Nocturnal Aerosol Optical Depth Measurements with a Small-Aperture Automated Photometer Using the Moon as a Light Source

A method is described that enables the use of lunar irradiance to obtain nighttime aerosol optical depth (AOD) measurements using a small-aperture photometer. In this approach, the U.S. Geological Survey lunar calibration system was utilized to provide high-precision lunar exoatmospheric spectral irradiance predictions for a ground-based sensor location, and when combined with ground measurement viewing geometry, provided the column optical transmittance for retrievals of AOD. Automated multiwavelength lunar measurements were obtained using an unmodified Cimel-318 sunphotometer sensor to assess existing capabilities and enhancements needed for day/night operation in NASA s Aerosol Robotic Network (AERONET). Results show that even existing photometers can provide the ability for retrievals of aerosol optical depths at night near full moon. With an additional photodetector signal-to-noise improvement of 10-100, routine use over the bright half of the lunar phase and a much wider range of wavelengths and conditions can be achieved. Although the lunar cycle is expected to limit the frequency of observations to 30%-40% compared to solar measurements, nevertheless this is an attractive extension of AERONET capabilities.

Berkoff, Timothy A.↗

Calibration Issues and Operating System Requirements for Electron-Probe Microanalysis

Instrument purchase requirements and dialogue with manufacturers have established hardware parameters for alignment, stability, and reproducibility, which have helped improve the precision and accuracy of electron microprobe analysis (EPMA). The development of correction algorithms and the accurate solution to quantitative analysis problems requires the minimization of systematic errors and relies on internally consistent data sets. Improved hardware and computer systems have resulted in better automation of vacuum systems, stage and wavelength-dispersive spectrometer (WDS) mechanisms, and x-ray detector systems which have improved instrument stability and precision. Improved software now allows extended automated runs involving diverse setups and better integrates digital imaging and quantitative analysis. However, instrumental performance is not regularly maintained, as WDS are aligned and calibrated during installation but few laboratories appear to check and maintain this calibration. In particular, detector deadtime (DT) data is typically assumed rather than measured, due primarily to the difficulty and inconvenience of the measurement process. This is a source of fundamental systematic error in many microprobe laboratories and is unknown to the analyst, as the magnitude of DT correction is not listed in output by microprobe operating systems. The analyst must remain vigilant to deviations in instrumental alignment and calibration, and microprobe system software must conveniently verify the necessary parameters. Microanalysis of mission critical materials requires an ongoing demonstration of instrumental calibration. Possible approaches to improvements in instrument calibration, quality control, and accuracy will be discussed. Development of a set of core requirements based on discussions with users, researchers, and manufacturers can yield documents that improve and unify the methods by which instruments can be calibrated. These results can be used to continue improvements of EPMA.

Carpenter, P.↗

SIDDA: SInkhorn Dynamic Domain Adaptation for image classification with equivariant neural networks

Modern neural networks (NNs) often do not generalize well in the presence of a ‘covariate shift’; that is, in situations where the training and test data distributions differ, but the conditional distribution of classification labels given the data remains unchanged. In such cases, NN generalization can be reduced to a problem of learning more robust, domain-invariant features. Domain adaptation (DA) methods include a broad range of techniques aimed at achieving this; however, these methods have struggled with the need for extensive hyperparameter tuning, which then incurs significant computational costs. In this work, we introduce SInkhorn Dynamic Domain Adaptation (SIDDA), an out-of-the-box DA training algorithm built upon the Sinkhorn divergence, that can achieve effective domain alignment with minimal hyperparameter tuning and computational overhead. We demonstrate the efficacy of our method on multiple simulated and real datasets of varying complexity, including simple shapes, handwritten digits, real astronomical observations, and remote sensing data. These datasets exhibit covariate shifts due to noise, blurring, differences between telescopes, and variations in imaging wavelengths. SIDDA is compatible with a variety of NN architectures, and it works particularly well in improving classification accuracy and model calibration when paired with symmetry-aware equivariant NNs (ENNs). We find that SIDDA consistently enhances the generalization capabilities of NNs, achieving up to a ${\approx}40\%$ improvement in classification accuracy on unlabeled target data, while also providing a more modest performance gain of $\lesssim 1\%$ on labeled source data. We also study the efficacy of DA on ENNs with respect to the varying group orders of the dihedral group DN, and find that the model performance improves as the degree of equivariance increases. Finally, if SIDDA achieves proper domain alignment, it also enhances model calibration on both source and target data, with the most significant gains in the unlabeled target domain—achieving over an order of magnitude improvement in the expected calibration error and Brier score. SIDDA’s versatility across various NN models and datasets, combined with its automated approach to domain alignment, has the potential to significantly advance multi-dataset studies by enabling the development of highly generalizable models.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-point bridge calibration with one resistor

Method calibrates transducer bridge curing unbalanced condition and line resistance errors are negligible. Series resistance method can be automated easily and controlled by 2-bit information source which provide 4 states for switches.

Harrison, D. R.↗

Automated delay measurement system for an Earth station for Two-Way Satellite Time and Frequency Transfer

The measurement of the difference of the transmit and receive delays of the signals in a Two-Way Satellite Time and Frequency Transfer (TWSTFT) Earth station is crucial for its nanosecond time transfer capability. Also, the monitoring of the change of this delay difference with time, temperature, humidity, or barometric pressure is important for improving the TWSTFT capabilities. An automated system for this purpose has been developed from the initial design at NMi-VSL. It calibrates separately the transmit and receive delays in cables, amplifiers, upconverters and downconverters, and antenna feeds. The obtained results can be applied as corrections to the TWSTFT measurement when, before and after a measurement session, a calibration session is performed. Preliminary results obtained at NMi-VSL will be shown. Also, if available, the results of a manual version of the system that is planned to be circulated in Sept. 1994 together with a USNO portable station on a calibration trip to European TWSTFT Earth stations.

Dejong, Gerrit↗

Designing and Training for Appropriate Trust in Increasingly Autonomous Advanced Air Mobility Operations: A Mental Model Approach: Version 1

To enable effective human-autonomy teaming (HAT) in Advanced Air Mobility (AAM) operations, the current paper presents a theoretical framework to design and train for appropriate trust in automation. The novel contribution of this work resides in connecting the construct of trust to mental models and showing how this method could be used to enable emerging HAT concepts such as Adaptive Trust Calibration. To contextualize this framework, in section 2 we discuss simplified vehicle operations (SVO) and remote vehicle operations (RVO), which are leading operational concepts within AAM. In section 3 we describe our perspective on automation and increasingly autonomous systems and present a brief discussion on human-automation interaction and human-autonomy teaming. In section 4 we provide a detailed discussion on the construct of trust in automation. In section 5 we present a framework that associates mental models with trust through principles of transparent design. Finally, in section 6 we present three descriptive models for designing and training for appropriate trust in increasingly autonomous systems.

Human-Autonomy Teaming↗

Liquid Bismuth Feed System for Electric Propulsion

Operation of Hall thrusters with bismuth propellant has been shown to be a promising path toward high-power, high-performance, long-lifetime electric propulsion for spaceflight missions. For example, the VHITAL project aims td accurately, experimentally assess the performance characteristics of 10 kW-class bismuth-fed Hall thrusters - in order to validate earlier results and resuscitate a promising technology that has been relatively dormant for about two decades. A critical element of these tests will be the precise metering of propellant to the thruster, since performance cannot be accurately assessed without an accurate accounting of mass flow rate. Earlier work used a pre/post-test propellant weighing scheme that did not provide any real-time measurement of mass flow rate while the thruster was firing, and makes subsequent performance calculations difficult. The motivation of the present work was to develop a precision liquid bismuth Propellant Management System (PMS) that provides real-time propellant mass flow rate measurement and control, enabling accurate thruster performance measurements. Additionally, our approach emphasizes the development of new liquid metal flow control components and, hence, will establish a basis for the future development of components for application in spaceflight. The design of various critical components in a bismuth PMS are described - reservoir, electromagnetic pump, hotspot flow sensor, and automated control system. Particular emphasis is given to material selection and high-temperature sealing techniques. Open loop calibration test results are reported, which validate the systems capability to deliver bismuth at mass flow rates ranging from 10 to 100 mg/sec with an uncertainty of less than +/- 5%. Results of integrated vaporizer/liquid PMS tests demonstrate all of the necessary elements of a complete bismuth feed system for electric propulsion.

Markusic, T. E.↗

The fast camera (Fastcam) imaging diagnostic systems on the DIII-D tokamak

Two camera systems are installed on the DIII-D tokamak at the toroidal positions of 90° (90° system) and 225° (225° system), respectively. The cameras have two types of relay optics, namely, a coherent optical fiber bundle and a periscope system. The periscope system provides absolute intensity calibration stability while sacrificing resolution (10 lp/mm), while the fiber system provides high resolution (16 lp/mm) while sacrificing calibration stability. The periscope is available only for the 90° system. The optics of the 225° system were designed for view stability, repeatability, and easy maintenance. The cameras are located inside optimized neutron, x ray and magnetic shielding in order to reduce electronics damage, reboots, and magnetic and neutron interference, increasing the overall system reliability. An automated filter wheel, providing remote filter change, allows for remote wavelength selection. A software suite automates camera acquisition and data storage, allowing for remote operation and reduced operator involvement. System metadata is used to streamline the data analysis workflow, particularly for intensity calibration. Here, the spatial calibration uses multiple observable wall features, resulting in a reconstruction accuracy ≤2 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Inter-Calibration of the DSCOVR EPIC Imager 2 with Aqua-MODIS and NPP-VIIRS

The Deep Space Climate Observatory (DSCOVR) Earth Polychromatic Imaging Camera (EPIC) continuously observes the illuminated disk from the Lagrange-1 point. The EPIC sensor was designed to monitor the diurnal variation of ozone, clouds, aerosols, and vegetation, especially those features that benefit from observation near-backscatter conditions. The EPIC sensor does not contain any onboard calibration systems. This study describes the inter-calibration of EPIC channels 5 (0.44 μm), 6 (0.55 μm), 7 (0.68 μm), and 10 (0.78 μm) with respect to Aqua-MODIS and NPP-VIIRS. The calibration is transferred using coincident ray-matched reflectance pairs over all-sky tropical ocean (ATO) and deep convective cloud (DCC) targets. A robust and automated image-alignment technique based on feature matching was formulated to improve the navigation quality of the EPIC images. The EPIC V02 dataset exhibits improved navigation over V01. Because the visible channels display similar spatial features, a single visible channel can be used to co-register the remaining visible bands. The VIIRS-referenced EPIC ATO and DCC ray-matched calibration coefficients are within 0.3%. The EPIC four-year calibration trends based on VIIRS are within 0.15%/year. The MODIS-based EPIC calibration coefficients were compared against the Geogdzhayev and Marshak 2018 published calibration coefficients and are found to be within 1.6%.

DSCOVR↗

Automated electronic system for measuring thermophysical properties

Phase-charge coatings are used to measure surface temperature accurately under transient heating conditions. Coating melts when surface reaches calibrated phase-charge temperature. Temperature is monitored by infrared thermometer, and corresponding elapsed time is recorded by electronic data-handling system.

Creel, T. R., Jr.↗

Experimental Calibration of a Numerical Model of Prepreg Tack for Predicting AFP Process Related Defects

Wrinkles, puckers, and fiber bridging are among the major defects encountered in the Automated Fiber Placement (AFP) process, and are all different manifestations of fiber misalignment. The main driver for these defects are the residual stresses introduced in the tow during the deposition stage by the AFP head. In contrast, the tack between the deposited tape and the substrate is the resisting force against the formation of such defects. Tack may be defined as the ability of a material to form a bond immediately on contact with another surface. Tack is a very complex phenomenon that is influenced by a variety of process parameters including temperature, head pressure and speed, as well as degree of cure, moisture content, and surface roughness A physics-based modeling framework for simulation of tack was developed in this study that allows for prediction of tack response. The developed tack model is incorporated in the AFP placement modelling framework developed to simulate AFP defects.

Forghani, Alireza↗

Deep learning uncertainty quantification for clinical text classification

Machine learning algorithms are expected to work side-by-side with humans in decision-making pipelines. Thus, the ability of classifiers to make reliable decisions is of paramount importance. Deep neural networks (DNNs) represent the state-of-the-art models to address real-world classification. Although the strength of activation in DNNs is often correlated with the network’s confidence, in-depth analyses are needed to establish whether they are well calibrated. In this paper, we demonstrate the use of DNN-based classification tools to benefit cancer registries by automating information extraction of disease at diagnosis and at surgery from electronic text pathology reports from the US National Cancer Institute (NCI) Surveillance, Epidemiology, and End Results (SEER) population-based cancer registries. In particular, we introduce multiple methods for selective classification to achieve a target level of accuracy on multiple classification tasks while minimizing the rejection amount—that is, the number of electronic pathology reports for which the model’s predictions are unreliable. We evaluate the proposed methods by comparing our approach with the current in-house deep learning-based abstaining classifier. Overall, all the proposed selective classification methods effectively allow for achieving the targeted level of accuracy or higher in a trade-off analysis aimed to minimize the rejection rate. On in-distribution validation and holdout test data, with all the proposed methods, we achieve on all tasks the required target level of accuracy with a lower rejection rate than the deep abstaining classifier (DAC). Interpreting the results for the out-of-distribution test data is more complex; nevertheless, in this case as well, the rejection rate from the best among the proposed methods achieving 97% accuracy or higher is lower than the rejection rate based on the DAC. We show that although both approaches can flag those samples that should be manually reviewed and labeled by human annotators, the newly proposed methods retain a larger fraction and do so without retraining—thus offering a reduced computational cost compared with the in-house deep learning-based abstaining classifier.

59 BASIC BIOLOGICAL SCIENCES↗

High-Resolution Image Products Acquired from Mid-Sized Uncrewed Aerial Systems for Land–Atmosphere Studies

We assess the viability of deploying commercially available multispectral and thermal imagers designed for integration on small uncrewed aerial systems (sUASs, <25 kg) on a mid-size Group-3-classification UAS (weight: 25–600 kg, maximum altitude: 5486 m MSL, maximum speed: 128 m/s) for the purpose of collecting a higher spatial resolution dataset that can be used for evaluating the surface energy budget and effects of surface heterogeneity on atmospheric processes than those datasets traditionally collected by instrumentation deployed on satellites and eddy covariance towers. A MicaSense Altum multispectral imager was deployed on two very similar mid-sized UASs operated by the Atmospheric Radiation Measurement (ARM) Aviation Facility. This paper evaluates the effects of flight on imaging systems mounted on UASs flying at higher altitudes and faster speeds for extended durations. We assess optimal calibration methods, acquisition rates, and flight plans for maximizing land surface area measurements. We developed, in-house, an automated workflow to correct the raw image frames and produce final data products, which we assess against known spectral ground targets and independent sources. We intend this manuscript to be used as a reference for collecting similar datasets in the future and for the datasets described within this manuscript to be used as launching points for future research.

47 OTHER INSTRUMENTATION↗

Image processing in optical astronomy

Successful efforts to enhance optical-astronomy images through digital processing often exploit such 'weaknesses' of the image as the objects' near-symmetry, their preferred directionality, or a differentiation in spatial frequency between the object or objects and superimposed clutter. Attention is presently given to the calibration of a camera prior to astronomical data-acquisition, methods for the enhancement of faint surface brightness features, automated target detection and extraction techniques, the importance of the geometric transformations of digital imagery, the preparation of two-dimensional histograms, and the application of polarization.

Lorre, Jean J.↗

The MISR Calibration Program

The Multiangle Imaging SpectroRadiometer (MISR) is currently under development for NASA's Earth Observing System. The instrument consists of nine pushbroom cameras, each with four spectral bands in the visible and near-infrared. The cameras point in different view directions to provide measurements from nadir to highly oblique view angles in the along-track plane. Multiple view-angle observations provide a unique resource for studies of clouds, aerosols, and the surface. MISR is built to challenging radiometric and geometric performance specifications. Radiometric accuracy, for example, must be within +/- 3%/ 1 sigma, and polarization insensitivity must be better than +/- 1 %. An onboard calibrator (OBC) provides monthly updates to the instrument gain coefficients. Spectralon diffuse panels are used within the OBC to provide a uniform target for the cameras to view. The absolute radiometric scale is established both preflight and in orbit through the use of detector standards. During the mission, ground data processing to accomplish radiometric calibration, geometric rectification and registration of the nine view-angle imagery, and geophysical retrievals will proceed in an automated fashion. A global dataset is produced every 9 days. This paper details the preflight characterization of the MISR instrument, the design of the OBC, and the radiance product processing.

Bruegge, Carol J.↗

Milone eTape Liquid Level Sensor Laboratory Calibration with a Commercial 12.2 cm HS-Flume and 3D Printed 4 cm Micro-HS-Flumes

The NGEE Arctic Rainfall Simulator (NARS) is a variable intensity rainfall simulator (RFS) with a frame design based on the Humphry et al. (2002) RFS and a water delivery system based on the Walnut Gulch (Paige et al., 2004) RFS. The NARS uses an aluminum frame that is fully deconstructable for transportation to field locations and a water system that enables variable rain intensity. Prior to field deployment, H-flume discharge and the corresponding Milone eTape Liquid Level Sensor (eTape) resistance values were measured in the laboratory so that discharge measurements from the NGEE Arctic Rainfall Simulator could be automated. eTape resistance was measured with increasing fluid heights for the full range of the eTape to calculate sensor detection limits and resolution. The eTape was calibrated to both a commercially available 12.2 cm HS-flume and a 3D printed 4 cm Micro-HS-flume. This data package contains two .csv files, one for the eTape calibration and the other for the flume calibrations, and two .stl files to 3D print the 4 cm Micro-HS-Flume design with a 1 cm x 3.6 cm stilling well opening. The .stl files can be opened in most 3D printing or CAD programs/software. Two .kml files of the laboratory location and broader area where testing was conducted are also included in this data package.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Development of a drift-correction procedure for a direct-reading spectrometer

A procedure which provides automatic correction for drifts in the radiometric sensitivity of each detector channel in a direct-reading emission spectrometer is described. Such drifts are customarily controlled by the regular analyses of standards, which provide corrections for changes in the excitational, optical, and electronic components of the instrument. This standardization procedure, however, corrects for the optical and electronic drifts. It is a step that must be taken if the time, effort, and cost of processing standards is to be minimized. This method of radiometric drift correction uses a 1,000-W tungsten-halogen reference lamp to illuminate each detector through the same optical path as that traversed during sample analysis. The responses of the detector channels to this reference light are regularly compared with channel response to the same light intensity at the time of analytical calibration in order to determine and correct for drift. Except for placing the lamp in position, the procedure is fully automated and compensates for changes in spectral intensity due to variations in lamp current. A discussion of the implementation of this drift-correction system is included.

Chapman, G. B., II↗

Orthorectified High Resolution Multispectral Imagery for Application to Change Detection and Analysis

The project team has outlined several technical objectives which will allow the companies to improve on their current capabilities. These include modifications to the imaging system, enabling it to operate more cost effectively and with greater ease of use, automation of the post-processing software to mosaic and orthorectify the image scenes collected, and the addition of radiometric calibration to greatly aid in the ability to perform accurate change detection. Business objectives include fine tuning of the market plan plus specification of future product requirements, expansion of sales activities (including identification of necessary additional resources required to meet stated revenue objectives), development of a product distribution plan, and implementation of a world wide sales effort.

Benkelman, Cody A.↗