Results for “Camera calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

The Mars Science Laboratory Curiosity Rover Mastcam Instruments: Preflight and In-Flight Calibration, Validation, and Data Archiving

The NASA Curiosity rover Mast Camera (Mastcam) system is a pair of fixed-focal length, multispectral, color CCD imagers mounted approximately 2 m above the surface on the rover's remote sensing mast, along with associated electronics and an onboard calibration target. The left Mastcam (M-34) has a 34 mm focal length, an instantaneous field of view (IFOV) of 0.22 mrad, and a FOV of 20 deg × 15 deg over the full 1648 × 1200 pixel span of its Kodak KAI-2020 CCD. The right Mastcam (M-100) has a 100 mm focal length, an IFOV of 0.074 mrad, and a FOV of 6.8 deg × 5.1 deg using the same detector. The cameras are separated by 24.2 cm on the mast, allowing stereo images to be obtained at the resolution of the M-34 camera. Each camera has an eight-position filter wheel, enabling it to take Bayer pattern red, green, and blue (RGB) 'true color' images, multispectral images in nine additional bands spanning approximately 400-1100 nm, and images of the Sun in two colors through neutral density-coated filters. An associated Digital Electronics Assembly provides command and data interfaces to the rover, 8 Gb of image storage per camera, 11 bit to 8 bit companding, JPEG compression, and acquisition of high-definition video. Here we describe the preflight and in-flight calibration of Mastcam images, the ways that they are being archived in the NASA Planetary Data System, and the ways that calibration refinements are being developed as the investigation progresses on Mars. We also provide some examples of data sets and analyses that help to validate the accuracy and precision of the calibration.

MSL Mastcam; quantitative multispectral↗

Context Cameras for the Orbiting Carbon Observatory 3 (OCO-3) Instrument

We have developed an adaptable camera platform that takes advantage of screened and qualified commercial off the shelf (COTS) components (CMOS sensor, rad-tolerant microcircuits, lenses) to significantly shorten development time of space-borne visible imaging systems while reducing the overall cost and risk of the development. This modular camera platform is implemented as a suite of two visible-light cameras for the Orbiting Carbon Observatory 3 (OCO-3) instrument at NASA’s Jet Propulsion Laboratory (JPL). The Internal Context Camera (ICC) and External Context Camera (ECC) provide contextual engineering imaging support for the calibration of the OCO-3 instrument, intended to significantly reduce the duration of the mission’s calibration campaign. The OCO-3 mission has taken advantage of the design and qualification work performed by JPL’s Mars 2020 Enhanced Engineering Camera (EECam) team in reusing the qualified COTS CMOS imaging sensor, proven electronic designs, and scalable field-programmable gate array (FPGA) firmware to meet OCO-3’s mission requirements and resource availability. We will be presenting the steps taken by JPL to design, build, and test the Context Cameras for the OCO-3 mission. We will highlight the design deviations from the Mars2020 EECams and discuss the methodology of tailoring the EECam design for the OCO-3 requirements. Camera imaging capabilities, including focal plane and optical performance, will be presented, as well as a summary of the calibration and environmental test results. Finally, we will discuss the potential for future applications for the Context Cameras.

Moore, Douglas↗

Wavefront Sensing With Switched Lenses for Defocus Diversity

In an alternative hardware design for an apparatus used in image-based wavefront sensing, defocus diversity is introduced by means of fixed lenses that are mounted in a filter wheel (see figure) so that they can be alternately switched into a position in front of the focal plane of an electronic camera recording the image formed by the optical system under test. [The terms image-based, wavefront sensing, and defocus diversity are defined in the first of the three immediately preceding articles, Broadband Phase Retrieval for Image-Based Wavefront Sensing (GSC-14899-1).] Each lens in the filter wheel is designed so that the optical effect of placing it at the assigned position is equivalent to the optical effect of translating the camera a specified defocus distance along the optical axis. Heretofore, defocus diversity has been obtained by translating the imaging camera along the optical axis to various defocus positions. Because data must be taken at multiple, accurately measured defocus positions, it is necessary to mount the camera on a precise translation stage that must be calibrated for each defocus position and/or to use an optical encoder for measurement and feedback control of the defocus positions. Additional latency is introduced into the wavefront sensing process as the camera is translated to the various defocus positions. Moreover, if the optical system under test has a large focal length, the required defocus values are large, making it necessary to use a correspondingly bulky translation stage. By eliminating the need for translation of the camera, the alternative design simplifies and accelerates the wavefront-sensing process. This design is cost-effective in that the filterwheel/lens mechanism can be built from commercial catalog components. After initial calibration of the defocus value of each lens, a selected defocus value is introduced by simply rotating the filter wheel to place the corresponding lens in front of the camera. The rotation of the wheel can be automated by use of a motor drive, and further calibration is not necessary. Because a camera-translation stage is no longer needed, the size of the overall apparatus can be correspondingly reduced.

Dean, Bruce H.↗

The EPEC Algorithm for Vision Guided Manipulation: Analysis and Validation

This paper describes the simulated performance and experimental validation of a computationally efficient algorithm for improving positioning accuracy of robot arms using low speed feedback from fixed stereo cameras. The algorithm, called End-Effector Position Error Compensation (EPEC) is robust to visual occlusion of the end-effector and does not require high fidelity calibration of either the arm or stereo camera. The algorithm works by calculating an error vector between the locations of a fiducial on the arm's end-effector as predicted by arm kinematics and detected by a stereo camera triangulation. With this knowledge, the commanded target pose is adjusted to compensate for positioning errors. A simulation environment where arbitrary error can be introduced into arm-camera systems is introduced and used to provide an assessment of the performance of the algorithm under both ideal and degraded conditions.

manipulations↗

The calibratrion of dopplergrams and magnetograms at BBSO

The calibration procedure for the Big Bear Solar Observatory (BBSO) videomagnetograph in which the radial velocity of the sidereal rotation of the Sun is used as a calibrator is described. One of the key points of the procedure is to eliminate the effects of the Earth's motion relative to the Sun and the temperature instability of the birefringent filter by tuning the bandpass of the birefringent filter. The other is to make the light level of the direct image of the videomagnetograph the same both in Doppler and in Zeeman modes in order to reduce the errors introduced by imperfect linearity of the transfer curve of the camera tube. Some practical problems of calibration are discussed for further improvement.

Shi, Z.↗

The performance and calibration of WFPC2 on the Huble Space Telescope

The Wide Field Planetary Camera 2 (WFPC2) was installed in the Hubble Space Telescope (HST) in 1993 December. Since then, the instrument has been providing high-quality images. A significant among of calibration data has been collected to aid in the understanding of the on-orbit performance of the instrument. Generally, the behavior of the camera is similar to its performance during the system-level thermal vacuum test at JPL in 1993 May. Surprises were a significant charge-transfer-efficiency (CTE) problem and a significant growth rate in hot pixels at the original operating temperature of the CCDs (-76 deg C). The operating temperature of the WFPC2 CCDs was changed to -88 deg C on 1994 April 23, and significant improvements in CTE and hot pixels are seen at this temperature. In this paper we describe the on-orbit performance of the WFPC2. We discuss the optical and thermal history, the instrument throughput and stability, the Point Spread Function (PSF), the effects of undersampling on photometry, the properties of cosmic rays observed on-orbit, and the geometric distortion in the camera. We present the best techniques for the reduction of WFPC2 data, and describe the construction of calibration products including superbiases, superdarks, and flat fields.

Holtzman, Jon↗

Photometry of Venus from Mariner 10

Photometry of the upper atmosphere of Venus from Mariner 10 on February 5, 1974 is discussed with respect to in-flight verification of camera linearity, shading, and absolute photometric calibration. Among photometric results are the following: (1) temporal brightness variations were observed in the UV greater than 10% over a few hours due to the rapid rotation of the upper atmosphere, (2) the observed terminator was 4 degrees past the geometric terminator due to detached haze layers at altitudes around 85 km, (3) there were no indications of cloud top elevation variations greater than a few hunderd meters, and (4) in the UV, the bright and dark regions both had low albedos in all scales, showing that the UV absorber is not confined just to dark markings.

Hapke, B.↗

Polar Layered Deposits: Preliminary Stratigraphic Assessment from MGS Observations

Global and hemispheric climatic, volcanic and impact events that modulated the formation of the Martian polar layered deposits can be revealed by detailed stratigraphic analyses of well-exposed sequences of those layers. Complete three-dimensional Mars Orbiting Laser Altimeter (MOLA) topography of the north and south polar deposits is now available, and very abundant Mars Orbiter Camera (MOC) imagery that is well calibrated is becoming available. This paper presents an assessment of the polar stratigraphic potential based on observations from Mars Global Surveyor (MGS) mapping cycles through M7. Additional information can be found in the original extended abstract.

Murray, B. C.↗

Flame Chemiluminescence Rate Constants for Quantitative Microgravity Combustion Diagnostics

Absolute excited state concentrations of OH(A), CH(A), and C2(d) were determined in three low pressure premixed methane-air flames. Two dimensional images of chemiluminescence from these states were recorded by a filtered CCD camera, processed by Abel inversion, and calibrated against Rayleigh scattering, Using a previously validated 1-D flame model with known chemistry and excited state quenching rate constants, rate constants are extracted for the reactions CH + O2 (goes to) OH(A) + CO and C2H + O (goes to) CH(A) + CO at flame temperatures. Variations of flame emission intensities with stoichiometry agree well with model predictions.

Luque, Jorge↗

A Spectralon BRF Data Base for MISR Calibration Application

The Multi-angle Imaging SpectroRadiometer (MISR) is an Earth observing sensor which will provide global retrievals of aerosols, clouds, and land surface parameters. Instrument specifications require high accuracy absolute calibration, as well as accurate camera-to-camera, band-to-band and pixel-to-pixel relative response determinations.

spectralon MISR spectroradiometer remote sensing↗

Automatic Calibration and Health Monitoring of Infrastructure Sensors

Smart transportation infrastructure relies on networks of heterogeneous sensors - cameras, radars, and lidars - continuously monitoring traffic conditions. However, executing the initial spatial calibration of multiple sensors and the subsequent health monitoring presents significant operational challenges. Environmental factors, mechanical vibrations, and gradual drift cause spatial misalignment, degrading fusion performance and tracking accuracy. Traditional calibration approaches require manual intervention with specialized targets or survey equipment, resulting in service interruptions and high maintenance costs. This work presents an automated framework for initial calibration and continuous health monitoring without human intervention or service disruption. Our approach addresses two critical problems: (1) detecting when sensors become miscalibrated during operation, and (2) automatically re-establishing spatial alignment using only operational traffic data. The health monitoring component analyzes measurement innovations - differences between sensor observations and predicted object states - to detect systematic biases indicative of calibration drift. By computing bias magnitude, directional consistency, and rejection rates, the system identifies miscalibrations as small as 0.5 meters. Unlike traditional methods requiring known calibration targets, our diagnostic operates continuously on live traffic observations, enabling early detection before fusion quality degrades. The automatic recalibration algorithm leverages overlapping sensor fields-of-view and temporal correlation of vehicle observations. Using graph-based optimization, the system automatically discovers which sensor pairs observe common regions, estimates pairwise spatial transformations using RANSAC-based robust estimation, and jointly optimizes all sensor poses through bundle adjustment. The framework handles practical deployment challenges, including different sensor sampling rates (1-10 Hz), varying installation positions, unknown orientations, and limited overlap regions (>10%). When approximate sensor positions are available from installation surveys (+/-1m accuracy), the algorithm additionally estimates sensor orientations, refining both position and rotation to sub-meter and sub-degree accuracy. We validate the framework on multi-hour traffic datasets from six heterogeneous sensors with sampling rates ranging from 1 Hz to 10 Hz. Results demonstrate successful calibration even with sparse overlap (<20%) and automatic detection of miscalibrations exceeding 0.8 meters. This work enables a "deploy-and-forget" sensor infrastructure that maintains calibration autonomously, reducing maintenance costs while improving tracking accuracy. The techniques generalize beyond transportation to any multi-sensor monitoring application requiring robust spatial alignment, including smart cities, industrial monitoring, and surveillance systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Laser Illuminated Feature Position Determination and Calibration Approach for PIXL

This paper describes several approaches for the calibration of translational and rotational alignment errors between a camera and a set of laser illuminators for a position determination system. Detailed algorithms are derived and covariance of calibration residuals in both error state and target position determination accuracy are obtained. An example with system design parameters is given to demonstrate the effectiveness of the approaches. The algorithm can be used for any terrestrial or space position determination instruments employing a camera/laser triangulation system and is proposed, as one application, for the PIXL instrument of JPL’s MARS 2020 Rover project.

Liu, John Y.↗

Calibration of the DSCOVR EPIC Visible and NIR Channels using Multiple LEO Radiometers

The first five years of operation of the Deep Space Climate Observatory (DSCOVR) Earth Polychromatic Imaging Camera (EPIC) at the Lagrange one point have produced results that uniquely complement the data from currently operating low orbit Earth-observing instruments. In this paper we describe an updated unified approach to EPIC calibration. In this approach, calibration coefficients and their trends were obtained by comparing EPIC observations to the measurements from polar orbiting radiometers. In this study L1B reflectances from Moderate Resolution Imaging Spectroradiometer (MODIS) onboard the Aqua and Terra satellites, Multi-angle Imaging Spectroradiometer (MISR) onboard Terra and Visible Infrared Imaging Radiometer (VIIRS) onboard the Suomi National Polar-orbiting Partnership (Suomi NPP) spacecraft were used to infer calibration coefficients for four EPIC visible and near-infrared channels: 443 nm, 551 nm, 680 nm, and 780 nm. EPIC Version three measurements made between June 2015 and August 2020 were used for comparison. The calibration procedure identifies the most homogeneous low Earth orbit radiometer scenes matching scattering angles that are temporarily and spatially collocated with EPIC observations. These scenes are used to determine reflectance to count (R/C) ratios in spectrally analogous channels. Seasonal average R/C ratios were analyzed to obtain EPIC calibration gains and trends. The trends for the full dataset period are not statistically significant except in the 443 nm channel. No significant changes in calibration were found after the instrument’s exit from safe hold in March 2020. The R/C ratios were also used to determine the differences in EPIC gains resulting from separate calibrations: against MODIS Aqua or Terra, as well as against forward or aftward MISR cameras. Statistical tests indicate that the differences between the two datasets are not significant except in the 780 nm channels where Aqua-derived coefficients may be around 2% lower compared to Terra. The dependence of EPIC calibration gains on the instrument scattering angle and on DSCOVR-Earth distance were investigated. Lastly, model Low Earth Orbit (LEO) reflectances calculated to match the EPIC viewing geometry were employed to study how EPIC calibration coefficients depend on EPIC-LEO viewing geometry differences. The effect of LEO and EPIC angular mismatch on calibration was shown to be small.

deep space climate observatory/earth polychromatic↗

Improvements to the accuracy of the IUE wavelength scales in high dispersion

The data base of Pt-Ne emission lines used to calibrate the IUE high dispersion wavelength scales was scrutinized to improve the internal consistency of the adopted laboratory wavelength values and provide a homogeneous, documented line list, which IUE Guest Observers may use to evaluate quantitatively those Pt-Ne spectra taken to calibrate their data. After deletion of incorrect or inappropriate data in the old data base (lines with incorrect wavelength assignments; lines which are too faint, too bright, or blended; lines which fall near reseau marks, etc.) and the addition of several new entries, a total of 172 Pt-Ne lines for the SWP camera and 164 Pt-Ne lines for the LWR camera are now used for routine wavelength calibration in the high dispersion mode.

Turnrose, B. E.↗

Temperature-Sensitive Coating Sensor Based on Hematite

A temperature-sensitive coating, based on hematite (iron III oxide), has been developed to measure surface temperature using spectral techniques. The hematite powder is added to a binder that allows the mixture to be painted on the surface of a test specimen. The coating dynamically changes its relative spectral makeup or color with changes in temperature. The color changes from a reddish-brown appearance at room temperature (25 C) to a black-gray appearance at temperatures around 600 C. The color change is reversible and repeatable with temperature cycling from low to high and back to low temperatures. Detection of the spectral changes can be recorded by different sensors, including spectrometers, photodiodes, and cameras. Using a-priori information obtained through calibration experiments in known thermal environments, the color change can then be calibrated to yield accurate quantitative temperature information. Temperature information can be obtained at a point, or over an entire surface, depending on the type of equipment used for data acquisition. Because this innovation uses spectrophotometry principles of operation, rather than the current methods, which use photoluminescence principles, white light can be used for illumination rather than high-intensity short wavelength excitation. The generation of high-intensity white (or potentially filtered long wavelength light) is much easier, and is used more prevalently for photography and video technologies. In outdoor tests, the Sun can be used for short durations as an illumination source as long as the amplitude remains relatively constant. The reflected light is also much higher in intensity than the emitted light from the inefficient current methods. Having a much brighter surface allows a wider array of detection schemes and devices. Because color change is the principle of operation, the development of high-quality, lower-cost digital cameras can be used for detection, as opposed to the high-cost imagers needed for intensity measurements with the current methods. Alternative methods of detection are possible to increase the measurement sensitivity. For example, a monochrome camera can be used with an appropriate filter and a radiometric measurement of normalized intensity change that is proportional to the change coating temperature. Using different spectral regions yields different sensitivities and calibration curves for converting intensity change to temperature units. Alternatively, using a color camera, a ratio of the standard red, green, and blue outputs can be used as a self-referenced change. The blue region (less than 500 nm) does not change nearly as much as the red region (greater than 575 nm), so a ratio of color intensities will yield a calibrated temperature image. The new temperature sensor coating is easy to apply, is inexpensive, can contour complex shape surfaces, and can be a global surface measurement system based on spectrophotometry. The color change, or relative intensity change, at different colors makes the optical detection under white light illumination, and associated interpretation, much easier to measure and interpret than in the detection systems of the current methods.

Bencic, Timothy J.↗

Virtual Reality Calibration for Telerobotic Servicing

A virtual reality calibration technique of matching a virtual environment of simulated graphics models in 3-D geometry and perspective with actual camera views of the remote site task environment has been developed to enable high-fidelity preview/predictive displays with calibrated graphics overlay on live video.

error measurements↗

Hand-Eye Calibration Using Active Vision

The project described in this paper designed and implemented a hand-eye calibration method for manipulators under observation by stereo cameras. This method has been utilized on Johnson Space Center's Robonaut, and on a planetary manipulator mock-up at the Jet Propulsion Laboratory. The intent of this calibration is to improve the manipulator's hand-eye coordination.

manipulation↗

Polarimetric calibration of the Multi-Angle Imager for Aerosols (MAIA)

NASA’s Multi-Angle Imager for Aerosols (MAIA) mission, under development at the Jet Propulsion Laboratory, is designed to study the adverse health effects of different types of particulate air pollution. Planned for launch in 2023 for a 3-year mission, the MAIA satellite instrument will focus on a selected set of metropolitan target areas, where air quality monitors and health data are available. Aerosol concentration and speciation are inferred from multi-angle measurements of backscattered sunlight in 14 spectral bands from 350-2200 nm, with bands near 442, 645 and 1040 nm measuring the degree (DoLP) and angle of linear polarization (AoLP) in addition to radiance. The pushbroom camera has a ~240-km cross-track field of view with a nadir resolution of ~200 m, and is mounted onto a biaxial gimbal to provide along-track view angles within ±60°, to extend the field of regard to ±48°, and to view the instrument’s onboard calibrator (OBC) and dark target. The OBC consists of a sunlit transmissive diffuser, followed by 12 polarizers at different orientations. MAIA’s polarimetry is implemented using miniature wire grid polarizers on the focal plane array, and dual photoelastic modulators (PEMs) and achromatic quarter-wave plates to rapidly rotate the polarization. The resulting ~26-Hz intensity modulation encodes the linearly polarized and total radiance in each pixel, leaving the DoLP and AoLP insensitive to gain calibration. We report on the polarimetric calibration of the MAIA camera using a vacuum-compatible polarization state generator, consisting of a 1600W Xenon lamp, 12-inch integrating sphere, and rotating high-extinction polarizer. Mueller-matrix-based calibration coefficients for each detector pixel are derived from measurements at multiple polarizer angles, and are used to correct the measurements for instrumental polarization aberrations. Prior to flight, the calibrated MAIA camera is panned across the OBC to characterize its output, using uniform illumination with an irradiance similar to the Sun.

Werne, Thomas↗