Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

6 MV dosimetric characterization of the 160 MLC, the new Siemens multileaf collimator

New technical developments constantly aim at improving the outcome of radiation therapy. With the use of a computer-controlled multileaf collimator (MLC), the quality of the treatment and the efficiency in patient throughput is significantly increased. New MLC designs aim to further enhance the advantages. In this article, we present the first detailed experimental investigation of the new 160 MLC{sup TM}, Siemens Medical Solutions. The assessment included the experimental investigation of typical MLC characteristics such as leakage, tongue-and-groove effect, penumbra, leaf speed, and leaf positioning accuracy with a 6 MV treatment beam. The leakage is remarkably low with an average of 0.37% due to a new design principle of slightly tilted leaves instead of the common tongue-and-groove design. But due to the tilt, the triangular tongue-and-groove effect occurs. Its magnitude of approximately 19% is similar to the dose defect measured for MLCs with the common tongue-and-groove design. The average longitudinal penumbra measured at depth d{sub max}=15 mm with standard 100x100 mm{sup 2} fields is 4.1{+-}0.5 mm for the central range and increases to 4.9{+-}1.3 mm for the entire field range of 400x400 mm{sup 2}. The increase is partly due to the single-focusing design and the large distance between the MLC and the isocenter enabling a large patient clearance. Regarding the leaf speed, different velocity tests were performed. The positions of the moving leaves were continuously recorded with the kilovoltage-imaging panel. The maximum leaf velocities measured were 42.9{+-}0.6 mm/s. In addition, several typical intensity-modulated radiation therapy treatments were performed and the delivery times compared to the Siemens OPTIFOCUS MLC. An average decrease of 11% in delivery time was observed. The experimental results presented in this article indicate that the dosimetric characteristics of the 160 MLC are capable of improving the quality of dose delivery with respect to precision and dose conformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

0.22 THz wideband sheet electron beam traveling wave tube amplifier: Cold test measurements and beam wave interaction analysis

In this paper, we describe micro-fabrication, RF measurements, and particle-in-cell (PIC) simulation modeling analysis of the 0.22 THz double-vane half period staggered traveling wave tube amplifier (TWTA) circuit. The TWTA slow wave structure comprised of two sections separated by two sever ports loaded by loss material, with integrated broadband input/output couplers. The micro-metallic structures were fabricated using nano-CNC milling and diffusion bonded in a three layer process. The 3D optical microscopy and SEM analysis showed that the fabrication error was within 2-3 {mu}m and surface roughness was measured within 30-50 nm. The RF measurements were conducted with an Agilent PNA-X network analyzer employing WR5.1 T/R modules with a frequency range of 178-228 GHz. The in-band insertion loss (S{sub 21}) for both the short section and long section (separated by a sever) was measured as {approx}-5 dB while the return loss was generally around {approx}-15 dB or better. The measurements matched well with the S-matrix simulation analysis that predicted a 3 dB bandwidth of {approx}45 GHz with an operating frequency at 220 GHz. However, the measured S{sub 21} was {approx}3 dB less than the design values, and is attributed to surface roughness and alignment issues. The confirmation measurements were conducted over the full frequency band up to 270 GHz employing a backward wave oscillator (BWO) scalar network analyzer setup employing a BWO in the frequency range 190 GHz-270 GHz. PIC simulations were conducted for the realistic TWT output power performance analysis with incorporation of corner radius of 127 {mu}m, which is inevitably induced by nano-machining. Furthermore, the S{sub 21} value in both sections of the TWT structure was reduced to correspond to the measurements by using a degraded conductivity of 10% International Annealed Copper Standard. At 220 GHz, for an elliptic sheet electron beam of 20 kV and 0.25 A, the average output power of the tube was predicted to be reduced from 90 W (for ideal conductivity/design S-parameters) to 70 W (for the measured S-parameters/inferred conductivity) for an average input power of 50 mW. The gain of the tube remains reasonable: {approx}31.4 dB with an electronic efficiency of {approx}1.4%. The same analysis was also conducted for several frequencies between 190 GHz-260 GHz. This detailed realistic PIC analysis demonstrated that this nano-machined TWT circuit has slightly reduced S-parameters and output power from design, but within an acceptable range and still have promising output power, gain, and band width as required. Thus, we expect to meet the specifications of 1000 W-GHz for the darpa program goals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-P-29: Testing Display Monitors for GSDF Compliance - a Practical Approach

Purpose: To develop a simple technique for testing display monitors for compliance with the DICOM Grayscale Standard Display Function (GSDF), in accordance with the recommendations of AAPM Task Group 18. Methods: We have developed a spreadsheet that can be used to compare both the luminance response and contrast response of a display to the GSDF, using luminance measurements of the SMPTE test pattern. The contrast response compares the slope of the GSDF j-index as a function of pixel value to that of the GSDF function, and should lie within the range 0.85 to 1.15. Results: We present the results of measurements both of primary diagnostic displays and of ultrasound and acquisition workstations, all at a tertiary care hospital. The Barco displays in the radiographic reading rooms are GSDF compliant or nearly so, while those in the ultrasound reading rooms and at the acquisition workstations generally show significantly higher contrast at low luminance levels than they would if GSDF compliant, and lower contrast at high luminance levels. Conclusion: The spreadsheet that we developed allows a simple comparison of measured display contrast response to the GSDF. Although we used the SMPTE pattern, the same technique could be used with other grayscale patterns, such as TG18-QC and TG18-PQC.

07 ISOTOPE AND RADIATION SOURCES↗

The American Board of Radiology perspective on maintenance of certification: Part IV: Practice quality improvement in radiologic physics

Recent initiatives of the American Board of Medical Specialties (ABMS) in the area of maintenance of certification (MOC) have been reflective of the response of the medical community to address public concerns regarding quality of care, medical error reduction, and patient safety. In March 2000, the 24 member boards of the ABMS representing all medical subspecialties in the USA agreed to initiate specialty-specific maintenance of certification (MOC) programs. The American Board of Radiology (ABR) MOC program for diagnostic radiology, radiation oncology, and radiologic physics has been developed, approved by the ABMS, and initiated with full implementation for all three disciplines beginning in 2007. The overriding objective of MOC is to improve the quality of health care through diplomate-initiated learning and quality improvement. The four component parts to the MOC process are: Part I: Professional standing, Part II: Evidence of life long learning and periodic self-assessment, Part III: Cognitive expertise, and Part IV: Evaluation of performance in practice (with the latter being the focus of this paper). The key components of Part IV require a physicist-based response to demonstrate commitment to practice quality improvement (PQI) and progress in continuing individual competence in practice. Diplomates of radiologic physics must select a project to be completed over the ten-year cycle that potentially can improve the quality of the diplomate's individual or systems practice and enhance the quality of care. Five categories have been created from which an individual radiologic physics diplomate can select one required PQI project: (1) Safety for patients, employees, and the public, (2) accuracy of analyses and calculations, (3) report turnaround time and communication issues, (4) practice guidelines and technical standards, and (5) surveys (including peer review of self-assessment reports). Each diplomate may select a project appropriate for an individual, participate in a project within a clinical department, participate in a peer review of a self-assessment report, or choose a qualified national project sponsored by a society. Once a project has been selected, the steps are: (1) Collect baseline data relevant to the chosen project, (2) review and analyze the data, (3) create and implement an improvement plan, (4) remeasure and track, and (5) report participation to the ABR, using the template provided by the ABR. These steps begin in Year 2, following training in Year 1. Specific examples of individual PQI projects for each of the three disciplines of radiologic physics are provided. Now, through the MOC programs, the relationship between the radiologic physicist and the ABR will be continuous through the diplomate's professional career. The ABR is committed to providing an effective infrastructure that will promote and assist the process of continuing professional development including the enhancement of practice quality improvement for radiologic physicists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Absolute spectral radiance responsivity calibration of sun photometers

Sun photometers are designed to measure direct solar irradiance and diffused sky radiance for the purpose of atmospheric parameters characterization. A sun photometer is usually calibrated by using a lamp-illuminated integrating sphere source for its band-averaged radiance responsivity, which normally has an uncertainty of 3%-5% at present. Considering the calibration coefficients may also change with time, a regular high precision calibration is important to maintain data quality. In this paper, a tunable-laser-based facility for spectral radiance responsivity calibration has been developed at the Key Laboratory of Optical Calibration and Characterization, Chinese Academy of Sciences. A reference standard radiance radiometer, calibrated against cryogenic radiometer, is used to determine the radiance from a laser-illuminated integrating sphere source. Spectral radiance responsivity of CIMEL CE318-2 sun photometer is calibrated using this new calibration system with a combined standard uncertainty of about 0.8%. As a validation, the derived band-averaged radiance responsivity are compared to that from a Goddard Space Flight Center lamp-based sphere calibration and good agreements (difference <1.4%) are found from 675 to 1020 nm bands.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-601: Output Factor Calculation of Irregular Shape Electron Cutout at Extended SSD

Purpose: To calculate the output factor of irregular shape electron beam at extended SSD using modified lateral build-up-ratio method. Methods: Circular cutouts from 2.0cm diameter to maximum possible sizes were prepared for applicator cone size of 15×15cm. In addition, different irregular cutouts were prepared. Percentage depth dose (PDD) curves were measured for each cutout using 6, 9, 12 and 16-MeV at the standard SSD of 100cm. The scanning was done using Multidata system and Scanditronix diodes on 2100SC Varian LINAC. In addition, for each cutout and electron beam energy doses were measured at SSD values of 100, 105, 110, 115cm using EDR2 films and diodes. Results: The measured PDD were normalized to the depth of 1.0mm. The lateral build-up-ratio (LBR) and the lateral scatter parameter (sigma) were calculated for each circular cutout using the open 15X15-cm2 field as the reference field. Taking the linear increase of sigma with cutout size into account, PDD of the irregular cutouts were calculated at 100 cm SSD. Furthermore, using the dose measured at different SSDs, the effective SSD value for each circular cutout and electron beam energy was determined. Employing the LBR and the effective-SSD values of the circular cutouts along with the calculated PDD of the irregular cutouts, the output factors of the irregular cutout at different extended SSD values were calculated. Finally, the calculated output factors were compared with the measured values. Conclusion: In this research, it is shown that output factor of irregular shape electron beam at extended SSD can be determined by using the LBR and the effective SSD values of circular cutouts. The percentage difference of the calculated output factor from the measured output factor for irregular cutouts at extended SSD were within 3.0%.

07 ISOTOPE AND RADIATION SOURCES↗

Use of XRF to characterize pre-Hanford orchards in the 100-OL-1 operable unit - 15717

Prior to 1943, Hanford site included several small towns with approximately 5,000 acres of orchards; at the time lead arsenate (PbHAsO{sub 4}) was the most commonly used pesticide. High concentration of lead and arsenic have been recorded where trees and stumps are still visible. Pre-Hanford orchards have been designated as 100-OL-1 Operable Unit. An Optimization study evaluated optimal counting time and position of the XRF from soils collected at the site. A Pilot Study included the evaluation of a field portable x-ray fluorescence (XRF) analyzer determining if performance results meet quality assurance criteria for cleanup. XRF has only previously been used as a screening tool. Four Decision Units (DUs) are to be analyzed: Ol-14. OL-32. OL-IU6-4 and OL-FR2-1. The DUs vary in size and have had distinct historic activities; such as 46.4 acres OL-14 having a military camp in the 1950's unlike OL-FR2-1 having been disturbed as it is near the F area reactor. Together the DUs provide an adequate representation of the Operable Unit. Screening criteria for lead (250 mg/kg) and arsenic (20 mg/kg). Six samples were collected ranging above, at, and below the screening criteria of 250 mg/kg for Pb and 20 mg/kg for As at the Decision Units OL-14 and OL-IU6-4, and labeled respectively. Samples were hand sieved, homogenized and placed in sample cups. Three replicates were prepared for each sample. Each sample cup was analyzed 3 times for 30 sec. A Standard Reference Material (SRM) was analyzed after every 20 readings. Three samples were selected for 15, 30, 45, 60, 90, 120, 150 and 180 second fixed and variable analysis. Two transects at OL-14, and one at OL-IU6-4 were created by selecting locations 90. around ground zero at distances of 0.5, 1, 2, 4, 8 and 12 feet (16 ft for OL-14). Locations were scanned in triplicate for 60 seconds each. 4 Decision Units spanning roughly 370 acres were chosen to represent 100-OL-1 Operable Unit. 40 locations within each DU were selected using Visual Sample Plan (VSP) with a random start and systematic grid pattern. Each location would be analyzed with 3 replicates and a 60 second count time. The Standard Reference Material (SRM) and blank are analyzed after every 20 counts to ensure accuracy. Data is extracted from XRF to be implemented in GIS for visual representation of site with 1943 and 2013 aerial imagery. Discussion/Conclusion: - XRF provided a good indication of precision and accuracy relative to ICP with a linear correlation R{sup 2} value higher than anticipated at .9735; - MDL proved the detection limit is significantly lower than the screening criteria; - When comparing results from the first 40 locations of OL-14 to the total 80 locations of OL-14, the same variability was seen; - We expect high concentrations of Pb and As to be where past orchards are present though this does not occur as all sites. Significance: - XRF is competent for decision making as values fall within ±20% ICP data; - The highest concentrations are not where expected, which may be an issue for sites outside of Hanford that have had more development; - The size of the DU does not affect the number of samples measured. Future Work: - Verification and validation of the XRF Data (QA/QC); - Revise conceptual site model; - Statistical evaluations to investigate: Estimation of variability in surface soils, appropriate size for DU, and sample size per DU; - Coordinating sample results through CORE; - Displaying sample results in PHOENIX (GIS tool)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-D-9A-02: Relative Effects of Threshold Choice and Spatial Resolution Modeling On SUV and Volume Quantification in F18-FDG PET Imaging of Anal Cancer Patients

Purpose: PET imaging with F18-FDG is utilized for treatment planning, treatment assessment, and prognosis. A region of interest (ROI) encompassing the tumor may be determined on the PET image, often by a threshold T on the PET standard uptake values (SUVs). Several studies have shown prognostic value for relevant ROI properties including maximum SUV value (SUVmax), metabolic tumor volume (MTV), and total glycolytic activity (TGA). The choice of threshold T may affect mean SUV value (SUVmean), MTV, and TGA. Recently spatial resolution modeling (SRM) has been introduced on many PET systems. SRM may also affect these ROI properties. The purpose of this work is to investigate the relative influence of SRM and threshold choice T on SUVmean, MTV, TGA, and SUVmax. Methods: For 9 anal cancer patients, 18F-FDG PET scans were performed prior to treatment. PET images were reconstructed by 2 iterations of Ordered Subsets Expectation Maximization (OSEM), with and without SRM. ROI contours were generated by 5 different SUV threshold values T: 2.5, 3.0, 30%, 40%, and 50% of SUVmax. Paired-samples t tests were used to compare SUVmean, MTV, and TGA (a) for SRM on versus off and (b) between each pair of threshold values T. SUVmax was also compared for SRM on versus off. Results: For almost all (57/60) comparisons of 2 different threshold values, SUVmean, MTV, and TGA showed statistically significant variation. For comparison of SRM on versus off, there were no statistically significant changes in SUVmax and TGA, but there were statistically significant changes in MTV for T=2.5 and T=3.0 and in SUVmean for all T. Conclusion: The near-universal statistical significance of threshold choice T suggests that, regarding harmonization across sites, threshold choice may be a greater concern than choice of SRM. However, broader study is warranted, e.g. other iterations of OSEM should be considered.

60 APPLIED LIFE SCIENCES↗

THE ACS SURVEY OF GLOBULAR CLUSTERS. XIII. PHOTOMETRIC CALIBRATION IN COMPARISON WITH STETSON STANDARDS

In this study we compare the photometric data of 34 Milky Way globular clusters, observed within the Advanced Camera for Surveys (ACS) Treasury Program (PI: A. Sarajedini) with the corresponding ground-based data, provided by the Photometric Standard Field Catalogs of Stetson. We focus on the transformation between the Hubble Space Telescope/ACS F606W to V-band and F814W to I-band only. The goal is to assess the validity of the filter transformation equations by Sirianni et al. with respect to their dependence on metallicity, horizontal branch morphology, mass, and integrated (V – I) color of the various globular clusters. The transformation equations as recommended by Sirianni et al. are based on synthetic photometry, were mostly tested on NGC 2419, and may introduce additional uncertainties when applied to different stellar populations. Such a dependence is expected due to the fact that the transformation equations are based on the observations of only one globular cluster, i.e., NGC 2419. Surprisingly, the correlation between offset and metallicity is found to be weak, with a low level significance. The correlation between offset and horizontal branch structure, as well as total cluster mass is still weaker. Based on the available data we do not find the photometric offset to be linked to multiple stellar populations, e.g., as found in NGC 0288, NGC 1851, and NGC 5139. The results of this study show that there are small systematic offsets between the transformed ACS- and observed ground-based photometry, and that these are only weakly correlated, if at all, with various cluster parameters and their underlying stellar populations. As a result, investigators wishing to transform globular cluster photometry from the Sirianni et al. ground-based V, I system onto the Stetson system simply need to add –0.040 (±0.012) to the V magnitudes and –0.047 (±0.011) to the I magnitudes. This in turn means that the transformed ACS V – I colors match the ground-based values from Stetson to within ∼0.01 mag.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-BRD-15: Quality Correction Factors in Scanned Or Broad Proton Therapy Beams Are Indistinguishable

Purpose: The IAEA TRS-398 code of practice details the reference conditions for reference dosimetry of proton beams using ionization chambers and the required beam quality correction factors (kQ). Pencil beam scanning (PBS) requires multiple spots to reproduce the reference conditions. The objective is to demonstrate, using Monte Carlo (MC) calculations, that kQ factors for broad beams can be used for scanned beams under the same reference conditions with no significant additional uncertainty. We consider hereafter the general Alfonso formalism (Alfonso et al, 2008) for non-standard beam. Methods: To approach the reference conditions and the associated dose distributions, PBS must combine many pencil beams with range modulation and shaping techniques different than those used in passive systems (broad beams). This might lead to a different energy spectrum at the measurement point. In order to evaluate the impact of these differences on kQ factors, ion chamber responses are computed with MC (Geant4 9.6) in a dedicated scanned pencil beam (Q-pcsr) producing a 10×10cm2 composite field with a flat dose distribution from 10 to 16 cm depth. Ion chamber responses are also computed by MC in a broad beam with quality Q-ds (double scattering). The dose distribution of Q -pcsr matches the dose distribution of Q-ds. k-(Q-pcsr,Q-ds) is computed for a 2×2×0.2cm{sup 3} idealized air cavity and a realistic plane-parallel ion chamber (IC). Results: Under reference conditions, quality correction factors for a scanned composite field versus a broad beam are the same for air cavity dose response, k-(Q-pcsr,Q-ds) =1.001±0.001 and for a Roos IC, k-(Q-pcsr,Q-ds) =0.999±0.005. Conclusion: Quality correction factors for ion chamber response in scanned and broad proton therapy beams are identical under reference conditions within the calculation uncertainties. The results indicate that quality correction factors published in IAEA TRS-398 can be used for scanned beams in the SOBP of a high-energy proton beam. Jefferson Sorriaux is financed by the Walloon Region under the convention 1217662. Jefferson Sorriaux is sponsored by a public-private partnership IBA - Walloon Region.

60 APPLIED LIFE SCIENCES↗

Combined Effort to De-Inventory the New Brunswick Laboratory of Plutonium Certified Reference Materials - 20504

To de-inventory plutonium Certified Reference Materials standards (CRMs) from the New Brunswick National Laboratory (NBL), the Argonne National Laboratory (ANL) and Savannah River National Laboratory (SRNL) formed a unique team. This teaming arrangement leveraged the different capabilities and expertise of both laboratories, helping to ensure the effort would be performed both safely and cost-effectively. With the NBL then physically housed on the ANL site, ANL served as the host-site, providing the necessary facilities and support services (e.g., supplying everything from hoods, loading equipment, and scales to Health Physics supports). From a packaging perspective, ANL's responsibilities focused mainly on characterizing and preparing the contents for shipment, followed by performing the Shipper of Record activities. With SRNL being the Package Design Authority of the 9978, the Type B packaging used for this effort, SRNL's scope included developing a Safety Analysis Report in Packaging (SARP) Letter Amendment to add the CRMs as authorized contents to the 9978. Recognizing competency, ANL prodigiously tasked SRNL to perform the actual loading of the CRMs into the 9978s, while physically on the ANL site. This paper details five different aspects of this effort. They are: 1. Characterization/validation of the CRM contents. 2. Development of the 9978 SARP Letter Amendment for the content change. 3. Development of the nitrogen inerting method to address SARP identified potential flammability concerns. 4. Renewal of the SRNL 9978 loading procedure. 5. Performance of the actual work execution activities. In 2017, the first nine packages were successfully loaded and shipped from NBL, while in 2019, the last ten were successfully loaded and planned for shipment. Without ANL leveraging SRNL's strengths, the de-inventorying of NBL of its plutonium CRMs would have likely taken many years longer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Size Exclusion Chromatography-Ion Mobility-Mass Spectrometry Coupling: a Step Toward Structural Biology

Noncovalent interactions are essential for the structural organization of biomacromolecules in cells. For this reason, the study of the biophysical, dynamic, and architectural interactions among biomacromolecules is essential. Since mass spectrometry requires compatible solutions while preserving the noncovalent bonding network, we envisioned that size exclusion chromatography coupled with ion mobility and mass spectrometry would be a valuable technique to desalt the initial sample and provide solution and gas-phase structural information in a single stage experiment. Such coupling allowed obtaining information on solution protein complex composition with SEC separation and on authenticity and purity with IMS-MS. Our study demonstrated that such coupling is compatible, useful, as well as suitable for a routine analysis, in pharmaceutical industry, for example. Mobility data were reliable and injected standards allowed calibrating the collision cross-section scale. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Resolution Mass Spectrometry Quantification: Impact of Differences in Data Processing of Centroid and Continuum Data

High-resolution mass spectrometry (HRMS) in full scan mode acquires all ions present in the sample of interest offering a lot of qualitative information. This, in combination with the improved performance of the new generation HRMS systems, triggers more (bio) analysts to switch from triple quad MS systems to HRMS for quantitative analysis. Quantitative processing of HRMS data is performed based on narrow mass extraction windows rather than on nominal mass product ion chromatograms (SRM or MRM). Optimal processing of HRMS data requires different considerations and software tools and can have an impact on data processing and final results. The selection of centroid versus continuum/profile data for processing, selection of the optimal narrow mass extraction window, using theoretical versus measured accurate mass for the extraction of the ion chromatograms as well as differences in calculations and data handling residing in the different vendor software packages are tackled in the presented manuscript. These differences are illustrated on HRMS data acquired for the same plasma samples on three different platforms, i.e., a Sciex QToF, a Waters QToF, and a Thermo Orbitrap system, and processed in four different software packages, i.e., Sciex Analyst® TF, Waters Masslynx, Waters Unifi, and Thermo Xcalibur. The impact of these differences on quantitative HRMS performance was evaluated on calibration curves of eight small molecule compounds in plasma using four different ways of processing. Simple guidelines are provided for the selection of an optimal mass extraction window for continuum and centroided data. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Murine Mueller cells are progenitor cells for neuronal cells and fibrous tissue cells

Mammalian Mueller cells have been reported to possess retinal progenitor cell properties and generate new neurons after injury. This study investigates murine Mueller cells under in vitro conditions for their capability of dedifferentiation into retinal progenitor cells. Mueller cells were isolated from mouse retina, and proliferating cells were expanded in serum-containing medium. For dedifferentiation, the cultured cells were transferred to serum-replacement medium (SRM) at different points in time after their isolation. Interestingly, early cell passages produced fibrous tissue in which extracellular matrix proteins and connective tissue markers were differentially expressed. In contrast, aged Mueller cell cultures formed neurospheres in SRM that are characteristic for neuronal progenitor cells. These neurospheres differentiated into neuron-like cells after cultivation on laminin/ornithine cell culture substrate. Here, we report for the first time that murine Mueller cells can be progenitors for both, fibrous tissue cells and neuronal cells, depending on the age of the cell culture.

60 APPLIED LIFE SCIENCES↗

Measurement of (5'R)- and (5'S)-8,5'-cyclo-2'-deoxyadenosines in DNA in vivo by liquid chromatography/isotope-dilution tandem mass spectrometry

Oxidatively induced DNA lesions (5'R)- and (5'S)-8,5'-cyclo-2'-deoxyadenosines (R-cdA and S-cdA) are detectable and accumulate in vivo due to disease states and defects in DNA repair. They block transcription and inhibit gene expression, and may play a role in disease processes. Accurate measurement of these lesions in DNA in vivo is necessary to understand their biological effects. We report on a methodology using liquid chromatography/isotope-dilution tandem mass spectrometry to measure R-cdA and S-cdA in DNA. This methodology permitted the detection of these compounds at a level of 0.1 fmol on-column. Levels of R-cdA and S-cdA in mouse liver DNA amounted to 0.133 {+-} 0.024 and 0.498 {+-} 0.065 molecules/10{sup 7} DNA 2'-deoxynucleosides, respectively. The successful measurement of R-cdA and S-cdA in DNA in vivo suggests that this methodology will be used for understanding of their repair and biological consequences, and that these compounds may be used as putative biomarkers for disease states.

60 APPLIED LIFE SCIENCES↗

Lead, mercury, and cadmium exposure and attention deficit hyperactivity disorder in children

Background: There is limited research examining the relationship between lead (Pb) exposure and medically diagnosed attention deficit hyperactivity disorder (ADHD) in children. The role of mercury (Hg) and cadmium (Cd) exposures in ADHD development is even less clear. Objectives: To examine the relationship between Pb, Hg, and Cd and ADHD in children living inside and outside a Lead Investigation Area (LIA) of a former lead refinery in Omaha, NE. Methods: We carried out a case-control study with 71 currently medically diagnosed ADHD cases and 58 controls from a psychiatric clinic and a pediatric clinic inside and outside of the LIA. The participants were matched on age group (5–8, 9–12 years), sex, race (African American or Caucasians and others), and location (inside or outside LIA). We measured whole blood Pb, total Hg, and Cd using inductively coupled plasma mass spectrometry. Results: Inside the LIA, the 27 cases had blood Pb geometric mean (GM) 1.89 µg/dL and the 41 controls had 1.51 µg/dL. Outside the LIA, the 44 cases had blood Pb GM 1.02 µg/dL while the 17 controls had 0.97 µg/dL. After adjustment for matching variables and maternal smoking, socioeconomic status, and environmental tobacco exposure, each natural log unit blood Pb had an odds ratio of 2.52 with 95% confidence interval of 1.07–5.92. Stratification by the LIA indicated similar point estimate but wider CIs. No associations were observed for Hg or Cd. Conclusions: Postnatal Pb exposure may be associated with higher risk of clinical ADHD, but not the postnatal exposure to Hg or Cd. -- Highlights: • Blood Pb levels are associated with ADHD diagnosis in children. • No association was found between blood Cd or Hg levels and ADHD. • Children living close to hazardous waste site need to reduce metal exposure.

60 APPLIED LIFE SCIENCES↗

Thermal conductivity measurement using modulated photothermal radiometry for nitrate and chloride molten salts

Molten salts are being used or explored for thermal energy storage and conversion systems in concentrating solar power and nuclear power plants. Thermal conductivity of molten salts is an important thermophysical property dictating the performance and cost of these systems, but its accurate measurement has been challenging, as evidenced by wide scattering of existing data in literature. The corrosive and conducting nature of these fluids also leads to time consuming sample preparation processes of many contact-based measurements. Here, in this work, we report the measurement of thermal conductivity of molten salts using a modulated photothermal radiometry (MPR) technique, which is a laser-based, non-contact, frequency-domain method adopted for molten salts for the first time. By unitizing the advantages of front side sensing of frequency-domain measurements and the vertical holder orientation, the technique can minimize the natural convection and salt creeping effects, thus yielding accurate molten salt thermal conductivity . The MPR technique is first calibrated using standard molten materials including paraffin wax and sulfur. It is then applied on measuring pure nitrate salts (NaNO 3 and KNO 3 ), solar salt (NaNO 3 –KNO 3 mixture), and chloride salt (NaCl–KCl–MgCl 2 ). The measurement results are compared with data from literature, especially those obtained from laser flash analysis (LFA). Our results demonstrate that the MPR is a convenient and reliable technique of measuring thermal conductivity of molten salts. Accurate thermal conductivity data of molten salts will be valuable in developing the next-generation high-temperature thermal energy storage and conversion systems.

14 SOLAR ENERGY↗

Oriented SrFe{sub 12}O{sub 19} thin films prepared by chemical solution deposition

Thin films of SrFe{sub 12}O{sub 19} (SrM) were prepared from a solution of iron and strontium alkoxides through the chemical solution deposition method on both amorphous (glassy SiO{sub 2}), and single crystal substrates (Si(100), Si(111), Ag(111), Al{sub 2}O{sub 3}(001), MgO(111), MgAl{sub 2}O{sub 4}(111), SrTiO{sub 3}(111)) substrates. The process of crystallization was investigated by means of powder diffraction, atomic force microscopy and scanning electron microscopy. Magnetization measurements, ferromagnetic and nuclear magnetic resonance were used for evaluation of anisotropy in the films. Whilst amorphous substrates enabled growth of randomly oriented SrM phase, use of single crystal substrates resulted in samples with different degree of oriented growth. The most pronounced oriented growth was observed on SrTiO{sub 3}(111). A detailed inspection revealed that growth of SrM phase starts through the breakup of initially continuous film into isolated grains with expressive shape anisotropy and hexagonal habit. A continuous film with epitaxial relations to the substrate was produced by repeating recoating and annealing. - Graphical Abstract: XRD and AFM patterns of SrFe{sub 12}O{sub 19} thin film epitaxially grown on SrTiO{sub 3}(111) single crystal using seeding layer templating. Highlights: > Single phase SrFe{sub 12}O{sub 19} thin films prepared by chemical solution deposition. > Epitaxial growth on SrTiO{sub 3}(111) with (00l)SrM//(111)SrTiO{sub 3}, <110>SrM//<110>SrTiO{sub 3}). > Seed layer breaks into isolated single crystal islands and serves as a template. > Larger seed grains grow by consuming the grains within the bulk of recoated film.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗