Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building energy and control system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A Modular Optimal Power Flow Method for Integrating New Technologies in Distribution Grids

This work proposes a modular concept to build optimal power flow (OPF) models for distribution networks containing various emerging technologies under diverse ownership structures, to efficiently deal with evolving technology capabilities and information sharing or privacy constraints. This concept will support any typical OPF application (e.g., optimal dispatch of a given asset without violating grid constraints) by coordinating between grid module and technology module without the need to recreate various modeling elements as technology capability changes due to innovation. Moreover, the modularity of the proposed concept enables achieving system level objectives without sharing detailed information on module level objectives and constraints among modules. To achieve this, the proposed work develops a gradient-descent algorithm which builds upon the literature on the state-of-the-art power flow approximation. The proposed concept is demonstrated with two case studies of i) controllable loads and ii) battery energy storage system (BESS) on an actual large-scale distribution grid.

Hanif, Sarmad↗

HP-FLEX MPC v0.1.0

HP-FLEX MPC is control software developed by Lawrence Berkeley National Laboratory with support from the California Energy Commission (CEC) through EPIC-19-301. HP-FLEX aims to provide load flexibility for heat pumps (HPs) in response to dynamic grid signals (including Time-of-Use, Dynamic Pricing, and Critical Peak Pricing) while maintaining thermostat temperatures within user-specified bounds. The software includes a system-identification module, which models the dynamics of the building envelope with thermostat data, and a control module based on a model predictive controller (MPC) to make optimal decisions. HP-FLEX receives forecasts of outdoor air temperature, solar irradiation, and internal gain (if available), as well as trajectories of energy price, temperature lower and upper bounds over a prediction horizon. It then optimizes heating and cooling capacities to minimize energy cost and peak power (with a user-defined weight on peak power) over the prediction horizon, while maintaining room air temperature within the temperature constraints, and outputs the optimal thermostat setpoints.

Kim, Donghun↗

Implementation and test of an automated control hunting fault correction algorithm in a fault detection and diagnostics tool

Control hunting due to improper proportional–integral–derivative (PID) parameters in the building automation system (BAS) is one of the most common faults identified in commercial buildings. It can cause suboptimal performance and early failure of heating, ventilation, and air conditioning (HVAC) equipment. Commercial fault detection and diagnostics (FDD) software represents one of the fastest growing market segments in smart building technologies in the United States. Implementation of PID retuning procedures as an auto-correction algorithm and integration into FDD software has the potential to mitigate control hunting across a heterogeneous portfolio of buildings with different BAS in a scalable way. This paper presents the development, implementation, and field testing of an automated control hunting fault correction algorithm based on lambda tuning open-loop rules. The algorithm was developed in a commercial FDD software and successfully tested among nine variable air volume boxes in an office building in the United States. The paper shows the feasibility of using FDD tools to automatically correct control hunting faults, discusses scalability considerations, and proposes a path forward for the HVAC industry and academia to further improve this technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intelligent multi-zone residential HVAC control strategy based on deep reinforcement learning

Residential heating, ventilation, and air conditioning (HVAC) has been considered as an important demand response resource. However, the optimization of residential HVAC control is no trivial task due to the complexity of the thermal dynamic models of buildings and uncertainty associated with both occupant-driven heat loads and weather forecasts. In this paper, we apply a novel model-free deep reinforcement learning (RL) method, known as the deep deterministic policy gradient (DDPG), to generate an optimal control strategy for a multi-zone residential HVAC system with the goal of minimizing energy consumption cost while maintaining the users’ comfort. Here, the applied deep RL-based method learns through continuous interaction with a simulated building environment and without referring to any prior model knowledge. Simulation results show that compared with the state-of-art deep Q network (DQN), the DDPG-based HVAC control strategy can reduce the energy consumption cost by 15% and reduce the comfort violation by 79%; and when compared with a rule-based HVAC control strategy, the comfort violation can be reduced by 98%. In addition, experiments with different building models and retail price models demonstrate that the well-trained DDPG-based HVAC control strategy has high generalization and adaptability to unseen environments, which indicates its practicability for real-world implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Evaluation of Occupancy-Aware HVAC Control for Residential Building Energy Efficiency and Occupant Comfort

Occupancy-aware heating, ventilation, and air conditioning (HVAC) control offers the opportunity to reduce energy use without sacrificing thermal comfort. Residential HVAC systems often use manually-adjusted or constant setpoint temperatures, which heat and cool the house regardless of whether it is needed. By incorporating occupancy-awareness into HVAC control, heating and cooling can be used for only those time periods it is needed. Yet, bringing this technology to fruition is dependent on accurately predicting occupancy. Non-probabilistic prediction models offer an opportunity to use collected occupancy data to predict future occupancy profiles. Smart devices, such as a connected thermostat, which already include occupancy sensors, can be used to provide a continually growing collection of data that can then be harnessed for short-term occupancy prediction by compiling and creating a binary occupancy prediction. Real occupancy data from six homes located in Colorado is analyzed and investigated using this occupancy prediction model. Results show that non-probabilistic occupancy models in combination with occupancy sensors can be combined to provide a hybrid HVAC control with savings on average of 5.0% and without degradation of thermal comfort. Model predictive control provides further opportunities, with the ability to adjust the relative importance between thermal comfort and energy savings to achieve savings between 1% and 13.3% depending on the relative weighting between thermal comfort and energy savings. In all cases, occupancy prediction allows the opportunity for a more intelligent and optimized strategy to residential HVAC control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Commercial Building Lighting as a Frequency Regulation Resource

This paper evaluates the potential for automated lighting control as a resource for frequency regulation of the electric grid system in the context of current energy policies, economic incentives, and technological trends. The growing prevalence of renewable energy has increased the need for ancillary services to maintain grid frequency and stability. While demand side resources like heating, ventilating, and air-conditioning systems, as well as water treatment plants are already evaluated as regulation service providers, the potential application to electrical lighting systems has largely been ignored. Yet, aggregations of lighting systems that are retrofitted with intelligent controls could conceivably contribute to frequency regulation services with little impact on user comfort. To further explore the feasibility of lighting potential, this paper explores (1) how lighting control systems are limited by visual comfort perception and acceptability, (2) how such limitations impact the performance of the lighting system as an frequency regulation resource, and (3) how the market potential of lighting systems as demand side resources compares in different regional transmission organizations. Finally, the impact of developing technologies on the application of lighting systems for frequency regulation is discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Heat Recovery with Storage: Control Validation and Sensitivity Analysis of the Time-Independent Energy Recovery Plant Using Modelica

Heat recovery in large building central plants saves energy but traditionally requires simultaneous heating and cooling. The Time-Independent Energy Recovery (TIER) plant shifts this paradigm by integrating thermal energy storage (TES) to enable heat recovery regardless of concurrent demand, offering a highly efficient, space-saving solution to achieve California’s energy goals. However, its integration of heat recovery chillers, cooling-only chillers, cooling towers, and trim air-source heat pumps (ASHPs) creates growing control and sizing complexity. To overcome this, this study employs high-fidelity Modelica dynamic simulation to validate TIER control sequences and optimize equipment sizing. We translated the written Sequences of Operation into executable Control Description Language (CDL) to test logic against sub-hourly loads. This verification workflow successfully identified and resolved critical vulnerabilities, such as thermal storage freezing and equipment short-cycling, in a virtual environment prior to physical deployment. Then, the study analyzes TIER plant performance across three simulated building types in three locations, and a real building load profile, ensuring variety in heating and cooling loads, and simultaneity factors and explores sizing rules for the TES and ASHP capacity. The analysis shows that the TIER plant operates equipment efficiently leading to a plant SCOP of around 7.5 across all scenarios, higher than a traditional ASHP plant, and a viable pathway to de-risk complex system design and control through simulation to identify optimal designs that maximize energy efficiency, minimize operational costs, and ensure robust operation in varied environmental conditions, thereby facilitating the broader adoption of such a solution for large buildings.

Zanetti, Ettore↗

Frequency Analysis of Solar PV Power to Enable Optimal Building Load Control

In this paper, we present a flexibility estimation mechanism for buildings’ thermostatically controlled loads (TCLs) to enable the distribution level consumption of the majority of solar photovoltaic (PV) generation by local building TCLs. The local consumption of PV generation provides several advantages to the grid operation as well as the consumers, such as reducing the stress on the distribution network, minimizing voltage fluctuations and two-way power flows in the distribution network, and reducing the required battery storage capacity for PV integration. This would result in increasing the solar PV generation penetration levels. The aims of this study are twofold. First, spectral (frequency) analyses of solar PV power generation together with the power consumption of multiple building TCLs (such as heating, ventilation, and air conditioning (HVAC) systems, water heaters, and refrigerators) are performed. These analyses define the bandwidth over which these TCLs can operate and also describe the PV generation frequency bandwidth. Such spectral analyses, in frequency domain, can help identify the flexible components of PV generation that can be consumed by the various TCLs through optimal building load utilization. Second, a quadratic optimization problem based on model predictive control is formulated to allow consuming most of the low and medium frequency content of the PV power locally by building TCLs, while maintaining occupants’ comfort and TCLs’ physical constraints. The solution to the proposed optimization problem is achieved using optimal control strategies. Numerical results show that most of the low and medium frequency content of the PV generation can be consumed locally by building TCLs. The remaining high-frequency content of the PV generation can then be stored/offset using energy storage systems.

14 SOLAR ENERGY↗

Hierarchical Model-Free Transactive Control of Building Loads to Support Grid Services

Residential buildings consume 4.4 quads of electricity annually, approximately 37% of the total electricity consumption in the United States. This represents a vast resource that can be used for demand management and other ancillary services. This project aims to develop a robust, scalable hierarchical transactional control mechanism incorporating elements of model-free control (MFC) and game theory to harness buildings to provide ancillary services to the grid. This approach is being taken to address the challenges of incorporating traditional transactional control schemes into existing buildings. The challenges include small individual building sizes requiring aggregation of many buildings, unpredictable energy usage that makes model identification difficult, and satisfying the sensitive occupant comfort constraints. In the proposed approach, by separating the control mechanism into two layers above and below the load aggregator, MFC can be used below the aggregator to modulate flexible building loads in response to pricing signals with guaranteed performance. This allows the burden of identifying an accurate model of the system to be shifted to the above-aggregator layer, where fluctuations in individual building usage have less impact on predicted building system behavior. Game theory concepts can then be used to determine pricing curves and control signals among regional aggregators. Managing this control in a game-theoretic approach will allow us to build in financial incentives that increase customer engagement. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable on small, embedded devices. In a broader sense, developing a strategy capable of effectively incorporating residential and small commercial buildings will allow greater throughput of existing and emerging grid services in addition to future transactive energy grid management methods. Using MFC within a hierarchical control architecture will allow the shifting of existing forecasting challenges to an aggregate level, where dynamics are slower and more predictable. This will enable a smooth interface between the grid services requests of utilities and the reliable control required by participating buildings. MFC, which supports distributed control architecture, permits a scalable solution that can be deployed to neighborhood-size systems as well as individual buildings. This project focuses on three objectives: (1) developing the mathematical framework, algorithm toolkit, and software toolset of the two-layer transactive control testbed; (2) developing a scalable solution for application over many residential and small-size commercial buildings with sparse distributed communication; and (3) field testing and implementation on hardware of the control strategies developed in the previous two objectives. The research and development activities are focused and designed to be impactful within the relevant 2025 targets timeframe. An open-source control framework for exploiting variability and dispatchability of building loads will be delivered as the outcome of the project. This capability enables greater participation of loads in electricity markets and ancillary services that are both useful for the utility and financially beneficial for building owners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

AI-Driven Smart Community Control for Accelerating PV Adoption and Enhancing Grid Resilience

Rapid deployment of residential photovoltaic (PV) systems helps decarbonize our electricity supplies, but under certain circumstances, high-penetration PV may pose challenges to the electrical distribution grid. In a project funded by the U.S. Department of Energy's Solar Energy Technologies Office and Building Technologies Office, the National Renewable Energy Laboratory and its partners studied how flexible building loads and battery storage, when coordinated at home-level and community-level scales, can be used to address those challenges and enhance grid resilience. In this webinar, we will discuss the methodology, simulation and field pilot results, insights from partners, and lessons learned from the project.

artificial intelligence↗

Utilizing commercial heating, ventilating, and air conditioning systems to provide grid services: A review

The modern power grid faces multiple challenges due to an increase in the adoption of renewable generation, such as dynamically balancing supply and demand at different time scales. Demand side management in buildings plays a vital role in achieving this balance because buildings can provide grid services through a variety of building assets. However, the development of grid-interactive, efficient buildings is still in its infancy, and a systematic and holistic understanding of grid service delivery strategies in terms of energy efficiency, load shifting, load shedding and load modulating is still limited. This paper is a comprehensive review of the development and application of building-level control strategies for utilizing heating, ventilating, and air conditioning systems to provide grid services. These strategies have been investigated through numerical and experimental studies. Control algorithms, such as heuristic rule-based control and model-based control, have been used to enable the automatic control delivery of grid services. The advantages and disadvantages of the strategies are summarized and discussed. Finally, research trends are also identified, which include considering predicted mean vote-based and occupant-based thermal comfort, modeling of occupant behavior, integrating power grid operations with building control, and combining different demand flexibility modes in the control design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Static Subspace Approximation for Random Phase Approximation Correlation Energies: Implementation and Performance

Developing theoretical understanding of complex reactions and processes at interfaces requires using methods that go beyond semilocal density functional theory to accurately describe the interactions between solvent, reactants and substrates. Methods based on many-body perturbation theory, such as the random phase approximation (RPA), have previously been limited due to their computational complexity. However, this is now a surmountable barrier due to the advances in computational power available, in particular through modern GPU-based supercomputers. In this work, we describe the implementation of RPA calculations within BerkeleyGW and show its favorable computational performance on large complex systems relevant for catalysis and electrochemistry applications. Our implementation builds off of the static subspace approximation which, by employing a compressed representation of the frequency dependent polarizability, enables the evaluation of the RPA correlation energy with significant acceleration and systematically controllable accuracy. We find that the computational cost of calculating the RPA correlation energy scales only linearly with system size for systems containing up to 50 thousand bands, and is expected to scale quadratically thereafter. We also show excellent strong scaling results across several supercomputers, demonstrating the performance and portability of this implementation.

algorithmic development↗

Sensor Incipient Fault Impacts on Building Energy Performance: A Case Study on a Multi-Zone Commercial Building

Existing studies show sensor faults/error could double building energy consumption and carbon emissions compared with the baseline. Those studies assume that the sensor error is fixed or constant. However, sensor faults are incipient in real conditions and there were extremely limited studies investigating the incipient sensor fault impacts systematically. This study filled in this research gap by studying time-developing sensor fault impacts to rule-based controls on a 10-zone office building. The control sequences for variable air volume boxes (VAV) with an air handling unit (AHU) system were selected based on ASHRAE Guideline 36-2018: High-Performance Sequences of Operation for HVAC Systems. Large-scale simulations on cloud were conducted (3600 cases) through stochastic approach. Results show (1) The site energy differences could go –3.3% lower or 18.1% higher, compared with baseline. (2) The heating energy differences could go –66.5% lower or 314.4% higher, compared with baseline. (3) The cooling energy differences could go –11.5% lower or 65.0% higher, compared with baseline. (4) The fan energy differences could go 0.15% lower or 6.9% higher, compared with baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Separate sensible and latent cooling: Carnot limits and system taxonomy

Energy efficiency and thermal comfort can be improved by independent control of temperature and humidity. In recent work, an emerging class of cooling systems known as separate sensible and latent cooling (SSLC) systems have demonstrated 14 to 47% energy savings, while simultaneously providing better comfort control than conventional air conditioning. In this work, SSLC is defined as using two or more cooling processes with unequal sensible heat ratio (SHR) to control temperature and humidity independently and dynamically. Fundamental efficiency limits of SSLC systems are developed for the first time, demonstrating that the Carnot efficiency for SSLC is higher than that of conventional systems. It is revealed that SSLC has particularly high potential for moderate outdoor temperatures, high sensible building loads, and drier indoor conditions. Additionally, this work proposes a classification scheme for SSLC systems, revealing an enormous number of feasible cycle permutations. This provides a framework for the important research task of developing SSLC systems that will save energy, be practical to construct, and be controllable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CityLearn v2: energy-flexible, resilient, occupant-centric, and carbon-aware management of grid-interactive communities

As more distributed energy resources become part of the demand-side infrastructure, quantifying their energy flexibility on a community scale is crucial. CityLearn v1 provided an environment for benchmarking control algorithms. However, there is no standardized environment utilizing realistic building-stock datasets for distributed energy resource control benchmarking without co-simulation or third-party frameworks. CityLearn v2 extends CityLearn v1 by providing a stand-alone simulation environment that leverages the End-Use Load Profiles for the U.S. Building Stock dataset to create grid-interactive communities for resilient, multi-agent, and objective control of distributed energy resources with dynamic occupant feedback. While the v1 environment used pre-simulated building thermal loads, the v2 environment uses data-driven thermal dynamics and eliminates the need for co-simulation with building energy performance software. This work details the v2 environment and provides application examples that use reinforcement learning control to manage battery energy storage system, vehicle-to-grid control, and thermal comfort during heat pump power modulation.

Nweye, Kingsley↗

Foil deposition onto an additive manufactured substrate

An additive manufacturing system and method for forming a part of dissimilar materials. The additive manufacturing system may include a build platform, a recoater for dispensing build powder onto the build platform, an energy source, a foil feed assembly, and a controller for controlling actuation of these components. The method of forming the part may include the steps of depositing a layer of build powder onto the build platform surface, melting selected portions of the layer of build powder, applying a sheet of foil over the layer of build powder, melting selected portions of the sheet of foil onto the layer of build powder, removing the sheet of foil from the layer of build powder, and then lowering the build platform surface to prepare for deposition of a next layer of the build powder. These steps are then repeated one or more times, thereby forming the part.

36 MATERIALS SCIENCE↗

Foil deposition onto an additive manufactured substrate

An additive manufacturing system and method for forming a part of dissimilar materials. The additive manufacturing system may include a build platform, a recoater for dispensing build powder onto the build platform, an energy source, a foil feed assembly, and a controller for controlling actuation of these components. The method of forming the part may include the steps of depositing a layer of build powder onto the build platform surface, melting selected portions of the layer of build powder, applying a sheet of foil over the layer of build powder, melting selected portions of the sheet of foil onto the layer of build powder, removing the sheet of foil from the layer of build powder, and then lowering the build platform surface to prepare for deposition of a next layer of the build powder. These steps are then repeated one or more times, thereby forming the part.

Green, Nicholas↗

Foil deposition onto an additive manufactured substrate

An additive manufacturing system and method for forming a part of dissimilar materials. The additive manufacturing system may include a build platform, a recoater for dispensing build powder onto the build platform, an energy source, a foil feed assembly, and a controller for controlling actuation of these components. The method of forming the part may include the steps of depositing a layer of build powder onto the build platform surface, melting selected portions of the layer of build powder, applying a sheet of foil over the layer of build powder, melting selected portions of the sheet of foil onto the layer of build powder, removing the sheet of foil from the layer of build powder, and then lowering the build platform surface to prepare for deposition of a next layer of the build powder. These steps are then repeated one or more times, thereby forming the part.

Green, Nicholas↗