Impact Analysis of Transitioning to Heat Pump Rooftop Units for the U.S. Commercial Building Stock

Twenty percent (25%) of the energy consumed by the U.S. commercial building sector is from on-site combustion of fossil fuels for space heating. Part of decarbonizing U.S. energy systems to meet climate initiatives will require electrification of space heating equipment, often by transitioning to heat pumps. Rooftop units (RTU) are the most prominent commercial building HVAC system type and should therefore be prioritized for electrification solutions. However, there is limited understanding of the impact on emissions when considering regional electricity generation methods, as well as the impact of ambient temperature on capacity and efficiency, defrost operation, realistic sizing methodologies, and supplementary heating on overall heat pump performance. This study explores the effects of transitioning all installed, existing RTUs to high-performance heat pump RTUs for the U.S. commercial building stock. The analysis is performed using ComStock (TM), the U.S. Department of Energy's calibrated model of the U.S. commercial building stock. Results show 10% and 9% reductions in stock aggregate energy consumption and greenhouse gas emissions, respectively. This analysis will help inform the transition to heat pump RTUs for the U.S. commercial building stock.

commercial building↗

Learning-Based Building Flexibility Estimation and Control to Improve Microgrid Economics and Resilience: Preprint

This paper proposes a learning-based building flexibility estimation and control framework to improve system economics and resilience. A data-driven building load flexibility model consisting of weather forecasting and estimating load consumption is proposed to quantify building heating, ventilation, and air conditioning (HVAC) load flexibility. A reinforcement learning-based microgrid controller is proposed to dispatch distributed generators, distributed energy resources, and build HVAC loads while taking flexibility information as one of the inputs. Simulation analysis is conducted on the model of a real microgrid in California. The effectiveness of the proposed learning-based building flexibility estimation and control in reducing microgrid energy costs and improving the sustainability of critical loads is demonstrated.

building load flexibility↗

Retrofittable Thermal Switches for Dynamic Building Envelopes Integrated with Thermal Energy Storage: Preprint

Buildings in the United States consume about 40 quadrillion BTU of primary energy annually, which accounts for the nation's 40% of total energy use, 75% of all electricity use, and 35% of the net carbon emissions. Deploying thermal energy storage in the form of phase change material (PCM) in building envelopes is an effective method to reduce space heating/cooling loads, provide load shedding, and shift demand to periods of lower energy cost. However, the full potential of PCM-integrated envelopes can only be realized if the PCM undergoes complete phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Conventional thermal insulation (with a fixed thermal resistance) limits PCM utilization, particularly with the increasing emphasis on higher R-value in building envelopes, which negatively affects the energy-saving potential of a PCM-integrated envelope. In contrast, dynamic building envelopes integrated with PCMs provide the option of varying the thermal resistance based on the indoor and outdoor conditions, thereby enhancing utilization of free ambient cooling and heating to charge/discharge the PCM thermal storage, reducing the buildings' heating and cooling load, and shifting the peak energy demand. In this study, we demonstrate innovative retrofittable thermal switches in the form of the insertable plugs inside an insulation to provide variable thermal resistance depending on the operating temperature and direction of temperature gradient, thus allowing preferential directional heat flow. Notably, they are passive in nature, requiring no external power, and work solely based on the ambient temperature.

buildings↗

Pushing the Envelope-Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream: Preprint

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

anisotropic envelope↗

From RNNs to Foundation Models: An Empirical Study on Commercial Building Energy Consumption

Accurate short-term energy consumption forecasting for commercial buildings is crucial for smart grid operations. While smart meters and deep learning models enable forecasting using past data from multiple buildings, data heterogeneity from diverse buildings can reduce model performance. The impact of increasing dataset heterogeneity in time series forecasting, while keeping size and model constant, is understudied. We tackle this issue using the ComStock dataset, which provides synthetic energy consumption data for U.S. commercial buildings. Two curated subsets, identical in size and region but differing in building type diversity, are used to assess the performance of various time series forecasting models, including finetuned open-source foundation models (FMs). The results show that dataset heterogeneity and model architecture have a greater impact on post-training forecasting performance than the parameter count. Moreover, despite the higher computational cost, finetuned FMs demonstrate competitive performance compared to base models trained from scratch.

commercial buildings↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

Open-cycle thermochemical energy storage for building space heating: Practical system configurations and effective energy density

Salt-hydrate thermochemical materials (TCM) are promising candidates for energy storage systems for building space heating due to their high theoretical energy density and the need for low regeneration temperature. However, water vapor is required to drive the hydration process of the TCM reactor, which poses a challenge during winter when water vapor is typically scarce. Using indoor air directly lowers the building's humidity to an unconformable level in practice, while the cold outdoor air contains limited moisture. Here we consider different integration strategies for open-cycle TCM reactors in buildings and develop a model to simulate their thermal performance across diverse buildings and climates, specifically for building space heating. The potential energy densities and the levelized cost of storage of the TCM reactor are evaluated in practical scenarios to demonstrate the load-shifting potential of TCM systems for heating applications. We use a strontium chloride (SrCl 2 )-based composite as the baseline and explore the impact of various reactor and material changes to the energy density and levelized cost of storage.

25 ENERGY STORAGE↗

An open control sequence specification to scale building demand flexibility via analytics software

For over two decades, researchers and practitioners have showcased the ability of large commercial buildings to provide grid services by shedding or shifting load. Various utility demand response (DR) and virtual power plant (VPP) programs throughout the United States are presently utilizing these demand-side resources. However, growth of these programs have been limited, in part due to the high cost necessary to integrate the DR control strategies into the building automation system (BAS). Implementing these strategies involves adjusting control sequences, necessitating dozens of hours of customized programming per building, limiting their adoption to large organizations and progressive owners. Recent efforts by researchers and industry have demonstrated the capability of energy management and information systems (EMIS), originally designed for fault detection and diagnostics, to interface with existing BAS and perform supervisory control to optimize building operations. While these approaches are quickly being adopted by industry, demand flexibility (DF) control strategies remain limited in product offerings. One of the challenges is the lack of documented best-practice DF sequences, despite the rich literature on field implementations. This paper develops a new open-specification for a zone-based temperature adjustment shed strategy for commercial building HVAC systems, describing the specification’s implementation in two EMIS tools in both experimental and field settings. Both implementations successfully reduced electric load by at least 40% on average during the called event, while maintaining temperature limits. This study’s detailed process from specification to deployment shows the potential for scalability as well as highlights challenges related to integration with heterogeneous BAS products.

Granderson, Jessica↗

Techno-economic feasibility of borehole thermal energy storage system connected to geothermal heat pumps for seasonal heating load of two buildings in Fairbanks, Alaska

Borehole thermal energy storage (BTES) is an effective solution for managing imbalanced heating and cooling loads in cold regions. This study evaluated the long-term feasibility of a BTES system in the Fairbanks area, Alaska, through building energy modeling, resource characterization, and numerical modeling. The system was designed to store waste heat from a nearby coal power plant during summer and provide thermal energy during winter to geothermal heat pumps supplying heating loads in two buildings. Heating load profiles were modeled for the buildings using EnergyPlus, and the results indicated the annual heating load was 5.6 times greater than the cooling load. 40 borehole heat exchangers were pre-designed approximately 100 m away from the two buildings in terms of land availability and regulatorily optimized depth. The 20-year performance of the designed BTES system under two operational scenarios—one with a 5-year preheating period and one without—was numerically modeled using subsurface temperature and properties characterized through the literature review and thermal response tests. Both scenarios demonstrated that the BTES has the capacity to fully cover the heating loads in the two buildings throughout the 20-year lifetime. Production temperatures at central wells were 33 % higher on average than at outer wells in both scenarios. The 5-year preheating period increased subsurface and extraction temperatures, and correspondingly annual average and total thermal energy production was higher for 8 years than in the scenario without the preheating period. These results highlight the long-term reliability and sustainability of the BTES system in meeting heating demands over its lifetime, with the preheating period offering potential performance improvements. Implementing the BTES system in cold regions with high heating demand, such as Fairbanks, Alaska, could provide a long-term, sustainable energy solution for managing imbalanced heating and cooling loads.

15 GEOTHERMAL ENERGY↗

A building performance-based approach to determining energy resilience for grocery stores in the event of a power outage

Evaluating progress toward a built environment that is best equipped to serve communities during a regional power outage will require metrics that capture the energy resilience of the unique buildings and businesses most crucial to the well-being of those nearby. We focused on grocery stores as key buildings for which access, and thus energy resilience, is critical during a disaster when power is unavailable. We evaluated the energy resilience of these buildings by offering and testing building-scale metrics that assess business continuity potential during a power outage. Metrics proposed in this study are calculated based on the unique power loads characteristic to grocery stores, primarily refrigeration and maintaining safe indoor environmental conditions. Building simulations based on varying levels of backup power were carried out against occupant safety and comfort parameters to apply these metrics, with additional criteria imposed on grocery stores to capture the inventory and sales loss from food spoilage resulting from a lack of refrigeration power. Findings from this study demonstrate the feasibility of our proposed metrics and methodology to serve as a low-data burden means for stakeholders to evaluate the energy resilience of grocery stores, with greater implications in helping to understand the impact on community-scale energy resilience.

Siegel, Lino Sanchez↗

Online Dynamic Mode Decomposition Based System Identification of Multi-Zone Building HVAC Systems

Many works have recently been conducted to reduce the electricity consumption of smart buildings and allow them to support various grid services. Most of these works require accurate system models for the various appliances in the building including heating, ventilation, and air conditioning (HVAC) units. In this paper, we investigate a recursive data-driven system identification strategy to construct the thermal model for a time-varying building with a multi-zone HVAC unit. The online dynamic mode decomposition (DMD)-based strategy is employed to identify the multi-zone thermal building dynamics, where a simple information update (rank-1) is selected to avoid computational complexity. The DMD-based identification strategy is validated using a real gymnasium building equipped with a 4-zone HVAC unit, and its performance is compared with that of the traditional nuclear-norm subspace identification (N2SID) strategy.

Wu, Tumin [University of Tennessee, Knoxville (UTK↗

From Bricks to Clicks: Mapping the White Space in Building Innovation

It is a critical national imperative to transform the buildings sector, yet innovation is impeded by deployment failures that leave promising technologies stranded. Conventional market reports and techno-economic analysis provide an insufficient understanding of markets and resource allocation for emerging building technologies. They omit crucial commercialization factors such as ecosystem maturity and adoption friction, where the coordinated participation of a network of suppliers, contractors, financiers, regulators, and integrators is required to scale solutions. This study addresses these gaps by introducing an evaluation framework grounded in front-line data from six years of the DOE's IMPEL incubator, comprising experience from 300 building-sector innovators and the adjacent, complex ecosystem. Our methodology synthesizes top-down market analysis with bottom-up, practitioner-level data across five megatrends: (M1) Affordable materials and industrialized construction; (M2) Healthy and efficient mechanical systems; (M3) Intelligent building operations; (M4) Buildings as grid assets; and (M5) High-density power and cooling for data centers and therein identify twelve "white space" technology opportunities. Next, we develop a multi-criteria scoring rubric to rank these opportunities based on parameters, i.e., Affordability, Quality of Life, Reliability, and Security, yielding composite ‘Demand’ and ‘Maturity’ indices. Our results indicate that the most significant white spaces may not be incremental products but a new class of ‘Ecosystem Enablers’, such as logistics platforms, orchestration layers, and automated compliance software that solve structural deployment gaps. This paper summarizes this transparent, evidence-based, practitioner-informed evaluation framework for policymakers and investors to re-evaluate policy and resource allocation and unlock scalable market transformation.

Singh, Reshma↗

Salt Hydrate Eutectic Thermal Energy Storage for Building Thermal Regulation (Final Technical Report)

Thermal energy storage is anticipated to play an important role in developing the power grid of the future - a power grid that meets increasing demands of users, is resistant to disruptions, but also allows for greater penetration of renewable resources. Specifically, thermal energy storage materials can be integrated into HVAC systems and building envelopes, where they can be used to shift power demands for building climate control from periods of peak demand to periods of low demand. Phase change materials (PCMs) are compelling as low-cost, high energy density thermal energy storage materials for building thermal management. However, there is a lack of high performance low-cost PCMs within the specific temperature ranges which would most effectively allow for power load shifting. Inorganic salt hydrates represent a promising class of PCMs, but their inherent limitations cause them to be currently unavailable for reliable building applications. The overarching goals of this research effort are to: 1) Discover low-cost, high volumetric density salt hydrate eutectic PCMs to store low-quality heat (10 to 40 °C); 2) Introduce a high thermal conductivity matrix to reduce the time constant for energy storage to ~0.1 to 1 hr, incorporate nucleation catalysts to decrease undercooling, and utilize microencapsulation and shape stabilization approaches, minimizing moisture loss/gain, mitigating phase separation, and maintaining stable melting behavior over the lifetime of the compounds; 3) Evaluate the impact these systems have on peak load shifting, and the potential for overall energy savings under different climatic scenarios and building configurations. These goals will be achieved by an integrated research program consisting of six cohesive research subtasks: 1) Materials discovery of eutectic salt hydrate PCMs by using computationally predicted thermodynamic equilibria, coupled with high-throughput experimental validation, 2) Rapid experimental screening of nucleation catalysts identified through robust computational databases, 3) Embedding salt hydrate PCM into a low cost and scalable high conductivity matrix, 4) Microencapsulation of salt hydrate microspheres using hybrid inorganic-polymer microencapsulation approach, 5) Shape stabilization by thermoreversible salt hydrate salogels, and 6) Analysis of end-use using thermal simulations, and characterization of mock-up energy storage finished components.

25 ENERGY STORAGE↗

Commercial Building Prototypes Based on ANSI/ASHRAE/IES Standard 90.1-2019 Appendix G PRM: Technical Support Document

The two paths for documenting compliance with ANSI/ASHRAE/IES Standard 90.1 are the prescriptive path and the performance path. Beyond code programs and rating systems (for example, USGBC-LEED ) are primarily known to use a third path – the Appendix G Performance Rating Method. An update in the 2016 edition of Standard 90.1 approved the Appendix G Performance Rating System for code compliance, extending its application and allowing for greater consistency of modeling rules for code and beyond code building energy modeling. The Appendix G PRM provides rules for the development of whole building energy models of baseline and proposed models for calculating the “performance cost index target” value using the simulated energy results of the baseline and proposed models and the building performance factors published in Table 4.2.1.1 of the Standard. This report documents (1) the methodology used for development of the baseline and proposed energy models of the Pacific Northwest National Laboratory and U.S. Department of Energy commercial building prototypes using the Appendix G Performance Rating Method; and (2) the building performance factors that were calculated using those models.

97 MATHEMATICS AND COMPUTING↗

Demonstration and Validation of a Virtual Energy Audit Tool for DoD Buildings

Electricity consumption has been in the spotlight as part of the battle for sustainability resulting in legislative measures to try and reduce the amount of energy used. EISA 432 and the Energy Act of 2020 are two examples that require federal facilities to investigate buildings and find saving opportunities through energy audits. EDIFES solves this problem by providing fully virtual audits. Only five inputs are needed (15-minute interval electricity consumption, location, square footage, number of stories, and building end use) to produce complete energy audits. The virtual audit is automated, making them inexpensive and the small number of inputs allows a large number of buildings to be entered quickly. During this project, EDIFES performed energy audits on hundreds of buildings to ensure proper functionality and workflow. Over 250 DoD buildings received energy audits that then had their results posted to an interactive dashboard with portfolio rankings. Several validation methods were employed. All confirmed that EDIFES's methods worked as expected and with a high degree of accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency Analysis and Grid Service Results for Commercial Buildings using the VOLTRON IoT Platform

In fiscal year 2021 (FY21), the Commercial Buildings Integration Program (CBI) within the Building Technologies Office (BTO), funded PNNL to conduct a field evaluation of the AIRCx and ILC using an Internet-of-Things (IoT) platform, VOLTTRON. The primary goal of the project is to show that software solutions deployed and delivered through an IoT-platform can identify energy efficiency opportunities and manage peak load (beyond the traditional demand response) in commercial buildings. There are also two secondary goals: 1) show that the energy efficiency solutions will result in identification of significant savings opportunities (10% to 30%) as well as energy cost reductions (10% to 15%) by managing the peak load in commercial buildings, and 2) show that an IoT-based software solution is more cost-effective compared to a manual process in meeting the Re-tuning/retro commissioning (RCx) mandates and there is a pathway for broader adoption of this approach. This report provides AIRCx and ILC results for two building located in District of Columbia managed by the energy service provider Intellimation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Fidelity Building Emulator for Integrated Comfort and Energy Analysis using EnergyPlus and Radiance

The growing need for smart, energy-efficient, and occupant-centric buildings has created a demand for advanced control systems that can optimize building operations to balance energy savings, demand flexibility, and comfort. However, current building energy simulation tools, such as EnergyPlus, have limitations that hinder the development and evaluation of these complex control systems. To address this challenge, we introduce a high-fidelity building emulator that dynamically couples EnergyPlus with Radiance for enhanced daylight modeling. The introduced workflow allows researchers and practitioners to rapidly develop and evaluate innovative control solutions. An example study looking at a south-facing office zone revealed up to 67% deviation in predicted light levels, which can significantly impact building assessment.

Yu, Tammie↗

Building Fraction and Mean Height for Los Angeles (2010 and 2020) at 30 m Resolution

This dataset provides 30 m resolution spatial layers of building fraction and mean building height for the Los Angeles metropolitan region for 2010 and 2020. Derived from the Model America version 2 building dataset, it represents the distribution of total building footprint area and average building height across the metropolitan region, offering a consistent geospatial resource for urban analysis. The dataset is intended to support applications in urban climate studies, land-use assessment, city-scale modeling, and planning by enabling comparison of urban form characteristics over time. Additional dataset details including data processing details are provided in the Readme document (README_LA_BF_MeanHeight_2010_2020 1.txt).

geospatial↗