Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Simulation of a scintillator-based fast ion loss detector for steady-state operation in Wendelstein 7-X (invited)

A quantitative theoretical framework has been created to model neutral beam injection and fast ion losses in the Wendelstein 7-X (W7-X) stellarator, including a novel method to develop synthetic diagnostics for fast ion loss detectors (FILDs) of many types, such as scintillating and Faraday Cup FILDs. This is the first time that this has been done in stellarator geometry with this level of fidelity, providing a way for fast ion losses to be predicted more precisely in future stellarator experiments and in W7-X. Simulations of the signal seen by a Faraday Cup FILD have been completed for multiple W7-X plasmas and show close agreement with the measured signals. This method is now applied to an actively water-cooled, scintillator-based FILD, which is currently in development to measure the fast ion loss distribution in W7-X in greater detail. The design makes use of a double slit to measure energy-and-pitch-angle-resolved losses of both co-going and counter-going fast ions. The diagnostic, which can be inserted to different radial positions, has been designed to withstand steady-state heat fluxes of up to 120 kW/m 2 along with additional transient heat loads of 100 kW/m 2 lasting for up to 20 s at a time. Simulations of W7-X standard magnetic configuration show up to 8 × 10 13 (s –1 cm –2 ) ion fluxes onto the sensor from each neutral beam source and no signal from the counter-going slit. Finally, these simulations will help inform experimental proposals for future W7-X campaigns after installation of this diagnostic.

3D printing↗

Fingerprinting Uranium Oxides with Electron Energy Loss Spectroscopy Supported by Theoretical Computations

Uranium oxides occur in a variety of phases that differ in crystal structure and uranium oxidation states. Electron energy loss spectroscopy (EELS) is one of the few techniques that has sufficient spatial resolution and sensitivity to electronic structure to distinguish amongst phases at the nanoscale. However, beam-sensitive materials such as uranium oxides are subject to spectral modification due to interactions with the electron beam. Therefore, theory support is essential to reliably exclude the impact of beam damage and generate true reference datasets. Here we use a comparison of theoretical and experimental spectra to probe the impact of beam damage on O K-edge and U N-edge (N6,7 and N4,5) EELS spectra of various single-valent and mixed-valence uranium oxide bulk phases. Using a low-dose experimental set-up, we show that the O K-edge theoretical spectra are in excellent agreement with experiment for both peak positions and relative intensities of respective peaks. In contrast, U N-edge features are less distinguishing due to the partially localized nature of the U 5f orbitals and overlapping multiplet and spin–orbit coupling effects. This work demonstrates that O K-edge EELS is sufficiently diagnostic to distinguish a wide range of uranium oxides and that the experimental approach used here minimizes beam damage and allows valence state discrimination across the U(IV), U(V) and U(VI) series. When combined with imaging modes available in electron mi-croscopy, the work enables detailed investigation and characterization of uranium redox transformations at the nanoscale.

Carbone, Jacopo↗

Microwave diagnostic for the determination of the electron temperature of a low density shock-heated argon plasma

The diffraction, defocusing and beam bending effects of microwaves transmitted through a bounded shock-heated argon plasma with low electron density are investigated with the purpose of developing an accurate method for electron temperature (Te) determination. This report describes the evaluation technique and presents results for an argon plasma with pressure between 3 and 10 torr, and T2 between 5500 and 9500 K. The electron temperature values obtained have a range of uncertainty between -20% and +10% only. The electron temperature is equal or lower by approximately 1000 K in comparison to the heavy particle temperature (T2).

Schneider, C. P.↗

Collisional quenching of atoms and molecules on spacecraft thermal protection surfaces

Preliminary results of a research program to determine energy partitioning in spacecraft thermal protection materials due to atom recombination at the gas-surface interface are presented. The primary focus of the research is to understand the catalytic processes which determine heat loading on Shuttle, Aeroassisted OTV, and NASP thermal protection surfaces in nonequilibrium flight regimes. Highly sensitive laser diagnostics based on laser-induced fluorescence and resonantly-enhanced multiphoton ionization spectroscopy are used to detect atoms and metastable molecules. At low temperatures, a discharge flow reactor is employed to measure deactivation/recombination coefficients for O-atoms, N-atoms, and O2. Detection methods are presented for measuring O-atoms, O2 and N2, and results for deactivation of O2 and O-atoms on reaction-cured glass and Ni surfaces. Both atom recombination and metastable product formation are examined. Radio-frequency discharges are used to produce highly dissociated beams of atomic species at energies characteristic of the surface temperature. Auger electron spectroscopy is employed as a diagnostic of surface composition in order to accurately define and control measurement conditions.

Marinelli, W. J.↗

A pulsed electron-photon fluorescence diagnostic technique for temperature and specie concentration measurement at points in relatively dense, unseedded air flows

An analysis is presented on the use of the fluorescence stimulated by combined pulsed electron and photon beams for the study of gas flows up to densities equivalent to an altitude of about 20 km (number density of about 3 x 10 to the 18th/cu cm). The electron beam acts as a pump, requiring no seed gas, to provide a localized concentration of ions or excited state neutrals that can be probed by saturation optical pulses. A short pulse (10ns) electron beam can be used by itself to provide effectively quench-free emission up to number densities of around 10 to the 18th/cm, but is is difficult to maintain satisfactory spatial resolution at this high density. The use of a nearly simultaneous strong optical pulse increases the flexibility of the diagnostic technique, permitting use at densities greater than 10 to the 18th/cu cm with good spatial resolution. The use of flash X-ray sources combined with optical probing also appears promising for densities above 10 to the 19th/cu cm.

Muntz, E. P.↗

Pulsed-electron-beam annealing of ion-implantation damage

Short-duration high-intensity pulsed electron beams have been used to anneal ion-implantation damage in silicon and to electrically activate the dopant species. Lattice regrowth and dopant activation were determined using He(+)-4 backscattering, SEM, TEM, and device performance characteristics as diagnostic techniques. The annealing mechanism is believed to be liquid-phase epitaxial regrowth initiating from the substrate. The high-temperature transient pulse produced by the electron beam causes the dopant to diffuse rapidly in the region where the liquid state is achieved.

Greenwald, A. C.↗

Runaway electron-induced plasma facing component damagein tokamaks

This Roadmap article addresses the critical and multifaceted challenge of plasma facing component (PFC) damage caused by runaway electrons (REs) in tokamaks, a phenomenon that poses a significant threat to the viability and longevity of future fusion reactors such as ITER and DEMO. The dramatically increased RE production expected in future high-current tokamaks makes it very difficult to avoid or mitigate REs in such devices when a plasma discharge terminates abnormally. Preventing damage from the intense localised heat loads they can cause requires a holistic approach that considers plasma, REs and PFC damage. Despite decades of progress in understanding the physics of REs and the thermomechanical response of PFCs separately, their complex interplay remains poorly understood. This document aims to initiate a coordinated, interdisciplinary approach to bridge this gap by reviewing experimental evidence, advancing diagnostic capabilities, and improving modelling tools across different scales, dimensionalities, and fidelities. Key topics include RE beam formation and transport, damage mechanisms in both brittle and metallic PFCs, and observed effects in major facilities such as JET, DIII-D, WEST and EAST. The Roadmap emphasises the urgency of predictive, high-fidelity modelling validated against well-diagnosed controlled experiments, particularly in the light of recent changes in ITER’s wall material strategy and the growing importance of private sector fusion initiatives. Each section of the Roadmap article is written to provide a concise overview of one area of this multidisciplinary subject, with an assessment of the status, a look at current and future challenges, and a brief summary. The ultimate goal of this initiative is to guide future mitigation strategies and design resilient components that can withstand the intense localised loads imposed by REs, thus ensuring the safe and sustainable operation of the next generation of fusion power plants.

Ratynskaia, Svetlana [KTH Royal Inst. of Technolog↗

SUMMA hot-ion plasma heating research at NASA Lewis Research Center

The SUMMA superconducting magnetic mirror facility and the associated hot-ion plasma research were described. SUMMA is characterized by intense magnetic fields and a large-diameter working bore (41 cm diameter) with room-temperature access. The goal of the plasma research program is to produce steady-state plasmas of fusion reactor densities and temperatures (but not confinement times). The program includes electrode development to produce a hot, dense, large-volume, steady-state plasma and diagnostics development to document the plasma properties. SUMMA and its hot-ion plasma are ideally suited to develop advanced plasma diagnostics methods. Two such methods whose requirements are well matched to SUMMA are: (1) heavy ion beam probing to measure plasma space potential; and (2) submillimeter wavelength laser Thomson scattering to measure local ion temperature.

Reinmann, J. J.↗

Park Smart

The Parking Garage Automation System (PGAS) is based on a technology developed by a NASA-sponsored project called Robot sensorSkin(TM). Merritt Systems, Inc., of Orlando, Florida, teamed up with NASA to improve robots working with critical flight hardware at Kennedy Space Center in Florida. The system, containing smart sensor modules and flexible printed circuit board skin, help robots to steer clear of obstacles using a proximity sensing system. Advancements in the sensor designs are being applied to various commercial applications, including the PGAS. The system includes a smartSensor(TM) network installed around and within public parking garages to autonomously guide motorists to open facilities, and once within, to free parking spaces. The sensors use non-invasive reflective-ultrasonic technology for high accuracy, high reliability, and low maintenance. The system is remotely programmable: it can be tuned to site-specific requirements, has variable range capability, and allows remote configuration, monitoring, and diagnostics. The sensors are immune to interference from metallic construction materials, such as rebar and steel beams. Inside the garage, smart routing signs mounted overhead or on poles in front of each row of parking spots guide the motorist precisely to free spaces.

Source record↗

Low Speed Azimuthal Wave Characteristics In a Cathode Plume

A diagnostic technique to measure the azimuthally traveling m=1 mode in the plume of a cathode inside a HET-like magnetic field was developed. The data show the wave accelerating with the increasing magnetic field strength. While the azimuthal wave grows, the presence of a high frequency (>1MHz) instability appears. While the appearance of this wave and general characteristics were observed using this diagnostic technique, further full-thruster environment testing is needed to show the effects the HET beam has on these instabilities

space propulsion↗

New Insights into the X-Ray Spectra of Heliumlike and Neonlike Ions

Recent measurements of the K-shell and L-shell x-ray spectra of highly charged helium- like and neonlike ions are presented that were performed on the Livermore electron beam ion traps and the Princeton tokamaks. These measurements provide new insights into collisional and indirect line formation processes, identifications of forbidden lines, and a new plasma line diagnostic of magnetic field strength.

IONS↗

Ion Beam Characterization of a NEXT Multi-Thruster Array Plume

Three operational, engineering model, 7-kW ion thrusters and one instrumented, dormant thruster were installed in a cluster array in a large vacuum facility at NASA Glenn Research Center. A series of engineering demonstration tests were performed to evaluate the system performance impacts of operating various multiple-thruster configurations in an array. A suite of diagnostics was installed to investigate multiple-thruster operation impact on thruster performance and life, thermal interactions, and alternative system modes and architectures. The ion beam characterization included measuring ion current density profiles and ion energy distribution with Faraday probes and retarding potential analyzers, respectively. This report focuses on the ion beam characterization during single thruster operation, multiple thruster operation, various neutralizer configurations, and thruster gimbal articulation. Comparison of beam profiles collected during single and multiple thruster operation demonstrated the utility of superimposing single engine beam profiles to predict multi-thruster beam profiles. High energy ions were detected in the region 45 off the thruster axis, independent of thruster power, number of operating thrusters, and facility background pressure, which indicated that the most probable ion energy was not effected by multiple-thruster operation. There were no significant changes to the beam profiles collected during alternate thruster-neutralizer configurations, therefore supporting the viability of alternative system configuration options. Articulation of one thruster shifted its beam profile, whereas the beam profile of a stationary thruster nearby did not change, indicating there were no beam interactions which was consistent with the behavior of a collisionless beam expansion.

Pencil, Eric J.↗

An experimental study of laser supported hydrogen plasmas

The rudiments of a rocket thruster which receives its enthalpy from an energy source which is remotely beamed from a laser is described. An experimental study now partially complete is discussed which will eventually provide a detailed understanding of the physics for assessing the feasibility of using hydrogen plasmas for accepting and converting this energy to enthalpy. A plasma ignition scheme which uses a pulsed CO2 laser has been developed and the properties of the ignition spark documented, including breakdown intensities in hydrogen. A complete diagnostic system capable of determining plasma temperature and the plasma absorptivity for subsequent steady state absorption of a high power CO2 laser beam are developed and demonstrative use is discussed for the preliminary case study, a two atmosphere laser supported argon plasma.

Vanzandt, D. M.↗

Design of Ionization Profile Monitors at the Integrable Optics Test Accelerator Facility at Fermilab

The Integrable Optics Test Accelerator (IOTA) at Fermilab is transitioning from an electron beam facility to a proton beam facility for studies in nonlinear accelerator optics and space-charge dominated proton beams. This project involves the commissioning and fabrication of Ionization Profile Monitors (IPMs) to enable beam profile measurements at IOTA. In general, IPMs work on principle of residual gas ionization by the beam to generate beam profile. This work focuses on a mechanical design that leverages a controlled injection of noble gases, primarily Argon, as the ultra-high vacuum of the IOTA ring provides insufficient residual gas for ionization. Efforts to understand vacuum integration to ensure compatibility with the storage ring environment, the integration of real-time data acquisition systems and the commissioning of the IPMs will be discussed. This project provides a versatile diagnostic tool, supporting IOTA’s role as a testbed for larger-scale accelerator facilities and contributing to the broader understanding of beam physics in high-intensity, high-space-charge regimes.

Mwaniki, M. W. [IIT, Chicago] (ORCID:0000000169057↗

Coded-mask-based wavefront sensing technique for APS nanofocusing beamline diagnostics

Here, we extend our recently developed coded-mask wavefront sensing technique to enable single-shot measurements of nanofocused x-ray beams. This method accurately reconstructs the focal beam profile by backpropagating the wavefront measured downstream of the beam focus. To validate its performance, we benchmarked it against the conventional fluorescence wire scan method, successfully measuring ∼120 nm focal spots at the 28-ID-B beamline of the Advanced Photon Source using a polymeric compound refractive lens. The results highlight the effectiveness of coded-mask wavefront sensing for high-precision beam profiling and its application as a real-time wavefront monitoring tool.

Shi, Xianbo [Argonne National Laboratory (ANL), Ar↗

A method for modeling discontinuities in a microwave coaxial transmission line

A method for modeling discontinuities in a coaxial transmission line is presented. The methodology involves the use of a nonlinear least-squares fit program to optimize the fit between theoretical data (from the model) and experimental data. When this method was applied to modeling discontinuities in a slightly damaged Galileo spacecraft S-band (2.295-GHz) antenna cable, excellent agreement between theory and experiment was obtained over a frequency range of 1.70-2.85 GHz. The same technique can be applied for diagnostics and locating unknown discontinuities in other types of microwave transmission lines, such as rectangular, circular, and beam waveguides.

Otoshi, T. Y.↗