect to simulation of measurement and accountancy techniques for advanced fuel cycle facilities. Beyond enabling new analysis capabilities for MSR systems, the design of this toolbox will be to such to maximize compatibility with existing MPACT tools, such to enhance existing facility MC&A analysis capabilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gravitational wave spectrum of chain inflation

Chain inflation is an alternative to slow-roll inflation in which the inflaton tunnels along a large number of consecutive minima in its potential. In this work we perform the first comprehensive calculation of the gravitational wave (GW) spectrum of chain inflation. In contrast to slow-roll inflation the latter does not stem from quantum fluctuations of the gravitational field during inflation, but rather from the bubble collisions during the first-order phase transitions associated with vacuum tunneling. Our calculation is performed within an effective theory of chain inflation which builds on an expansion of the tunneling rate capturing most of the available model space. The effective theory can be seen as chain inflation’s analog of the slow-roll expansion in rolling models of inflation. The near scale-invariance of the scalar power spectrum translates to a quasiperiodic shape of the inflaton potential in chain inflation, with the tunneling rate changing very slowly during the e-folds leading to cosmic microwave background observables. We show that chain inflation produces a very characteristic double-peak GW spectrum: a faint high-frequency peak associated with the gravitational radiation emitted during inflation, and a strong low-frequency peak associated with the graceful exit from chain inflation (marking the transition to the radiation-dominated epoch). There exist very exciting prospects to test the gravitational wave signal from chain inflation at the aLIGO-aVIRGO-KAGRA network, at LISA and /or at pulsar timing array experiments. A particularly intriguing possibility we point out is that chain inflation could be the source of the stochastic gravitational wave background recently detected by NANOGrav, PPTA, EPTA, and CPTA. We also show that the gravitational wave signal of chain inflation is often accompanied by running/ higher running of the scalar spectral index to be tested at future cosmic microwave background experiments. Published by the American Physical Society 2024

Freese, Katherine↗

Coherent Many-Body Oscillations Induced by a Superposition of Broken Symmetry States in the Wake of a Quantum Phase Transition

It is now widely accepted that quenches through the critical region of quantum phase transitions result in post-transition states populated with topological defects—analogs of the classical topological defects. However, consequences of the very nonclassical fact that the state after a quench is a superposition of distinct, broken-symmetry vacua with different numbers and locations of defects have remained largely unexplored. Here, we identify coherent quantum oscillations induced by such superpositions in observables complementary to the one involved in symmetry breaking. These oscillations satisfy Kibble-Zurek dynamical scaling laws with the quench rate, with an instantaneous oscillation frequency set primarily by the gap of the system. In addition to the obvious fundamental significance of a superposition of different broken symmetry states, quantum coherent oscillations can be used to verify unitarity and test for imperfections of the experimental implementations of quantum simulators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparing three generations of D-Wave quantum annealers for minor embedded combinatorial optimization problems

Abstract Quantum annealing (QA) is a novel type of analog computation that aims to use quantum mechanical fluctuations to search for optimal solutions of Ising problems. QA in the transverse Ising model, implemented on D-Wave quantum processing units, are available as cloud computing resources. In this study we report concise benchmarks across three generations of D-Wave quantum annealers, consisting of four different devices, for the NP-hard discrete combinatorial optimization problems unweighted maximum clique and unweighted maximum cut on random graphs. The Ising, or equivalently quadratic unconstrained binary optimization, formulation of these problems do not require auxiliary variables for order reduction, and their overall structure and weights are not highly variable, which makes these problems simple test cases to understand the sampling capability of current D-Wave quantum annealers. All-to-all minor embeddings of size 52, with relatively uniform chain lengths, are used for a direct comparison across the Chimera, Pegasus, and Zephyr device topologies. A grid-search over annealing times and the minor embedding chain strengths is performed in order to determine the level of reasonable performance for each device and problem type. Experiment metrics that are reported are approximation ratios for non-broken chain samples, chain break proportions, and time-to-solution for the maximum clique problem instances. How fairly the quantum annealers sample optimal maximum cliques, for instances which contain multiple maximum cliques, is quantified using entropy of the measured ground state distributions. The newest generation of quantum annealing hardware, which has a Zephyr hardware connectivity, performed the best overall with respect to approximation ratios and chain break frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RAD51C-XRCC3 structure and cancer patient mutations define DNA replication roles

$RAD51C$ is an enigmatic predisposition gene for breast, ovarian, and prostate cancer. Currently, missing structural and related functional understanding limits patient mutation interpretation to homology-directed repair (HDR) function analysis. Here we report the RAD51C-XRCC3 (CX3) X-ray co-crystal structure with bound ATP analog and define separable RAD51C replication stability roles informed by its three-dimensional structure, assembly, and unappreciated polymerization motif. Mapping of cancer patient mutations as a functional guide confirms ATP-binding matching RAD51 recombinase yet highlights distinct CX3 interfaces. Analyses of CRISPR/Cas9-edited human cells with $RAD51C$ mutations combined with single-molecule, single-cell and biophysics measurements uncover discrete CX3 regions for DNA replication fork protection, restart and reversal, accomplished by separable functions in DNA binding and implied 5’ RAD51 filament capping. Collective findings establish CX3 as a cancer-relevant replication stress response complex, show how HDR-proficient variants could contribute to tumor development, and identify regions to aid functional testing and classification of cancer mutations.

59 BASIC BIOLOGICAL SCIENCES↗

Tunable polyvinyl chloride (PVC) and thermoplastic polyurethane (TPU)-based soft polymer gel sensors

Abstract Polyvinyl chloride (PVC) gels have recently been found to exhibit mechanoelectrical transduction under mechanical deformation. These mechanoelectrical properties of PVC gels are largely uncharacterized and the underlying transduction mechanisms are currently unknown. These soft electroactive polymers have tunable properties such as modulus and response voltage based on physical dimensions and the amount of plasticizer content within the material making them ideal candidates for complaint sensors. This study aims to investigate PVC gels comprised of various plasticizers to further investigate underlying mechanisms of mechanoelectrical transduction and broaden possible sensing applications. Plasticizers used in this study include dibutyl adipate, dibutyl phthalate, dioctyl phthalate, otherwise known as bis(2-ethylhexyl) phthalate, diisodecyl adipate, and the environmentally friendly biodegradable plasticizer acetyl tributyl citrate (ATBC). ATBC is often used in cosmetics and food packaging applications and is even used as a food additive which may lead to future biocompatibility for these gel sensors. These plasticizers are used to produce PVC gel sensors that are experimentally tested for mechanoelectrical transduction properties and sensing performance. In this study, a Langmuir adsorptive model is fit to the collected mechanoelectrical transduction data. These results are also nondimensionalized and compared to the characteristic dimensionless Langmuir adsorptive model. This simple model agrees very well with the experimental data. Additionally, a study on the mechanoelectrical transduction of an alternative polymer lattice structure, thermoplastic polyurethane (TPU), is discussed. This is a novel electroactive polymer investigated for mechanoelectrical transduction properties. This portion of the study aims to further knowledge of underlying mechanisms of mechanoelectrical transduction as well as show feasibility of additional lattices for soft polymer gel sensors. These TPU gel sensors show strikingly similar mechanoelectrical transduction properties to analogous PVC gels, insinuating that the polymer structure has a limited role in the underlying sensing mechanism and PVC itself is not unique to polymer gel sensing. The TPU-based soft polymer gel sensors however do display some level of mechanoelectrical hysteresis which may be attributed to viscoelastic properties and display a small amount of fatigue possibly due to exudation of liquid plasticizer. This study provides further characterization of mechanoelectrical response for varying plasticizers, provides a theoretical framework for underlying mechanisms, and displays the potential for further polymeric gel sensors.

Instruments & Instrumentation↗

An isotope harvesting beam blocker for the National Superconducting Cyclotron Laboratory

Harvesting isotopes from beam stops and other activated materials at accelerator facilities is a promising source of environmentally, scientifically and socially important radionuclides. At the Facility for Rare Isotope Beams (FRIB), a multitude of short- and long-lived radionuclides will be collected in a synergistic manner by dumping unused beams into a flowing-water beam stop. Ongoing exploratory research at the National Superconducting Cyclotron Laboratory (NSCL) with an analogous beam blocker aims towards obtaining the necessary radiochemical expertise for this endeavor. Herein we present a beam blocker and an isotope harvesting system which allows collection of a wide variety of aqueous and gaseous radionuclides. The water which flows through the beam blocker functions as an isotope production target and concurrently transports the newly formed radionuclides to collection sites. The system includes analytical instruments for online measurements of conductivity, dissolved oxygen, temperature, pressure and for detection of radiolytic products. To limit the levels of radiolytically produced hydrogen peroxide, a stainless-steel based degradation system was designed and implemented. Here, the suitability of the constructed system for the anticipated radionuclide harvesting project was demonstrated by offline tests and under irradiation with 140 MeV/u 48 Ca 20+ ions at the NSCL Coupled Cyclotron Facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radio frequency mixing modules for superconducting qubit room temperature control systems

As the number of qubits in nascent quantum processing units increases, the connectorized RF (radio frequency) analog circuits used in first generation experiments become exceedingly complex. The physical size, cost, and electrical failure rate all become limiting factors in the extensibility of control systems. We have developed a series of compact RF mixing boards to address this challenge by integrating I/Q quadrature mixing, intermediate frequency/LO (local oscillator)/RF power level adjustments, and direct current bias fine tuning on a 40 × 80 mm 2 four-layer printed circuit board with electromagnetic interference shielding. The RF mixing module is designed to work with RF and LO frequencies between 2.5 and 8.5 GHz. The typical image rejection and adjacent channel isolation are measured to be ~27 dBc and ~50 dB. By scanning the drive phase in a loopback test, the module short-term amplitude and phase linearity are typically measured to be 5 ×10 -4 (V pp /V mean ) and 1 ×10 -3 radian (pk-pk). The operation of the RF mixing board was validated by integrating it into the room temperature control system of a superconducting quantum processor and executing randomized benchmarking characterization of single and two qubit gates. We measured a single-qubit process infidelity of 9.3(3) × 10 -4 and a two-qubit process infidelity of 2.7(1) × 10 -2 .

47 OTHER INSTRUMENTATION↗

Analog-antianalog isospin mixing in 47 K 𝛽−decay

Here, we have measured the isospin mixing of the 𝐼 𝜋 =1/2 + , 𝐸 𝑥 = 2.599 MeV state in nearly doubly magic 47 Ca with the isobaric analog 1/2 + state of 47 K . Using the TRIUMF atom trap for 𝛽 decay, we have measured a nonzero asymmetry of the progeny 47 Ca with respect to the initial 47 K spin polarization, which together with the 𝛽 asymmetry implies a nonzero ratio of Fermi to Gamow-Teller matrix elements 𝑦 = 0.098 ± 0.037 for the 1/2 + → 1/2 + transition. Interpreting 𝑦 as mixing between this state and the isobaric analog state implies a Coulomb matrix element magnitude 101 ± 37 keV. This relatively large matrix element supports a model from the literature of analog-antianalog isospin mixing, which predicts large matrix elements in cases involving excess neutrons over protons occupying more than one major shell. The result supports pursuing a search for time-reversal odd, parity-even, isovector interactions using a correlation in 47 K 𝛽 decay.

beta decay↗

Surrogate Distributed Radiological Sources—Part II: Aerial Measurement Campaign

In this second part of a multipaper series, we present results from outdoor aerial measurements of surrogate distributed gamma-ray sources. Here we detail the design, manufacture, and testing of 300 individual ~7 mCi Cu-64 sealed sources at the Washington State University (WSU) research reactor and their deployment in various source patterns (each comprising up to 100 point sources) during the aerial measurement campaign. We show the results of two such measurements, in which approximate source shapes and qualitative source intensities can be seen from the count rate versus position plots, even without performing reconstructions. We also detail our efforts in ground-truthing the deployed sources and comparing measured gamma-ray data to model predictions. In particular, we compare measured versus expected count data using the Poisson deviance formalism of Part I to evaluate whether the fielded surrogate point-source arrays “look like” their truly continuous distributed source analogs. More generally, we find that the point-source array technique provides high source placement accuracy, relative ease of quantifying the true source configuration, scalability to source dimensions of ≲100 m, ease of reconfiguration and removal, and relatively low dose to personnel. Finally, we consider potential improvements and generalizations of the point-source array technique for future measurement campaigns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Variance-Reduced Accelerated First-Order Methods: Central Limit Theorems and Confidence Statements

In this paper, we consider a strongly convex stochastic optimization problem and propose three classes of variable sample-size stochastic first-order methods: (i) the standard stochastic gradient descent method, (ii) its accelerated variant, and (iii) the stochastic heavy-ball method. In each scheme, the exact gradients are approximated by averaging across an increasing batch size of sampled gradients. We prove that when the sample size increases at a geometric rate, the generated estimates converge in mean to the optimal solution at an analogous geometric rate for schemes (i)–(iii). Based on this result, we provide central limit statements, whereby it is shown that the rescaled estimation errors converge in distribution to a normal distribution with the associated covariance matrix dependent on the Hessian matrix, the covariance of the gradient noise, and the step length. If the sample size increases at a polynomial rate, we show that the estimation errors decay at a corresponding polynomial rate and establish the associated central limit theorems (CLTs). Under certain conditions, we discuss how both the algorithms and the associated limit theorems may be extended to constrained and nonsmooth regimes. As a result, we provide an avenue to construct confidence regions for the optimal solution based on the established CLTs and test the theoretical findings on a stochastic parameter estimation problem.

Lei, Jinlong↗

Numerical fluid dynamics for FRG flow equations: Zero-dimensional QFTs as numerical test cases. I. The O ( N ) model

The functional renormalization group (FRG) approach is a powerful tool for studies of a large variety of systems, ranging from statistical physics over the theory of the strong interaction to gravity. The practical application of this approach relies on the derivation of so-called flow equations, which describe the change of the quantum effective action under the variation of a coarse-graining parameter. In the present work, we discuss in detail a novel approach to solve such flow equations. This approach relies on the fact that RG equations can be rewritten such that they exhibit similarities with the conservation laws of fluid dynamics. This observation can be exploited in different ways. First of all, we show that this allows to employ powerful numerical techniques developed in the context of fluid dynamics to solve RG equations. In particular, it allows us to reliably treat the emergence of nonanalytic behavior in the RG flow of the effective action as it is expected to occur in studies of, e.g., spontaneous symmetry breaking. Second, the analogy between RG equations and fluid dynamics offers the opportunity to gain novel insights into RG flows and their interpretation in general, including the irreversibility of RG flows. Further, we work out this connection in practice by applying it to zero-dimensional quantum-field theoretical models. The generalization to higher-dimensional models is also discussed. Our findings are expected to help improving future FRG studies of quantum field theories in higher dimensions both on a qualitative and quantitative level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Validation of the TOPAS Monte Carlo toolkit for HDR brachytherapy simulations

The goal of this work is to validate the user-friendly Geant4-based Monte Carlo toolkit TOol for PArticle Simulation (TOPAS) for brachytherapy applications. Brachytherapy simulations performed with TOPAS were systematically compared with published TG-186 reference data. The photon emission energy spectrum, the air-kerma strength, and the dose-rate constant of the model-based dose calculation algorithm (MBDCA)-WG generic Ir-192 source were extracted. For dose calculations, a track-length estimator was implemented. Additionally, the four Joint AAPM/ESTRO/ABG MBDCA-WG test cases were evaluated through histograms of the local and global dose difference volumes. A prostate, a palliative lung, and a breast case were simulated. For each case, the dose ratio map, the histogram of the global dose difference volume, and cumulative dose-volume histograms were calculated. The air-kerma strength was (9.772 ± 0.001) × 10 -8 U Bq -1 (within 0.3% of the reference value). The dose-rate constant was 1.1107 ± 0.0005 cGy h -1 U -1 (within 0.01% of the reference value). For all cases, at least 96.9% of voxels had a local dose difference within [-1%, 1%] and at least 99.9% of voxels had a global dose difference within [-0.1%, 0.1%]. The implemented track-length estimator scorer was more efficient than the default analog dose scorer by a factor of 237. For all clinical cases, at least 97.5% of voxels had a global dose difference within [-1%, 1%]. Dose-volume histograms were consistent with the reference data. TOPAS was validated for high-dose-rate brachytherapy simulations following the TG-186 recommended approach for MBDCAs. Built on top of Geant4, TOPAS provides broad access to a state-of-the-art Monte Carlo code for brachytherapy simulations.

59 BASIC BIOLOGICAL SCIENCES↗

Controlled dehumidification to extract clean water from a multicomponent gaseous mixture of organic contaminants

Rapid expansion of the unconventional oil and gas extraction has increased American energy independence, but also led to increased production of large amounts of contaminated water. Wastewater from the oil and gas industry contains a wide range of contaminants. Injecting such contaminated water into disposal wells or discharging it to the environment jeopardizes freshwater resources. Conventional and membrane-based wastewater treatment techniques are often not effective choices to treat highly contaminated wastewater; however, a suitable way to remove contaminants from wastewater is to selectively separate water in a process analogous to humidification-dehumidification (HDH). Only a few studies have investigated the use of HDH for wastewater treatment. In this study, a novel HDH system is introduced for treating highly contaminated water, such as oil and gas flowback and produced water. In this HDH process, a non-condensable gas, such as air, mixes with wastewater vapor to facilitate the separation of contaminants. As a result, clean water condenses from the multicomponent gaseous mixture while air carries organic contaminants out of the dehumidification section. A laboratory apparatus was constructed and experiments were performed to investigate the HDH process for wastewater treatment and to study the effects of flow dynamics including air flow rate on the composition of treated water. Different contaminants including benzene, toluene, 2-propanol and 2-butoxyethanol were tested. Experimental results showed that the system can be successfully applied for removing volatile and/or toxic organic contaminants from wastewater. A representative multicomponent mixture of fracking wastewater was successfully treated using the experimental setup and clean water with quality of 98.3% was obtained. It was revealed that increasing the air-to-vapor mass ratio improves purity of treated water. Quantitative analysis showed that by increasing the air-to-vapor mass ratio from 0.6 to 5.9, the fraction of separated 2-propanol through the air was improved from 43% to more than 96% of the initial amount. ASPEN software was employed to simulate equilibrium conditions. Finally, experimental results were observed to have lower mass fraction of residual contaminant in the treated water compared to equilibrium state.

42 ENGINEERING↗

Passive Digital Sensing Method and Its Implementation on Passive RFID Temperature Sensors

Benefitting from the advancement of digital electronics in the 20 th century, sensors have also gradually evolved from analog to digital. As semiconductor components are required in digital sensors, a power supply is still needed for the sensor. To eliminate the need for a power supply a concept of passive digital sensing is proposed. Different from the semiconductor-based electrical digital sensing method, the parameter to be measured is first converted to a mechanical signal, then the mechanical signal is encoded to multiple digital bits by a passive digitizer, where each bit is identified as open or short state that is detectable by general IO ports. To demonstrate the proposed sensing concept, a passive RFID temperature sensor is implemented using a bimetallic coil as the temperature sensing unit. The 6-bit binary codes are acquired and transmitted by a passive RFID that is powered by an energy harvester. Furthermore, the test results show that the temperature sensor has a measurement sensitivity of 1.32 °C/bit and a working distance over 10 meters.

47 OTHER INSTRUMENTATION↗

Analysis of Long-Term Quality Control Data for a 137 Cs Dosimetry Calibration Source

Strict quality assurance programs are required for many radiological applications, but these seldom exist for verifying dosimetry calibration sources. After initial characterization of a dosimetry calibration facility, quality control procedures are recommended to ensure the early detection of any changes or malfunctions. These also result in refined knowledge about average dose rate and experimental variations in dose delivery. This paper describes the implementation of a phase I quality control protocol for a 137 Cs dosimetry calibration source and includes an analysis of the resulting data collected over a 24-mo period. During this time, substantial data was collected to establish trial control limits. Air kerma rate measurements were obtained using an ion chamber and were adjusted for decay, corrected for ambient temperature, pressure and humidity, and then analyzed using quality control charts. Three variations of rational subgrouping methods were used in order to find assignable causes of error, and Nelson's Rules were followed to detect any non-random statistical variations. Measurements were subgrouped according to same-day measurements in order to detect positional errors as well as atmospheric correction errors. Additionally, measurements were subgrouped according to analogous experimental setups in order to detect failure in equipment or incorrect settings. Both were analyzed using the X-bar and R chart method. Similarly, individuals and moving ranges charts were used to carefully examine each position in order to observe any situational errors that may occur which include timing, positional, or interference errors. Each method was successful in identifying unique out-of-control data points that occurred during the phase I application of forming control limits. Furthermore, over the 24-mo period, enough data points were deemed in-control to establish reliable trial limits. Future experiments will include the phase II application of gaining more reliable measurements in order to fine-tune the limits, as well as performing a designed experiment, where variables are purposefully changed in order to test the variation of the data.

61 RADIATION PROTECTION AND DOSIMETRY↗