Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Complexity-calibrated benchmarks for machine learning reveal when prediction algorithms succeed and mislead

Abstract Recurrent neural networks are used to forecast time series in finance, climate, language, and from many other domains. Reservoir computers are a particularly easily trainable form of recurrent neural network. Recently, a “next-generation” reservoir computer was introduced in which the memory trace involves only a finite number of previous symbols. We explore the inherent limitations of finite-past memory traces in this intriguing proposal. A lower bound from Fano’s inequality shows that, on highly non-Markovian processes generated by large probabilistic state machines, next-generation reservoir computers with reasonably long memory traces have an error probability that is at least $$\sim 60\%$$ ∼ 60 % higher than the minimal attainable error probability in predicting the next observation. More generally, it appears that popular recurrent neural networks fall far short of optimally predicting such complex processes. These results highlight the need for a new generation of optimized recurrent neural network architectures. Alongside this finding, we present concentration-of-measure results for randomly-generated but complex processes. One conclusion is that large probabilistic state machines—specifically, large $$\epsilon$$ ϵ -machines—are key to generating challenging and structurally-unbiased stimuli for ground-truthing recurrent neural network architectures.

97 MATHEMATICS AND COMPUTING↗

Calibration of a broadband x-ray crystal spectrometer using a continuum x-ray source and photon-counting detectors

We report measurements of sensitivity of a broadband (≃20–30 keV) x-ray crystal spectrometer using a bremsstrahlung continuum x-ray source and several detectors, including an energy-discriminating photon-counting point detector (Si drift diode, Amptek Inc.), imaging hybrid photon-counting detectors (Eiger2-Si and Eiger2-CdTe, DECTRIS Ltd.), and image plates (SR type). Sensitivity is defined as a ratio of the crystal-reflected energy-position-dispersed spectrum measured by a given detector to the incident non-dispersed spectrum measured using the energy-discriminating point detector. The sensitivity derived from data measured exclusively by the point detector is considered detector-independent and serves as a reference. The sensitivities derived from data collected with the hybrid photon-counting detectors were matched to the reference using a scale factor of 1.05. The image plate-derived sensitivities required a scale factor of 1.16 to match the reference. Furthermore, the resulting mismatch in the shapes of all measured scaled sensitivities in the range of the spectrometer was ≲±10%, while the mismatch between the shapes of the sensitivities corresponding to the Si-based detectors was ≲±2.5%.

Crystal optics↗

Identifying environmentally induced calibration changes in cryogenic RF axion detector systems using deep neural networks

The axion is a compelling hypothetical particle that could account for the dark matter in our universe while simultaneously solving the strong CP problem in quantum chromodynamics. The most sensitive axion detection technique demonstrated so far makes use of a high Q cavity immersed in a strong magnetic field, where axions are converted to microwave photons. This is called an axion haloscope and has primarily targeted the 1–10 GHz range. As searches scan up in axion mass, toward the parameter space favored by theoretical predictions, individual cavity sizes decrease in order to achieve higher frequencies. This shrinking cavity volume translates directly to a loss in signal-to-noise, motivating the plan to replace individual cavity detectors with arrays of cavities. When the transition from one to (N) multiple cavities occurs, haloscope searches are anticipated to become much more complicated to operate, requiring N times as many measurements but also the new requirement that N detectors operate in unison, which can be achieved by locking them to a common frequency. To offset this anticipated increase in detector complexity, we aim to develop new tools for diagnosing experiments using neural networks. Current experiments monitor scattering parameters of their receiver for periodically measuring cavity quality factor and coupling. However, off-resonant data remain relatively useless. In this paper, we ask if it is possible that off-resonant information contained in vector network analyzer scans could be used to diagnose equipment failures/anomalies and measure physical conditions (e.g., temperatures and ambient magnetic field). We demonstrate a proof-of-concept that AI techniques can help manage the complexity of an axion haloscope search for operators.

Engel, Andrew W. [Pacific Northwest National Labor↗

Performance and calibration of quark/gluon-jet taggers using 140 fb -1 of pp collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

The identification of jets originating from quarks and gluons, often referred to as quark/gluon tagging, plays an important role in various analyses performed at the Large Hadron Collider, as Standard Model measurements and searches for new particles decaying to quarks often rely on suppressing a large gluon-induced background. This paper describes the measurement of the efficiencies of quark/gluon taggers developed within the ATLAS Collaboration, using $\sqrt{s}$ = 13 TeV proton–proton collision data with an integrated luminosity of 140 fb -1 collected by the ATLAS experiment. Two taggers with high performances in rejecting jets from gluon over jets from quarks are studied: one tagger is based on requirements on the number of inner-detector tracks associated with the jet, and the other combines several jet substructure observables using a boosted decision tree. A method is established to determine the quark/gluon fraction in data, by using quark/gluon-enriched subsamples defined by the jet pseudorapidity. Differences in tagging efficiency between data and simulation are provided for jets with transverse momentum between 500 GeV and 2 TeV and for multiple tagger working points.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration and simulation of ionization signal and electronics noise in the ICARUS liquid argon time projection chamber

The ICARUS liquid argon time projection chamber (LArTPC) neutrino detector has been taking physics data since 2022 as part of the Short-Baseline Neutrino (SBN) Program. This paper details the equalization of the response to charge in the ICARUS time projection chamber (TPC), as well as data-driven tuning of the simulation of ionization charge signals and electronics noise. The equalization procedure removes non-uniformities in the ICARUS TPC response to charge in space and time. This work leverages the copious number of cosmic ray muons available to ICARUS at the surface. The ionization signal shape simulation applies a novel procedure that tunes the simulation to match what is measured in data. The end result of the equalization procedure and simulation tuning allows for a comparison of charge measurements in ICARUS between Monte Carlo simulation and data, showing good performance with minimal residual bias between the two.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark energy survey year 3 results: miscentring calibration and X-ray-richness scaling relations in redMaPPer clusters

ABSTRACT We use Dark Energy Survey Year 3 (DES Y3) clusters with archival XMM–Newton and Chandra X-ray data to assess the centring performance of the redMaPPer cluster finder and to measure key richness observable scaling relations. We find that 10–20 per cent of redMaPPer clusters are miscentred, both when comparing to the X-ray peak position and to the visually identified central cluster galaxy. We find no significant difference in miscentring in bins of low versus high richness or redshift. The dominant reasons for miscentring include masked or missing data and the presence of other bright galaxies in the cluster. For half of the miscentred clusters, the correct central was one of the possible centrals identified by redMaPPer, while for ∼40 per cent of miscentred clusters, the correct central is not a redMaPPer member mostly due to masking. Additionally, we fit scaling relations of X-ray temperature and luminosity with richness. We find a TX–λ scatter of $0.21\pm 0.01$. While the scatter in TX–λ is consistent in redshift bins, we find modestly different slopes, with high-redshift clusters displaying a somewhat shallower relation. Splitting based on richness, we find a marginally larger scatter for our lowest richness bin, 20 < λ < 40. We note that the robustness of the scaling relations at lower richnesses is limited by the unknown selection function, but at λ > 75, we detect nearly all of the clusters falling within existing X-ray pointings. The X-ray properties of detected, serendipitous clusters are generally consistent with those of targeted clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Towards modelling AR Sco: calibration – reproducing high-energy pulsar emission and testing convergence to Aristotelian electrodynamics

In recent years, kinetic simulations have been crucial to further our understanding of pulsar electrodynamics. Yet, due to the large-scale separation between the gyro-period and the stellar rotation period, resolving the particle gyration has been computationally unfeasible for realistic pulsar parameters. The main aim of this work is comparing our gyro-phase-resolved model with a gyro-centric pulsar model, where our model solves the general equations of motion with included radiation reaction using a higher order numerical solver with adaptive time-steps. Specifically, we aim to (i) reproduce a pulsar’s high-energy emission maps, namely one with 10 per cent of the surface B-field strength of Vela, and the spectra produced by an independent gyro-centric pulsar emission model; and (ii) test convergence of these results to the radiation-reaction limit of Aristotelian electrodynamics. (iii) Additionally, we identify the effect that a large $E_{\parallel }$-field has on the trajectories and radiation calculations. We find that we can reproduce the curvature radiation emission maps and spectra well, using 10 per cent field strengths of the Vela pulsar and injecting our particles at a higher altitude in the magnetosphere. Using sufficiently large $E_{\parallel }$-fields, our numeric results converge to the analytic radiation-reaction limit trajectories. Additionally, we illustrate the importance of accounting for the $\mathbf {E}\times \mathbf {B}$-drift in the particle trajectories and radiation calculations, validating the Harding and collaborators’ model approach. Lastly, we found that our model deals very well with the high-radiation-reaction and high-field regimes present in pulsars.

79 ASTRONOMY AND ASTROPHYSICS↗

DayCent MUVP model calibrated for the simulation of bioenergy crops grown on set-aside land in the US

DayCent MUVP version (Methanogenesis, UV litter degradation and Photosynthesis). DAYCENT is the daily time-step version of the CENTURY biogeochemical model (Parton et al., 1994). DAYCENT simulates fluxes of C and N among the atmosphere, vegetation, and soil (Del Grosso et al., 2001a; Parton et al., 1998). Key submodels include soil water content and temperature by layer, plant production and allocation of net primary production (NPP), decomposition of litter and soil organic matter, mineralization of nutrients, N gas emissions from nitrification and denitrification, and CH4 oxidation in non-saturated soils.

biogeochemical model↗

Utilizing 3D Mechanical Earth Models for Calibration and Validation in a Large-Scale Carbon Capture and Storage Project in North Dakota

Conference paper presented at 17th International Conference on Greenhouse Gas Control Technologies (GHGT-17), Calgary, Alberta, Canada, October 20–24, 2024. Three-dimensional (3D) mechanical earth models (MEMs) are pivotal in assessing geological sites for carbon dioxide (CO 2 ) storage and mitigating potential risks associated with storage and injection. The Energy & Environmental Research Center is exploring innovative carbon storage monitoring techniques at a CO 2 storage site near Beulah, North Dakota. These methods aim to provide lower-impact, faster feedback for commercial carbon capture and storage (CCS) projects. The research includes monitoring CO 2 injection using various approaches: 1) an automated, integrated modular monitoring station; 2) time-lapse electromagnetic (EM) field surveys; 3) drone-based surveillance; 4) time-lapse seismic techniques; and 5) advanced wellbore monitoring.

02 PETROLEUM↗

SAIL Radar b1 Data Processing: Corrections, Calibrations, and Processing Report

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility deployed the second ARM Mobile Facility (AMF2) near Crested Butte, Colorado for the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign. The SAIL campaign occurred from September 1, 2021, to June 15 2023. To study the water cycle in the East River Watershed, ARM deployed a vertically pointing Ka-band ARM Zenith radar (KAZR) and a scanning X-band precipitation radar managed by Colorado State University (CSU XPRECIP), as shown in Figure 1.

54 ENVIRONMENTAL SCIENCES↗

Sensitivity calibration of a Carestream HPX-1 image plate scanner

There is a need to measure the sensitivity of the image plate scanners used to scan Z shot data. The Carestream HPX-1 image plate scanner was tested, and its performance was characterized to determine the system sensitivity in terms of signal per incident photon as a function of x-ray energy. A Manson source was used to simultaneously expose an Amptek x-ray multi-channel analyzer and image plates, allowing for a comparison of the counts as a function of energy to the signal recorded on the image plates. NIST-certified radioactive sources were used to assign an absolute sensitivity. Results indicate that the HPX-1 scanner response matches the shape of the modeled response, allowing for absolute scaling using NIST-certified radioisotope sources. The HPX-1 scanner shows a stable response with measurements taken over one week. In contrast, the sensitivity of the DITABIS scanner was characterized using the same approach, but it exhibits changes in its response that varied by more than 50% over the span of 4 days.

42 ENGINEERING↗