Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

DarkNESS: A skipper-CCD nanosatellite for dark matter searches

The Dark matter Nanosatellite Equipped with Skipper Sensors (DarkNESS) deploys a recently developed skipper-CCD architecture with sub-electron readout noise in low Earth orbit (LEO) to investigate potential signatures of dark matter (DM). The mission addresses two interaction channels: electron recoils from strongly interacting sub-GeV DM and X-rays produced through decaying DM. Orbital observations avoid attenuation that limits ground-based measurements, extending sensitivity reach for both channels. The mission proceeds toward launch following laboratory validation of the instrument. A launch opportunity has been secured through Firefly Aerospace’s DREAM 2.0 program, awarded to the University of Illinois Urbana-Champaign (UIUC). As a result, this will constitute the first use of skipper-CCDs in space and evaluate their suitability for low-noise X-ray and single-photon detection in future space observatories.

Alpine, Phoenix [University of Illinois, Urbana-Ch↗

Two-dimensional burn velocity and analysis of burn products of nitromethane at high pressure

We have studied the laser-initiated deflagration of nitromethane (CH 3 NO 2 ) under high static pressure in the diamond anvil cell. Time-resolved images of the deflagrations have been obtained using intensified CCDs (ICCD). In contrast with previous work, we rely on spontaneous emission from the reaction, rather than changes in the speckle pattern produced by artificial illumination of the sample. Furthermore, as opposed to the 1D records obtained previously with streak cameras, ICCDs permit imaging of the burn in two dimensions providing the ability to directly observe anisotropic deflagration behavior. Here, we report several examples of this behavior and discuss its possible origins. We have also investigated the products of the reaction using Raman spectroscopy. At pressures below 25 GPa, the burn product is observed to be opaque and has a Raman spectrum consistent with a carbonaceous soot. At pressures above 25 GPa, the burn product is observed to be transparent (consistent with earlier reports) and its Raman spectrum reveals the presence of molecular N 2 and a nitrogen-carbonate species. The latter species can be recovered to ambient pressure and has a Raman spectrum consistent with ammonium carbonate or ammonium bicarbonate. To aid interpretation of the Raman spectra, measurements have also been made on the isotopologues CH 3 15 NO 2 and 13 CH 3 NO 2 . This work establishes the importance of advanced time-resolved imaging to reveal the details of deflagration under high pressure and further advances our understanding of the corresponding chemistry.

Deflagration↗

Identifying Patients Who Are Unsuitable for Accelerated Partial Breast Irradiation Using Three-dimensional External Beam Conformal Techniques

Purpose: Several recent studies reported that severe late toxicities including soft-tissue fibrosis and fat necrosis are present in patients treated with accelerated partial breast irradiation (APBI) and that these toxicities are associated with the large volume of tissue targeted by high-dose irradiation. The present study was performed to clarify which patients are unsuitable for APBI to avoid late severe toxicities. Methods and Materials: Study subjects comprised 50 consecutive patients with Stage 0-II unilateral breast cancer who underwent breast-conserving surgery, and in whom five or six surgical clips were placed during surgery. All patients were subsequently replanned using three-dimensional conformal radiotherapy (3D-CRT) APBI techniques according to the National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39 and Radiation Therapy Oncology Group (RTOG) 0413 protocol. The beam arrangements included mainly noncoplanar four- or five-field beams using 6-MV photons alone. Results: Dose-volume histogram (DVH) constraints for normal tissues according to the NSABP/RTOG protocol were satisfied in 39 patients (78%). Multivariate analysis revealed that only long craniocaudal clip distance (CCD) was correlated with nonoptimal DVH constraints (p = 0.02), but that pathological T stage, anteroposterior clip distance (APD), site of ipsilateral breast (IB) (right/left), location of the tumor (medial/lateral), and IB reference volume were not. DVH constraints were satisfied in 20% of patients with a long CCD ({>=}5.5 cm) and 92% of those with a short CCD (p < 0.0001). Median IB reference volume receiving {>=}50% of the prescribed dose (IB-V{sub 50}) of all patients was 49.0% (range, 31.4-68.6). Multivariate analysis revealed that only a long CCD was correlated with large IB-V{sub 50} (p < 0.0001), but other factors were not. Conclusion: Patients with long CCDs ({>=}5.5 cm) might be unsuitable for 3D-CRT APBI because of nonoptimal DVH constraints and large IB-V{sub 50}.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transfer of microstructure pattern of CNTs onto flexible substrate using hot press technique for sensing applications

Graphical abstract: - Highlights: • Successfully transfer of microstructure patterned CNTs on PET substrate. • Demonstrate as resistor-based NH{sub 3} gas sensor in the sub-ppm range. • Excellent photodetector having instantaneous response and recovery characteristics. • An effective technique to grow and produce flexible electronic device. - Abstract: In this work, we report the successful and efficient transfer process of two- dimensional (2-D) vertically aligned carbon nanotubes (CNTs) onto polyethylene terephthalate (PET) substrate by hot pressing method with an aim to develop flexible sensor devices. Carbon nanotubes are synthesized by cold wall thermal chemical vapor deposition using patterned SiO{sub 2} substrate under low pressure. The height of the pattern of CNTs is controlled by reaction time. The entire growth and transfer process is carried out within 30 min. Strong adhesion between the nanotube and polyethylene terephthalate substrate was observed in the post-transferred case. Raman spectroscopy and scanning electron microscope (SEM) studies are used to analyze the microstructure of carbon nanotube film before and after hot pressing. This technique shows great potential for the fabrication of flexible sensing devices. We report for the first time, the application of patterned microstructure developed by this technique in the development of gas sensor and optoelectronic device. Surface resistive mode is used for detection of ammonia (NH{sub 3}) gas in the sub-ppm range. An impressive photoconducting response is also observed in the visible wavelength. The reproducibility of the sample was checked and the results indicate the possibility of use of carbon nanotube as gas sensor, photodetector, CCDs etc.

36 MATERIALS SCIENCE↗

Balmer emission measurements in JET-ILW hydrogen, deuterium, tritium and deuterium-tritium low-confinement mode plasmas

Measurements of Balmer-alpha (B-α) and Balmer-gamma (B-γ), where B = H, D, or T isotopes of hydrogen, emission across the low-field side (LFS) divertor in JET ITER-like Wall (ILW), low-confinement mode (L-mode) plasma indicate that the divertor plasma was more strongly detached in deuterium, tritium and deuterium–tritium than in hydrogen plasmas. These measurements are consistent with the lower degree of detachment in hydrogen versus tritium plasmas inferred from Langmuir probes (Groth et al., 2023). The ratio of B-γ to B-α is a suitable indicator of high density/low temperature conditions because B-α emission is dominated by electron impact excitation with a small electron–ion recombination component regardless of electron temperature and density (for conditions in tokamak plasmas) whilst for B-γ the recombination component increases and the excitation component decreases as the electron temperature decreases and the electron density increases. Within the uncertainty of the measurements, the electron density at the low-field side separatrix and the power crossing the separatrix are similar to permit these comparisons. The B-©/B-α ratio is well correlated with the onset of detachment as measured by Langmuir probes (McCracken et al., 1998; Groth et al., 2023). The ratios of B-γ and B-α varied between 0.005 and 0.035 for low-recycling, high-recycling and partially detached conditions, and were 60–70 % higher in partially detached hydrogen than in tritium plasmas. In contrast, the difference between deuterium, tritium and 40–60 % deuterium–tritium is within 10 % and thus within the uncertainties of the measurements. Profiles of the B-α and B-γ emission was measured with two filtered CCDs connected to the visible lost light leg of JET’s mirror link spectroscopy system (Meigs et al., 2010; Lomanowski et al., 2014). Spatially (radial) narrower B-α profiles were measured with increasing isotope mass, while similarly broadened B-γ profiles were measured.

Balmer↗

DAMIC at SNOLAB

We introduce the fully-depleted charge-coupled device (CCD) as a particle detector. We demonstrate its low energy threshold operation, capable of detecting ionizing energy depositions in a single pixel down to 50 eV ee . We present results of energy calibrations from 0.3 keV ee to 60 ke Vee , showing that the CCD is a fully active detector with uniform energy response throughout the silicon target, good resolution (Fano ~0.16), and remarkable linear response to electron energy depositions. We show the capability of the CCD to localize the depth of particle interactions within the silicon target. We discuss the mode of operation and unique imaging capabilities of the CCD, and how they may be exploited to characterize and suppress backgrounds. We present the first results from the deployment of 250 μm thick CCDs in SNOLAB, a prototype for the upcoming DAMIC100. DAMIC100 will have a target mass of 0.1 kg and should be able to directly test the CDMS-Si signal within a year of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute contrast estimation for soft X-ray photon fluctuation spectroscopy using a variational droplet model

Abstract X-ray photon fluctuation spectroscopy using a two-pulse mode at the Linac Coherent Light Source has great potential for the study of quantum fluctuations in materials as it allows for exploration of low-energy physics. However, the complexity of the data analysis and interpretation still prevent recovering real-time results during an experiment, and can even complicate post-analysis processes. This is particularly true for high-spatial resolution applications using CCDs with small pixels, which can decrease the photon mapping accuracy resulting from the large electron cloud generation at the detector. Droplet algorithms endeavor to restore accurate photon maps, but the results can be altered by their hyper-parameters. We present numerical modeling tools through extensive simulations that mimic previous x-ray photon fluctuation spectroscopy experiments. By modification of a fast droplet algorithm, our results demonstrate how to optimize the precise parameters that lift the intrinsic counting degeneracy impeding accuracy in extracting the speckle contrast. These results allow for an absolute determination of the summed contrast from multi-pulse x-ray speckle diffraction, the modus operandi by which the correlation time for spontaneous fluctuations can be measured.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatial Resolution Versus Data Acquisition Efficiency in Mapping an Inhomogeneous System with Species Diffusion

Traditionally, spatially-resolved photoluminescence (PL) has been performed using a point-by-point scan mode with both excitation and detection occurring at the same spatial location. But with the availability of high quality detector arrays like CCDs, an imaging mode has become popular for performing spatially-resolved PL. By illuminating the entire area of interest and collecting the data simultaneously from all spatial locations, the measurement efficiency can be greatly improved. However, this new approach has proceeded under the implicit assumption of comparable spatial resolution. We show here that when carrier diffusion is present, the spatial resolution can actually differ substantially between the two modes, with the less efficient scan mode being far superior. We apply both techniques in investigation of defects in a GaAs epilayer – where isolated singlet and doublet dislocations can be identified. A superposition principle is developed for solving the diffusion equation to extract the intrinsic carrier diffusion length, which can be applied to a system with arbitrarily distributed defects. The understanding derived from this work is significant for a broad range of problems in physics and beyond (for instance biology) – whenever the dynamics of generation, diffusion, and annihilation of species can be probed with either measurement mode.

14 SOLAR ENERGY↗

Image Accumulation in Pixel Detector Gated by Late External Trigger Signal and its Application in Imaging Activation Analysis

Single quantum counting pixel detectors of Medipix type are starting to be used in various radiographic applications. Compared to standard devices for digital imaging (such as CCDs or CMOS sensors) they present significant advantages: direct conversion of radiation to electric signal, energy sensitivity, noiseless image integration, unlimited dynamic range, absolute linearity. In this article we describe usage of the pixel device TimePix for image accumulation gated by late trigger signal. Demonstration of the technique is given on imaging coincidence instrumental neutron activation analysis (Imaging CINAA). This method allows one to determine concentration and distribution of certain preselected element in an inspected sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fast, direct x-ray detection charge-coupled device

A charge-coupled device (CCD) capable of 200 Mpixels/s readout has been designed and fabricated on thick, high-resistivity silicon. The CCDs, up to 600 {mu}m thick, are fully depleted, ensuring good infrared to x-ray detection efficiency, together with a small point spread function. High readout speed, with good analog performance, is obtained by the use of a large number of parallel output ports. A set of companion 16-channel custom readout integrated circuits, capable of 15 bits of dynamic range, is used to read out the CCD. A gate array-controlled back end data acquisition system frames and transfers images, as well as provides the CCD clocks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Use Of Full-Field XRF For Simultaneous Elemental Mapping

The characteristics of a Full-Field X-ray Fluorescence (FF-XRF) set-up for element-specific imaging, installed at the HASYLAB synchrotron radiation source, were determined. A lateral resolution of 10 {mu}m and limits of detection in the percentage range were found. Further potential developments in CCDs available for FF-XRF are discussed and the use of polycapillary lenses as image transfer optics is illustrated in some explorative experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The development of a cryogenic over-pressure pump

A cryogenic over-pressure pump (OPP) was tested in the prototype telescope liquid nitrogen (LN2) cooling system for the Dark Energy Survey (DES) Project. This OPP consists of a process cylinder (PC), gas generator, and solenoid operated valves (SOVs). It is a positive displacement pump that provided intermittent liquid nitrogen (LN2) flow to an array of charge couple devices (CCDs) for the prototype Dark Energy Camera (DECam). In theory, a heater submerged in liquid would generate the drive gas in a closed loop cooling system. The drive gas would be injected into the PC to displace that liquid volume. However, due to limitations of the prototype closed loop nitrogen system (CCD cooling system) for DECam, a quasiclosed-loop nitrogen system was created. During the test of the OPP, the CCD array was cooled to its designed set point temperature of 173K. It was maintained at that temperature via electrical heaters. The performance of the OPP was captured in pressure, temperature, and flow rate in the CCD LN2 cooling system at Fermi National Accelerator Laboratory (FNAL)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lunar occultation observation of μ Sgr: A progress report

Lunar Occultation (LO) is an event where limb of the Moon passing over a particular heavenly bodies such as stars, asteroids, or planets. In other words, during the event, stars, asteroids and planets are occulted by the Moon. When occulted objects contact the lunar limb, there will be a diffraction fringe(s) which can be measured photometrically, until the signal vanishes into noise. This event will give us a valuable information about binarities (of stars) and/or angular diameters estimation (of stars, planets, asteroids) in milliarcsecond resolution, by fitting with theoretical LO pattern. CCDs are common for LO observation because of its fast read out, and recently are developed for sub-meter class telescope. In this paper, our LO observation attempt of μ Sgr and its progress report are presented. The observation was conducted on July 30{sup th}, 2012 at Bosscha Observatory, Indonesia, using 45cm f/12 GOTO telescope combined with ST-9 XE CCD camera and Bessel B filter. We used drift-scan method to obtain light curve of the star as it was disappearing behind Moon's dark limb. Our goal is to detect binarity (or multiplicity) of this particular object.

79 ASTRONOMY AND ASTROPHYSICS↗

Absolute calibration of a charge-coupled device camera with twin beams

We report on the absolute calibration of a Charge-Coupled Device (CCD) camera by exploiting quantum correlation. This method exploits a certain number of spatial pairwise quantum correlated modes produced by spontaneous parametric-down-conversion. We develop a measurement model accounting for all the uncertainty contributions, and we reach the relative uncertainty of 0.3% in low photon flux regime. This represents a significant step forward for the characterization of (scientific) CCDs used in mesoscopic light regime.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Highly multiplexible thermal kinetic inductance detectors for x-ray imaging spectroscopy

For X-ray imaging spectroscopy, high spatial resolution over a large field of view is often as important as high energy resolution, but current X-ray detectors do not provide both in the same device. Thermal Kinetic Inductance Detectors (TKIDs) are being developed as they offer a feasible way to combine the energy resolution of transition edge sensors with pixel counts approaching CCDs and thus promise significant improvements for many X-ray spectroscopy applications. TKIDs are a variation of Microwave Kinetic Inductance Detectors (MKIDs) and share their multiplexibility: working MKID arrays with 2024 pixels have recently been demonstrated and much bigger arrays are under development. In this work, we present a TKID prototype, which is able to achieve an energy resolution of 75 eV at 5.9 keV, even though its general design still has to be optimized. We further describe TKID fabrication, characterization, multiplexing, and working principle and demonstrate the necessity of a data fitting algorithm in order to extract photon energies. With further design optimizations, we expect to be able to improve our TKID energy resolution to less than 10 eV at 5.9 keV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ePix100 camera: Use and applications at LCLS

The ePix100 x-ray camera is a new system designed and built at SLAC for experiments at the Linac Coherent Light Source (LCLS). The camera is the first member of a family of detectors built around a single hardware and software platform, supporting a variety of front-end chips. With a readout speed of 120 Hz, matching the LCLS repetition rate, a noise lower than 80 e-rms and pixels of 50 µm × 50 µm, this camera offers a viable alternative to fast readout, direct conversion, scientific CCDs in imaging mode. The detector, designed for applications such as X-ray Photon Correlation Spectroscopy (XPCS) and wavelength dispersive X-ray Emission Spectroscopy (XES) in the energy range from 2 to 10 keV and above, comprises up to 0.5 Mpixels in a very compact form factor. In this paper, we report the performance of the camera during its first use at LCLS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray backlighter requirements for refraction-based electron density diagnostics through Talbot-Lau deflectometry

We report that Talbot-Lau x-ray interferometers can map electron density gradients in High Energy Density (HED) samples. In the deflectometer configuration, it can provide refraction, attenuation, elemental composition, and scatter information from a single image. X-ray backlighters in Talbot-Lau deflectometry must meet specific requirements regarding source size and x-ray spectra, amongst others, to accurately diagnose a wide range of HED experiments. 8 keV sources produced in the high-power laser and pulsed power environment were evaluated as x-ray backlighters for Talbot-Lau x-ray deflectometry. In high-power laser experiments, K-shell emission was produced by irradiating copper targets (500 × 500 × 12.5 μm 3 foils, 20 μm diameter wire, and >10 μm diameter spheres) with 30 J, 8-30 ps laser pulses and a 25 μm copper wire with a 60 J, 10 ps laser pulse. In the pulsed power environment, single (2 × 40 μm) and double (4 × 25 μm) copper x-pinches were driven at ~1 kA/ns. Lastly, moiré fringe formation was demonstrated for all x-ray sources explored, and detector performance was evaluated for x-ray films, x-ray CCDs, and imaging plates in context of spatial resolution, x-ray emission, and fringe contrast.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Key Residues for Catalytic Function and Metal Coordination in a Carotenoid Cleavage Dioxygenase

Carotenoid cleavage dioxygenases (CCDs) are non-heme iron-containing enzymes found in all domains of life that generate biologically important apocarotenoids. Prior studies have revealed a critical role for a conserved 4-His motif in forming the CCD iron center. By contrast, the roles of other active site residues in catalytic function, including maintenance of the stringent regio- and stereo-selective cleavage activity, typically exhibited by these enzymes have not been thoroughly investigated. Here, we examined the functional and structural importance of active site residues in an apocarotenoid-cleaving oxygenase (ACO) from Synechocystis. Most active site substitutions variably lowered maximal catalytic activity without markedly affecting the K m value for the all-trans-8'-apocarotenol substrate. Native C15-C15' cleavage activity was retained in all ACO variants examined suggesting that multiple active site residues contribute to the enzyme's regioselectivity. Crystallographic analysis of a nearly inactive W149A-substituted ACO revealed marked disruption of the active site structure, including loss of iron coordination by His-238 apparently from an altered conformation of the conserved second sphere Glu-150 residue. Gln- and Asp-150-substituted versions of ACO further confirmed the structural/functional requirement for a Glu side chain at this position, which is homologous to Glu-148 in RPE65, a site in which substitution to Asp has been associated with loss of enzymatic function in Leber congenital amaurosis. The novel links shown here between ACO active site structure and catalytic activity could be broadly applicable to other CCD members and provide insights into the molecular pathogenesis of vision loss associated with an RPE65 point mutation.

59 BASIC BIOLOGICAL SCIENCES↗