Sampling and Analysis Plan for TRU Liquid Waste Facility Soil

The Radioactive Liquid Waste Treatment Facility Upgrade Project (RLWTF-UP) will relocate, upgrade, and consolidate existing treatment capabilities that are currently housed in the Radioactive Liquid Waste Treatment Facility (RLWTF) at Technical Area 50, Building 001 (TA-50-001).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Systems analysis of a potential space manufacturing facility

Results of a preliminary design study of the system elements comprising a manufacturing facility in earth orbit are presented. The elements discussed include cis-Lunar transportation, Lunar base, materials transport, factory, living facilities, construction support and energy supply. An evolutionary path of development, production and deployment is presented and step-wise interrelationships discussed.

Driggers, G. W.↗

The design and instrumentation of the Purdue annular cascade facility with initial data acquisition and analysis

Three dimensional aerodynamic data, required to validate and/or indicate necessary refinements to inviscid and viscous analyses of the flow through turbomachine blade rows, are discussed. Instrumentation and capabilities for pressure measurement, probe insertion and traversing, and flow visualization are reviewed. Advanced measurement techniques including Laser Doppler Anemometers, are considered. Data processing is reviewed. Predictions were correlated with the experimental data. A flow visualization technique using helium filled soap bubbles was demonstrated.

Stauter, R. C.↗

Superfluid-supercritical helium tradeoff analysis for the Shuttle Infrared Telescope Facility (SIRTF)

A comparative study is made of three methods for obtaining the required cooling of the SIRTF. The first is a supercritical helium system in which the 2 K temperatures are obtained by a Joule-Thomson expander; the second is a superfluid (He II) helium system; and the third is a hybrid system in which supercritical helium provides the major cooling and small He II reservoirs supply specific detector cooling. The superfluid helium system is found to offer superior performance; it would be the system to use if funding were available. The comparative study gives equal weight to performance, operations, and cost. From this point of view, the hybrid system is selected as the best compromise to obtain an operational SIRTF.

Gier, H. L.↗

Summary of ionizing radiation analysis on the Long Duration Exposure Facility

The ionizing radiation measurements flown on the Long Duration Exposure Facility (LDEF) were contained in 15 experiments which utilized passive detectors to pursue objectives in astrophysics and to measure the radiation environment and dosimetric quantities. The spacecraft structure became sufficiently radioactive to permit additional important studies. The induced activity allows extensive radiation mapping in the structure, and independent comparison with experiment dosimetric techniques, and significant studies of secondary effects. The long exposure time, attitude stability, and number and types of measurements produced a unique and critical set of data for low Earth orbit that will not be duplicated for more than a decade. The data allow an unprecedented test, and improvement if required, of models of the radiation environment and the radiation transport methods that are used to calculate the internal radiation and its effects in spacecraft. Results of measurements in the experiments, as well as from radioactivity in the structure, have clearly shown effects from the directional properties of the radiation environment, and progress was made in the dosimetric mapping of LDEF. These measurements have already influenced some Space Station Freedom design requirements. Preliminary results from experiments, reported at this symposium and in earlier papers, show that the 5.8 years exposure considerably enhanced the scientific return of the radiation measurements. The early results give confidence that the experiments will make significant advances in the knowledge of ultra heavy cosmic rays, anomalous cosmic rays, and heavy ions trapped in the radiation belts. Unexpected phenomena were observed, which require explanation. These include stopping iron group ions between the energy ranges anticipated for anomalous and galactic cosmic rays in the LDEF orbit. A surprising concentration of the Be-7 nuclide was discovered on the 'front' surface of LDEF, apparently transported up from the stratosphere with exceptional efficiency.

Parnell, T. A.↗

Test Based Microgravity Analysis for the Fluids and Combustion Facility

The Fluids and Combustion Facility (FCF) is a two rack facility dedicated to combustion and fluids science in a microgravity (near zero-g) environment on board the International Space Station (ISS). An important aspect of performing on-orbit research is maintaining the rack microgravity environment by minimizing vibroacoustic disturbances generated within the science payload. This paper discusses recent rack-level acoustic emission testing to characterize the science payload microgravity environment. Measurements are compared with FCF microgravity science requirements.

McNelis, Mark E.↗

Three Dimensional Structures of Particles Recovered from the Asteroid Itokawa by the Hayabusa Mission and a Role of X-Ray Microtomography in the Preliminary Examination

Particles of regolith on S-type Asteroid 25143 Itokawa were successfully recovered by the Hayabusa mission of JAXA (Japan Aerospace Exploration Agency). Near-infrared spectral study of Itokawa s surface indicates that these particles are materials similar to LL5 or LL6 chondrites. High-resolution images of Itokawa's surface suggest that they may be breccias and some impact products. At least more than 1500 particles were identified as Itokawa origin at curation facility of JAXA. Preliminary analysis with SEM/EDX at the curation facility shows that they are roughly similar to LL chondrites. Although most of them are less than 10 micron in size, some larger particles of about 100 micron or larger were also identified. A part of the sample (probably several tens particles) will be selected by Hayabusa sample curation team, and sequential examination will start from January 2011 by Hayabusa Asteroidal Sample Preliminary Examination Team (HASPET). In mainstream of the analytical flow, each particle will be examined by microtomography, XRD and XRF first as nondestructive analyses, and then the particle will be cut by an ultra-microtome and examined by TEM, SEM, EPMA, SIMS, PEEM/XANES, and TOF-SIMS sequentially. Three-dimensional structures of Itokawa particles will be obtained by microtomography sub-team of HASPET. The results together with XRD and XRF will be used for design of later destructive analyses, such as determination of cutting direction and depth, to obtain as much information as possible from small particles. Scientific results and a role of the microtomography in the preliminary examination will be presented.

Tsuchiyama, A.↗

Contamination Impact of Station Brush Fire on Cleanroom Facilities

Brush and forest fires, both naturally occurring and anthropogenic in origin, in proximity to space flight hardware processing facilities raise concerns about the threat of contamination resulting from airborne particulate and molecular components of smoke. Perceptions of the severity of the threat are possibly heightened by the high sensitivity of the human sense of smell to some components present in the smoke of burning vegetation.On August 26th, 2009, a brushfire broke out north of Pasadena, California, two miles from the Jet Propulsion Laboratory. The Station Fire destroyed over 160,000 acres, coming within a few hundred yards of JPL. Smoke concentrations on Lab were very heavy over several days. All Lab operations were halted, and measures were taken to protect personnel, critical hardware, and facilities. Evaluation of real-time cleanroom monitoring data, visualinspection of facilities, filter systems, and analysis of surface cleanliness samples revealed facility environments andhardware were minimally effected.Outside air quality easily exceeded Class Ten Million. Prefilters captured most large ash and soot; multi-stage filtration greatly minimized the impact on the HEPA/ULPA filters. Air quality in HEPA filtered spacecraft assembly cleanrooms remained within Class 10,000 specification throughout. Surface cleanliness was inimally affected, as large particles were effectively removed from the airstream, and sub-micron particles have extremely long settling rates. Approximate particulate fallout within facilities was 0.00011% area coverage/day compared to 0.00038% area coverage/day during normal operations. Deposition of condensable airborne components, as measured in real time, peaked at approximately1.0 ng/cm2/day compared to 0.05 ng/cm2/day nominal.

airborne particulate contamination↗

An Overview of the Patch Integral Method (PIM), a New Heat Transfer Analysis Tool for Hypersonic Wind Tunnel Facilities at NASA Langley

NASA Langley’s hypersonic wind tunnels are heavily leveraged for planetary missions. The data collection method in these tunnels is thermography, and surface temperature measurements of the model surface are collected and reduced to produce surface heating data, as seen in Fig 1. However, during model injection, no temperature data are collected, and thus conventional, integral heat transfer methods cannot be used to solve for surface heating. A method was developed in the 1990’s to reduce this data despite the data gap, known as the step approximation method. The method assumes that the film coefficient behaves as a step function, the model is semi-infinite, and thermal properties are constant. With these simplifying assumptions, a Laplace transform can be performed to result in an equation that takes the initial temperature of the model and a temperature at some point in time to back out the film coefficient at that time. This is the method that is used in the current thermographic data reduction software, IHEAT. While computationally light-weight, the step approximation has several issues associated with it. The time-history of temperature is not accounted for, which is vital as heat transfer is an integral process. Additionally, the required semi-infinite assumption is unnecessary and might be violated during runtime. Thermal variation of material properties can have a sizeable impact on heating results and are not modeled by the method. This method also takes multiple seconds to “collapse” to a steady state, which is undesirable from both a facility and data reduction standpoint. The method is also very sensitive to the “effective time” approximation, an approximation of when heating instantaneously starts (which is a nonphysical simplification), and a small variation in this value can result in an error in heating results.

J. S. Cheatwood↗

Contamination Sources Effects Analysis (CSEA) - A Tool to Balance Cost/Schedule While Managing Facility Availability

A CSEA is similar to a Failure Modes Effects Analysis (FMEA). A CSEA tracks risk, deterrence, and occurrence of sources of contamination and their mitigation plans. Documentation is provided spanning mechanical and electrical assembly, precision cleaning, thermal vacuum bake-out, and thermal vacuum testing. These facilities all may play a role in contamination budgeting and reduction ultimately affecting test and flight. With a CSEA, visibility can be given to availability of these facilities, test sequencing and trade-offs. A cross-functional team including specialty engineering, contamination control, electrostatic dissipation, manufacturing, testing, and material engineering participate in an exercise that identifies contaminants and minimizes the complexity of scheduling these facilities considering their volatile schedules. Care can be taken in an efficient manner to insure correct cleaning processes are employed. The result is reduction in cycle time ("schedule hits"), reduced cost due to rework, reduced risk and improved communication and quality while achieving adherence to the Contamination Control Plan.

Wilcox, Margaret↗

Computational Analysis of Arc-Jet Wedge Tests Including Ablation and Shape Change

Coupled fluid-material response analyses of arc-jet wedge ablation tests conducted in a NASA Ames arc-jet facility are considered. These tests were conducted using blunt wedge models placed in a free jet downstream of the 6-inch diameter conical nozzle in the Ames 60-MW Interaction Heating Facility. The fluid analysis includes computational Navier-Stokes simulations of the nonequilibrium flowfield in the facility nozzle and test box as well as the flowfield over the models. The material response analysis includes simulation of two-dimensional surface ablation and internal heat conduction, thermal decomposition, and pyrolysis gas flow. For ablating test articles undergoing shape change, the material response and fluid analyses are coupled in order to calculate the time dependent surface heating and pressure distributions that result from shape change. The ablating material used in these arc-jet tests was Phenolic Impregnated Carbon Ablator. Effects of the test article shape change on fluid and material response simulations are demonstrated, and computational predictions of surface recession, shape change, and in-depth temperatures are compared with the experimental measurements.

Goekcen, Tahir↗

Guide for Oxygen Hazards Analyses on Components and Systems

Because most materials, including metals, will burn in an oxygen-enriched environment, hazards are always present when using oxygen. Most materials will ignite at lower temperatures in an oxygen-enriched environment than in air, and once ignited, combustion rates are greater in the oxygen-enriched environment. Many metals burn violently in an oxygen-enriched environment when ignited. Lubricants, tapes, gaskets, fuels, and solvents can increase the possibility of ignition in oxygen systems. However, these hazards do not preclude the use of oxygen. Oxygen may be safely used if all the materials in a system are not flammable in the end-use environment or if ignition sources are identified and controlled. These ignition and combustion hazards necessitate a proper oxygen hazards analysis before introducing a material or component into oxygen service. The objective of this test plan is to describe the White Sands Test Facility oxygen hazards analysis to be performed on components and systems before oxygen is introduced and is recommended before implementing the oxygen component qualification procedure. The plan describes the NASA Johnson Space Center White Sands Test Facility method consistent with the ASTM documents for analyzing the hazards of components and systems exposed to an oxygen-enriched environment. The oxygen hazards analysis is a useful tool for oxygen-system designers, system engineers, and facility managers. Problem areas can be pinpointed before oxygen is introduced into the system, preventing damage to hardware and possible injury or loss of life.

Stoltzfus, Joel M.↗

Reliability and Maintainability Analysis of a High Air Pressure Compressor Facility

This paper discusses a Reliability, Availability, and Maintainability (RAM) independent assessment conducted to support the refurbishment of the Compressor Station at the NASA Langley Research Center (LaRC). The paper discusses the methodologies used by the assessment team to derive the repair by replacement (RR) strategies to improve the reliability and availability of the Compressor Station (Ref.1). This includes a RAPTOR simulation model that was used to generate the statistical data analysis needed to derive a 15-year investment plan to support the refurbishment of the facility. To summarize, study results clearly indicate that the air compressors are well past their design life. The major failures of Compressors indicate that significant latent failure causes are present. Given the occurrence of these high-cost failures following compressor overhauls, future major failures should be anticipated if compressors are not replaced. Given the results from the RR analysis, the study team recommended a compressor replacement strategy. Based on the data analysis, the RR strategy will lead to sustainable operations through significant improvements in reliability, availability, and the probability of meeting the air demand with acceptable investment cost that should translate, in the long run, into major cost savings. For example, the probability of meeting air demand improved from 79.7 percent for the Base Case to 97.3 percent. Expressed in terms of a reduction in the probability of failing to meet demand (1 in 5 days to 1 in 37 days), the improvement is about 700 percent. Similarly, compressor replacement improved the operational availability of the facility from 97.5 percent to 99.8 percent. Expressed in terms of a reduction in system unavailability (1 in 40 to 1 in 500), the improvement is better than 1000 percent (an order of magnitude improvement). It is worthy to note that the methodologies, tools, and techniques used in the LaRC study can be used to evaluate similar high value equipment components and facilities. Also, lessons learned in data collection and maintenance practices derived from the observations, findings, and recommendations of the study are extremely important in the evaluation and sustainment of new compressor facilities.

Safie, Fayssal M.↗

Error budget analysis for advanced X-ray Astrophysics Facility (AXAF)

The AXAF telescope was analytically investigated during the period from September 1979 to March 1980. The results of a performance evaluation in the presence of aligment errors and surface defects, a sensitivity analysis of every individual subsystem, and a diffraction analysis of the telescope assembly are presented.

Korsch, D.↗

Uncertainty Analysis of the CE-12 Free-Jet Probe Calibration Facility

This paper presents methods and results of a detailed measurement uncertainty analysis thf at was performed for the Free Jet Calibration Facility (CE-12) located at the NASA Glenn Research Center. Results for systematic uncertainty estimates in a number of fluid properties of the free jet flow are presented. Systematic uncertainty captures inaccuracies due to measurement process, calibration, installation effects or other similar sources which may introduce bias. MANTUS (Measurement Analysis Tool for Uncertainty in Systems) was used to quantify instrumentation uncertainty and engineering judgment was used to quantify other systematic uncertainty sources. The Monte Carlo method was used to propagate systematic uncertainties to determine the uncertainties of various calculated variables of interest.

CE-12↗

Analysis of vibrations of the National Transonic Facility model support system using a 3-D aeroelastic code

Vibrations of the National Transonic Facility model support system were analyzed using Computational Aeroelasticity Program-Transonic Small Disturbance, a three-dimensional transonic small disturbance code designed for aeroelastic analysis of complete aircraft. The model support system was represented as a tunnel-spanning flexible wing whose structural properties were obtained from measured responses. Aeroelastic transients were calculated and analyzed to obtain modal stability characteristics. The results show that there is tendency to exhibit a hump mode instability in one of the modes, and that there are other weakly damped or unstable modes. Most of the motion is in the aft section of the model support system. The close proximity of the solid wind-tunnel diffuser side walls to the model support system is shown to have adverse effects on its aeroelastic stability characteristics. When the effects of the wind-tunnel walls are modeled, the analyses indicate the presence of wind-tunnel resonance modes which are not present when free-air boundary conditions are used.

Whitlow, Woodrow, Jr.↗

Application of Landsat data to wetland study and land use classification in West Tennessee

Landsat data were employed in determining land use of a 32,300-hectare watershed area within the Obion-Forked Deer River Basin in northwest Tennessee. Black and white transparency chips for all four wavelength bands were interpreted by use of a video-input analog/digital automatic analysis and classification facility; densitometric methods showed that wetlands, urban areas, agricultural lands and forests could be discriminated by analysis of band 6 or 7 together with band 4 or 5. Comparison with high- and low-altitude photography indicated that the Landsat data could provide sufficiently accurate resource information and determine drainage trends.

Jones, N. L.↗