Search NASA⌕ Search

SEARCH · Search NASA

Results for “CORROSIVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Effects of Variations in Salt-Spray Conditions on the Corrosion Mechanisms of an AE44 Magnesium Alloy

The understanding of how corrosion affects magnesium alloys is of utmost importance as the automotive and aerospace industries have become interested in the use of these lightweight alloys. However, the standardized salt-spray test does not produce adequate corrosion results when compared with field data, due to the lack of multiple exposure environments. This research explored four test combinations through three sets of cycles to determine how the corrosion mechanisms of pitting, intergranular corrosion, and general corrosion were affected by the environment. Of the four test combinations, Humidity-Drying was the least corrosive, while the most corrosive test condition was Salt Spray-Humidity-Drying. The differences in corrosivity of the test conditions are due to the various reactions needed to cause corrosion, including the presence of chloride ions to cause pit nucleation, the presence of humidity to cause galvanic corrosion, and the drying phase which trapped chloride ions beneath the corrosion by-products.

Martin, Holly J.↗

Corrosion Potential of Selected Bio-blendstock Fuel Candidates for Boosted Spark Ignited Engines

Eight bio-blendstock fuel candidates for boosted spark ignited engines were evaluated for their susceptibility to corrode infrastructure metals. These candidates included five alcohols (methanol, ethanol, isobutanol, n-propanol, and isopropanol), diisobutylene, mixed furans, and aromatics. Methanol was also added to the list for comparison. These molecules are not corrosive to metals since they cannot dissociate into ions and anions. However, the addition of contaminants and a separate water phase may facilitate corrosion due to phenomena associated with the formation of ions and anions (from key contaminants), differential aeration cell (due to dissolved oxygen), and microbial-induced corrosion. A literature review was conducted to determine the influence of these phenomena on corrosion for the nine fuel candidates. In addition, the oxygen solubility of each fuel type was determined to ascertain their relative influence on forming and enhancing a differential aeration cell. Of the fuel candidates, only the alcohols are water soluble, and therefore have an opportunity to cause corrosion. However, differential aeration cells, by themselves have not been shown to contribute to corrosion. Other factors, such as galvanic coupling and/or crevice regions are necessary to promote corrosion in laboratory conditions. However, differential aeration as a corrosion mechanism has not been established in the field. Likewise, microbial-induced corrosion is another known corrosion pathway that has yet to be positively identified for blends of the fuel candidates with gasoline. In summary, corrosion is not anticipated with any of the bio-blendstock candidates with infrastructure metals.

09 BIOMASS FUELS↗

Predicting and Controlling Corrosion (Abbreviated Final Report)

Corrosion accumulates significant replacement costs in the transportation, utility, manufacturing, and infrastructure sectors. It also underpins several of LLNL’s core missions in stockpile stewardship, defense, and energy security. Whereas most corrosion and aging models are empirically parameterized to describe well-defined conditions late in the reaction, the factors that determine the early stages of corrosion—during which mitigation could be most impactful— are poorly understood. This project addressed the critical need for new approaches to predict the kinetics of corrosion initiation based on firm physical and chemical understanding. The activities encompassed degradation of relevant metals in both hydrogen-rich and environmental corrosion scenarios. The team integrated state-of-the-art multiscale simulation, in situ characterization, and data science within three technical thrusts: hydriding of Ti alloys; aqueous corrosion of Al and Ni-Cr alloys; and degradation of additively manufactured 316L stainless steel. In each case, novel capabilities were developed to identify and track the impacts of key atomistic, compositional, and microstructural features on the metal systems. For hydriding, protocols were developed to tightly integrate multiscale models, advanced multimodal characterization, and machine learning to determine how hydrogen interacts with native passivating surface oxides and nucleates new undesired phases, shedding new light on the critical role of grain boundaries, interfaces, and atomically disordered regions. For aqueous corrosion, the project demonstrated methods to predict dissolution rates of metal surfaces in corrosive solutions, to measure and understand microstructural and grain orientation effects on corrosion susceptibility, and to investigate competing growth and dissolution kinetics of surface oxides. For additively manufactured metals, analysis using state-of-the-art microscopy techniques revealed the role of specific heterogeneities invoked during laser processing, including cellular structure, dislocations, and precipitates, on corrosion susceptibility. In addition to new capabilities and understanding, the project provided an avenue for workforce development, as well as key partnerships with stakeholders in corrosion science.

08 HYDROGEN↗

Mitigating Corrosion in Mg Sheet in Conjunction with a Sheet-Joining Method that Satisfies Structural Requirements within Sub-assemblies

This work was undertaken as a LightMAT project funded by the DOE-Vehicles Technology Office. The goal of this work was to develop corrosion protection strategies that simultaneously mitigate corrosion and achieve Class-A surface finish for Mg components in automotive applications. While automotive metals such as steel and aluminum are protected against corrosion through a variety of coating schemes/packages, the efficacy of these existing coating schemes for Mg and Mg- joints is not clear and needs to be determined. Therefore, five commercially available coating schemes and two joining techniques (riveting and Arplas resistance spot welding) were evaluated. The corresponding individual Mg sheet coupons or Mg/Mg joint test coupons were provided by Magna that were then corrosion tested at PNNL using ASTM B117 procedure. The microstructures and mechanical properties of the coupons were analyzed to determine the effectiveness of the joining and corrosion mitigation strategies. Of the coating schemes evaluated, Henkel Bonderite MgC 2.0 pre-treatment + E-coat showed the best corrosion protection and surface finish for individual Mg coupons and Arplas resistance spot welded coupons. However, the strength of Mg/Mg welded joint was reduced after corrosion testing due to some corrosion at the weld nugget. Mg/Mg rivet joints in conjunction with Chemetall oxisilan pre-treatment + polyurethane coating showed good corrosion resistance and some discoloration on the surface finish. Coating schemes comprising pre-treatment with Alodine 5200 + E-coat or Bonderite 1455 + polyurethane coating, in conjunction with Al rivet joints, showed significant corrosion and extensive discoloration of the surface. We anticipate that the results from this work will provide useful guidance to the automotive industry in selecting the appropriate combinations of corrosion protection coatings and joining techniques to fabricate light-weight Mg-based automotive components.

36 MATERIALS SCIENCE↗

A Multiscale Inelastic Internal State Variable Corrosion Model

We present a corrosion internal state variable (ISV) damage model based upon the integrated computational materials engineering (ICME) hierarchical multiscale paradigm. Structure–property experiments for magnesium alloys were used where the only inputs were the volume fractions of each element of the periodic table. This macroscale ISV corrosion model finds its basis in Horstemeyer’s mechanical damage model, which includes three separate ISVs for damage nucleation, growth, and coalescence, as well as Walton’s inclusion of corrosion, which introduces five new ISVs for pit nucleation, growth, and coalescence, along with general corrosion and intergranular corrosion. While Walton’s corrosion ISVs are phenomenological in nature, herein we develop a multiscale physical basis for the corrosion ISVs. The parameters for the macroscale corrosion ISVs were garnered from the mesoscale Butler–Volmer equations. Pure magnesium with differing amounts of aluminum were used in corrosion tests to exemplify the different pitting, general corrosion, and intergranular corrosion rates, and the macroscale ISV model was calibrated with said data, in which the only inputs to the model are the volume percentages of the elements magnesium and aluminum. Although magnesium alloys were used to motivate and calibrate the model, the model is abstract enough to possibly capture other material systems as well.

Chemistry↗

Corrosion Prevention in Copper Combustion Chamber Liners of Liquid Oxygen/Methane Booster Engines

Prior research conducted by United Technologies Research Center and Rockwell International Rocketdyne Division encountered severe copper corrosion while flowing hydrocarbon fuels through copper cooling tubes. These experimental results have very important implications for the development of low-cost, regeneratively cooled, oxygen/hydrocarbon bipropellant booster engines. Aerojet TechSystems undertook a program sponsored by NASA/Lewis Research Center in 1986 with two objectives: (1) to define the corrosive interaction process that occurs between hydrocarbon fuels and copper combustion chamber liner materials, using both static and dynamic test methods, and (2) to identify and demonstrate protective measures against this corrosive process. The results of the first program task demonstrated that the most damaging corrosive process was caused by trace amounts of sulfur-containing impurities in the hydrocarbon fuel which react with the copper chamber liner material to form cuprous sulfide (Cu2S), as reported in Paper No. AlAA 88-3215. Experiments were conducted which demonstrated this corrosive process with Mil-Spec RP-1, propane, and methane fuels in contact with OFHC, NASA-Z, and ZrCu coppers. The preliminary results of the second program task demonstrated that electrodeposited gold and platinum coatings held promise of preventing corrosion of copper chamber liners by methane contaminated with sulfur-containing impurities, as reported in Paper No. AIAA 89-2738. Experiments were conducted which demonstrated greatly reduced corrosion of copper by hydrogen sulfide (H2S) and methyl mercaptan (CH3SH) as measured impurities in methane. This paper presents the concluding, confirmatory results from the second program task. The efficacy of a protective gold coating on NASA-Z copper cooling channel walls was conclusively demonstrated. Tests were conducted in the Aerojet Carbothermal Test Facility which provide realistic simulations of booster engine cooling channel conditions such as temperature, pressure, flow velocity, and heat flux. Dynamic test series were performed with methane containing 5 and 10 ppm (by volume) hydrogen sulfide. Gold-plated and unplated copper alloy specimens were evaluated. The tests demonstrated that gold coatings were effective in preventing corrosion of the copper. Posttest metallographic examinations of the unplated specimens showed severe corrosion as a result of reaction with the sulfur containing contaminant in the fuel. In contrast, posttest metallographic examination of the gold-coated specimens showed no corrosion under similar operating conditions. The findings from metallurgical and chemical analyses of the copper specimens, chemical analysis of the methane, and description of all test conditions are provided. Conclusions are reached as to the efficacy of the plating methods and the effectiveness of the metal coatings in the prevention of corrosion in hydrocarbon-fueled booster engine combustion chamber liners.

S D Rosenberg↗

Corrosion Protection of Launch Infrastructure and Hardware Through the Space Shuttle Program

Corrosion, the environmentally induced degradation of materials, has been a challenging and costly problem that has affected NASA's launch operations since the inception of the Space Program. Corrosion studies began at NASA's Kennedy Space Center (KSC) in 1966 during the Gemini/Apollo Programs with the evaluation of long-term protective coatings for the atmospheric protection of carbon steel. NASA's KSC Beachside Corrosion Test Site, which has been documented by the American Society of Materials (ASM) as one of the most corrosive, naturally occurring environments in the world, was established at that time. With the introduction of the Space Shuttle in 1981, the already highly corrosive natural conditions at the launch pad were rendered even more severe by the acidic exhaust from the solid rocket boosters. In the years that followed, numerous efforts at KSC identified materials, coatings, and maintenance procedures for launch hardware and equipment exposed to the highly corrosiye environment at the launch pads. Knowledge on materials degradation, obtained by facing the highly corrosive conditions of the Space Shuttle launch environment, as well as limitations imposed by the environmental impact of corrosion control, have led researchers at NASA's Corrosion Technology Laboratory to establish a new technology development capability in the area of corrosion prevention, detection, and mitigation at KSC that is included as one of the "highest priority" technologies identified by NASA's integrated technology roadmap. A historical perspective highlighting the challenges encountered in protecting launch infrastructure and hardware from corrosion during the life of the Space Shuttle program and the new technological advances that have resulted from facing the unique and highly corrosive conditions of the Space Shuttle launch environment will be presented.

Calle, L. M.↗

Timescale Correlation between Marine Atmospheric Exposure and Accelerated Corrosion Testing

Evaluation of metal-based structures has long relied on atmospheric exposure test sites to determine corrosion resistance in marine environments. Traditional accelerated corrosion testing relies on mimicking the exposure conditions, often incorporating salt spray and ultraviolet (UV) radiation, and exposing the metal to continuous or cyclic conditions of the corrosive environment. Their success for correlation to atmospheric exposure is often a concern when determining the timescale to which the accelerated tests can be related. Accelerated laboratory testing, which often focuses on the electrochemical reactions that occur during corrosion conditions, has yet to be universally accepted as a useful tool in predicting the long term service life of a metal despite its ability to rapidly induce corrosion. Although visual and mass loss methods of evaluating corrosion are the standard and their use is imperative, a method that correlates timescales from atmospheric exposure to accelerated testing would be very valuable. This work uses surface chemistry to interpret the chemical changes occurring on low carbon steel during atmospheric and accelerated corrosion conditions with the objective of finding a correlation between its accelerated and long-term corrosion performance. The current results of correlating data from marine atmospheric exposure conditions at the Kennedy Space Center beachside corrosion test site, alternating seawater spray, and immersion in typical electrochemical laboratory conditions, will be presented. Key words: atmospheric exposure, accelerated corrosion testing, alternating seawater spray, marine, correlation, seawater, carbon steel, long-term corrosion performance prediction, X-ray photoelectron spectroscopy.

Montgomery, Eliza L.↗

Bonding-Compatible Corrosion Inhibitor for Rinsing Metals

A corrosion-inhibiting mixture of compounds has been developed for addition to the water used to rinse metal parts that have been cleaned with aqueous solutions in preparation for adhesive bonding of the metals to rubber and rubber-like materials. Prior to the development of this corrosion inhibitor, the parts (made, variously, of D6AC steel and 7075-T73 aluminum) were rinsed by deionized water, which caused corrosion in some places on the steel parts especially in such occluded places as sealing surfaces and threaded blind holes. An integral part of the particular cleaning process is the deposition of a thin layer of silicates and silane primers that increase the strength of the adhesive bond. The corrosion inhibitor is formulated, not only to inhibit corrosion of both D6AC steel and 7075- T73 aluminum, but also to either increase or at least not reduce the strength of the adhesive bond to be formed subsequently. The corrosion inhibitor is a mixture of sodium silicate and sodium tetraborate. The sodium silicate functions as both a corrosion inhibitor and a bond-strength promoter in association with the silane primers. The sodium tetraborate buffers the rinse solution at the optimum pH and functions as a secondary corrosion inhibitor for the steel. For a given application, the concentrations of sodium silicate and sodium tetraborate must be chosen in a compromise among the needs to inhibit corrosion of steel, inhibit corrosion of aluminum, and minimize cosmetic staining of both steel and aluminum. Concentrations of sodium silicate in excess of 150 parts of silicon per million parts of solution (ppm Si) have been determined to enhance inhibition of corrosion; unfortunately, because of the alkalinity of sodium silicate, even a small concentration can raise the pH of the rinse solution to such a level that aluminum becomes corroded despite the inhibiting effect. The pH of a solution that contains a high concentration of sodium silicate can be decreased by adding sodium tetraborate. On the other hand, the addition of sodium tetraborate increases the concentration of dissolved solids to such a high level that cosmetic staining becomes an issue.

Saunders, C. R.↗

pH Sensitive Microcapsules for Delivery of Corrosion Inhibitors

A considerable number of corrosion problems can be solved by coatings. However, even the best protective coatings can fail by allowing the slow diffusion of oxygen and moisture to the metal surface. Corrosion accelerates when a coating delaminates. Often, the problems start when microscopic nicks or pits on the surface develop during manufacturing or through wear and tear. This problem can be solved by the incorporation of a self-healing function into the coating. Several new concepts are currently under development to incorporate this function into a coating. Conductive polymers, nanoparticles, and microcapsules are used to release corrosion-inhibiting ions at a defect site. The objective of this investigation is to develop a smart coating for the early detection and inhibition of corrosion. The dual function of this new smart coating system is performed by pH-triggered release microcapsules. The microcapsules can be used to deliver healing agents to terminate the corrosion process at its early stage or as corrosion indicators by releasing dyes at the localized corrosion sites. The dyes can be color dyes or fluorescent dyes, with or without pH sensitivity. Microcapsules were formed through the interfacial polymerization process. The average size of the microcapsules can be adjusted from 1 to 100 micron by adjusting the emulsion formula and the microcapsule forming conditions. A typical microcapsule size is around 10 microns with a narrow size distribution. The pH sensitivity of the microcapsule can also be controlled by adjusting the emulsion formula and the polymerization reaction time. Both corrosion indicator (pH indicator) and corrosion inhibitor containing microcapsules were formed and incorporated into paint systems. Test panels of selected steels and aluminum alloys were painted using these paints. Testing of compatibility between the microcapsule system and different paint systems are in progress. Initial experiments with the microcapsule containing paint show visible color changes at induced corrosion sites and improvement of corrosion protection. Further investigation of the performance of the coating using electrochemical techniques and long term exposure are currently underway.

Li, Wenyan↗

Timescale Correlation between Marine Atmospheric Exposure and Accelerated Corrosion Testing - Part 2

Evaluation of metals to predict service life of metal-based structures in corrosive environments has long relied on atmospheric exposure test sites. Traditional accelerated corrosion testing relies on mimicking the exposure conditions, often incorporating salt spray and ultraviolet (UV) radiation, and exposing the metal to continuous or cyclic conditions similar to those of the corrosive environment. Their reliability to correlate to atmospheric exposure test results is often a concern when determining the timescale to which the accelerated tests can be related. Accelerated corrosion testing has yet to be universally accepted as a useful tool in predicting the long-term service life of a metal, despite its ability to rapidly induce corrosion. Although visual and mass loss methods of evaluating corrosion are the standard, and their use is crucial, a method that correlates timescales from accelerated testing to atmospheric exposure would be very valuable. This paper presents work that began with the characterization of the atmospheric environment at the Kennedy Space Center (KSC) Beachside Corrosion Test Site. The chemical changes that occur on low carbon steel, during atmospheric and accelerated corrosion conditions, were investigated using surface chemistry analytical methods. The corrosion rates and behaviors of panels subjected to long-term and accelerated corrosion conditions, involving neutral salt fog and alternating seawater spray, were compared to identify possible timescale correlations between accelerated and long-term corrosion performance. The results, as well as preliminary findings on the correlation investigation, are presented.

Montgomery, Eliza L.↗

Corrosion Mechanism and Applicability Assessment of N80 and 9Cr Steels in CO{sub 2} Auxiliary Steam Drive

Corrosion tests were conducted in a high-temperature high-pressure (HTHP) autoclave to simulate the conditions of CO{sub 2} auxiliary steam drive in gas injection wells. Weight loss tests were performed with the sheets of N80 and 9Cr steels under the testing conditions. The morphology and composition of corrosion products were explored by SEM, EDS, XRD and XPS. The corrosion resistance of 9Cr steel was better than that of N80 steel under the testing conditions. The corrosion rates of N80 and 9Cr met the application requirements in CO{sub 2} auxiliary steam drive. The results broke the constraint in ISO-15156 standards. The corrosion process of N80 steel was mainly affected by the flow velocity. However, the corrosion process of 9Cr steel was mainly affected by temperature. The corrosion resistance of 9Cr steel depended on the FeCO{sub 3} content of Cr-rich layer, which was closely related to temperature. The low flow velocity influenced the diffusion process of N80 steel corrosive ions, whereas the high flow velocity influenced the integrity of corrosion scales. Considering the influence of flow velocity on the corrosion of tubing and casing, in the gas injection well, 9Cr steel and N80 steel were, respectively, selected as the materials of tubing and casing.

36 MATERIALS SCIENCE↗

Burst pressure models and validations for thick-walled pipelines containing corrosion defects

Corrosion is one major threat to pipeline integrity. Over the past decades, many corrosion models have been developed for determining the remaining strength of corroded pipelines, including ASME B31.G, Modified B31.G, LPC, PCORRC and their modified models. All these corrosion models are applicable only to large diameter, thin-walled pipelines with a diameter to wall thickness ratio D/t ≥ 20. In practice, many pipelines have a small diameter and thick wall with a D/t ratio < 20, and thus an adequate corrosion model is needed for assessing remaining strength for corroded thick-walled pipelines. This paper briefly reviews the theoretical burst pressure models for defect-free thin and thick-walled pipelines and four representative corrosion assessment models for thin-walled corroded pipelines. On this basis, two modified corrosion models are proposed to thick-walled pipelines in terms of the average shear stress yield theory. To verify the proposed corrosion models, comprehensive validations are performed. Numerical validations include the elastic-plastic finite element analysis to determine burst pressure for pipelines without and with corrosion defects and the model evaluation using a large dataset of available FEA results of burst pressure for machined defects. Experimental validations include a set of burst pressure tests for defect-free thick-walled pipes with different thicknesses and the model evaluation using one large burst dataset for machined defects with flat bottoms and another large dataset for real corrosion defects with curved river bottom profiles. Both numerical and experimental validations show that the proposed corrosion models can more accurately predict the remaining strength for corroded thin and thick-walled pipelines.

Pipeline↗

Effects of sulfur loading on the corrosion behaviors of metal lithium anode in lithium–sulfur batteries

Highlights: • The effects of sulfur loading on the corrosion behaviors were investigated systematically. • The corrosion became severer with increasing sulfur loading or cycle times. • The corrosion films are porous and loose and cannot prevent further reaction between lithium and polysulfides. - Abstract: The corrosion behaviors in rechargeable lithium–sulfur batteries come from the reactions between polysulfides and metal lithium anode, and they are significantly influenced by the sulfur loading. While there are limited papers reported on the effects of sulfur loading on the corrosion behaviors. In this paper, the effects have been investigated systematically. The corrosion films consisted of insulating lithium ion conductors are loose and porous, so that the corrosive reactions cannot be hindered. The thickness of the corrosion layers, consequently, increased along with increasing sulfur loading or cycle times. For instance, the thickness of corrosion layers after 50 cycles was 98 μm in the cell with 5 mg sulfur while it reached up to 518 μm when the loading increased to 15 mg. The continuous deposition of corrosion products gave rise to low active materials utilization and poor cycling performance.

36 MATERIALS SCIENCE↗

Triacetic Acid Lactone and 4-Hydroxycoumarin as Bioprivileged Molecules for the Development of Performance-Advantaged Organic Corrosion Inhibitors

Biomass conversion, especially the development of bioprivileged molecules utilizing integration of biological and chemical processes, has shown potential to produce novel chemicals with enhanced properties. Here, organic corrosion inhibitors based on triacetic acid lactone and 4-hydroxycoumarin have been synthesized in good yield and tested for corrosion inhibition on mild steel in both sulfuric acid and hydrochloric acid. Sixteen novel corrosion inhibitors derived from triacetic acid lactone and 4-hydroxycoumarin were efficiently synthesized and twelve of them showed high corrosion inhibition efficiency as confirmed by electrochemical impedance spectroscopy (giving values greater than 78%) and polarization analysis. While triacetic acid lactone-based compounds showed good corrosion inhibition performance, the 4-hydroxycoumarin-based compounds showed further improvement in corrosion inhibition performance. Scanning electron microscopy (SEM) analysis of the mild steel coupon in the presence of selected inhibitors showed that corrosion was significantly diminished, with complementary X-ray photoelectron spectroscopy (XPS) analysis suggesting the inhibitor molecules strongly adsorbed on the steel surface. Quantum chemical calculations showed poor correlation between calculated parameters and the performance of these molecules. This large set of corrosion inhibitors containing a dozen promising corrosion inhibitors is useful for future rational design of corrosion inhibitors. In conclusion, the results demonstrate a new direction for the development of bioprivileged molecules.

09 BIOMASS FUELS↗

Corrosion of Candidate Materials in Molten FLiBe Salt for Fluoride-Salt-Cooled High-Temperature Reactor (FHR)

Molten fluoride salts have attracted considerable attention because of their desirable thermophysical properties that lead to superior heat transfer. Recently, fluoride salts are being considered as coolants in the fluoride salt-cooled high temperature reactors (FHRs). The successes of the molten salt reactor experiment (MSRE) program in 1950's-70's at Oak Ridge National Laboratory (ORNL) has also driven the pursuit of molten salt nuclear reactor as one of the lead next generation nuclear reactor concepts. Unlike MSRE where the uranium fuel was dissolved in the molten fluoride salt, the FHR concept is expected to use molten salt (2LiF-BeF{sub 2}, FLiBe) only as coolant in conjunction with solid TRISO fuel particles immersed in the molten salt. One of the important challenges in FHR development is corrosion of structural materials in high-temperature molten 2LiF-BeF{sub 2} (FLiBe) salt. Currently, 316 stainless steel (nominal composition: Fe-12Ni-17Cr-2.5Mo-1Si-2Mn-0.03C) and Hastelloy N (nominal composition: Ni-7Cr-16Mo-5Fe-1Si-0.8Mn) are deemed as promising candidate alloys for the construction of some of the structural components of FHR. 316 stainless steel is ASME code certified for high temperatures (up to 760 deg. C) applications. Hastelloy N has been shown to have outstanding corrosion resistance in molten FLiBe but present code certification data limit the use of this alloy to only about 704 deg. C. Modifications of Hastelloy N with higher creep strength are presently being developed at ORNL. Other materials such graphite, SiC/SiCf and C/Cf composites, are also considered for structural applications in the FHR. The presence of these multiple materials in a molten FLiBe salt medium can further exacerbate and complicate corrosion effects. Therefore, it is necessary to understand the corrosion behavior of these materials in molten FLiBe salt. The corrosion behavior of Hastelloy N, 316 stainless steel, and CVD SiC and two types of SiC-SiC{sub f} composites have been tested in molten FLiBe salt at 700 deg. C. When tested in metal-lined crucibles both Hastelloy N and 316 stainless steel showed very good corrosion resistance. Samples tested in graphite crucibles showed greater propensity for corrosion and carburization was observed in the near surface regions of the alloys. CVD SiC showed outstanding corrosion resistance. However, the two SiC-SiC{sub f} composites exhibited corrosion attack implying that the manufacturing process may play a role in the corrosion of these composites. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Investigation of Corrosion Behavior of Ti/TiN Multilayers on Al7075 Deposited by High-Vacuum Magnetron Sputtering in 3.5% NaCl Solution

Although Al 7075 has many favorable mechanical properties such as the large strength-to-weight ratio, the relatively poor corrosion resistance has restricted industrial applications. In this work, Ti/TiN as hard multilayered and nanostructured coatings are deposited on the relatively soft Al 7075 structure by high-vacuum radio-frequency magnetron sputtering and the phase, structure, and morphology are investigated in details. The corrosion behavior is evaluated by electrochemical impedance spectroscopy in 3.5% NaCl at a pH of 7.5 for 1, 6, 12, 24, 36, 48, 60, and 72 h. At time points of 1, 6, 12, and 24 h, primary oxide layers and double layers are formed, but the corrosive medium penetrates the primary titanium nitride columnar structure. At longer time points of 24, 36, 48, 60, and 72 h, formation of stronger oxide and double layers leads to better corrosion resistance which is 14.8 times better than that observed from the uncoated substrate after immersion for 36 h. According to R{sub ct}, the corrosion resistances of the short and long immersion groups are 808.5-1984 and 808.5-1248 kΩ cm{sup 2}, respectively, thereby confirming the effectiveness of the Ti/TiN coating against corrosion in comparison with the corrosion resistance of 84.3 kΩ cm{sup 2} observed from the uncoated Al 7075. The smallest corrosion resistance of 808.5 kΩ cm{sup 2} observed at the time point of 24 h is 9.6 times that of the uncoated substrate. Graphical Abstract: A 1.4-µm-thick Ti/TiN hard nanostructured coating comprising six layers is deposited on the relatively soft Al 7075 substrate by high-vacuum radio-frequency magnetron sputtering at 100 °C. The first layer of the intermediate Ti layer cannot improve the corrosion resistance of the TiN super hard coating with a columnar structure. The second and third intermediate Ti layers play an important role in improving the corrosion resistance of Al 7075 by obstructing defects and coating damage from aggressive Cl{sup −} ions and penetration of water. The mechanism involves self-healing of defects by oxide formation and Warburg resistance by diffusion control. .

36 MATERIALS SCIENCE↗

Effects of blended cements and carbonation on chloride-induced corrosion propagation

Highlights: • Corrosion propagation of blended cements was investigated for 1 year. • Carbonated and non‑carbonated mortars were evaluated. • Galvanostatic pulse and ER sensors were used to monitor corrosion. • Mortar properties were correlated with corrosion rates and corrosion damage. • Relationships between mortar properties and corrosion behaviour were established. Supplementary cementitious materials are known to refine the pore structure of concrete and accelerate the carbonation progress. The combination of the two processes can have both beneficial and disadvantageous effects on corrosion, especially when chlorides are also involved. In this study the corrosion properties of multiple blended cements were evaluated in carbonated and non‑carbonated states, with chlorides introduced through cyclic ponding. The examination involved monitoring the propagation phase, determining the microstructural properties of cements, and assessing the final corrosion damage. The results showed that the steel in the blended cements initially had a relatively high corrosion activity, which later decreased compared to the OPC. This stabilisation was presumably due to the beneficial changes to the pore structure. Carbonation had a significant impact on the corrosion, with carbonated mortars revealing shallower damage over a larger surface area. This effect was more pronounced for blended cements that exhibited greater susceptibility to carbonation.

36 MATERIALS SCIENCE↗