Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Direct Observations of Solute Dispersion in Rocks With Distinct Degree of Sub‐Micron Porosity

Abstract The transport of chemical species in rocks is affected by their structural heterogeneity to yield a wide spectrum of local solute concentrations. To quantify such imperfect mixing, advanced methodologies are needed that augment the traditional breakthrough curve analysis by probing solute concentration within the fluids locally. Here, we demonstrate the application of asynchronous, multimodality imaging by X‐ray computed tomography (XCT) and positron emission tomography (PET) to the study of passive tracer experiments in laboratory rock cores. The four‐dimensional concentration maps measured by PET reveal specific signatures of the transport process, which we have quantified using fundamental measures of mixing and spreading. We observe that the extent of solute spreading correlate strongly with the strength of subcore‐scale porosity heterogeneity measured by XCT, while dilution is enhanced in rocks containing substantial sub‐micron porosity. We observe that the analysis of different metrics is necessary, as they can differ in their sensitivity to the strength and forms of heterogeneity. The multimodality imaging approach is uniquely suited to probe the fundamental difference between spreading and mixing in heterogeneous media. We propose that when multi‐dimensional data is available, mixing and spreading can be independently quantified using the same metric. We also demonstrate that one‐dimensional transport models have limited predictive ability toward the internal evolution of the solute concentration, when the model is solely calibrated against the effluent breakthrough curves. The data set generated in this study can be used to build realistic digital rock models and to benchmark transport simulations that account deterministically for rock property heterogeneity.

Kurotori, Takeshi [Department of Chemical Engineer↗

Sienna Modeling Framework [Slides]

NREL's Sienna modeling framework effectively builds, solves, and analyzes the scheduling problems and dynamic simulations of quasi-static infrastructure systems. It uses a modular framework to answer different questions about future energy systems, fundamentally advancing the nation's ability to model individual and integrated infrastructure systems at a range of spatial and temporal scales. This presentation will include NREL power grid researcher Clayton Barrows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High y + Shear-Stress Turbulence Implementation for High Flux Isotope Reactor Narrow Channel Flows

The research objective of this work was to improve the engineering predictions of the turbulence characteristics of flows in curved narrow channels. Such channel flows are commonly encountered in nuclear research and test reactors, with one of them being the high-flux isotope reactor (HFIR). Research reactors bear high heat fluxes, and the proper computing of turbulence is paramount for safe and reliable reactor operation. The study builds on the results of a previous direct numerical simulation of turbulence to inform a well-known Reynolds-averaged Navier–Stokes shear-stress turbulence model and improves its accuracy in simulating parallel channel flows. A new formulation of the loss term in the dissipation conservation equation is suggested. Combined with high wall distance computational grids, the new implementation provides a fast-running flow solution, suitable for engineering purposes. Model generalization for parallel channel flows, in a broader range of frictional Reynolds numbers, is suggested by introducing a new form of the model constants.

CFD↗

EFT Workshop at Notre Dame

The LPC EFT workshop was held April 25-26, 2024 at the University of Notre Dame. The workshop was organized into five thematic sessions: "how far beyond linear" discusses issues of truncation and validity in interpretation of results with an eye towards practicality; "reconstruction-level results" visits the question of how best to design analyses directly targeting inference of EFT parameters; "logistics of combining likelihoods" addresses the challenges of bringing a diverse array of measurements into a cohesive whole; "unfolded results" tackles the question of designing fiducial measurements for later use in EFT interpretations, and the benefits and limitations of unfolding; and "building a sample library" addresses how best to generate simulation samples for use in data analysis. This document serves as a summary of presentations, subsequent discussions, and actionable items identified over the course of the workshop.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Building confidence in models for complex barrier systems for radionuclides

The modeling and simulation of the Cement-clay Interaction-Diffusion field (CI-D) experiment at the Mont Terri site in Switzerland presented here demonstrates that it is possible to capture the multiscale physical and chemical features of natural and engineered barrier systems for radionuclides. The simulations are successfully carried out with the newly developed CrunchODiTi high-performance computing software that accounts for multiple continua, including a continuum representing the electrical double layer (EDL) developed along negatively charged clay particles in clay rock. The simulation also accounts for both the complex three-dimensional (3D) geometry, expected as the norm in a geological waste repository, and the anisotropy of the geological formation. In addition, the high resolution of the model makes it possible to include "skin effects" developed at the interface between highly reactive materials, in this case between the high pH cement and the circumneutral but electrostatic Opalinus Clay. The successful history matching with the field experiment demonstrates that the distinct geochemical and physical properties of the cement and the Opalinus Clay in the CI-D experiment can be accounted for. Such analyses are essential for developing a defensible safety case for the underground storage of radioactive waste.

Sarsenbayev, Dauren↗

A Versatile Simulated Data Transport Layer for in Situ Workflows Performance Evaluation

In situ processing does not only allow scientific applications to face the explosion in data volume and velocity but also to address the time constraints of many simulation-analysis workflows by providing scientists with early insights about their applications at runtime. Multiple frameworks implement the concept of a data transport layer (DTL) to enable such in situ workflows. These tools are very versatile, directly or indirectly access the data generated on the same node, another node of the same compute cluster, or a completely distinct node, and allow data publishers and subscribers to run on the same computing resources or not. This versatility puts on researchers the onus of taking key decisions related to resource allocation and how to transport data to ensure the most efficient execution of their in situ workflows. However, domain scientists and workflow practitioners lack the appropriate tools to assess the respective performance of particular design and deployment options. In this paper we introduce a versatile simulated DTL designed to provide researchers with insights on the respective performance of different execution scenarios of in situ workflows. This open-source, standalone library builds on the SimGrid toolkit and can be linked to any SimGrid-based simulator. It facilitates the evaluation of the performance behavior, at scale, of different data transport configurations and the study of the effects of resource allocation strategies. We demonstrate the scalability, versatility, and accuracy of this simulated DTL by reproducing the execution of two synthetic benchmarks and of a real-world in situ workflow composed of an MPI application and a parallel data analysis. Results of simulations run on a single core show that the proposed library can simulate the interactions of tens of thousands of simulated processes deployed on two interconnected commodity clusters in a few seconds, and the execution by a thousand simulated processes of an in situ workflow in less than three minutes.

Suter, Fred [ORNL] (ORCID:0000000319021955)↗

The hygrothermal performance of continuous and cavity wood fiber insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Hygrothermal Performance of Continuous and Cavity Wood Fiber Insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

UrbanScaping: Community Spatial Data Visualization & Analytics

Evaluating the electrification potential of buildings through retrofitting is crucial for reducing carbon emissions and the carbon footprint of built environments. This study leverages the Automatic Building Energy Modeling (AutoBEM) software, integrating the Model America database to create an urban context-based spatial analysis platform for community engagement and development. We selected Camp Hill Borough, PA, as a case study to analyze building-specific energy performance and evaluate the electrification potential of each building by switching to different Heating, Ventilation, and Air Conditioning (HVAC) systems and measurement components. The simulation results generated by the workflow provide retrofitting suggestions to help mitigate the carbon footprint as well as energy saving statistics of buildings. Additionally, the developed web-based interface serves as a community engagement platform, allowing residents to provide feedback and further develop interactive communication protocols. The outcomes of this project offer a baseline for community electrification planning and contribute to the design of low-carbon communities.

Chowdhury, Shovan [ORNL]↗

Geothermal-integrated thermally anisotropic building envelope for energy and peak-demand reduction

Buildings consume large amounts of energy for heating and cooling, while peak electricity demand places significant stress on the power grid. This paper presents a reduced-order co-simulation framework and load-oriented supervisory control strategy for a geothermal-integrated thermally anisotropic building envelope with a ground loop (TABE+GL). In TABE+GL, a hydronic loop embedded in the building envelope is directly coupled with a geothermal ground loop, allowing for bidirectional heat exchange between the envelope, the ground, and the indoor environment. A hybrid co-simulation framework was established by coupling a reduced-order resistor–capacitor (RC) thermal network model with EnergyPlus augmented with GHEDesigner modules. The RC model generated feasible heat flux options under three operating modes, and EnergyPlus predicted sensible loads, energy use, and pump energy demand. At each simulation step, a supervisory control algorithm selected the optimal loop configuration and duty factor that maximizes useful TABE geothermal utilization without exceeding the predicted sensible load, thereby avoiding overheating or cooling. Case studies were conducted for Los Angeles, California, Charleston, South Carolina, and Denver, Colorado. Results showed that the proposed framework reduced HVAC electricity consumption by 43%–67%, natural gas use for space heating by 11%–38%, and peak electricity demand by 43%–88%. These results highlight the potential of combining reduced-order envelope modeling, direct geothermal coupling, and load-oriented supervisory control to improve whole building energy performance and reduce peak demand across diverse weather conditions.

Howard, Daniel [Southern Adventist University]↗

An Open-Source Framework for Characterizing Urban Energy Models: Integrating Top-Down and Bottom-Up Methods to Predict Residential Buildings Characteristics: Preprint

Bottom-up urban energy models are crucial for understanding current energy use patterns and informing design strategies. However, accurately characterizing these models to represent different communities remains a challenge due to the extensive data needed for simulating existing energy use behavior. This data includes information related to human activities and building characteristics, all of which correlate with socioeconomic factors. To overcome this challenge, we developed an automated framework that utilizes both top-down and bottom-up data, to predict unknown building and occupant characteristics that are needed for more accurate and equitable modeling and analytics. Our framework, integrated into the URBANopt district energy modeling platform, uses statistical data models from ResStock. URBANopt models co-located buildings and neighborhoods. At this scale there are data gaps in building characteristic data, such as materials, insulation, occupancy, income, and energy usage of the buildings. To address this data gap, we use ResStock data, representative at the census tract scale, and develop machine-learning and deeplearning techniques to disaggregate it to individual buildings. By mapping unique occupant, building and economic properties to URBANopt energy models, we gain detailed insights into the variability of building energy use across different neighborhoods. This insight helps deploy technologies for co-located buildings and supports targeted upgrades for communities with unique economic and demographic characteristics, ensuring energy equity. Accurate characterization of energy models allows us to develop equitable strategies tailored to diverse neighborhoods, whether underserved or affluent. Our automated framework streamlines energy modeling and provides a reliable tool for building energy characterization.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Numerical Investigation of High Delta T Sensible Storage Integrated CO2 Heat Pump: Preprint

To assist building heating electrification, this paper numerically investigates a load flexible heat pump system for commercial buildings. The system consists of a CO2 vapor compression cycle, a sensible thermal storage tank, and an air handling unit. The thermal storage medium is inexpensive, non-toxic and stable anti-freeze solution (30% potassium acetate). The air handing unit has an indoor coil and a ventilation coil. The system can be used to manage building electric load. During peak hours, the heat pump is off and the hot solution water is discharged from the tank to heat up the indoor air and ventilation air. During the hour of charge, the heat pump delivers hot solution water to the tank and to the air. The tank can also stand by while the heat pump provides space heating directly. We selected a medium sized office building located in Minnesota as the representative building and used EnergyPlus to obtain its 24 hour load data. We designed three storage tank volumes assuming 50 degrees C, 65 degrees C and 80 degrees C tank temperatures to independently provide the building load for 4 hours in the morning. The higher the tank temperature, the smaller the required volume, and thus higher energy density. The effective energy density is 78 with an 80 degrees C tank, and 40 kWhth/m3 with 50 degrees C. We simulated the tank integrated heat pump performance subjected to the 24-hour building load profile and ambient data. The baseline is the same system without storage tank. There was a trade-off between the storage energy density and the charging COP. The charge hour COP was 2.77 to charge the tank to 80 degrees C, and 3.01 to 50 degrees C. The proposed system could shift building load from the peak hours (8:00 - 12:00) to off-business hour (23:00 - 7:00+1). It eliminated 100% compressor electricity use during the peak hours, and avoided a peak electric power of 34 kW. The 65 degrees C tank saved 9.5 kWhe (4%) considering all day operation, which was the best balance between energy density and the system operation efficiency among the three options.

CO2 heat pump↗

Building Datasets and Training Methods for ML Based Magnet Quench Detection

Detecting quenches in superconducting (SC) magnets during training is a challenging process that involves capturing physical events that occur at different frequencies and appear as various signal features. These events may be correlated across instrumentation type, thermal cycle, and ramp. These events together build a more complete picture of continuous processes occurring in the magnet, and may allow us to flag potential precursors for quench detection. We present our work on building an automatic machine learning (ML) based quench detection system. We build upon our existing work on unsupervised auto-encoders for acoustic sensors and quench antenna (QA) by first establishing a supervised ML training pipeline. We show the results of an event tagging, analysis, and simulation framework on our QA and acoustic data which are used concurrently to build a training dataset for a supervised implementation. We then show how this supervised training can be used as a prior in a semi-supervised framework and compare this to the unsupervised neural network auto-encoder performance.This allows us to have a more concrete understanding of the performance of our algorithms relative to physical events occurring in the magnet, and also provides a baseline software tool to generically evaluate our quench prediction autoencoders under completely unsupervised, supervised, and semi-supervised training conditions.

Khan, Maira [Fermilab]↗

GridLAB-D Technical Support Document: Residential Equivalent Thermal Parameter Model

GridLAB-D is a power distribution systems simulation and analysis tool developed by Pacific Northwest National Laboratory. Although GridLAB-D and its underlying residential load model has been used in a variety of power systems analyses, comprehensive documentation of the derivation of the residential house model has not been formally published. The purpose of this technical support document is to serve as a comprehensive resource for the thermal dynamics modeling and house definition implemented in GridLAB-D. It covers model derivation, parameter definitions, and implementation steps in the codebase.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Efficient Simulation of Logical Magic State Preparation Protocols

Developing space- and time-efficient logical magic state preparation (MSP) protocols will likely be an essential step toward building a large-scale fault-tolerant quantum computer. Motivated by this need, we introduce a scalable method for simulating logical MSP protocols under the standard circuit-level noise model. When applied to protocols based on code-switching, magic state cultivation, and magic state distillation, our method yields a complexity polynomial in (i) the number of qubits and (ii) the nonstabilizerness, e.g., stabilizer rank or Pauli rank, of the target encoded magic state. The efficiency of our simulation method is rooted in a curious fact: every circuit-level Pauli error in these protocols propagates to a Clifford error at the end. This property is satisfied by a large family of protocols, including those that repeatedly measure a transversal Clifford that squares to a Pauli. We provide a proof-of-principle numerical simulation that prepares a magic state using such logical Clifford measurements. Our work enables practical simulation of logical MSP protocols without resorting to approximations or resource-intensive state-vector simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhancing Building Resilience: Maintaining Energy Efficiency and Thermal Comfort During Power Outages in Cold Climates

The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surrogate Modeling of Landau Damping with Deep Operator Networks

Kinetic simulations excel at capturing microscale plasma physics phenomena with high accuracy, but their computational demands make them impractical for modeling large-scale space and astrophysical systems. In this context, we build a surrogate model, using Deep Operator Networks (DeepONets), based upon the Vlasov–Poisson simulation data to model the dynamical evolution of plasmas, focusing on the Landau damping process—a fundamental kinetic phenomenon in space and astrophysical plasmas. The trained DeepONets are able to capture the evolution of electric field energy in both linear and nonlinear regimes under various conditions. Extensive validation highlights DeepONets’ robust performance in reproducing complex plasma behaviors with high accuracy, paving the way for large-scale modeling of space and astrophysical plasmas.

plasma astrophysics↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗