Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A Consistent EPIC Visible Channel Calibration using VIIRS and MODIS as a Reference

The Earth Polychromatic Imaging Camera (EPIC) aboard the Deep Space Climate Observatory (DSCOVR) satellite constantly images the sunlit disk of Earth from the Lagrange-1 (L1) point in 10 spectral channels spanning the UV, VIS, and NIR spectrums. Recently, the DSCOVR EPIC team has publicly released version 2 dataset, which has implemented improved navigation, stray-light correction, and flat-fielding of the CCD array. The EPIC 2-year data record must be well-calibrated for consistent cloud, aerosol, trace gas, land use and other retrievals. Because EPIC lacks onboard calibrators, the observations made by EPIC channels must be calibrated vicariously using the coincident measurements from radiometrically stable instruments that have onboard calibration systems. MODIS and VIIRS are best-suited instruments for this task as they contain similar spectral bands that are well-calibrated onboard using solar diffusers and lunar tracking. We have previously calibrated the EPIC version 1 dataset by using EPIC and VIIRS angularly matched radiance pairs over both all-sky ocean and deep convective clouds (DCC). We noted that the EPIC image required navigations adjustments, and that the EPIC stray-light correction provided an offset term closer to zero based on the linear regression of the EPIC and VIIRS ray-matched radiance pairs. We will evaluate the EPIC version 2 navigation and stray-light improvements using the same techniques. In addition, we will monitor the EPIC channel calibration over the two years for any temporal degradation or anomalous behavior. These two calibration methods will be further validated using desert and DCC invariant Earth targets. The radiometric characterization of the selected invariant targets is performed using multiple years of MODIS and VIIRS measurements. Results of these studies will be shown at the conference.

Haney, C. O.↗

Calibration of the DUNE Far Detector Using Cosmic-ray Muon Events

The Deep Underground Neutrino Experiment (DUNE) aims to set new limits on parameters associated with neutrino oscillations, neutrino astrophysics, and beyond the Standard Model (SM) searches such as nucleon decay. DUNE will quantify the magnitude of CP violation in the lepton sector, and determine the neutrino mass ordering. These benefit highly from the large target mass and excellent imaging, tracking, and particle identification capabilities of Liquid Argon Time Projection Chambers (LArTPCs). Detector calibration is essential to make precise physics measurements. For instance, accurate energy reconstruction is necessary for measuring many of the aforementioned quantities with the precision required for discovering new physics and fully exploiting the capabilities of the detector. Cosmic muons are a freely available natural source of calorimetric data and can be used for calibrating various detector parameters. This thesis provides an analysis of simulated cosmic-ray muon events generated with the Muon Simulation Underground (MUSUN) generator in the DUNE horizontal drift (HD) far detector (FD). The study focuses on analysing the energy and angular distribution of various classes of muon events, as well as characterising the different particles produced by cosmic muon interactions. The analysis of π0 → 2γ events within the cosmic-ray muon sample is presented in this thesis with a detailed study of reconstructing electromagnetic showers. The π0 mass is reconstructed within the DUNE FD, yielding a value of (136 ± 7) MeV/c2. Additionally, the thesis introduces methods for dE/dx calibration using simulated and reconstructed muon tracks. A calibration constant Ccal = (5.469 ± 0.003) × 10−3 ADC × tick/e is obtained through a model-dependent calibration process, where 1 tick corresponds to 500 ns of sampling time of an ADC. Furthermore, a calibration technique is presented, demonstrating precise translation from dQ/dx to dE/dx. This calibration method is applied to stopping muons, charged pions, and protons in the DUNE FD, addressing the measurement of energy loss in the detector volume. These are important calibrations of the DUNE FD and will contribute to achieving the exciting physics goals of the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvements to the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) Calibration System

As a continuing effort to increase the calibration accuracy of the AVIRIS data a number of recent improvements have been implemented and are in the process of being tested during the 1994 flight season. These include the following innovations: A direct observation of a laboratory radiance standard is now used to double check the wide field-of-view calibration via an integrating sphere source. Launch site field calibration of the AVIRIS sensor is now being planned to augment the laboratory and inflight calibration. Modification to a dry air conditioning unit has been made to enable ground calibration at flight operating temperatures. One hundred lines of dark imagery has been added to the end of each flight line to assist in the analysis and removal of residual coherent noise. The intensity of the onboard calibration lamp has been modified to improve response in the blue end of the spectrum. Novel spectral filters have been installed in the onboard calibration source.

Airborne Visible/Infrared Imaging Spectrometer Cal↗

MODIS and VIIRS Calibration History and Future Outlook

The MODIS is a key instrument for NASA’s EOS program, currently operated onboard the Terra and Aqua spacecraft launched in 1999 and 2002, respectively. The VIIRS is a MODIS follow-on instrument for the JPSS program. Adding to the ones operated onboard the S-NPP and NOAA-20 satellites launched in 2011 and 2017, respectively, three nearly identical VIIRS instruments will also be launched. This will enable the data records from MODIS and VIIRS to be extended beyond 2040. In addition to various applications and scientific studies of the Earth’s system, long-term data records from MODIS and VIIRS observations will greatly benefit the space-based climate observing system. This is attributed to the high-quality measurements and extensive calibration efforts, from pre-launch to post-launch. This paper provides an overview of MODIS and VIIRS calibration history and approaches applied to establish and maintain sensor calibration traceability and accuracy. It illustrates calibration and performance issues through different phases of the mission using examples derived from ground testing equipment, on-board calibrators, and other calibration targets. Moreover, discussed in this paper are outstanding challenges and future efforts to maintain and improve sensor calibration stability and long-term data quality, and to better support the space-based climate observing system.

MODIS↗

Terra MODIS: 20 years of on-orbit calibration and performance

For nearly 20 years, Terra MODIS observations have generated a broad range of data products, enabling the remote sensing community and users worldwide for their studies of many key geophysical parameters of the Earth’s system. MODIS collects data in 36 spectral bands, covering wavelengths from 0.41 to 14.4 μm, that are calibrated by a set of on-board calibrators (OBC). Also contributed to sensor on-orbit calibration and characterization are near monthly-scheduled lunar observations and long-term trends of sensor responses over select ground targets. The quality of MODIS data products relies strongly on the dedicated efforts to the operate instrument, derive and update calibration parameters, and improve calibration strategies and algorithms in order to address on-orbit changes of sensor characteristics and its OBC functions. This paper provides an overview of Terra MODIS on-orbit operation and calibration activities over the last 20 years, including changes made to extend and preserve instrument and OBC functions and their implementation strategies. It illustrates sensor on-orbit performance using data from its OBC, lunar observations, and select ground targets and discusses major changes in sensor characteristics and corrections applied to the L1B algorithms or updates of calibration look-up tables (LUTs). Also described in this paper are lessons learned from Terra MODIS and future efforts to further extend its long-term data records.

Terra↗

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data↗

Bayesian calibration and uncertainty quantification of a rate-dependent cohesive zone model for polymer interfaces

In this work we present a rate-dependent cohesive zone model for the fracture of polymeric interfaces and performs a Bayesian calibration, an uncertainty quantification, and a sensitivity analysis for the model. The proposed cohesive zone model accounts for both reversible elastic and irreversible rate-dependent separation sliding deformation at the interface. The viscous dissipation due to the irreversible opening at the interface is modeled using elastic-viscoplastic kinematics that incorporates the effects of strain rate. Inverse calibration of parameters for such complex models through trial and error is challenging due to the large number of parameters of the model. Moreover, the calibrated parameter values are often non-unique and uncertain when the available experimental data is limited. To tackle this challenge, we employ a Bayesian calibration approach to identify parameters from experimental data, the resulting parameters significantly enhance the accuracy of the model. To quantify the uncertainty associated with the inverse parameter estimation, a modular Bayesian approach is employed to calibrate the unknown model parameters, accounting for the parameter uncertainty of the cohesive zone model. The advantages of the Bayesian calibration over a deterministic parameter fit are demonstrated. Further, to quantify the model uncertainties, such as incorrect assumptions or missing physics, a discrepancy function is introduced, which significantly improves the model’s prediction. Finally, the total uncertainty of the model is quantified in a predictive setting. A sensitivity analysis is performed to assess how changes in the input variables of the model affect the peak load, facilitating the identification of a concise set of highly influential parameters. The present approach can be used for calibration and uncertainty quantification for other complex computational mechanics models. It should also facilitate the designing of interface materials under uncertainty.

42 ENGINEERING↗

A proposed high-intensity radiometer calibration method using concentrated solar radiation

Accurate calibration of irradiance measurement devices, or radiometers, is essential for ensuring the reliability of measurements in high heat applications such as concentrating solar power (CSP), aerospace, defense, and pulsed power systems. Despite the critical need, existing calibration standards and service providers are limited to irradiance levels below 100 kW/m 2 and specific radiation sources, which is insufficient for many applications. For instance, CSP technologies, particularly those under the Department of Energy’s Solar Energy Technologies Office (SETO) Gen 3 program, require accurate measurements of broadband irradiance at levels exceeding 2000 kW/m 2 . In even more extreme scenarios, such as re-entry vehicles, heat levels can surpass 10000 kW/m 2 . Current ISO standards, specifically ISO 14934–2 and ISO 14934–3, are constrained to lower irradiance levels and dependent on black body heat sources, limiting their applicability for high-intensity broadband irradiance measurements, particularly in concentrated solar applications. Here, to address this shortfall, the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL) proposes a calibration method and facility capable of characterizing radiometers up to 2750 kW/m 2 using concentrated solar irradiance. Calibrating with concentrated sunlight is important for solar applications as it aligns the calibration process with the solar spectrum. This alignment is crucial for minimizing systematic errors and avoiding the need for additional corrections that may arise when radiometers designed for solar applications are calibrated using black-body or electrical sources. This paper presents the present day NSTTF characterization facility and procedure, detailing the proposed calibration method and uncertainty quantification. The presented method builds upon 1980′s NSTTF methodology and involves both theoretical and empirical methods to establish a robust relationship between gauge voltage output and irradiance intensity, quantifying both measurement and fitting errors. By addressing the limitations of existing standards and extending the characterization range, this work provides an advancement in the field of high-intensity irradiance measurement and instrumentation characterization.

Gardon gauge↗

Advancements in Constitutive Model Calibration: Leveraging the Power of Full‐Field DIC Measurements and In Situ Load Path Selection for Reliable Parameter Inference

Accurate material characterization and model calibration are essential for computationally supported high-consequence engineering decisions. Historically, characterization and calibration methods (1) use simplified test specimen geometries and global data, (2) cannot guarantee that sufficient characterization data are collected for a specific model of interest, (3) use deterministic methods that provide best-fit parameter values with no uncertainty quantification, and (4) are sequential, inflexible, and time-consuming. This work brings together several recent advancements into an improved workflow called interlaced characterization and calibration (ICC) that advances the state-of-the-art in constitutive model calibration. The ICC paradigm (1) employs tools to efficiently use full-field data to calibrate high-fidelity material models, (2) aligns the data needed with the data collected by adopting an optimal experimental design protocol, (3) quantifies parameter uncertainty through Bayesian inference and (4) incorporates these advancements into a quasi real-time feedback loop. The ICC framework is demonstrated here on the calibration of a material model using simulated full-field data for an aluminium cruciform specimen being deformed biaxially. The cruciform is actively driven through the myopically preferred load path using Bayesian optimal experimental design, which selects load steps that yield the maximum expected information gain (EIG). Principal component analysis (PCA) is performed on the model predictions of full-field displacements, and fast surrogate models are built to approximate the input-output relationships of the expensive finite element model. Furthermore, the tools developed and demonstrated here show that high-fidelity constitutive models can be efficiently and reliably calibrated with quantified uncertainty, thus supporting credible decision-making and potentially increasing the agility of solid mechanics modelling by enabling utilization of computational simulations at earlier stages of the design cycle.

Bayesian optimal experimental design↗

Automatic Calibration and Health Monitoring of Infrastructure Sensors

Smart transportation infrastructure relies on networks of heterogeneous sensors - cameras, radars, and lidars - continuously monitoring traffic conditions. However, executing the initial spatial calibration of multiple sensors and the subsequent health monitoring presents significant operational challenges. Environmental factors, mechanical vibrations, and gradual drift cause spatial misalignment, degrading fusion performance and tracking accuracy. Traditional calibration approaches require manual intervention with specialized targets or survey equipment, resulting in service interruptions and high maintenance costs. This work presents an automated framework for initial calibration and continuous health monitoring without human intervention or service disruption. Our approach addresses two critical problems: (1) detecting when sensors become miscalibrated during operation, and (2) automatically re-establishing spatial alignment using only operational traffic data. The health monitoring component analyzes measurement innovations - differences between sensor observations and predicted object states - to detect systematic biases indicative of calibration drift. By computing bias magnitude, directional consistency, and rejection rates, the system identifies miscalibrations as small as 0.5 meters. Unlike traditional methods requiring known calibration targets, our diagnostic operates continuously on live traffic observations, enabling early detection before fusion quality degrades. The automatic recalibration algorithm leverages overlapping sensor fields-of-view and temporal correlation of vehicle observations. Using graph-based optimization, the system automatically discovers which sensor pairs observe common regions, estimates pairwise spatial transformations using RANSAC-based robust estimation, and jointly optimizes all sensor poses through bundle adjustment. The framework handles practical deployment challenges, including different sensor sampling rates (1-10 Hz), varying installation positions, unknown orientations, and limited overlap regions (>10%). When approximate sensor positions are available from installation surveys (+/-1m accuracy), the algorithm additionally estimates sensor orientations, refining both position and rotation to sub-meter and sub-degree accuracy. We validate the framework on multi-hour traffic datasets from six heterogeneous sensors with sampling rates ranging from 1 Hz to 10 Hz. Results demonstrate successful calibration even with sparse overlap (<20%) and automatic detection of miscalibrations exceeding 0.8 meters. This work enables a "deploy-and-forget" sensor infrastructure that maintains calibration autonomously, reducing maintenance costs while improving tracking accuracy. The techniques generalize beyond transportation to any multi-sensor monitoring application requiring robust spatial alignment, including smart cities, industrial monitoring, and surveillance systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Synthesis of VIIRS Solar and Lunar Calibrations

The NASA VIIRS Ocean Science Team (VOST) has developed two independent calibrations of the SNPP VIIRS moderate resolution reflective solar bands using solar diffuser and lunar observations through June 2013. Fits to the solar calibration time series show mean residuals per band of 0.078-0.10%. There are apparent residual lunar libration correlations in the lunar calibration time series that are not accounted for by the ROLO photometric model of the Moon. Fits to the lunar time series that account for residual librations show mean residuals per band of 0.071-0.17%. Comparison of the solar and lunar time series shows that the relative differences in the two calibrations are 0.12-0.31%. Relative uncertainties in the VIIRS solar and lunar calibration time series are comparable to those achieved for SeaWiFS, Aqua MODIS, and Terra MODIS. Intercomparison of the VIIRS lunar time series with those from SeaWiFS, Aqua MODIS, and Terra MODIS shows that the scatter in the VIIRS lunar observations is consistent with that observed for the heritage instruments. Based on these analyses, the VOST has derived a calibration lookup table for VIIRS ocean color data based on fits to the solar calibration time series.

Calibrations↗

Assessment of New Load Schedules for the Machine Calibration of a Force Balance

New load schedules for the machine calibration of a six-component force balance are currently being developed and evaluated at the NASA Ames Balance Calibration Laboratory. One of the proposed load schedules is discussed in the paper. It has a total of 2082 points that are distributed across 16 load series. Several criteria were applied to define the load schedule. It was decided, for example, to specify the calibration load set in force balance format as this approach greatly simplifies the definition of the lower and upper bounds of the load schedule. In addition, all loads are assumed to be applied in a calibration machine by using the one-factor-at-a-time approach. At first, all single-component loads are applied in six load series. Then, three two-component load series are applied. They consist of the load pairs (N1, N2), (S1, S2), and (RM, AF). Afterwards, four three-component load series are applied. They consist of the combinations (N1, N2, AF), (S1, S2, AF), (N1, N2, RM), and (S1, S2, RM). In the next step, one four-component load series is applied. It is the load combination (N1, N2, S1, S2). Finally, two five-component load series are applied. They are the load combination (N1, N2, S1, S2, AF) and (N1, N2, S1, S2, RM). The maximum difference between loads of two subsequent data points of the load schedule is limited to 33 % of capacity. This constraint helps avoid unwanted load "jumps" in the load schedule that can have a negative impact on the performance of a calibration machine. Only loadings of the single- and two-component load series are loaded to 100 % of capacity. This approach was selected because it keeps the total number of calibration points to a reasonable limit while still allowing for the application of some of the more complex load combinations. Data from two of NASA's force balances is used to illustrate important characteristics of the proposed 2082-point calibration load schedule.

wind tunnel testing↗

SIM-Lite Mission Spectral Calibration Sensitivities and Refinements

SIM-Lite missions will perform astrometry at microarcsecond accuracy using star light interferometry. For typical baselines that are shorter than 10 meters, this requires to measure optical path difference (OPD) accurate to tens of picometers calling for highly accurate calibration. A major challenge is to calibrate the star spectral dependency in fringe measurements -- the spectral calibration. Previously, we have developed a spectral calibration and estimation scheme achieving picometer level accuracy. In this paper, we present the improvements regarding the application of this scheme from sensitivity studies. Data from the SIM Spectral Calibration Development Unit (SCDU) test facility shows that the fringe OPD is very sensitive to pointings of both beams from the two arms of the interferometer. This sensitivity coupled with a systematic pointing error provides a mechanism to explain the bias changes in 2007. Improving system alignment can effectively reduce this sensitivity and thus errors due to pointing errors. Modeling this sensitivity can lead to further improvement in data processing. We then investigate the sensitivity to a model parameter, the bandwidth used in the fringe model, which presents an interesting trade between systematic and random errors. Finally we show the mitigation of calibration errors due to system drifts by interpolating instrument calibrations. These improvements enable us to use SCDU data to demonstrate that SIM-Lite missions can meet the 1pm noise floor requirement for detecting earth-like exoplanets.

wave front aberration↗

Laser Calibration of an Impact Disdrometer

A practical approach to developing an operational low-cost disdrometer hinges on implementing an effective in situ adaptive calibration strategy. This calibration strategy lowers the cost of the device and provides a method to guarantee continued automatic calibration. In previous work, a collocated tipping bucket rain gauge was utilized to provide a calibration signal to the disdrometer's digital signal processing software. Rainfall rate is proportional to the 11/3 moment of the drop size distribution (a 7/2 moment can also be assumed, depending on the choice of terminal velocity relationship). In the previous case, the disdrometer calibration was characterized and weighted to the 11/3 moment of the drop size distribution (DSD). Optical extinction by rainfall is proportional to the 2nd moment of the DSD. Using visible laser light as a means to focus and generate an auxiliary calibration signal, the adaptive calibration processing is significantly improved.

calibration↗

Soil Moisture Active/Passive (SMAP) L-Band Microwave Radiometer Post-Launch Calibration Upgrade

Current performance and existing problems in SMAP radiometer L1B_TB version 3 data product are described. The post-launch calibration algorithm has been updated by calibrating the three calibration parameters (the equivalent noise temperature of the noise diode, the offset of the reference load, and the antenna gain) jointly by using the global ocean and CS with both 110o and 180o pitch maneuvers after the reflector emissivity is calibrated. The results show that both calibration drift during eclipse season and bias over CS are removed. The RMSDs of the calibration drift over both the global ocean and CS are less than 0.1 K, and the goals of the calibration algorithm upgrade are achieved for coming L1B_TB version 4 data release.

Validation↗

The Inter-Calibration of the DSCOVR EPIC Imager 2 with Aqua-MODIS and NPP-VIIRS

The Deep Space Climate Observatory (DSCOVR) Earth Polychromatic Imaging Camera (EPIC) continuously observes the illuminated disk from the Lagrange-1 point. The EPIC sensor was designed to monitor the diurnal variation of ozone, clouds, aerosols, and vegetation, especially those features that benefit from observation near-backscatter conditions. The EPIC sensor does not contain any onboard calibration systems. This study describes the inter-calibration of EPIC channels 5 (0.44 μm), 6 (0.55 μm), 7 (0.68 μm), and 10 (0.78 μm) with respect to Aqua-MODIS and NPP-VIIRS. The calibration is transferred using coincident ray-matched reflectance pairs over all-sky tropical ocean (ATO) and deep convective cloud (DCC) targets. A robust and automated image-alignment technique based on feature matching was formulated to improve the navigation quality of the EPIC images. The EPIC V02 dataset exhibits improved navigation over V01. Because the visible channels display similar spatial features, a single visible channel can be used to co-register the remaining visible bands. The VIIRS-referenced EPIC ATO and DCC ray-matched calibration coefficients are within 0.3%. The EPIC four-year calibration trends based on VIIRS are within 0.15%/year. The MODIS-based EPIC calibration coefficients were compared against the Geogdzhayev and Marshak 2018 published calibration coefficients and are found to be within 1.6%.

DSCOVR↗

Response Versus Scan-Angle Assessment of MODIS Reflective Solar Bands in Collection 6.1 Calibration

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments onboard the Aqua and Terra satellites have been operated for nearly two decades, producing high-quality earth observation data sets suitable for a broad range of scientific studies regarding the earth’s land, ocean, and atmospheric processes. The high radiometric accuracy of MODIS reflective solar band (RSB) calibration has also served as benchmark measurements for on-orbit cross-calibration studies. As the two MODIS instruments have operated well beyond their design lifespan of six years, the measurements from the onboard calibrators alone become inadequate to characterize the sensor’s response at all scan angles, as evinced by long-term drifts observed at certain scan positions of the Aqua-MODIS 0.64- and 0.86-μm bands in Collection 6 (C6) data set. The latest MODIS Level 1B C6.1 data set incorporates earth-view response trending from invariant desert sites as supplemental inputs to characterize the scan-angle calibration dependencies for all RSB. This article presents a deep convective cloud (DCC)-based calibration approach for an independent evaluation of the MODIS RSB response versus scan-angle (RVS) performance in C6.1. The long-term calibration stability and RVS differences in C6.1 have been significantly improved for Aqua-MODIS RSB. The observed RVS differences of more than 2% in Aqua-MODIS C6 bands 1 and 2 have been reduced to within 1% in C6.1. Some RSBs of Terra-MODIS have suffered temporal drifts up to ~2% and calibration shifts up to 3%, particularly around 2016 when the Terra satellite entered into safe mode. The DCC approach has been found very effective in tracking the on-orbit RVS changes over time.

Clouds and the Earth’s Radiant Energy System (CERE↗

NOAA-20 VIIRS Reflective Solar bands on-Orbit Calibration Using a Hybrid Approach

The NOAA-20 Visible Infrared Imaging Radiometer Suite (VIIRS) has been in orbit for more than two and a half years. VIIRS has 22 bands, among which 14 are reflective solar bands (RSBs) covering a spectral range from 0.41 to 2.25 μm. The RSBs are calibrated on-orbit using an onboard solar diffuser (SD), on-orbit degradation of which is tracked by an onboard SD stability monitor (SDSM). NOAA-20 VIIRS is also scheduled to view the Moon approximately monthly and the lunar observations are used to track the RSB on-orbit changes as well. Both SD and lunar calibration results for the RSBs are shown and it is demonstrated that the two sets of the calibration coefficients diverge with time, especially at short wavelengths. The divergence is due to the non-uniformity of the SD degradation, which results in a long-term bias in the calibration coefficients derived from the SD calibration. A hybrid method, which properly combines the SD and lunar calibration results, is applied to generate the RSB calibration coefficients as has been done for SNPP VIIRS RSBs. The hybrid results have both the accuracy and frequency and ensure the high quality of the VIIRS sensor data records (SDR).

Calibration↗