Search NASA⌕ Search

SEARCH · Search NASA

Results for “CEBAF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Medium Modification of the Light Vector Mesons in Nuclei

Theoretical calculations predict the modification of properties of vector mesons, such as a shift in their masses and/or broadening of their widths in dense nuclear matter. These effects can be related to partial restoration of chiral symmetry at high density or temperature. Photoproduction of vector mesons off nuclei were performed at Jefferson Lab using the CEBAF Large Acceptance Spectrometer (CLAS). The data were taken with a beam of tagged photons with energies up to 4 GeV on various nuclear targets. The properties of the rho vector mesons were investigated via their rare leptonic decay to e+e?. This decay channel is preferred over hadronic modes in order to eliminate final state interactions in the nuclear matter. The combinatorial background in the mass spectrum was removed by a self-normalizing mixed-event technique. The rho meson mass distributions were extracted for each of the targets. Statistically significant results regarding medium modification of the rho meson in the nuc

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thomas Jefferson National Accelerator Facility

The Thomas Jefferson National Accelerator Facility (Jefferson Lab) in Newport News, Virginia, USA, is one of ten national laboratories under the aegis of the Office of Science of the U.S. Department of Energy (DOE). It is managed and operated by Jefferson Science Associates, LLC. The primary facility at Jefferson Lab is the Continuous Electron Beam Accelerator Facility (CEBAF) as shown in an aerial photograph in Figure 1. Jefferson Lab was created in 1984 as CEBAF and started operations for physics in 1995. The accelerator uses superconducting radio-frequency (srf) techniques to generate high-quality beams of electrons with high-intensity, well-controlled polarization. The technology has enabled ancillary facilities to be created. The CEBAF facility is used by an international user community of more than 1200 physicists for a program of exploration and study of nuclear, hadronic matter, the strong interaction and quantum chromodynamics. Additionally, the exceptional quality of the beams facilitates studies of the fundamental symmetries of nature, which complement those of atomic physics on the one hand and of high-energy particle physics on the other. The facility is in the midst of a project to double the energy of the facility and to enhance and expand its experimental facilities. Studies are also pursued with a Free-Electron Laser produced by an energy-recovering linear accelerator.

43 PARTICLE ACCELERATORS↗

Summary Report for the C50 Cryomodule Project

The Thomas Jefferson National Accelerator Facility has recently completed the C50 cryomodule refurbishment project. The goal of this project was to enable robust 6 GeV, 5 pass operation of the Continuous Electron Beam Accelerator Facility (CEBAF). The scope of the project included removal, refurbishment and reinstallation of ten CEBAF cryomodules at a rate of three per year. The refurbishment process included reprocessing of SRF cavities to eliminate field emission and to increase the nominal gradient from the original 5 MV/m to 12.5 MV/m. New 'dogleg' couplers were installed between the cavity and helium vessel flanges to intercept secondary electrons that produce arcing in the fundamental Power Coupler (FPC). Other changes included new ceramic RF windows for the air to vacuum interface of the FPC and improvements to the mechanical tuner. Damaged or worn components were replaced as well. All ten of the refurbished cryomodules are now installed in CEBAF and are currently operational. This paper will summarize the performance of the cryomodules.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

12 GeV Upgrade Project - Cryomodule Production

The Thomas Jefferson National Accelerator Facility (Jefferson Lab) is producing ten 100+MV SRF cryomodules (C100) as part of the CEBAF 12 GeV Upgrade Project. Once installed, these cryomodules will become part of an integrated accelerator system upgrade that will result in doubling the energy of the CEBAF machine from 6 to 12 GeV. This paper will present a complete overview of the C100 cryomodule production process. The C100 cryomodule was designed to have the major components procured from private industry and assembled together at Jefferson Lab. In addition to measuring the integrated component performance, the performance of the individual components is verified prior to being released for production and assembly into a cryomodule. Following a comprehensive cold acceptance test of all subsystems, the completed C100 cryomodules are installed and commissioned in the CEBAF machine in preparation of accelerator operations. This overview of the cryomodule production process will include all principal performance measurements, acceptance criterion and up to date status of current activities.

43 PARTICLE ACCELERATORS↗

A low-voltage retarding-field Mott polarimeter for photocathode characterization

Nuclear physics experiments at Thomas Jefferson National Accelerator Facility's CEBAF rely on high polarization electron beams. We describe a recently commissioned system for prequalifying and studying photocathodes for CEBAF with a load-locked, low-voltage polarized electron source coupled to a compact retarding-field Mott polarimeter. The polarimeter uses simplified electrode structures and operates from 5 to 30 kV. The effective Sherman function for this device has been calibrated by comparison with the CEBAF 5 MeV Mott polarimeter. For elastic scattering from a thick gold target at 20 keV, the effective Sherman function is 0.201(5). Its maximum efficiency at 20 keV, defined as the detected count rate divided by the incident particle current, is 5.4(2)×10 -4 , yielding a figure-of-merit, or analyzing power squared times efficiency, of 1.0(1)×10 -5 . The operating parameters of this new polarimeter design are compared to previously published data for other compact Mott polarimeters of the retarding-field type.

43 PARTICLE ACCELERATORS↗

Nb3Sn multicell cavity coating at JLAB

Following encouraging results with Nb3Sn-coated R&D cavities, the existing coating system was upgraded to allow for Nb3Sn coating of CEBAF accelerator cavities. The upgrade was designed to allow Nb3Sn coating of original CEBAF 5-cell cavities with the vapor diffusion technique. Several CEBAF cavities were coated in the upgraded system to investigate vapor diffusion coatings on extended structures. Witness samples coated along with the cavities were characterized with material science techniques, while coated cavities were measured at 4 and 2 K. The progress, lessons learned, and the pathforward are discussed.

Pudasaini, Uttar↗

Positron beams at Ce+BAF

Positron beams would provide a new and meaningful probe for the experimental program at the Thomas Jefferson National Accelerator Facility (JLab). The JLab Positron Working Group, formed in 2018 and now with over 250 members from 75 institutions, continues to develop an experimental program with high duty-cycle positron beams including but not limited to future hadronic physics and dark matter experiments. Critical requirements involve generating positron beams with a high degree of spin polarization, sufficient intensity and a continuous-wave (CW) bunch train compatible with acceleration to 12 GeV at the Continuous Electron Beam Accelerator Facility (CEBAF). In this presentation we describe a start-to-end layout for positron beams at 12 GeV CEBAF utilizing the Low Energy Research Facility (LERF) at Jefferson Lab to build two new injectors. A GaAs dc high voltage photo-gun first generates >1 mA of polarized electrons which are then accelerated to 80-150 MeV and directed to a high-power spinning W target for polarized bremsstrahlung and positron pair creation. A second injector then collects, bunches and accelerates the positrons to 123 MeV. The positron beams are transported by a new beam line and injected into the CEBAF acceptance for acceleration to the end stations with energies up to 12 GeV. The layout is optimized to provide Users with positron spin polarization >60% and intensity greater than >100 nA, and with higher intensities when polarization is not required.

Benesch, J.↗

CHARACTERIZATION OF RADIATION DAMAGES TO POSITRON SOURCE MATERIALS

The secondary beam production target at future positron sources at the Continuous Electron Beam Accelerator Facility (CEBAF), the International Linear Collider (ILC) or the Future Circular Collider (FCC), features unprecedented mechanical and thermal stresses which may compromise sustainable and reliable operation. Candidate materials are required to possess high melting temperature together with excellent thermal conductivity, elasticity and radiation hardness properties. In order to substantiate the material choice for the CEBAF and ILC positron sources, the response of candidate materials such as titanium alloys, tungsten, and tantalum to electron beam irradiation was experimentally investigated. CEBAF and ILC expected operating conditions were mimicked using the 3.5 MeV electron beam of the MAMI facility injector. The material degradations were precisely analyzed via high energy X-ray diffraction at the HEMS beamline operated by the Helmholtz-Zentrum Hereon at the PETRA III synchrotron facility. This work reports the results of these measurements and their interpretation.

Lengler, T.↗

Positrons for Our Future

JLab Users want beams of polarized (and unpolarized) positrons, with beam qualities and modes of operation similar to those provided in the electron beams at CEBAF today [Gra19]. The creation of positrons with a high degree of spin polarization is however very challenging – limited to beta decay, self-polarization in rings, or via e+/e- pair-production, a process requiring a source of polarized gamma rays. At JLab we have a unique source of polarized gamma rays – the bremsstrahlung radiation produced when the spin polarized electron beams of CEBAF interacts with matter – called Polarized Electrons for Polarized Positrons (or PEPPo) [Abb04]. This project sought to extend the PEPPo concept by exploring a possible layout and parameter space for a polarized positron injector at CEBAF based on this approach.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nucleon and Nuclear Structure Studies in Electroproduction with the CLAS Detector at Jefferson Lab

A diverse program for studying the structure of nucleons and nuclei is underway using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab. A wealth of data has been obtained in inclusive, semi-inclusive, and exclusive electroproduction reactions using a variety of unpolarized and polarized beams and targets. The results include studies of excited nucleon states, measurements of nucleon, proton and neutron Form Factors (FFs), Parton Distribution Functions (PDFs), Transverse Momentum Distributions (TMDs), and Generalized Parton Distributions (GPDs), as well as Short Range Correlations (SRCs) in nuclei and Color Transparency phenomena. Jefferson Lab's electron accelerator, CEBAF, doubled its energy to 12~GeV and the upgrade of the experimental equipment is near completion in the experimental halls. The upgraded CLAS detector, CLAS12, enables execution of a broader physics program, with the main focus on uncovering the TMDs and GPDs using semi-inclusive and exclusive reactions in a new kinematic domain. In this talk, an overview of the CLAS electroproduction measurements with 6~GeV CEBAF and prospects of nucleon and nuclear structure studies with the 12~GeV machine and the CLAS12 detector will be discussed.

Stepanyan, Stepan↗

Overview of the SIDIS/TMD program at Jefferson Lab

The study of the single-hadron semi-inclusive deep inelastic scattering process (SIDIS) is a rapidly developing and expanding area of inquiry in hadronic physics, owing to the prospect of realizing a precision three-dimensional imaging of the quark structure of the nucleon in momentum space. Measurements of the azimuthal angular distributions of hadrons produced at large values of z = Eh=? and "small" transverse momentum pT ~ \Lambda_?QCD in deep inelastic lepton-nucleon scattering provides access to novel features of nucleon structure that are inaccessible in traditional inclusive DIS, including the e?ects of initial-state quark transverse momentum, transverse polarization of the parent nucleon and the struck quark, and "flavor tagging" due to the varying sensitivity of di?erent hadron species to di?fferent quark flavors. The Continuous Electron Beam Accelerator Facility (CEBAF) at Je?erson Lab has recently completed an upgrade to a maximum beam energy of 11 GeV at ?ve passes for electron scattering experiments. The energy upgrade of CEBAF, combined with its already unrivaled intensity, duty cycle and polarization, facilitates a three-dimensional nucleon imaging program of unprecedented precision in the valence region. In this talk,I will present a brief overview of the planned CEBAF SIDIS program in experimental Halls A, B and C.

Puckett, Andrew↗

Development of Large Area µRWELL Detectors for CLAS12 High Luminosity Upgrade at Jefferson Lab

The high-luminosity upgrade of the CEBAF Large Acceptance Spectrometer (CLAS12) will significantly enhance the physics reach of experiments in Hall B at JLab. However, at the current luminosity of L = 1 × 1035 cm-2 s-1, the reconstruction efficiency of charged particles in the forward region of the CEBAF Large Acceptance Spectrometer (CLAS12) is at the level of 85% and limited in part by the drift chambers inability to handle high occupancy, in the first tracking region (DC-R1) of the Forward Detector. The reconstruction efficiency is expected to drop even lower at higher luminosities with the current tracking technology. Various options under consideration to achieve the desired performance at a higher luminosity of L = 2 × 1035 cm-2 s-1 include the addition of fast tracking layers to complement DC-R1 or the replacement of DC-R1 with a different tracking detector technology altogether. In either case, a novel generation of compact, simple and robust Micro-Pattern Gaseous Detector (MPGD) known as the Resistive Micro-Well detector (µRWELL) is the ideal candidate to satisfy the requirements in terms of timing O (10 ns) and position O (100 µm) resolutions. A large µRWELL prototype, combined with a two-dimensional U-V strip readout layer based on the novel concept of capacitive-sharing approach has been developed as a proof of principle for fast tracking capabilities in the forward region of CLAS12 high-luminosity upgrade. In this talk, we will present the technical aspects of the design choices of the large µRWELL prototype under development and report on the detector assembly process and preliminary performance characteristic tests. We will also discuss the plans for the test and characterization of the prototype in beam during spring 2023 CEBAF run. Finally, we will report on ongoing R&D efforts on small prototypes with the goal to improve rate capability, spatial resolution performance and minimize material thickness.

Gnanvo, Kondo↗

Polarized positrons at Ce\(^+\)BAF

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab [1]. This concept is based on positron beam generation by a high current polarized electron beam (1 mA, 120 MeV, >85% polarization) irradiating a 4 mm thick rotating water-cooled tungsten target or liquid metal target. The update on the development of the Ce+BAF injector concept including the polarized electron source, the development of high power targets, simulations of positron capture, the design of the transport line from the positron injector to the CEBAF North Linac and the planned experiment to measure the upper limits of transverse and longitudinal emittances accepted by the 12 GeV CEBAF optics are presented. [1] J. Grames et al., "Positron beams at Ce+BAF", in Proc. 14th Int. Particle Accelerator Conf. (IPAC’23), Venice, Italy, MOPL152, pp. 896–899 (2023). doi:10.18429/JACoW-IPAC2023-MOPL152

Ushakov, Andriy↗

Recirculating Beam Breakup Study for the 12 GeV Upgrade at Jefferson Lab

Two new high gradient C100 cryomodules with a total of 16 new cavities were installed at the end of the CEBAF south linac during the 2011 summer shutdown as part of the 12-GeV upgrade project at Jefferson Lab. We surveyed the higher order modes (HOMs) of these cavities in the Jefferson Lab cryomodule test facility and CEBAF tunnel. We then studied recirculating beam breakup (BBU) in November 2011 to evaluate CEBAF low energy performance, measure transport optics, and evaluate BBU thresholds due to these HOMs. This paper discusses the experiment setup, cavity measurements, machine setup, optics measurements, and lower bounds on BBU thresholds by new cryomodules.

43 PARTICLE ACCELERATORS↗

The JLab TMD Program at 6 GeV and 11 GeV

The precise mapping of the nucleon’s transverse momentum dependent parton distributions (TMDs) in the valence quark region has emerged as one of the flagship physics programs of the recently upgraded Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab (JLab). The TMDs describe the three-dimensional, spin-correlated densities of quarks and gluons in the nucleon in momentum space, and are accessible experimentally through detailed studies of the Semi-Inclusive Deep Inelastic Scattering (SIDIS) process, N ( e ; e 0 h ) X . The already unrivaled intensity, polarization and duty factor performance of CEBAF will combine with the dramatic expansion of its kinematic reach embodied by the recent near-doubling of the maximum beam energy to enable the first fully differential precision measurements of SIDIS structure functions in the valence region. In this paper, I will review the existing and forthcoming SIDIS results from the 6 GeV era of CEBAF operations and present an overview of the planned JLab SIDIS program at 11 GeV beam energy

Puckett, Andrew J.↗

SRF Challenges for Improving Operational Electron Linacs

The performance of the operational SRF-based electron linacs CEBAF, ELBE, and S-DALINAC continues to evolve positively. These facilities are exploiting opportunities to improve operational capability by both remediation of past limitations and also construction of new capacity using state-of-the-art designs and processes. A project to rework the weakest ten cryomodules in CEBAF was completed and enabled robust operation for physics at 6 GeV. The 12 GeV Upgrade of CEBAF is now underway and involves construction of ten new CW >100 MV cryomodules with 80 new 7-cell low-loss cell shaped fine-grained niobium cavities, all electropolished. The technical challenges associated with the preparation of these cavities will be reviewed and their performance in both individual acceptance testing and cryomodule testing to date will be summarized. The ELBE facility at Helmhotz Zentrum Dresden Rossendorf continues to develop its source with an SRF gun system. The long-running S-DALINAC at Technische Universität Darmstadt is operating reliably and is evolving in the direction of reduced energy spread and use of polarized electrons for nuclear physics and astrophysics research. *Authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177.

Reece, Charles↗

OVERVIEW AND STATUS OF THE 12 GeV CRYOGENIC SYSTEM UPGRADE AT JLAB

As part of the planned Jefferson Laboratory's electron accelerator (CEBAF) power upgrade, ten additional superconducting RF cryomodules will be added to its accelerator linacs. Although physically the same size as each of the original 40 linac cryomodules, each new cryomodule will have approximately 4 times the acceleration power. To support the additional cryomodule heat loads generated, the existing 2 K, 4600 W Central Helium Liquefier (CHL) plant capacity will be doubled to a total of 9200 W at 2 K plus 24,000 W at 35 K for shield loads. The specified base line process cycle has been modeled after the laboratory's 'Ganni Helium Cycle' process technology. In addition, a fourth physics experimental 'Hall D' will be constructed which will have an additional stand alone 200 W at 4 K helium cryogenic plant. In October of 2008, Jefferson Laboratory (JLab) received approval for project 'Critical Decision 3' construction phase status from the US Department of Energy. An overview of the planned cryogenic systems and current design baseline as it relates to operations will be presented.

42 ENGINEERING↗

Measuring the 2{gamma} Exchange Effect in Electron-Proton Scattering at CLAS

Recent results from experiments at Jefferson Laboratory, Newport News VA, which measure the ratio of the electric to magnetic form factors of the proton, G{sub E}/G{sub M}, have forced us to reexamine the single photon exchange approximation in lepton-proton elastic scattering. Discrepancies between the ratio obtained via the time-tested Rosenbluth separation method and new polarization transfer measurements, which differ by as much as a factor of three, may be resolved by considering the effect of two photon exchange (TPE). Theoretical corrections for the TPE effect are difficult due to the large number of excited nucleon states that can contribute to the process. The TPE effect can, however, be determined directly by measuring the ratio of the positron-proton to electron-proton elastic scattering cross sections, R = {sigma}(e{sup +})/{sigma}(e{sup -}), since the TPE effect changes sign with the charge of the incident particle. The CLAS TPE experiment at Jefferson Laboratory, will determine the effect of two-photon exchange in elastic lepton-proton scattering by precisely measuring the ratio of positron-proton to electron-proton elastic cross sections over a large kinematic range (0.1<{epsilon}<0.96, 0.02{<=}Q{sup 2}{<=}2.0). We will accomplish this by directing the 5.5 GeV primary electron beam, provided by the Continuous Electron Beam Accelerator Facility (CEBAF), onto a set of radiators and converters to produce simultaneous and identical beams of electron and positrons. Acceptance and efficiency concerns are minimized by only considering the ratios of the elastic cross sections and switching polarity of magnets in the beam line and the spectrometer. Guided by the results of a short 2006 test run and extensive GEANT based modeling, new shielding and beam line components were designed to maximize luminosity. The unique experimental design and challenges of the TPE experiment and the projected luminosities will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗