Search NASA⌕ Search

SEARCH · Search NASA

Results for “Command and Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A Python Library for Radiance Matrix-based Simulation Control and EnergyPlus Integration

Radiance matrix-based methods enable efficient parametric simulations, allowing users to vary sky conditions, fenestration systems, and other model parameters at a minimal cost to computation. However, the steep learning curve and complex workflow hinder the widespread adoption of matrix-based methods. The frads Python library with a series of command-line tools was developed to automate the entire matrix-based simulation process, lowering entry barriers and reducing human error. Co-simulation between EnergyPlus and Radiance was also enabled using the Python library from EnergyPlus. Key Innovations • Command-line based automation of Radiance matrix-based simulation methods • Python library facilitates broader adoption of Radiance matrix-based simulation methods • Radiance EnergyPlus run-time integration enabling the modeling of advanced control systems Practical Implications The frads library, with associated command-line tools, provides practitioners with the capability to easily adopt and use Radiance matrix-based simulation methods for various daylighting, solar control, and energy-related evaluations. Frads' current form is designed for 1) users familiar with a command-line interface and 2) software developers to integrate the matrix-based methods into existing software packages.

Wang, Taoning↗

A hierarchical gray-box dynamic modeling methodology for direct-expansion cooling systems to support control stability analysis; Méthodologie de modélisation dynamique hiérarchique de type boîte grise pour les systèmes de refroidissement à détente directe afin de soutenir l'analyse de stabilité de la commande

In this paper, a gray-box dynamic modeling approach for direct-expansion cooling systems is presented. The overall approach incorporates a multi-stage training procedure that consists of 1) identification of component sub-models from quasi-steady-state performance data, 2) system model integration with estimation of refrigerant charge and 3) fine tuning of thermal capacitances of the evaporator and condenser to capture the system dynamic responses. Compared to traditional physics-based models, the proposed modeling approach has advantages including reduced engineering efforts in the model development phase, improved computational efficiency and enhanced prediction accuracy. The modeling method was validated using a 3-ton variable-speed heat pump and proved to be capable of accurately predicting the system transient behaviors over a wide range of operating conditions. The established dynamic model was then applied for control stability analysis, with a specific goal of determining a proper control execution time step. The case study results showed that the stable control execution time step could change significantly, from 3 sec to 19 sec, as the operating conditions and control settings vary, and a proper selection of the execution time step is critical to ensure stable and reliable operations.

42 ENGINEERING↗

OLED Luminaire with Panel Integrated Drivers and Advanced Controls

For this DOE award, Acuity Brands Lighting developed a novel OLED luminaire system featuring panel-integrated drivers at each individual OLED panel. The luminaire has a base station that receives user commands and performs AC/DC conversion. A power line communication (PLC) protocol is used to provide both power and digital control to each panel. A 66-panel CanvisTM luminaire using state-of-art OLED panels based on this system was successfully constructed. This is a first demonstration of such a luminaire architecture. It is also the first known implementation of this number of independently addressable nodes with a PLC protocol. This luminaire system architecture has added benefits in the flexibility of using multiple panel vendors for a given product, forward compatibility with future panels, and reduced luminaire wiring complexity and assembly time.

47 OTHER INSTRUMENTATION↗

ZFS on RBODs - Leveraging RAID Controllers for Metrics and Enclosure Management

Traditionally, the Lustre file system has relied on the ldiskfs file system with reliable RAID (Redundant Array of Independent Disks) storage underneath. As of Lustre 2.4, ZFS was added as a backend file system, with built-in software RAID, thereby removing the need of expensive RAID controllers. ZFS was designed to work with JBOD (Just a Bunch Of Disks) storage enclosures under the Solaris Operating System, which provided a rich device management system. Long time users of the Lustre file system have relied on the RAID controllers to provide metrics and enclosure monitoring and management services, with rich APIs and command line interfaces. This paper will study a hybrid approach using an advanced full featured RAID enclosure which is presented to the host as a JBOD, This RBOD (RAIDed Bunch Of Disks) allows ZFS to do the RAID protection and error correction, while the RAID controller handles management of the disks and monitors the enclosure. It was hoped that the value of the RAID controller features would offset the additional cost, and that performance would not suffer in this mode. The test results revealed that the hybrid RBOD approach did suffer reduced performance.

97 MATHEMATICS AND COMPUTING↗

Opportunities, Challenges, and Research Needs for Remote Microreactor Operations

As the nuclear industry develops new advanced reactor technologies, many companies are embracing this advancement by pursuing the development of microreactors. The term microreactor generally refers to a nuclear reactor with an operating power of 20 MW(thermal) or less. The power range of microreactors makes them appealing for many use cases, such as powering remote communities, mining sites, and military bases. Most of the microreactor designs being pursued are expected to incorporate remote facility operations into the final product. However, no framework has yet been developed to determine what remote operations systems require for reliable, resilient, and secure operation of a microreactor. Here, this work identifies the research needs for challenges that are unique to remote operations and monitoring for microreactors, specifically regarding instrumentation and control, communication methods, regulatory requirements, and operational policies. The types of commands and sensor measurements that must be transmitted between the facilities, as well as methods for verifying the trustworthiness of these signals, are assessed. This work evaluates the security, reliability, and performance requirements that must be met when considering the selection of communication hardware and protocols for use in remote operations. Also, an assessment was performed to study how remote operations fit within current regulatory requirements and what may need to be updated in regulatory policy to allow for remote operation. Finally, the operational contingencies unique to remote operations that must be in place for responses to abnormal events are identified. This paper identifies the challenges and research opportunities within the areas of importance for the design of remote operation systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Chapter 2: Commercial and Industrial Lighting Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

The Commercial and Industrial Lighting Evaluation Protocol (the protocol) describes methods to account for gross energy savings resulting from the programmatic installation of efficient lighting equipment in large populations of commercial, industrial, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. A separate Uniform Methods Project (UMP) protocol, Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol, addresses methods for evaluating savings resulting from lighting control measures such as adding time clocks, tuning energy management system commands, and adding occupancy sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digital Twin User Guide for Chelan County Public Utility District

This user manual offers a comprehensive guide for developing a Digital twin (DT) of a Kaplan turbine at Chelan County Public Utility District (Chelan PUD) using neural networks. As variable renewable generation expands, hydropower units must operate with optimal efficiency and stability. For Kaplan machines, this flexibility is achieved through coordinated control of guide vane (wicket gates) opening and runner blade pitch, which amplifies the plant’s inherent nonlinear behavior and challenges traditional physics-only modeling. The efficiency of the Kaplan turbine varies with different combinations of the guide vans (wicket gate) opening and the blade angle. Each guide van opening and blade angle has a corresponding highest efficiency point, forming a cam relationship that represents the optimal combination.The discharge of a hydraulic turbine is controlled by the opening angle of the guide vans. Therefore, for each value of head, there is a certain guide van opening and blade angle that corresponds to the highest efficiency. For a given head, different combinations of the guide van opening and blade angle have different efficiencies. Therefore, coordinate cam curves are used to describe the relationship between the wicket gate opening and blade angle with different water head. To address these challenges, the manual details a data-driven modeling and learning workflow centered on structured neural networks. The approach is designed to forecast critical operational variables—discharge flow, net head, penstock (or scroll-case) pressure, and generator electrical outputs—by leveraging real-time inputs such as the generator power control setpoint, exciter field current and field voltage, together with hydromechanical commands (e.g., gate position and, when available, runner blade-pitch angle). The neural models are trained and validated on operational data from a Kaplan unit operated by Chelan PUD, demonstrating that the structured NN architecture can learn the coupled gate–blade–electrical dynamics. The result is a robust DT that improves situational awareness and supports data-informed decision-making for Chelan PUD’s Kaplan turbine operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrified vehicle power conversion for low voltage bus

An electrified vehicle high voltage battery pack has series-connected battery units or cells combining to provide the high voltage. To power a low voltage bus (e.g., for low voltage accessories or charging a low voltage battery) in a balanced manner, a plurality of DC/DC converters each has an input coupled to a respective battery unit and the converters have respective outputs coupled in parallel to the low voltage bus. A first loop controller receives an actual bus voltage. The first controller generates a target current in response to the bus voltage adapted to regulate the actual bus voltage to a target voltage less than the high voltage. A second controller distributes the target current into a plurality of allocated current commands for respective converters according to respective states of charge of the battery units connected to the converters.

Hand, III, Michael J.↗

Opportunities and Challenges for Remote Microreactor Operations

The nuclear industry is developing new advanced reactor technologies, and many companies are embracing this advancement by pursuing the development of microreactors. The term microreactor generally refers to a nuclear reactor with an operating power of 20 MW or less. The power range of microreactors makes them appealing for many use cases, such as powering remote communities, mining sites, and military bases. Most of the microreactor designs being pursued will incorporate remote facility operations into the final product. However, no framework has yet been developed to determine what remote operations systems require for reliable, resilient, and secure operation of a microreactor. This work identifies the challenges unique to remote operations and monitoring for microreactors specifically regarding instrumentation and control, communication methods, regulatory requirements, and operational policies. The types of commands and sensor measurements that must be transmitted between the facilities as well as methods for verifying the trustworthiness of these signals are assessed. This work evaluates the security, reliability, and performance requirements that must be met when considering the selection of communication hardware and protocols for use in remote operations. Also, an assessment was performed to study how remote operations fit within current regulatory requirements and what may need to be updated in regulatory policy to allow for remote operation. Finally, the operational contingencies unique to remote operations that must be in place for response to abnormal events are identified. This paper details these challenges and research opportunities to provide a foundation for the design of remote operation systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Capability-Coordinated Frequency Control Scheme of a Virtual Power Plant with Renewable Energy Sources

Growing trends in the deployment of inverter-based renewable energy will decrease the inertia and frequency control capability of electric power systems by replacing conventional power plants; thus, the frequency of future power systems might be dynamic. This study proposes a capability-coordinated frequency control (CCFC) scheme of a virtual power plant (VPP) including adjustable-speed pumped storage hydropower (AS-PSH), a wind power plant (WPP), and an energy storage system to support the frequency nadir and reduce the steady-state error of system frequency. The CCFC scheme is based on a hierarchical-control structure in which a CCFC organises the output of local frequency control units. To support the frequency nadir, the CCFC dispatches weighted frequency errors that are proportional to the available headroom of the units; thus, the errors are forwarded separately with a system frequency error to the primary control loop of each unit and thereby arrest the frequency nadir at a higher value than a system without the CCFC. To reduce the steady-state error of the system frequency, the CCFC determines a partial active power command by additionally feeding an integrator of the CCFC with a modified frequency error that depends on the unit with the largest control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Resilient Flexible Alternating Current Transmission Systems (XFACTS)

This report summarizes the activities conducted under the DOE-OE funded project DEOE0000897, Cyber Attack Resilient Flexible AC Systems – XFACTS. Hitachi Energy (HE), in collaboration with ABB Inc. (ABB), Bonneville Power Administration (BPA), University of Illinois at Urbana-Champaign (UIUC), Iowa State University (ISU), and University of Idaho (UI) pursued the development of a system of defense for Flexible Alternating current Transmission Systems against cyber-attacks (XFACTS). A FACTS substation enhanced with XFACTS defense mechanisms will be capable of mitigating cyberattacks especially those that seek to control electrical parameters like voltage or current and interrupt the power flow in AC lines. It empowers existing FACTS controllers and associated intelligent electronic devices to detect and mitigate malicious intents to depress system voltages, destabilize power flows, trip AC circuit breakers, corrupt currents, and voltages, even if the malicious commands and the measurements have correct syntax. The XFACTS functions utilize the physics of active power electronic systems, control and protection, electric power engineering principles, and state estimation to bring more in-depth cyber defense closer to the protected FACTS substation devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning Local Volt/VAR Controllers Toward Efficient Network Operation with Stability Guarantees: Preprint

This paper considers the problem of voltage regulation in distribution network. The primary motivation is to keep voltages within pre-assigned operating limits by commanding the reactive power output of distributed energy resources (DERs) deployed in the grid. We develop a framework for developing local Volt/Var control that comprises of two main steps. In the first, exploiting historical data and for each DER, we learn a function representing desirable equilibrium points for the power network. These points approximate solutions of an Optimal Power Flow problem. In the second, we propose a control scheme for steering the network towards these favorable configurations. Theoretical conditions are derived to formally guarantee the stability of the developed control scheme and numerical simulations illustrate the effectiveness of the proposed approach.

data-driven control↗

Human-in-the-Loop Motion Control of a Two-DOF Hydraulic Backhoe Powered by the Hybrid Hydraulic Electric Architecture (HHEA)

Abstract The Hybrid Hydraulic-Electric Architecture (HHEA) combines the respective power density and control advantages of hydraulic and electric actuation to save energy for off-road vehicles. It uses a set of selectable common pressure rails to transmit the majority of power and electric actuation to modulate that power. As it is critical that off-road vehicles can perform tasks dexterously and exactly as commanded by the operator, the switchings between discrete pressure rails pose a potential challenge for smooth and precise motion. A control strategy consisting of a backstepping nominal control and least norm transition control has previously been developed to address this issue. It has been tested on 1 degree of freedom (DOF) testbeds where known trajectories were able to be tracked precisely. This paper presents the implementation of the HHEA motion control strategy on a 2-DOF backhoe operated by a human operator via a 2-DOF joystick. Unlike previous studies, the duty cycle is unknown beforehand and the decision to change pressure rails is taken in real-time. The efficacy of the motion control strategy has been validated experimentally. Several strategies to improve the user interface: control in workspace coordinates, pressure feedback, and velocity field-based task specification, have also been implemented and demonstrated to make operating the multiple DOF, HHEA actuated machine more intuitive to novice operators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Reinforcement Learning (ARL) Control of a Multi-port Resonant Converter in UAV Systems

This study presents an adaptive reinforcement learning (ARL) control framework for a multi-port resonant converter used in hybrid unmanned aerial vehicle (UAV) power systems. The converter integrates high-frequency half-bridge input ports connected to a rectified engine–generator set and a battery energy storage system, along with a semi-bridgeless active rectifier supplying the propulsion load. A deep RL agent is trained to dynamically regulate inter-port phase-shift commands in real time based on flight conditions and load power demand. The ARL controller autonomously identifies phase-shift combinations that maximize conversion efficiency while maintaining stable and coordinated power flow, even under rapidly varying operating scenarios. This data-driven approach eliminates the need for explicit system modeling or extensive manual tuning and enables coordinated control among multiple power ports without inter-port communication. Experimental results validate that the ARL based strategy achieves reliable power sharing and consistently high-efficiency operation across diverse UAV operating conditions.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Smart Inverter Twin Model for Anomaly Detection

Smart inverters connected to a communication network are vulnerable to various anomalies in the form of cyberattacks. In this paper, a self-security approach is implemented using the digital twin concept for smart inverters. The digital twin is formed using the inverter’s dynamic model. Then, the incoming setpoints are autonomously examined using the digital twin, and only the safe setpoints are engaged to the inverter’s local controller. This paper demonstrates the details of the self-security algorithm and how the inverter’s digital twin is formed. In particular, the stable and unstable operation region is experimentally verified by changing the power setpoints engaged to the local controller, using a laboratory setup including a three-phase 1.5-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative power grid emulator. The results demonstrate that the digital twin model can potentially protect inverters from abnormal operation by examining the incoming commands (new setpoints) using the inverter’s digital twin before engaging the setpoints to the local controller.

Hossen, Tareq↗

FPGA implementation of high-frequency multiple PWM for variable voltage variable frequency controller

In this paper, we present the FPGA implementation of the multiple pulse width modulation (MPWM) signal generation with repetition of data segments, applied to the variable frequency variable voltage systems and specially at to the photovoltaic water pumping system, in order to generate a signal command very easily between 10 Hz to 60 Hz with a small frequency and reduce the cost of the control system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Minimizing Ground Risk in Cellular-Connected Drone Corridors With mmWave Links

Unmanned Aircraft Systems (UASs) have been receiving significant interest and support from academia, industry, and regulatory bodies over the past decade due to their various use cases. To safely integrate UAS operations into the national airspace, particularly overpopulated regions, the risk posed to ground users, buildings, and vehicles due to unmanned aerial vehicle (UAV) flight should be minimized. This risk can be represented by a numerical metric, which we refer to in this article as the “ground risk.” Many UAS applications also depend on the presence of a reliable wireless communication link between the UAV and a control station for the transmission of UAV position, surveillance video, UAV payload commands, and other mission-related data. Such wireless communication requirements also need to be considered in the design of UAS operations. In this article, we consider both these aspects and study the design of nonintersecting trajectories for UAS operations to minimize ground risk, subject to constraints on the wireless signal strength and geometry of the trajectory, specified in terms of: 1) an enclosing cylinder within which the trajectory must lie and 2) an integrated angular change along the UAV's trajectory. The performance of a computationally expensive optimal algorithm is compared with that of a computationally faster heuristic approach within the dense urban environment of Manhattan, NY, USA. Performance evaluation using ray-tracing simulations shows that the heuristic approach performs close to the optimal algorithm at a reduced computation cost. In conclusion, this research can be utilized to make UAS operations safe and reliable and accelerate their adoption.

99 GENERAL AND MISCELLANEOUS↗

Design and validation of an MR-conditional robot for transcranial focused ultrasound surgery in infants

Purpose: Current treatment of intraventricular hemorrhage (IVH) involves cerebral shunt placement or an invasive brain surgery. Magnetic resonance-guided focused ultrasound (MRgFUS) applied to the brains of pediatric patients presents an opportunity to treat IVH in a noninvasive manner, termed “incision-less surgery.” Current clinical and research focused ultrasound systems lack the capability to perform neonatal transcranial surgeries due to either range of motion or dexterity requirements. A novel robotic system is proposed to position a focused ultrasound transducer accurately above the head of a neonatal patient inside an MRI machine to deliver the therapy. Methods: A clinical Philips Sonalleve MRgFUS system was expanded to perform transcranial treatment. A five degree-of-freedom MR-conditional robot was designed and manufactured using MR compatible materials. The robot electronics and control were integrated into existing Philips electronics and software interfaces. The user commands the position of the robot with a graphical user interface, and is presented with real-time MR imaging of the patient throughout the surgery. The robot is validated through a series of experiments that characterize accuracy, signal-to-noise ratio degeneration of an MR image as a result of the robot, MR imaging artifacts generated by the robot, and the robot’s ability to operate in a representative surgical environment inside an MR machine. Results: Experimental results show the robot responds reliably within an MR environment, has achieved 0.59 ± 0.25 mm accuracy, does not produce severe MR-imaging artifacts, has a workspace providing sufficient coverage of a neonatal brain, and can manipulate a 5 kg payload. A full system demonstration shows these characteristics apply in an application environment. Conclusions: This paper presents a comprehensive look at the process of designing and validating a new robot from concept to implementation for use in an MR environment. An MR conditional robot has been designed and manufactured to design specifications. The system has demonstrated its feasibility as a platform for MRgFUS interventions for neonatal patients. The success of the system in experimental trials suggests that it is ready to be used for validation of the transcranial intervention in animal studies.

60 APPLIED LIFE SCIENCES↗