Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Neutronics Analysis of Heating and DPA of the Proton Beam Window and Core Vessel Nozzle Neutronics Heating Analysis for the Second Target Station

This reports details the analysis of the heating rates, dpa values and He production in the Proton Beam Window (PBW) assembly and the Core Vessel (CV) nozzle for the preliminary design for the Second Target Station (STS). This analysis focuses on the heating rates in the cooled beltline component of the CV. Neutronics calculations use a detailed unstructured mesh (UM) converted from a CAD model in SpaceClaim of the PBW and CV design of February 2024. The rest of the geometry is taken from the STS master model in constructive solid geometry (CSG). Heating is evaluated for four beam profiles, which are chosen as the most likely to produce the highest heating in the beltline component. The maximum energy deposition values in the beltline are 0.02-0.08 J/cc/pulse, depending on the beam profile. Detailed point cloud data of the full UM geometry is made available for mechanical analysis. The maximum dpa rate in the beltline steel is approximately 0.02 dpa/year, which corresponds to a lifetime of 3,000 years. These results are in good agreement with previous results for the CV. For the PBW itself, maximal heating, dpa, and He production rates are very similar to the previous analysis.

43 PARTICLE ACCELERATORS↗

Pre-commissioning of the wide-dynamic range halo monitor to be installed in the Fermilab MI-8 line

The beam halo can contribute to beam losses in accelerators and is very difficult to measure. With an increase in beam intensity following the PIP-II upgrade at Fermilab, the beam losses are expected to be higher with some coming from beam halo. Therefore, it is important to measure the sources of beam halo to minimize the beam losses. A modified Halo Monitor developed by J-PARC will be installed in Fermilab MI-8 transfer line to measure the beam halo. In this paper, an update on the beam profile monitor fabrication is covered. The updates include the location selection for the Halo Monitor in the MI-8 transfer line, shielding options for instrumentation, initial testing of equipment, and ray tracing simulations for the Offner optics and the targets used in the monitor.

Babacan, Betiay [IIT, Chicago; Fermilab]↗

Coupled beam-target-moderator optimization for the Second Target Station

To support the design of the Second Target Station, that aims to provide the world’s highest peak brightness of cold neutrons, studies that optimize the dimensions of the target and moderators are invaluable. In this work, we investigate the influence of the target dimensions and beam profile on the performance and optimal size of the moderators. We perform optimization runs with detailed MCNP6.2 simulations using high-fidelity unstructured mesh geometries generated from parametrized CAD models. We demonstrate that small changes in target height do not influence the moderator performance if the beam dimensions are chosen adequately. We quantify the effect of beam footprint and target width on the moderator performance and show that the optimal moderator dimensions are insensitive to limited changes in target and beam profile.

Dakota↗

Exploring the Focusing Mechanism of the NuMI Horn Magnets

Neutrinos at the Main Injector (NuMI) is a project at Fermilab that provides an intense beam of neutrinos used by a number of experiments. NuMI creates a beam of pions that decay into neutrinos, muons, and other particles. Muons are registered by the muon monitors. Magnetic horns are the key elements of the NuMI beam line. This paper uses the muon beam profile observed at the muon monitors to study the NuMI horn focusing mechanism. It is found that the horn magnet generates dipole and quadrupole fields to focus pions. This suggests that the optics of the horn magnet are predominantly linear. Our study shows that the muon beam profile accurately detects the horn current within 0.05%.

43 PARTICLE ACCELERATORS↗

Unabsorbed light beamlets for diagnosing cross-beam energy transfer

Here, a new diagnostic has been fielded on OMEGA to diagnose cross-beam energy transfer (CBET) during direct-drive implosions. Unabsorbed light from each OMEGA laser beam is imaged as a distinct “spot” onto a gated optical imager. Each spot is in essence the end point of a beamlet of light that originates from different regions of each beam profile and follows a path determined by refraction. The intensity of light in the beamlet varies along its path as a result of absorption and CBET with other beamlets. This diagnostic allows the investigation of the effects of CBET on laser energy from specific locations of the beam profile. The diagnostic records images in two 200-ps time windows and includes a Wollaston prism to split each beamlet into two orthogonal polarizations recorded on separate images, allowing the absolute polarization of each beamlet to be determined. This diagnostic has provided the first evidence of polarization rotation caused by CBET during direct-drive implosions.

47 OTHER INSTRUMENTATION↗

A convolution model for obtaining the response of an ionization chamber in static non standard fields

Purpose: This work contains an alternative methodology for obtaining correction factors for ionization chamber (IC) dosimetry of small fields and composite fields such as IMRT. The method is based on the convolution/superposition (C/S) of an IC response function (RF) with the dose distribution in a certain plane which includes chamber position. This method is an alternative to the full Monte Carlo (MC) approach that has been used previously by many authors for the same objective. Methods: The readout of an IC at a point inside a phantom irradiated by a certain beam can be obtained as the convolution of the dose spatial distribution caused by the beam and the IC two-dimensional RF. The proposed methodology has been applied successfully to predict the response of a PTW 30013 IC when measuring different nonreference fields, namely: output factors of 6 MV small fields, beam profiles of cobalt 60 narrow fields and 6 MV radiosurgery segments. The two-dimensional RF of a PTW 30013 IC was obtained by MC simulation of the absorbed dose to cavity air when the IC was scanned by a 0.6 x 0.6 mm{sup 2} cross section parallel pencil beam at low depth in a water phantom. For each of the cases studied, the results of the IC direct measurement were compared with the corresponding obtained by the C/S method. Results: For all of the cases studied, the agreement between the IC direct measurement and the IC calculated response was excellent (better than 1.5%). Conclusions: This method could be implemented in TPS in order to calculate dosimetry correction factors when an experimental IMRT treatment verification with in-phantom ionization chamber is performed. The miss-response of the IC due to the nonreference conditions could be quickly corrected by this method rather than employing MC derived correction factors. This method can be considered as an alternative to the plan-class associated correction factors proposed recently as part of an IAEA work group on nonstandard field dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of a charge-state analyzer for electron cyclotron resonance ion source beams

A detailed experimental and simulation study of the extraction of a 24 keV He{sup +} beam from an ECR ion source and the subsequent beam transport through an analyzing magnet is presented. We find that such a slow ion beam is very sensitive to space-charge forces, but also that the neutralization of the beam's space charge by secondary electrons is virtually complete for beam currents up to at least 0.5 mA. The beam emittance directly behind the extraction system is 65 {pi} mm mrad and is determined by the fact that the ion beam is extracted in the strong magnetic fringe field of the ion source. The relatively large emittance of the beam and its non-paraxiality lead, in combination with a relatively small magnet gap, to significant beam losses and a five-fold increase of the effective beam emittance during its transport through the analyzing magnet. The calculated beam profile and phase-space distributions in the image plane of the analyzing magnet agree well with measurements. The kinematic and magnet aberrations have been studied using the calculated second-order transfer map of the analyzing magnet, with which we can reproduce the phase-space distributions of the ion beam behind the analyzing magnet. Using the transfer map and trajectory calculations we have worked out an aberration compensation scheme based on the addition of compensating hexapole components to the main dipole field by modifying the shape of the poles. The simulations predict that by compensating the kinematic and geometric aberrations in this way and enlarging the pole gap the overall beam transport efficiency can be increased from 16% to 45%.

43 PARTICLE ACCELERATORS↗

Development of a high-brightness and low-divergence lithium neutral beam for a Zeeman polarimetry on JT-60U

A high-brightness and low-divergence neutral beam is obtained for a Zeeman polarimetry of edge plasmas on JT-60U. The electron density and the pitch angle of the magnetic field line, thus the plasma current density distribution, can be measured by the Zeeman polarimetry using the lithium beam. A thermionic ion source heated by an electron beam is developed in order to obtain the ion beam current extraction over 10 mA. The beam optics is designed after detailed numerical simulation taking the space charge effects into account because a low-divergence angle of the neutral lithium beam leads to a narrow spectrum of the beam emission. It is also necessary to keep the beam radius small for good spatial resolution due to a long beam line of 6.5 m. The newly developed ion gun is operated on a test stand which simulates the diagnostic arrangement on JT-60U. The ion beam current of 10 mA at a beam energy of 10 keV is successfully extracted from the ion source operated at the temperature over 1300 deg. C and focused by Einzel lens. The full width at half maximum radius of the ion beam at the neutralizer is about 9 mm. A sodium vapor neutralizer neutralizes the collimated ion beam fully at the temperature of 300 deg. C. The neutral beam profiles are measured at two locations of the beam line at Z=2.3 m (beam monitor position) and Z=6.5 m (plasma region). The half-width at half maximum radius of the neutral beam of 26 mm and the equivalent beam current of 3 mA with the beam divergence angle of 0.2 deg. which is the half-angle divergence are obtained. Those parameters satisfy the requirements of the Zeeman polarimetry. Furthermore, a long pulse extraction with a current of 10 mA and duration of 50 s is attained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of intense permanent magnet proton source for China-accelerator driven sub-critical system Linac

Two compact intense 2.45 GHz permanent magnet proton sources and their corresponding low energy beam transport (LEBT) system were developed successfully for China accelerator driven sub-critical system in 2014. Both the proton sources operate at 35 kV potential. The beams extracted from the ion source are transported by the LEBT, which is composed of two identical solenoids, to the 2.1 MeV Radio-Frequency Quadrupole (RFQ). In order to ensure the safety of the superconducting cavities during commissioning, an electrostatic-chopper has been designed and installed in the LEBT line that can chop the continuous wave beam into a pulsed one. The minimum width of the pulse is less than 10 μs and the fall/rise time of the chopper is about 20 ns. The performance of the proton source and the LEBT, such as beam current, beam profile, emittance and the impact to RFQ injection will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of ion beam extraction and transport from an electron cyclotron resonance ion source

We have started an experimental and theoretical program to better understand the extraction and transport of intense multiply charged ion beams from an electron cyclotron resonance ion source (ECRIS). In this paper we present the first results of this program concerning a simple, monocomponent He{sup +} beam extracted from an ECRIS. We have calculated the ion trajectories starting from the ECRIS plasma electrode up to the image plane of the analyzing magnet taking into account space-charge effects and fringe fields. The initial phase-space distribution of the He{sup +} beam at the extraction aperture has been calculated with a particle-in-cell code. To check the simulations we have measured beam profiles with a viewing screen both before and after the analyzing magnet. In addition also measurements with a pepperpot emittance meter located behind the analyzing magnet have been performed. We find good agreement between these measurements and simulations showing that (i) there is a significant compensation of the space charge and that (ii) our analyzing magnet causes a severe increase in effective beam emittance.

43 PARTICLE ACCELERATORS↗

SEN Ultra-High Energy Implanter (UHE) Developed for Next Generation Image Sensors

The UHE is an ultra-high energy implanter developed by SEN Corporation. It was derived from the NV-GSD-HE3 by adding six RF resonators to the beam line. This extends performance so that singly charged boron ions can reach 2 MeV with beam current of 0.75 mA. The maximum energy for triple charged boron is 5 MeV with beam current of 1p{mu}A. For phosphorus ions, the UHE can accelerate doubly charged ions up to 4.4 MeV with beam current of 0.35 mA and quadruply charged ions up to 8 MeV with beam current of 1 p{mu}A. The primary application of the UHE is the image sensor market where it is used to increase the depth of CCD photodiodes into the surface of the wafer and thereby permit higher pixel density for image sensors. The second purpose is to improve productivity for relatively high boron doses at energies around 3 MeV. In order to address certain CCD defects, the system includes a state-of-the-art beam profile controller which allows optimization of implant damage and micro-uniformity. The ULE is currently used in production of high-end CCD's.

43 PARTICLE ACCELERATORS↗

High-power terahertz quantum cascade lasers with ∼0.23 W in continuous wave mode

Terahertz quantum cascade lasers with a record output power up to ∼0.23 W in continuous wave mode were obtained. We show that the optimal 2.9-mm-long device operating at 3.11 THz has a low threshold current density of 270 A/cm{sup 2} at ∼15 K. The maximum operating temperature arrived at ∼65 K in continuous wave mode and the internal quantum efficiencies decreased from 0.53 to 0.19 for the devices with different cavity lengths. By using one convex lens with the effective focal length of 13 mm, the beam profile was collimated to be a quasi Gaussian distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tailored Particle Beams From Single-Component Plasmas

Recently, we developed a non-destructive technique to create narrow beams of electrons (or positrons) of adjustable width and brightness from single-component plasmas confined in a Penning-Malmberg trap [Weber et al., Phys. Plasmas 13, 123502 (2008)]. Here, we review highlights of that work and discuss the distributions in energy of the extracted beams. A simple model for beam extraction predicts Gaussian beam profiles, with transverse spatial widths dependent on the number of particles in the beam. A Maxwellian energy distribution is predicted for small beams. The predictions of the theory are confirmed using electron plasmas. Extraction of over 50% of a trapped plasma into a train of nearly identical beams is demonstrated. Finally, the possibility of creating high quality, electrostatic beams by extraction from the confining magnetic field is discussed.

43 PARTICLE ACCELERATORS↗

Geometrical splitting technique to improve the computational efficiency in Monte Carlo calculations for proton therapy

Purpose: To present the implementation and validation of a geometrical based variance reduction technique for the calculation of phase space data for proton therapy dose calculation. Methods: The treatment heads at the Francis H Burr Proton Therapy Center were modeled with a new Monte Carlo tool (TOPAS based on Geant4). For variance reduction purposes, two particle-splitting planes were implemented. First, the particles were split upstream of the second scatterer or at the second ionization chamber. Then, particles reaching another plane immediately upstream of the field specific aperture were split again. In each case, particles were split by a factor of 8. At the second ionization chamber and at the latter plane, the cylindrical symmetry of the proton beam was exploited to position the split particles at randomly spaced locations rotated around the beam axis. Phase space data in IAEA format were recorded at the treatment head exit and the computational efficiency was calculated. Depth-dose curves and beam profiles were analyzed. Dose distributions were compared for a voxelized water phantom for different treatment fields for both the reference and optimized simulations. In addition, dose in two patients was simulated with and without particle splitting to compare the efficiency and accuracy of the technique. Results: A normalized computational efficiency gain of a factor of 10-20.3 was reached for phase space calculations for the different treatment head options simulated. Depth-dose curves and beam profiles were in reasonable agreement with the simulation done without splitting: within 1% for depth-dose with an average difference of (0.2 {+-} 0.4)%, 1 standard deviation, and a 0.3% statistical uncertainty of the simulations in the high dose region; 1.6% for planar fluence with an average difference of (0.4 {+-} 0.5)% and a statistical uncertainty of 0.3% in the high fluence region. The percentage differences between dose distributions in water for simulations done with and without particle splitting were within the accepted clinical tolerance of 2%, with a 0.4% statistical uncertainty. For the two patient geometries considered, head and prostate, the efficiency gain was 20.9 and 14.7, respectively, with the percentages of voxels with gamma indices lower than unity 98.9% and 99.7%, respectively, using 2% and 2 mm criteria. Conclusions: The authors have implemented an efficient variance reduction technique with significant speed improvements for proton Monte Carlo simulations. The method can be transferred to other codes and other treatment heads.

60 APPLIED LIFE SCIENCES↗

Implementation and commissioning of an integrated micro-CT/RT system with computerized independent jaw collimation

Purpose: To design, construct, and commission a set of computer-controlled motorized jaws for a micro-CT/RT system to perform conformal image-guided small animal radiotherapy.Methods: The authors designed and evaluated a system of custom-built motorized orthogonal jaws, which allows the delivery of off-axis rectangular fields on a GE eXplore CT 120 preclinical imaging system. The jaws in the x direction are independently driven, while the y-direction jaws are symmetric. All motors have backup encoders, verifying jaw positions. Mechanical performance of the jaws was characterized. Square beam profiles ranging from 2 × 2 to 60 × 60 mm{sup 2} were measured using EBT2 film in the center of a 70 × 70 × 22 mm{sup 3} solid water block. Similarly, absolute depth dose was measured in a solid water and EBT2 film stack 50 × 50 × 50 mm{sup 3}. A calibrated Farmer ion chamber in a 70 × 70 × 20 mm{sup 3} solid water block was used to measure the output of three field sizes: 50 × 50, 40 × 40, and 30 × 30 mm{sup 2}. Elliptical target plans were delivered to films to assess overall system performance. Respiratory-gated treatment was implemented on the system and initially proved using a simple sinusoidal motion phantom. All films were scanned on a flatbed scanner (Epson 1000XL) and converted to dose using a fitted calibration curve. A Monte Carlo beam model of the micro-CT with the jaws has been created using BEAMnrc for comparison with the measurements. An example image-guided partial lung irradiation in a rat is demonstrated.Results: The averaged random error of positioning each jaw is less than 0.1 mm. Relative output factors measured with the ion chamber agree with Monte Carlo simulations within 2%. Beam profiles and absolute depth dose curves measured from the films agree with simulations within measurement uncertainty. Respiratory-gated treatments applied to a phantom moving with a peak-to-peak amplitude of 5 mm showed improved beam penumbra (80%–20%) from 3.9 to 0.8 mm.Conclusions: A set of computer-controlled motorized jaws for a micro-CT/RT system were constructed with position reliably better than a tenth of a millimeter. The hardware system is ready for image-guided conformal radiotherapy for small animals with capability of respiratory-gated delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bunch characteristics of an electron beam generated by a diamond secondary emitter amplifier

Electron bunches for high performance free electron lasers are subject to constraints on charge per bunch and pulse shape. A Diamond secondary emitter used in conjunction with a photocathode and drive laser has potential to enable a high brightness, high peak current photoinjector by increasing the effective quantum efficiency of the photocathode. A theoretical characterization of the bunches so produced has been heretofore absent. Using a combination of Monte Carlo and analytical models, the shape of the bunches, their transit time, and emission time constants are determined and shown to be sensitive to the accelerating field in the diamond flake, incident beam profile, doping, and surface conditions. Methods to allow for extension to regimes of technological interest in terms of diamond thickness, external field, and primary pulse shape are given.

07 ISOTOPE AND RADIATION SOURCES↗

Fabrication of optical multilayer for two-color phase plate in super-resolution microscope

In super-resolution microscopy based on fluorescence depletion, the two-color phase plate (TPP) is an indispensable optical element, which can independently control the phase shifts for two beams of different color, i.e., the pump and erase beams. By controlling a phase shift of the erase beam through the TPP, the erase beam can be modulated into a doughnut shape, while the pump beam maintains the initial Gaussian shape. To obtain a reliable optical multiplayer (ML) for the TPP, we designed a ML with only two optical layers by performing numerical optimization. The measured phase shifts generated by the fabricated ML using interferometry correspond to the design values. The beam profiles in the focal plane are also consistent with theoretical results. Although the fabricated ML consists of only two optical layers, the ML can provide a suitable phase modulation function for the TPP in a practical super-resolution microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prediction of laser beam spatial profiles in a high-energy laser facility by use of deep learning

We adapt the significant advances achieved recently in the field of generative artificial intelligence/machine-learning to laser performance modeling in multipass, high-energy laser systems with application to high-shot-rate facilities relevant to inertial fusion energy. Advantages of neural-network architectures include rapid prediction capability, data-driven processing, and the possibility to implement such architectures within future low-latency, low-power consumption photonic networks. Four models were investigated that differed in their generator loss functions and utilized the U-Net encoder/decoder architecture with either a reconstruction loss alone or combined with an adversarial network loss. We achieved inference times of 1.3 ms for a 256 × 256 pixel near-field beam with errors in predicted energy of the order of 1% over most of the energy range. It is shown that prediction errors are significantly reduced by ensemble averaging the models with different weight initializations. These results suggest that including the temporal dimension in such models may provide accurate, real-time spatiotemporal predictions of laser performance in high-shot-rate laser systems.

47 OTHER INSTRUMENTATION↗