Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Three dimensional intensity modulated brachytherapy (IMBT): Dosimetry algorithm and inverse treatment planning

Purpose: The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is to introduce the concept of three dimensional (3D) intensity modulated brachytherapy and solve two fundamental issues regarding the application of 3D IMBT treatment planning: The dose calculation algorithm and the inverse treatment planning method. Methods: A 3D IMBT treatment planning system prototype was developed using the MATLAB platform. This system consists of three major components: (1) A comprehensive IMBT source calibration method with dosimetric inputs from Monte Carlo (EGSnrc) simulations; (2) a ''modified TG-43'' (mTG-43) dose calculation formalism for IMBT dosimetry; and (3) a physical constraint based inverse IMBT treatment planning platform utilizing a simulated annealing optimization algorithm. The model S700 Axxent electronic brachytherapy source developed by Xoft, Inc. (Fremont, CA), was simulated in this application. Ten intracavitary accelerated partial breast irradiation (APBI) cases were studied. For each case, an ''isotropic plan'' with only optimized source dwell time and a fully optimized IMBT plan were generated and compared to the original plan in various dosimetric aspects, such as the plan quality, planning, and delivery time. The issue of the mechanical complexity of the IMBT applicator is not addressed in this study. Results: IMBT approaches showed superior plan quality compared to the original plans and the isotropic plans to different extents in all studied cases. An extremely difficult case with a small breast and a small distance to the ribs and skin, the IMBT plan minimized the high dose volume V{sub 200} by 16.1% and 4.8%, respectively, compared to the original and the isotropic plans. The conformity index for the target was increased by 0.13 and 0.04, respectively. The maximum dose to the skin was reduced by 56 and 28 cGy, respectively, per fraction. Also, the maximum dose to the ribs was reduced by 104 and 96 cGy, respectively, per fraction. The mean dose to the ipsilateral and contralateral breasts and lungs were also slightly reduced by the IMBT plan. The limitations of IMBT are the longer planning and delivery time. The IMBT plan took around 2 h to optimize, while the isotropic plan optimization could reach the global minimum within 5 min. The delivery time for the IMBT plan is typically four to six times longer than the corresponding isotropic plan. Conclusions: In this study, a dosimetry method for IMBT sources was proposed and an inverse treatment planning system prototype for IMBT was developed. The improvement of plan quality by 3D IMBT was demonstrated using ten APBI case studies. Faster computers and higher output of the source can further reduce plan optimization and delivery time, respectively.

60 APPLIED LIFE SCIENCES↗

On asymmetric dark matter constraints from the asteroseismology of a subgiant star

ABSTRACT The asteroseismic modelling of solar-like stars has proved to be valuable in constraining dark matter. In this work, we study for the first time the influence of asymmetric dark matter (ADM) in the evolution of a subgiant star (KIC 8228742) by direct comparison with observational data. Both spectroscopic and seismic data are analysed with a new approach to the stellar calibration method, in which DM properties can also be considered as free inputs. In another phase of this study, a calibrated standard stellar model (without DM) is used as the benchmark for DM models. We find that the latter models consistently outperform the former for 10−40 ≤ σSD < 10−38 cm2, hinting that the presence of ADM in stars of this type does not go against observations. Moreover, we show that stellar seismology allows us to suggest exclusion limits that complement the constraints set by direct detection experiments. Different seismic observables are proposed to study DM properties and ΔΠℓ is found to be the most reliable, having the potential to build future DM exclusion diagrams. This new methodology can be a powerful tool in the analysis of the data coming from the next generation of asteroseismic missions.

Rato, João (ORCID:0000000320802361)↗

Photon calibration techniques for high resolution cryogenic detectors

Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector’s resolution is larger than the energy of a single photon, a calibration is normally derived using Poisson statistics. In this paper, we clarify the assumptions implicit in this calibration method, before considering how a more realistic model of a detector’s performance will violate these assumptions, biasing the calibration. Lastly, we judge the individual impact of specific detector parameters on our calibration, and conclude with discussion of both the limits of our calculations and the implications for state-of-the art detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-134: Assessing the Capabilities of An MU Model for Fields as Small as 2cm in a Passively Scattered Proton Beam

Purpose: To assess and expand the capabilities of the current MU model for a passively scattered proton beam. The expanded MU model can potentially be used to predict the dose/MU for fields smaller than 2cm in diameter and reduce time needed for physical calibrations. Methods: The current MU model accurately predicted the dose/MU for more than 800 fields when compared to physical patient calibrations. Three different ion chambers were used in a Plastic Water phantom for physical measurements: T1, PIN, and A-16. The original MU model predicted output for fields that were affected by the bolus gap factor (BGF) and nozzle extension factor (NEF). As the system was tested for smaller treatment fields, the mod wheel dependent field size factor (MWDFSF) had to be included to describe the changes observed in treatment fields smaller than 3cm. The expanded model used Clarkson integration to determine the appropriate value for each factor (field size factor (FSF), BGF, NEF, and MWDFSF), to accurately predict the dose/MU for fields smaller than 2.5cm in effective diameter. Results: The expanded MU model demonstrated agreement better than 2% for more than 800 physical calibrations that were tested. The minimum tested fields were 1.7cm effective diameter for 149MeV and 2.4cm effective diameter for 186MeV. The inclusion of Clarkson integration into the MU model enabled accurate prediction of the dose/MU for very small and irregularly shaped treatment fields. Conclusion: The MU model accurately predicted the dose/MU for a wide range of treatment fields used in the clinic. The original MU model has been refined using factors that were problematic to accurately predict the dose/MU: the BGF, NEF, and MWDFSF. The MU model has minimized the time for determining dose/MU and reduced the time needed for physical calibrations, improving the efficiency of the patient treatment process.

60 APPLIED LIFE SCIENCES↗

Systematic Biases in Weak Lensing Cosmology with the Dark Energy Survey

This thesis sets out a practical guide to applying shear measurements as a cosmological tool. We first present one of two science-ready galaxy shape catalogues from Year 1 of the Dark Energy Survey (DES Y1), which covers 1500 square degrees in four bands $griz$, with a median redshift of $0.59$. We describe the shape measurement process implemented by the DES Y1 imshape catalogue, which contains 21.9 million high-quality $r$-band bulge/disc fits. In Chapter 3 a new suite of image simulations, referred to as Hoopoe, are presented. The Hoopoe dataset is tailored to DES Y1 and includes realistic blending, spatial masks and variation in the point spread function. We derive shear corrections, which we show are robust to changes in calibration method, galaxy binning and variance within the simulated dataset. Sources of systematic uncertainty in the simulation-based shear calibration are discussed, leading to a final estimate of the $1\sigma$ uncertainties in the residual multiplica tive bias after calibration of 0.025. Chapter 4 describes an extension of the analysis on the Hoopoe simulations into a detailed investigation of the impact of galaxy neighbours on shape measurement and shear cosmology. Four mechanisms by which neighbours can have a non-negligible influence on shear measurement are identified. These effects, if ignored, would contribute a net multiplicative bias of $m \sim 0.03 - 0.09$ in DES Y1, though the precise impact will depend on both the measurement code and the selection cuts applied. We use the cosmological inference pipeline of DES Y1 to explore the cosmological implications of neighbour bias and show that omitting blending from the calibration simulation for DES Y1 would bias the inferred clustering amplitude $S_8 \equiv \sigma_8 (\omegam /0.3)^{0.5}$ by $1.5 \sigma$ towards low values. Finally, we use the Hoopoe simulations to test the effect of neighbour-induced spatial correlations in the multiplicative bias. We find the cosmo logical impact to be subdominant to statistical error at the! current level of precision. Another major uncertainity in shear cosmology is the accuracy of our ensemble redshift distributions. Chapter 5 presents a numerical investigation into the combined constraining power of cosmic shear, galaxy clustering and their cross-correlation in DES Y1, and the potential for internal calibration of redshift errors. Introducing a moderate uniform bias into the redshift distributions used to model the weak lensing (WL) galaxies is shown to produce a $> 2\sigma$ bias in $S_8$. We demonstrate that this cosmological bias can be eliminated by marginalising over redshift error nuisance parameters. Strikingly, the cosmological constraint of the combined dataset is largely undiminished by the loss of prior information on the WL distributions. We demonstrate that this implicit self-calibration is the result of complementary degeneracy directions in the combined data. In Chapter 6 we present the preliminary results of an investigation into galaxy intrin sic alignments. Using the DES Y1 data, we show a clear dependence in alignment amplitude on galaxy type, in agreement with previous results. We subject these findings to a series of initial robustness tests. We conclude with a short overview of the work presented, and discuss prospects for the future.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-C-304-03: Experimental Investigation On the Accuracy of Plastic Scintillation Dosimeters in Small Fields

Purpose: To investigate the accuracy of the Exradin W1 (SI) and of an “in-house” plastic scintillation dosimeter (CHUQ PSD) in small radiation fields. Methods: Output factor (OF) measurements with the W1 and CHUQ PSD were performed for field sizes of 0.5 x 0.5, 1 x 1 and 2 x 2 cm{sup 2}. Both detectors were placed parallel to the central axis (CAX) in water. The spectrum discrimination calibration method was performed in each set-up to account for the Cerenkov (CRV) signal created in the fiber. The OFs were compared to the expected field factors in water derived using i) Monte Carlo (MC) simulations of an accurate accelerator model and ii) microLion (PTW) and D1V diode (SI) OFs. MC-derived correction factors were applied to both the microLion and D1V OFs. For the CHUQ PSD the calibration was repeated in water (// CAX), solid water (perpendicular to CAX) and under a shielded configuration. The signal was collected using a spectrometer (wavelength range = 185–1100 nm). Spectral analysis was performed to evaluate potential changes of the spectral distributions under the various calibration set-up configurations. Results: The W1 OFs presented an over-response for the 0.5 x 0.5 cm{sup 2} in the range of 3 – 4.1% relative to the expected field factor. The CHUQ PSD presented an under-response in the range of 1.5 – 2.7%, without accounting for volume averaging. The CRV spectra under the various calibration procedures appeared similar to each other and only minor changes were observed to the respective OFs. Conclusion: The W1 and CHUQ PSD can be used in small fields down to a 1 x 1 cm{sup 2} field size. Discrepancies were encountered between the two detectors for the smallest field size of 0.5 x 0.5 cm{sup 2} with the CHUQ PSD exhibiting a closer agreement to the expected field factor. Funding sources: 1) Alexander S. Onassis Public Benefit Foundation in Greece and 2) CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council, Grant number: 432290, RGPIN-2014-06475.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Aluminum Scandium Nitride Molecular Dynamics Force Fields with Scalable Multi-Objective Bayesian Optimization

Scandium (Sc)-doped aluminum nitride (AlN) exhibits improved piezoelectric properties, which is favorable for sensor applications. Although many experimental studies exist to fine tune the material properties for design purposes, an atomistic level understanding of the structure-property (S-P) relationships is needed, which is the aim of this work. Molecular dynamics can be used to understand the S-P relationships. However, the limited availability of suitable force fields has been a major challenge for accurate property predictions. In this article, a robust force field calibration method using a scalable multi-objective Bayesian optimization approach is presented. Optimizations with three, six, and eight objectives are applied to calibrate aluminum scandium nitride force fields based on the piezoelectric characteristics, modulus of elasticity, and lattice parameters at different Sc-doped levels. Furthermore, the performances of the different force fields are compared, and the performance of the higher dimensional objective problems is discussed. The highly scalable molecular dynamics force field development method is successfully implemented, resulting in the creation of several aluminum scandium nitride molecular dynamics force fields for piezoelectric applications at varying Sc dope levels.

36 MATERIALS SCIENCE↗

A calibration procedure for sonic infrared nondestructive evaluation

Sonic infrared is potentially a very attractive nondestructive evaluation technique offering the possibility of rapid testing of complex components. However, at present it is difficult to be sure that sufficient excitation has been applied so that a null (no defect present) result can be trusted. This paper presents a calibration method to improve the reliability of the technique. The method uses a measurement of the vibration of the component during the test, the vibration signal being processed to give a 'heating index' which is a measure of the ability of the vibration field to generate heat at any defects of interest that are present. The calculation of the heating index and the rationale for its formulation are described. The method is then applied on two sets of beamlike specimens with cracks of different sizes. The maximum temperature rise in successive tests on a given specimen is shown to correlate well with the maximum heating index, so validating the method. The threshold heating index required to reliably detect cracks as a function of crack size is discussed and practical calibration and test procedures are proposed.

42 ENGINEERING↗

Mock Target Window OTR and IR Design and Testing

In order to fully verify temperature measurements made on the target window using infrared (IR) optical non-contact methods, actual comparative measurements are made with a real beam distribution as the heat source using Argonne National Laboratory’s (ANL) 35 MeV electron accelerator. Using Monte Carlo N-Particle (MCNP) simulations and thermal Finite Element Analysis (FEA), a cooled mock target window with thermocouple implants is designed to be used in such a test to achieve window temperatures up to 700°C. An uncoated and blackcoated mock window is designed to enhance the IR temperature measurements and verify optical transmitted radiation (OTR) imagery. This allows us to fully verify and characterize our temperature accuracy with our current IR camera method and any future method we may wish to explore using actual production conditions. This test also provides us with valuable conclusions/concerns regarding the calibration method we developed using our IR test stand at TA-53 in MPF-14.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relative intensity calibration of the DIII-D charge-exchange recombination spectroscopy system using neutral beam injection into gas

A new calibration method for the DIII-D charge-exchange spectroscopy system produces a smoother impurity density profile compared to previous techniques, thus improving the accuracy of the impurity density profile reconstruction. The relative intensity calibration between the chords of the DIII-D charge-exchange recombination spectroscopy system is performed by firing neutral beams into the evacuated vacuum vessel pre-filled with neutral gas. Relative calibration is required in order to account for uncertainty in the 3D geometry of the neutral beam. Previous methods using helium gas have been improved by using xenon, which emits an emission line close to the commonly used carbon wavelength 5290.5 Å, as well as improved timing of the gas injection, inclusion of variations in the vessel pressure, and timing of neutral beam injection. Photoemission spectra recorded by 112 sightlines viewing 6 neutral beams are compared and used to form a relative calibration factor for each sightline. This relative calibration is shown to improve the quality of the measured ion density profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Method for calibration-free scanned-wavelength modulation spectroscopy for gas sensing

A method of calibration-free scanned-wavelength modulation spectroscopy (WMS) absorption sensing is provided by obtaining absorption lineshape measurements of a gas sample on a sensor using 1f-normalized WMS-2f where an injection current to an injection current-tunable diode laser (TDL) is modulated at a frequency f, where a wavelength modulation and an intensity modulation of the TDL are simultaneously generated, extracting using a numerical lock-in program and a low-pass filter appropriate band-width WMS-nf (n=1, 2, . . . ) signals, where the WMS-nf signals are harmonics of the f, determining a physical property of the gas sample according to ratios of the WMS-nf signals, determining the zero-absorption background using scanned-wavelength WMS, and determining non-absorption losses using at least two of the harmonics, where a need for a non-absorption baseline measurement is removed from measurements in environments where collision broadening has blended transition linewidths, where calibration free WMS measurements without knowledge of the transition linewidth is enabled.

47 OTHER INSTRUMENTATION↗

Incorporating Experimental Information in the Total Monte Carlo Methodology Using File Weights

Some criticism has been directed towards the Total Monte Carlo method because experimental information has not been taken into account in a statistically well-founded manner. In this work, a Bayesian calibration method is implemented by assigning weights to the random nuclear data files and the method is illustratively applied to a few applications. In some considered cases, the estimated nuclear data uncertainties are significantly reduced and the central values are significantly shifted. The study suggests that the method can be applied both to estimate uncertainties in a more justified way and in the search for better central values. Some improvements are however necessary; for example, the treatment of outliers and cross-experimental correlations should be more rigorous and random files that are intended to be prior files should be generated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Physics-driven Explosions of Stripped High-mass Stars: Synthetic Light Curves and Spectra of Stripped-envelope Supernovae with Broad Light Curves

Stripped-envelope supernovae (SESNe) represent a significant fraction of core-collapse supernovae, arising from massive stars that have shed their hydrogen and, in some cases, helium envelopes. The origins and explosion mechanisms of SESNe remain a topic of active investigation. In this work, we employ radiative-transfer simulations to model the light curves and spectra of a set of explosions of single, solar-metallicity, massive Wolf–Rayet stars with ejecta masses ranging from 4 to 11 M ⊙ , which were computed from a turbulence-aided and neutrino-driven explosion mechanism. We analyze these synthetic observables to explore the impact of varying ejecta mass and helium content on observable features. We find that the light curve shape of these progenitors with high ejecta masses is consistent with observed SESNe with broad light curves but not the peak luminosities. The commonly used analytic formula based on rising bolometric light curves overestimates the ejecta mass of these high-initial-mass progenitor explosions by a factor of up to 2.6. In contrast, the calibrated method by Haynie et al., which relies on late-time decay tails, reduces uncertainties to an average of 20% within the calibrated ejecta mass range. Spectroscopically, the He I 1.083 μm line remains prominent even in models with as little as 0.02 M ⊙ of helium. However, the strength of the optical He I lines is not directly proportional to the helium mass but instead depends on a complex interplay of factors such as the 56 Ni distribution, composition, and radiation field. Thus, producing realistic helium features requires detailed radiative transfer simulations for each new hydrodynamic model.

79 ASTRONOMY AND ASTROPHYSICS↗

Computer Model Calibration Based on Image Warping Metrics: An Application for Sea Ice Deformation

Arctic sea ice plays an important role in the global climate. Sea ice models governed by physical equations have been used to simulate the state of the ice including characteristics such as ice thickness, concentration, and motion. More recent models also attempt to capture features such as fractures or leads in the ice. These simulated features can be partially misaligned or misshapen when compared to observational data, whether due to numerical approximation or incomplete physics. In order to make realistic forecasts and improve understanding of the underlying processes, it is necessary to calibrate the numerical model to field data. Traditional calibration methods based on generalized least-square metrics are flawed for linear features such as sea ice cracks. We develop a statistical emulation and calibration framework that accounts for feature misalignment and misshapenness, which involves optimally aligning model output with observed features using cutting-edge image registration techniques. Here, this work can also have application to other physical models which produce coherent structures.

54 ENVIRONMENTAL SCIENCES↗

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared Cloud Imager Instrument Intercomparison Report

The Infrared Cloud Imager Instrument Intercomparison was a guest instrument deployment by NWB Sensors to the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) User Facility observatory on the Southern Great Plains (SGP) between May 18 and December 12, 2023. NWB Sensors is a company that has developed a commercially available infrared cloud imager (ICI). The ICI provides radiometrically calibrated, full-sky images of the downwelling infrared radiance in the 7.3-14 µm band. In addition, it provides cloud radiance as the residual between the observed radiance and the modeled cloud-free radiance as well as derived cloud products. The instrument is used in applications that require consistent detection of clouds across day and night. For more information, consult the instrument's webpage. The primary goal of the deployment was to validate the radiometric accuracy of the ICI. The ICI uses a proprietary calibration method to convert the raw data from its infrared camera into downwelling radiance. Unlike similar instruments, the system does not have an onboard blackbody calibration standard. Instead, NWB Sensors characterizes each ICI camera individually in an environmental chamber while looking at a blackbody standard. The resulting (proprietary) calibration is used operationally in the instrument and has been demonstrated to be stable over long periods. To validate the radiometric products from the ICI, an intercomparison between the ICI data products and those from ARM’s atmospheric emitted radiance interferometer (AERI) was made. The AERI is a best-in-class instrument for measuring downwelling infrared radiance (Gero et al. 2025). A weighted integration of the AERI’s spectral radiances across the ICI’s camera response was performed. The resulting radiance (herein called the AERI radiance) was directly compared to the zenith radiance concurrently observed by the ICI. The results of these comparisons are reported in the next section of this report.

54 ENVIRONMENTAL SCIENCES↗

The Role of Mathematical Methods in Efficiency Calibration and Uncertainty Estimation in Gamma Based Non-Destructive Assay - 12311

Mathematical methods are being increasingly employed in the efficiency calibration of gamma based systems for non-destructive assay (NDA) of radioactive waste and for the estimation of the Total Measurement Uncertainty (TMU). Recently, ASTM (American Society for Testing and Materials) released a standard guide for use of modeling passive gamma measurements. This is a testimony to the common use and increasing acceptance of mathematical techniques in the calibration and characterization of NDA systems. Mathematical methods offer flexibility and cost savings in terms of rapidly incorporating calibrations for multiple container types, geometries, and matrix types in a new waste assay system or a system that may already be operational. Mathematical methods are also useful in modeling heterogeneous matrices and non-uniform activity distributions. In compliance with good practice, if a computational method is used in waste assay (or in any other radiological application), it must be validated or benchmarked using representative measurements. In this paper, applications involving mathematical methods in gamma based NDA systems are discussed with several examples. The application examples are from NDA systems that were recently calibrated and performance tested. Measurement based verification results are presented. Mathematical methods play an important role in the efficiency calibration of gamma based NDA systems. This is especially true when the measurement program involves a wide variety of complex item geometries and matrix combinations for which the development of physical standards may be impractical. Mathematical methods offer a cost effective means to perform TMU campaigns. Good practice demands that all mathematical estimates be benchmarked and validated using representative sets of measurements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗