At least 271 records · Page 15

U-10Mo Conversion Burnup Benchmarking Activities for Full-Size LEU Fuel Plates

Validation benchmark experiments for low-enriched uranium (LEU) U-Mo fuel systems are currently being developed from existing experiments irradiated in the Advanced Test Reactor. (ATR) and ATR Critical Facility (ATRC). The experiments chosen include the ATR Full size plate In center Flux trap Position (AFIP-7) experiment and the Ki-Jang Research Reactor Lead Test Assembly (KJRR-LTA) located in the Northeast Flux Trap. Each experiment was modeled using a high-fidelity three-dimensional Monte Carlo code with depletion capabilities. A description of the validation experiments will be provided as well as comparison to post irradiation examination results for the AFIP-7 experiment. The PIE results for the AFIP-7 experiment have demonstrated good agreement with analytical models. Due to the complex nature in of the ATR, modeling simplifications to support benchmark activities using lower fidelity reactor physics software. A discussion of the analytical bias associated with modeling simplifications will also be provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

THE INFLUENCE OF CHANGES IN NUCLEAR COVARIANCE DATA ON THE CALCULATION OF Ck FOR HIGHLY ENRICHED URANIUM SOLUTION SYSTEMS

Since their initial development nearly 20 years ago, sensitivity/uncertainty (S/U) techniques have been increasingly applied to criticality safety validation. These techniques can generally be applied quickly and for a range of purposes after the initial investment of calculating sensitivities for a safety analysis model and a range of potential benchmark experiments. This paper discusses these applications and how they have been affected by changes in covariance data libraries.Critical experiment selection is the most prominent area in which S/U methods impact validation efforts. These methods allow for rigorous calculation of similarity between safety analysis models and potential benchmarks. The most widely used of these methods is the integral parameter ck, although other integral parameters such as E and some non-integral parameters have also been explored. The ck parameter calculates the fraction of nuclear data–induced uncertainty shared between an application and an experiment; this metric is predicated on the assessment that nuclear data errors are the most likely source of computational bias. Therefore, values of ck are inherently dependent on the nuclear covariance library used to calculate them and inevitably change when these data change.Past studies have shown how much the ck values can vary, especially in difficult validation cases like burnup credit. These significant changes are the result of differences in the relative uncertainties of nuclides with large sensitivities, and they imply differences in benchmark applicability to the safety analysis model. This paper demonstrates that more common criticality safety models involving single fissile species have significantly less variability of ck between covariance libraries, thus enhancing confidence in the application of S/U methods for experiment selection in these scenarios. This paper presents case studies examining the impact of these changes on some hypothetical safety analysis systems.

Clarity, Justin↗

TRIPOLI-4 criticality calculations for MOX fuelled SNEAK 7A and 7B fast critical assemblies

A prototype Generation IV fast neutron reactor is under design and development in France. The MOX fuel will be introduced into this self-generating core in order to demonstrate low net plutonium production. To support the TRIPOLI-4 Monte Carlo transport code in criticality calculations of fast reactors, the effective delayed neutron fraction {beta}eff estimation and the Probability Tables (PT) option to treat the unresolved resonance region of cross-sections are two essentials. In this study, TRIPOLI-4 calculations have been made using current nuclear data libraries JEFF-3.1.1 and ENDF/B-VII.0 to benchmark the reactor physics parameters of the MOX fuelled SNEAK 7A and 7B fast critical assemblies. TRIPOLI-4 calculated K{sub eff} and {beta}eff of the homogeneous R-Z models and the 3D multi-cell models have been validated against the measured ones. The impact of the PT option on K{sub eff} is 340 {+-} 10 pcm for SNEAK 7A core and 410 {+-} 12 pcm for 7B. Four-group spectra and energy spectral indices, f8/f5, f9/f5, and c8/f5 in the two SNEAK cores have also been calculated with the TRIPOLI-4 mesh tally. Calculated spectrum-hardening index f8/f5 is 0.0418 for SNEAK 7A and 0.0315 for 7B. From this study the SNEAK 3D models have been verified for the next revision of IRPhE (International Handbook of Evaluated Reactor Physics Benchmark Experiments). (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Uncertainties in Masses, Dimensions, Impurities, and Isotopics of HEU Metal Used in Critical Experiments at ORCEF

This report documents uncertainties in the mass, dimensions, impurities, and isotopics of the highly enriched uranium (HEU) metal (oralloy) used in a wide variety of delayed critical experiments at the Oak Ridge Critical Experiments Facility (ORCEF) in the late 1950s, 1960s, and 1970s. Most of these experiments were performed in the east cell of ORCEF. The accuracies of the masses were much less than 1 gram, the dimensions to 0.0004 in., and 0.0177 wt % uncertainty for the 235U isotopic content of HEU. The total 235U uncertainty for a 25,000 gram mass of oralloy (nominal 93.15 wt% 235U) is 0.054%, which corresponds to ~13 grams. This calculated uncertainty includes the uncertainties associated with impurity content, grams of uranium per grams of oralloy, and isotopic content. These data are of interest to the Working Party of Nuclear Criticality Safety (WPNCS) International Criticality Safety Benchmark Experiment Project (ICSBEP) because these HEU metal critical experiments at ORCEF have been or are being documented as benchmarks for nuclear criticality safety calculations for ICSBEP. This report is a collection of information from various sources, some of which are contained in previous reports and emails. These experiments may be the most accurately described critical experiments ever performed, mainly because of the combination of the Y-12 capabilities for accurately fabricating and defining the materials (mainly HEU metal, referred to as oralloy, an acronym for Oak Ridge alloy) and the care of the researchers in documenting the experiments.

Mihalczo, John T.↗

First Industrial Tests of a Drum Monitor Matrix Correction for the Fissile Mass Measurement in Large Volume Historic Metallic Residues with the Differential Die-away Technique

The fissile mass in radioactive waste drums filled with compacted metallic residues (spent fuel hulls and nozzles) produced at AREVA La Hague reprocessing plant is measured by neutron interrogation with the Differential Die-away measurement Technique (DDT. In the next years, old hulls and nozzles mixed with Ion-Exchange Resins will be measured. The ion-exchange resins increase neutron moderation in the matrix, compared to the waste measured in the current process. In this context, the Nuclear Measurement Laboratory (NML) of CEA Cadarache has studied a matrix effect correction method, based on a drum monitor ({sup 3}He proportional counter inside the measurement cavity). A previous study performed with the NML R and D measurement cell PROMETHEE 6 has shown the feasibility of method, and the capability of MCNP simulations to correctly reproduce experimental data and to assess the performances of the proposed correction. A next step of the study has focused on the performance assessment of the method on the industrial station using numerical simulation. A correlation between the prompt calibration coefficient of the {sup 239}Pu signal and the drum monitor signal was established using the MCNPX computer code and a fractional factorial experimental design composed of matrix parameters representative of the variation range of historical waste. Calculations have showed that the method allows the assay of the fissile mass with an uncertainty within a factor of 2, while the matrix effect without correction ranges on 2 decades. In this paper, we present and discuss the first experimental tests on the industrial ACC measurement system. A calculation vs. experiment benchmark has been achieved by performing dedicated calibration measurement with a representative drum and {sup 235}U samples. The preliminary comparison between calculation and experiment shows a satisfactory agreement for the drum monitor. The final objective of this work is to confirm the reliability of the modeling approach and the industrial feasibility of the method, which will be implemented on the industrial station for the measurement of historical wastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

First Industrial Tests of a Matrix Monitor Correction for the Differential Die-away Technique of Historical Waste Drums

The fissile mass in radioactive waste drums filled with compacted metallic residues (spent fuel hulls and nozzles) produced at AREVA NC La Hague reprocessing plant is measured by neutron interrogation with the Differential Die-away measurement Technique (DDT). In the next years, old hulls and nozzles mixed with Ion-Exchange Resins will be measured. The ion-exchange resins increase neutron moderation in the matrix, compared to the waste measured in the current process. In this context, the Nuclear Measurement Laboratory (LMN) of CEA Cadarache has studied a matrix effect correction method, based on a drum monitor, namely a 3He proportional counter located inside the measurement cavity. After feasibility studies performed with LMN's PROMETHEE 6 laboratory measurement cell and with MCNPX simulations, this paper presents first experimental tests performed on the industrial ACC (hulls and nozzles compaction facility) measurement system. A calculation vs. experiment benchmark has been carried out by performing dedicated calibration measurements with a representative drum and {sup 235}U samples. The comparison between calculation and experiment shows a satisfactory agreement for the drum monitor. The final objective of this work is to confirm the reliability of the modeling approach and the industrial feasibility of the method, which will be implemented on the industrial station for the measurement of historical wastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation of Jezebel Reactivity Coefficients and Sensitivity Analysis

Nuclear data validation is often performed today using criticality measurements. The gold standard for criticality measurements is the International Criticality Safety Benchmark Experiment Project (ICSBEP). The validation specifically focuses on the effective multiplication factor ($k_{eff}$). $K_{eff}$ is a relatively easy parameter to infer and has reduced uncertainty due to being at or above critical. However, while $k_{eff}$ is the most documented parameter and its uncertainties and sensitivities have been evaluated in great detail, it cannot be used as a standalone metric to determine inaccuracies in nuclear data (e.g., cross section data, PFNS, nu), which is based on theory, physics, and differential measurements. The Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) project aims to identify compensating errors in specific isotope nuclear data by optimally designing experiments that are, or are not sensitive to a suite of measurement parameters beyond $k_{eff}$. By identifying parameters that are sensitive to each other, oppositely sensitive, or have substantial magnitude differences in sensitivity, experiments can be designed to constrain questionable nuclear data. One sensitivity that is of particular interest to this project includes the sensitivity of reactivity coefficients. Reactivity coefficients compare reactivity, which is related to $k_{eff}$ at two different states therefore being sensitive to small changes in the system. The most common type of reactivity coefficient measurements is comparison to void for a small sample within the assembly. It is key that the sample sizes are small enough to not affect the flux of the full system. Reactivity coefficients were evaluated for many early experiments to better understand transport corrected cross sections. In fact, ICSBEP includes reactivity coefficient results as “Supplemental Measurements” in appendices for a handful of older benchmarks. One of those benchmarks is Jezebel, the bare Pu critical assembly. This paper compares new simulations of reactivity coefficients for Jezebel, and explores the sensitivity of reactivity coefficients to small changes in nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Production and Testing of the VITAMIN-B7 Fine-Group and BUGLE-B7 Broad-Group Coupled Neutron/Gamma Cross-Section Libraries Derived from ENDF/B-VII.0 Nuclear Data

New coupled neutron-gamma cross-section libraries have been developed for use in light water reactor (LWR) shielding applications, including pressure vessel dosimetry calculations. The libraries, which were generated using Evaluated Nuclear Data File/B Version VII Release 0 (ENDF/B-VII.0), use the same fine-group and broad-group energy structures as the VITAMIN-B6 and BUGLE-96 libraries. The processing methodology used to generate both libraries is based on the methods used to develop VITAMIN-B6 and BUGLE-96 and is consistent with ANSI/ANS 6.1.2. The ENDF data were first processed into the fine-group pseudo-problem-independent VITAMIN-B7 library and then collapsed into the broad-group BUGLE-B7 library. The VITAMIN-B7 library contains data for 391 nuclides. This represents a significant increase compared to the VITAMIN-B6 library, which contained data for 120 nuclides. The BUGLE-B7 library contains data for the same nuclides as BUGLE-96, and maintains the same numeric IDs for those nuclides. The broad-group data includes nuclides which are infinitely dilute and group collapsed using a concrete weighting spectrum, as well as nuclides which are self-shielded and group collapsed using weighting spectra representative of important regions of LWRs. The verification and validation of the new libraries includes a set of critical benchmark experiments, a set of regression tests that are used to evaluate multigroup crosssection libraries in the SCALE code system, and three pressure vessel dosimetry benchmarks. Results of these tests confirm that the new libraries are appropriate for use in LWR shielding analyses and meet the requirements of Regulatory Guide 1.190.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design of UO 2 -BeO Critical Experiment at Sandia [Poster]

The purpose of this proposal is to design a new integral critical experiment to investigate the effects of beryllium oxide and high assay low-enriched uranium fuels. this proposal considers using several existing resources at Sandia: (1) the Critical Experiments (SCX) facility and water tank, (2) spare UO 2 -BeO fuel for the Annular Core Research Reactor (ACRR), and 7uPCX fuel rods from previous benchmark experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Benchmarking ENDF/B-VII.1, JENDL-4.0 and JEFF-3.1

Three nuclear data libraries have been tested extensively using criticality safety benchmark calculations. The three libraries are the new release of the US library ENDF/B-VII.1 (2011), the new release of the Japanese library JENDL-4.0 (2011), and the OECD/NEA library JEFF-3.1 (2006). All calculations were performed with the continuous-energy Monte Carlo code MCNP (version 4C3, as well as version 6-beta1). Around 2000 benchmark cases from the International Handbook of Criticality Safety Benchmark Experiments (ICSBEP) were used. The results were analyzed per ICSBEP category, and per element. Overall, the three libraries show similar performance on most criticality safety benchmarks. The largest differences are probably caused by elements such as Be, C, Fe, Zr, W. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Study of Whisper Statistics for Criticality Safety Code Validation

Whisper is computational software designed to assist with validation studies with the Monte Carlo particle transport package MCNP. Historical approaches rely on expert based judgment to select benchmarks while Whisper uses sensitivity/uncertainty (S/U) methods to select relevant benchmarks to a particular application model. Whisper will also derive a calculational margin and margin of subcriticality (MOS) that may be used to generate an upper subcritical limit (USL) for a particular application model. Whisper finds benchmark experiments whose isotope sensitivity profiles align best with the MCNP model in question, and assign a correlation coefficient ('ck' in Whisper parlance) to each selected benchmark as a measure of how closely those profiles agree. When ck values are high, there is less uncertainty between model and benchmarks and a higher USL is possible, relative to cases when ck values are low. The default Whisper settings recommends a 100,000 particles per cycle run for 500 active cycles, resulting in 50 M active neutron histories per application run. This is computationally intensive and may not be necessary to produce accurate results. A Whisper statistical study was done varying the neutron histories per cycle from 10,000 to the default 100,000. A lower number of neutron histories will allow Whisper to be used on low memory systems such as laptops. The intent of this paper is to present the changes in the Whisper results as the number of neutrons histories run is varied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resonance Parameter Adjustment Based on Integral Experiments

Our project seeks to allow coupling of differential and integral data evaluation in a continuous-energy framework and to use the generalized linear least-squares (GLLS) methodology in the TSURFER module of the SCALE code package to update the parameters of a resolved resonance region evaluation. We recognize that the GLLS methodology in TSURFER is identical to the mathematical description of a Bayesian update in SAMMY, the SAMINT code was created to use the mathematical machinery of SAMMY to update resolved resonance parameters based on integral data. Traditionally, SAMMY used differential experimental data to adjust nuclear data parameters. Integral experimental data, such as in the International Criticality Safety Benchmark Experiments Project, remain a tool for validation of completed nuclear data evaluations. SAMINT extracts information from integral benchmarks to aid the nuclear data evaluation process. Later, integral data can be used to resolve any remaining ambiguity between differential data sets, highlight troublesome energy regions, determine key nuclear data parameters for integral benchmark calculations, and improve the nuclear data covariance matrix evaluation. Moreover, SAMINT is not intended to bias nuclear data toward specific integral experiments but should be used to supplement the evaluation of differential experimental data. Using GLLS ensures proper weight is given to the differential data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integral Experiment Validation of Hafnium with TEX-HEU and TEX-Hf [Slides]

Lead by Lawrence Livermore National Laboratory under the U.S. Department of Energy's Nuclear Criticality Safety Program. The goal of TEX is to provide integral benchmark experiments than span the entire neutron energy spectrum and incorporate high-priority materials. TEX includes two test bed configurations providing a baseline for comparison to better understand the contribution of additional materials

Highly Enriched Uranium↗

TEX-HEU Baseline Assemblies: Highly Enriched Uranium Plates with Polyethylene Moderator and Polyethylene Reflector (IER-297 CED-4b Report)

This experiment provides the baseline experimental configurations for TEX-HEU. The purpose of the TEX-HEU design is to provide multiple configurations that span the entire neutron energy spectrum and can be easily modified to incorporate diluent materials. Future experiments utilizing the TEX-HEU design are planned to incorporate hafnium, lithium, and chlorine as diluent materials. Five experimental configurations were judged to be acceptable critical benchmark experiments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nuclear Data Sensitivity Study for the EBR-II Fast Reactor Benchmark Using SCALE with ENDF/B-VII.1 and ENDF/B-VIII.0

The EBR-II benchmark, which was recently included in the International Handbook of Evaluated Reactor Physics Benchmark Experiments, served as a basis for assessing the performance of the SCALE code system for fast reactor analyses. A reference SCALE model was developed based on the benchmark specifications. Great agreement was observed between the eigenvalue calculated with this SCALE model and the benchmark eigenvalue. To identify potential gaps and uncertainties of nuclear data for the simulation of various quantities of interest in fast spectrum systems, sensitivity and uncertainty analyses were performed for the eigenvalue, reactivity effects, and the radial power profile of EBR-II using the two most recent ENDF/B nuclear data library releases. While the nominal results are consistent between the calculations with the different libraries, the uncertainties due to nuclear data vary significantly. The major driver of observed uncertainties is the uncertainty of the 235 U ( n,γ ) reaction. Since the uncertainty of this reaction is significantly reduced in the ENDF/B-VIII.0 library compared to ENDF/B-VII.1, the obtained output uncertainties tend to be smaller in ENDF/B-VIII.0 calculations, although the decrease is partially compensated by increased uncertainties in 235 U fission and ν ¯ .

42 ENGINEERING↗

Development of a HEX-Z Partially Homogenized Benchmark Model for the FFTF Isothermal Physics Measurements

A series of isothermal physics measurements were performed as part of an acceptance testing program for the Fast Flux Test Facility (FFTF). A HEX-Z partially-homogenized benchmark model of the FFTF fully-loaded core configuration was developed for evaluation of these measurements. Evaluated measurements include the critical eigenvalue of the fully-loaded core, two neutron spectra, 32 reactivity effects measurements, an isothermal temperature coefficient, and low-energy gamma and electron spectra. Dominant uncertainties in the critical configuration include the placement of radial shielding around the core, reactor core assembly pitch, composition of the stainless steel components, plutonium content in the fuel pellets, and boron content in the absorber pellets. Calculations of criticality, reactivity effects measurements, and the isothermal temperature coefficient using MCNP5 and ENDF/B-VII.0 cross sections with the benchmark model are in good agreement with the benchmark experiment measurements. There is only some correlation between calculated and measured spectral measurements; homogenization of many of the core components may have impacted computational assessment of these measurements. This benchmark evaluation has been added to the IRPhEP Handbook.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Testing (Validating?) Cross Sections with ICSBEP Benchmarks [Slides]

We discuss how to use critical benchmarks from the International Handbook of Evaluated Criticality Safety Benchmark Experiments to determine the applicability of specific cross sections to the end-user's problem of interest. Particular attention is paid to making sure the selected suite of benchmarks includes the user's range of applicability (ROA).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification of MCNP Critical Benchmark Model of U233-COMP-THERM-004

Los Alamos National Laboratory (LANL) has been working on creating a new centralized repository for MCNP models of critical benchmark experiments. The initial model of U233-COMP-THERM-004 was derived from the Whisper Suite provided with MCNP6.2, and was compared against the ICSBEP handbook chapter for the benchmark. Many notable errors were found in the initial model and were revised accordingly. Comparing the computational model of the old and new models confirmed that any Whisper results that relied upon the old model are still valid.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗