Search NASA⌕ Search

SEARCH · Search NASA

Results for “COLLECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Performance evaluations of a liquid solar collector

Report presents procedures and results of thermal performance tests on single-covered liquid solar collector under simulated comditions. Test conditions and data are given in tables and graphs for stagnation tests and thermal performance test. In addition, time-constant test and incident-angle modifier test were conducted to determine transient effect and incident-angle effect. Results of collector load tests are also given.

Shih, K.↗

Outdoor tests of a liquid solar collector

Results of outdoor test program evaluating thermal performance of liquid solar collector are presented in report. Test article used is flatplate collector with antifreeze solution as working fluid.

Source record↗

Secondary-electron-emission properties of conducting surfaces with application to multistage depressed collectors for microwave amplifiers

To improve the efficiency of high power microwave tubes, low secondary electron yield electrode surface for use in depressed collectors are needed. The secondary emission characteristics of a number of materials were investigated. The materials studied were beryllium, carbon (soot and pyrolytic graphite), copper, titanium carbide, and tantalum. Both total secondary yield delta and relative reflected primary yield were measured. These measurements were made in conjunction with Auger spectroscopy so that the secondary emission characteristics could be determined as a function of surface contamination or purity. The results show that low atomic weight elements, such as beryllium and carbon, have the lowest reflected primary yield and that roughening the surface of an electrode can markedly decrease secondary yield both for delta and reflected primaries. All factors considered, a roughened pyrolytic graphite surface showed the greatest potential for use as an electrode surface in depressed collectors.

Forman, R.↗

Projection of distributed-collector solar-thermal electric power plant economics to years 1990-2000

A preliminary comparative evaluation of distributed-collector solar thermal power plants was undertaken by projecting power plant economics of selected systems to the 1990 to 2000 time frame. The selected systems include: (1) fixed orientation collectors with concentrating reflectors and vacuum tube absorbers, (2) one axis tracking linear concentrator including parabolic trough and variable slat designs, and (3) two axis tracking parabolic dish systems including concepts with small heat engine-electric generator assemblies at each focal point as well as approaches having steam generators at the focal point with pipeline collection to a central power conversion unit. Comparisons are presented primarily in terms of energy cost and capital cost over a wide range of operating load factors. Sensitvity of energy costs for a range of efficiency and cost of major subsystems/components is presented to delineate critical technological development needs.

Fujita, T.↗

Test and analysis of a Northrup collector controller

The collector controller was examined as a functioning control system that drives the Northrup collector from east to west to follow the sun then back to the east at sundown in readiness for the next sunrise. The major components were examined separately with particular emphasis placed on an analysis of the electronic drive circuit. Results are presented from hardware testing and analysis with recommended changes to improve the system.

Scott, D. R.↗

Verification test of the MSFC solar simulator using a Honeywell double-covered liquid solar collector

Additional verification data to support the utilization of the MSFC Solar Simulator for testing solar collectors was obtained. The Honeywell double-covered liquid solar collector number 2 for which thermal performance data under natural outdoor conditions had been previously obtained was installed on the Solar Simulator and subjected to a series of eight tests under various conditions of wind flow rate. Although these test conditions were not absolutely identical to those of the outdoor tests, they are considered to be sufficiently representative to provide a basis for an accurate comparative analysis of the data recorded for both test programs.

Shih, K., Sr.↗

Indoor test for thermal performance evaluation of Libbey-Owens-Ford solar collector

The thermal performance of a flat plate solar collector that uses liquid as the heat transfer medium was investigated under simulated conditions. The test conditions and thermal performance data obtained during the tests are presented in tabular form, as well as in graphs. Data obtained from a time constant test and incident angle modifier test, conducted to determine transient effect and the incident angle effect on the collector, are included.

Shih, K.↗

A low cost high temperature sun tracking solar energy collector

The design and economic evaluation of a low cost high temperature two axis sun tracking solar energy collector are described. The collector design is specifically intended for solar energy use with the freedom of motion about its two control axes being limited only to the amplitude required to track the sun. An examination of the performance criteria required in order to track the sun and perform the desired solar energy conversion is used as the starting point and guide to the design. This factor, along with its general configuration and structural aspect ratios, is the significant contributor to achieving low cost. The unique mechanical design allows the control system to counter wide tolerances that will be specified for the fabrication of the azimuth frame and perform within a small tracking error.

Perkins, G. S.↗

Installation package for air flat plate collector

The Solar 2 dimensions are four feet by eight feet by two and one half inches. The collector weighs 130 pounds and has an effective solar collection area of over 29.5 square feet. This area represents 95 percent of the total surface of the collector. The installation, operation and maintenance manual, safety hazard analysis, special handling instructions, materials list, installation concept drawings, warranty and certification statement are included in the installation package.

Source record↗

Preliminary design review package on air flat plate collector for solar heating and cooling system

Guidelines to be used in the development and fabrication of a prototype air flat plate collector subsystem containing 320 square feet (10-4 ft x 8 ft panels) of collector area are presented. Topics discussed include: (1) verification plan; (2) thermal analysis; (3) safety hazard analysis; (4) drawing list; (5) special handling, installation and maintenance tools; (6) structural analysis; and (7) selected drawings.

Source record↗

Use of the Marshall Space Flight Center solar simulator in collector performance evaluation

Actual measured values from simulator checkout tests are detailed. Problems encountered during initial startup are discussed and solutions described. Techniques utilized to evaluate collector performance from simulator test data are given. Performance data generated in the simulator are compared to equivalent data generated during natural outdoor testing. Finally, a summary of collector performance parameters generated to date as a result of simulator testing are given.

Humphries, W. R.↗

Preliminary design package for solar collector and solar pump

A solar-operated pump using an existing solar collector, for use on solar heating and cooling and hot water systems is described. Preliminary design criteria of the collector and solar-powered pump is given including: design drawings, verification plans, and hazard analysis.

Source record↗

Air-liquid solar collector for solar heating, combined heating and cooling, and hot water subsystems

A collection of quarterly reports consisting of the installation and layout design of the air collector system for commercial applications, completion of the preliminary design review, detailed design efforts, and preparation of the verification test plan are given. Performance specifications and performance testing of a prototype model of a two manifold, 144 tube air collector array is presented.

Source record↗

Development of prototype air/liquid solar collector subsystem

Testing of the evacuated tubular air collector in conjunction with air/liquid heat exchange and liquid storage elements was completed. Test results emphasize matching of heat exchanger and collector characteristics with specific attention to the dynamic response of each of the elements.

Source record↗

Installation package for concentrating solar collector panels

The concentrating solar collector panels comprise a complete package array consisting of collector panels using modified Fresnel prismatic lenses for a 10 to 1 concentrating ratio, supporting framework, fluid manifolding and tracking drive system, and unassembled components for field erection.

Source record↗

Secondary electron emission properties of conducting surfaces for use in multistage depressed collectors

An Auger spectrometer in ultrahigh vacuum was used to measure the secondary emission properties of a number of candidate collector-materials including beryllium, carbon, (soot and pyrolytic graphite), copper, titanium carbide and tantalum. The advantage of the technique used is that the surface chemical constituents could be determined just before the secondary emission characteristics of the surface were measured. Pyrolytic graphite roughened by sputter etching showed the most favorable results for depressed collector use.

Forman, R.↗

High-performance solar collector

Evacuated all-glass concentric tube collector using air or liquid transfer mediums is very efficient at high temperatures. Collector can directly drive existing heating systems that are presently driven by fossil fuel with relative ease of conversion and less expense than installation of complete solar heating systems.

Beekley, D. C.↗