Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparative Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Structural, negative thermal expansion and photocatalytic properties of ZrV{sub 2}O{sub 7}: a comparative study between fibers and powders

Novel ZrV{sub 2}O{sub 7} microfibers with diameters about 1–3 μm were synthesized using a sol–gel technique. For comparison, ZrV{sub 2}O{sub 7} powders were prepared by the same method. The resultant structures were studied by X-ray diffraction, field-emission scanning electron microscopy and transmission electron microscopy. The results indicated that both the pure ZrV{sub 2}O{sub 7} microfibers and powders could be synthesized by the sol–gel technique. The thermal expansion property of the as-prepared ZrV{sub 2}O{sub 7} microfibers and powders was characterized by a thermal mechanical analyzer, both the fibers with cylindrical morphology and irregular powders with average size between 100 and 200 nm showed negative thermal expansion between 150 °C and 600 °C. The photocatalytic activity of the microfibers was compared to that of powders under UV radiations. The band gap of ZrV{sub 2}O{sub 7} microfibers decreased and its absorption edge exhibited red shift. The microfibers also had a higher surface area compared with the powders, resulting in considerably higher photocatalytic characteristics. The large surface area and the enhanced photocatalytic activity of the ZrV{sub 2}O{sub 7} microfibers also offer potential applications in sensors and inorganic ion exchangers. - Graphical abstract: (a and c) SEM photos of ZrV{sub 2}O{sub 7} powders and fibers. (b and d) TEM images of ZrV{sub 2}O{sub 7} powders and fibers. (e) Thermal expansion curves of ZrV{sub 2}O{sub 7} powders and fibers. (f) Degradation curves of ZrV{sub 2}O{sub 7} powders and ZrV{sub 2}O{sub 7} fibers. - Highlights: • Novel ZrV{sub 2}O{sub 7} fibers could be synthesized using sol–gel technique. • ZrV{sub 2}O{sub 7} powders with irregular shape are also prepared for comparison. • Both ZrV{sub 2}O{sub 7} microfibers and powders exhibit negative thermal expansion property. • ZrV{sub 2}O{sub 7} microfibers show outstanding photocatalytic activity under UV irradiation. • This synthesis technique can be easily extended to many other functional fibers.

36 MATERIALS SCIENCE↗

A Randomized Phase 2 Study Comparing 2 Stereotactic Body Radiation Therapy Schedules for Medically Inoperable Patients With Stage I Peripheral Non-Small Cell Lung Cancer: NRG Oncology RTOG 0915 (NCCTG N0927)

Purpose: To compare 2 stereotactic body radiation therapy (SBRT) schedules for medically inoperable early-stage lung cancer to determine which produces the lowest rate of grade ≥3 protocol-specified adverse events (psAEs) at 1 year. Methods and Materials: Patients with biopsy-proven peripheral (≥2 cm from the central bronchial tree) T1 or T2, N0 (clinically node negative by positron emission tomography), M0 tumors were eligible. Patients were randomized to receive either 34 Gy in 1 fraction (arm 1) or 48 Gy in 4 consecutive daily fractions (arm 2). Rigorous central accreditation and quality assurance confirmed treatment per protocol guidelines. This study was designed to detect a psAEs rate >17% at a 10% significance level (1-sided) and 90% power. Secondary endpoints included rates of primary tumor control (PC), overall survival (OS), and disease-free survival (DFS) at 1 year. Designating the better of the 2 regimens was based on prespecified rules of psAEs and PC for each arm. Results: Ninety-four patients were accrued between September 2009 and March 2011. The median follow-up time was 30.2 months. Of 84 analyzable patients, 39 were in arm 1 and 45 in arm 2. Patient and tumor characteristics were balanced between arms. Four (10.3%) patients on arm 1 (95% confidence interval [CI] 2.9%-24.2%) and 6 (13.3%) patients on arm 2 (95% CI 5.1%-26.8%) experienced psAEs. The 2-year OS rate was 61.3% (95% CI 44.2%-74.6%) for arm 1 patients and 77.7% (95% CI 62.5%-87.3%) for arm 2. The 2-year DFS was 56.4% (95% CI 39.6%-70.2%) for arm 1 and 71.1% (95% CI 55.5%-82.1%) for arm 2. The 1-year PC rate was 97.0% (95% CI 84.2%-99.9%) for arm 1 and 92.7% (95% CI 80.1%-98.5%) for arm 2. Conclusions: 34 Gy in 1 fraction met the prespecified criteria and, of the 2 schedules, warrants further clinical research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparative Study of Layer Heating and Continuous Heating Methods on Prediction Accuracy of Residual Stresses in Selective Laser Melted Tube Samples

Thermal distortion and residual stresses are two important factors that affect the quality and reliability of steel parts manufactured by laser powder bed fusion (LPBF) processes. A cost-effective model for evaluation of those heat effects is needed to refine the manufacturing process and provides insights into the product design and heat treatment. In this study, the layer heating method and sophisticated track-layer scanning method were applied to simulate the thermo-mechanical response of IN625 tube parts built by LPBF. Based on the similarity of temperature field in each layer deposit, a swept mesh was constructed to perform the thermal analysis for top layer, with the rest of layers referring to the temperature by node number offsetting. A novel explicit finite element analysis code accelerated by graphics processing unit was used for the massive-element numerical analysis. The computational accuracy and efficiency of the layer heating and track-layer scanning methods were compared in detail. It is shown that layer heating method can efficiently capture the pattern of stress distribution with reasonable accuracy in stress magnitude. The grouped track-layer scanning method can predict the residual stress and strain more accurately at a higher cost (5 ~ 10×). The elastic strain distribution was compared with the measurement by X-ray diffraction, confirming the accuracy of residual stress prediction.

36 MATERIALS SCIENCE↗

Induced lattice strain in epitaxial Fe-based superconducting films on CaF{sub 2} substrates: A comparative study of the microstructures of SmFeAs(O,F), Ba(Fe,Co){sub 2}As{sub 2}, and FeTe{sub 0.5}Se{sub 0.5}

The microstructures of SmFeAs(O,F), Ba(Fe,Co){sub 2}As{sub 2}, and FeTe{sub 0.5}Se{sub 0.5} prepared on CaF{sub 2} substrates were investigated using transmission electron microscopy. The SmFeAs(O,F)/CaF{sub 2} interface is steep, without a disordered layer. By contrast, a chemical reaction occurs at the interface in the cases of Ba(Fe,Co){sub 2}As{sub 2} and FeTe{sub 0.5}Se{sub 0.5}. The reaction layers are located on opposite sides of the interface for Ba(Fe,Co){sub 2}As{sub 2} and FeTe{sub 0.5}Se{sub 0.5}. We found that the lattice distortion of the three superconducting films on the CaF{sub 2} substrates enhances the T{sub C} values compared with films prepared on oxide substrates. The origin of this lattice deformation varies depending on the superconducting material.

36 MATERIALS SCIENCE↗

A Comparative Study of Compressive Effects on the Morphology and Performance of Carbon Paper and Cloth Electrodes in Redox Flow Batteries

Compressing porous carbon electrodes is a common approach to improve flow battery performance, but the resulting impact on electrode structure, fluid dynamics, and cell performance is not well understood. Herein, microtomographic imaging, load cell testing, and flow cell diagnostics are employed to characterize how compression‐induced changes impact pressure drop, polarization, and mass‐transfer scaling. Five different compressions are tested, spanning ranges typically used in literature, for AvCarb 1071 cloth (0%, 9%, 20%, 25%, 32%) and Freudenberg H23 paper (0%, 8%, 12%, 17%, 22%). It is found that the two electrode structures have distinct responses to compression, resulting in differing optimal conditions identified for each material; specifically, the Freudenberg H23 exhibits lower combined ohmic, charge‐transfer, and mass‐transport values at 8% compression, resulting in improved electrochemical performance across all compressive values, as compared to the optimal AvCarb 1071 compression (20%). Overall, Freudenberg H23 exhibits a greater sensitivity to compression with peak electrochemical activity correlating with increased permeability, whereas AvCarb 1071 is insensitive to compressive loads but produces lower electrochemical performance. Herein, the trade‐offs of mechanical robustness on fluid‐dynamic and electrochemical performance between the two electrodes are demonstrated by the aforementioned findings, suggesting each could be used for specific operating environments.

25 ENERGY STORAGE↗

A comparative study of transport properties of monolayer graphene and AlGaN-GaN heterostructure

The electronic transport properties of monolayer graphene are presented with an Ensemble Monte Carlo method where a rejection technique is used to account for the occupancy of the final states after scattering. Acoustic and optic phonon scatterings are considered for intrinsic graphene and in addition, ionized impurity and surface roughness scatterings are considered for the case of dirty graphene. The effect of screening is considered in the ionized impurity scattering of electrons. The time dependence of drift velocity of carriers is obtained where overshoot and undershoot effects are observed for certain values of applied field and material parameters for intrinsic graphene. The field dependence of drift velocity of carriers showed negative differential resistance and disappeared as acoustic scattering becomes dominant for intrinsic graphene. The variation of electron mobility with temperature is calculated for intrinsic (suspended) and dirty monolayer graphene sheets separately and they are compared. These are also compared with the mobility of two dimensional electrons at an AlGaN/GaN heterostructure. It is observed that interface roughness may become very effective in limiting the mobility of electrons in graphene.

36 MATERIALS SCIENCE↗

SU-F-T-315: Comparative Studies of Planar Dose with Different Spatial Resolution for Head and Neck IMRT QA

Purpose: To quantitatively investigate the planar dose difference and the γ value between the reference fluence map with the 1 mm detector-to-detector distance and the other fluence maps with less spatial resolution for head and neck intensity modulated radiation (IMRT) therapy. Methods: For ten head and neck cancer patients, the IMRT quality assurance (QA) beams were generated using by the commercial radiation treatment planning system, Pinnacle3 (ver. 8.0.d Philips Medical System, Madison, WI). For each beam, ten fluence maps (detector-to-detector distance: 1 mm to 10 mm by 1 mm) were generated. The fluence maps with larger than 1 mm detector-todetector distance were interpolated using MATLAB (R2014a, the Math Works,Natick, MA) by four different interpolation Methods: for the bilinear, the cubic spline, the bicubic, and the nearest neighbor interpolation, respectively. These interpolated fluence maps were compared with the reference one using the γ value (criteria: 3%, 3 mm) and the relative dose difference. Results: As the detector-to-detector distance increases, the dose difference between the two maps increases. For the fluence map with the same resolution, the cubic spline interpolation and the bicubic interpolation are almost equally best interpolation methods while the nearest neighbor interpolation is the worst.For example, for 5 mm distance fluence maps, γ≤1 are 98.12±2.28%, 99.48±0.66%, 99.45±0.65% and 82.23±0.48% for the bilinear, the cubic spline, the bicubic, and the nearest neighbor interpolation, respectively. For 7 mm distance fluence maps, γ≤1 are 90.87±5.91%, 90.22±6.95%, 91.79±5.97% and 71.93±4.92 for the bilinear, the cubic spline, the bicubic, and the nearest neighbor interpolation, respectively. Conclusion: We recommend that the 2-dimensional detector array with high spatial resolution should be used as an IMRT QA tool and that the measured fluence maps should be interpolated using by the cubic spline interpolation or the bicubic interpolation for head and neck IMRT delivery. This work was supported by Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

60 APPLIED LIFE SCIENCES↗

A comparative study of silver- and palladium-exchanged zeolites in propylene and nitrogen oxide adsorption and desorption for cold-start applications

Here, silver and palladium ion-exchanged BEA zeolites (Si/Al = 12.5) and silver ion-exchanged ZSM-5 zeolites (Si/Al = 15) were studied for their ability to adsorb and desorb propylene and NO under simulated diesel exhaust conditions. The adsorption experiment results demonstrated the excellent ability of bare BEA zeolites to adsorb propylene, but only a small amount of NO. The presence of H 2 O inhibited the adsorption of both C 3 H 6 and NO. Ion-exchanging BEA zeolites with Ag (1.2 and 5.1 wt.% Ag/BEA) attenuated the inhibiting effect of H 2 O on C 3 H 6 adsorption, while NO storage remained inhibited. Adsorption experiments indicated that C 3 H 6 and NO competed with each other for Pd sites with C 3 H 6 showing stronger adsorption compared to NO, whereas Ag sites preferentially adsorbed C 3 H 6 . DRIFTS data indicated the formation of nitrate, formate and acetate species on Ag and Pd, while C 3 H 6 and NO adsorption was also observed on the zeolite hydroxyl groups in the absence of H 2 O. However, the C 3 H 6 and NO adsorption on the zeolite hydroxyl groups was significantly inhibited in the presence of H 2 O. Additionally, nitrosyl, acrolein and carbonate species were formed over 1.0 wt.% Pd/BEA. The effluent analysis during the temperature-programmed desorption in the DRIFTS reactor revealed that adsorbed C 3 H 6 and NO reacted during the release to form oxidation reaction byproducts. The 1.0 wt.% Pd/BEA zeolite showed the greatest oxidation ability during desorption with the majority of stored C 3 H 6 converted to CO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Comparative Study on Artificial Neural Network, Phenomenological-Based Constitutive and Modified Fields–Backofen Models to Predict Flow Stress in Ti-4Al-3V-2Mo-2Fe Alloy

The flow curve was obtained from the superplastic tensile tests in the temperature range of 1033-1153 K and strain rate range of 0.001-0.1 s{sup −1}. Results showed that strain hardening (SH) was insensitive to deformation parameter variation but with the nature of material, while stable state (SS) and dynamic softening (DS) were significantly associated with a thermal activated process. The occurrence of secondary hardening and softening was attributed to discontinuous dynamic recrystallization. And the generation of necklace microstructure at grain boundaries was caused by bulging. Based on the experimental data, the artificial neural network (ANN), phenomenological-based constitutive (PBC) and modified Fields–Backofen (MFB) models were developed, and their predictability and adaptability for the description of the flow behavior during hot processing were evaluated by analyzing the employed standard statistical parameters. Comparatively, ANN model is capable of tracing the complex flow behavior including SH, SS and DS substages. Concerning PBC model, it can not only predict flow stress with satisfactory accuracy, but also represent the flow trend with the larger strain. MFB model adapts well to the flow curve with a broad SH region without DS effect.

36 MATERIALS SCIENCE↗

Comparative Study of the Geometric Effects on Fracture Behaviors of Side-Grooved and Plain-Sided Compact Tension Specimens

This paper investigates the fracture response and crack-tip constraint of two typical compact tension specimens. They are pre-cracked plain-sided and side-grooved specimens. In order to clarify the significant effects of geometric parameters on the crack-tip stress fields, an extensive series of detailed 3D elastic–plastic finite element analyses have been carried out. Taking the standard ratio of geometric parameters as a basis, several non-standard geometric parameters are adopted in the calculation for comparison, including specimen thickness, width, crack length. Accordingly, the variation of local J-integral and crack-tip opening displacement have been vigorously investigated over the crack front. Most importantly, the crack-tip stress fields are analyzed in detail with the emphasis on the stress triaxiality and opening mode stress. Furthermore, the crack-tip plastic strain and deformation are compared under small-scale yielding and large-scale yielding between plain-sided and side-grooved specimens, and the constraint parameter Q is employed to explain the distribution of the near-tip plastic strain. Through the vigorous research work, the variation of fracture behavior caused by geometric parameters is reasonably explained and understood.

36 MATERIALS SCIENCE↗

Comparative study and test on a two-body wave energy point absorber under various constraints.

Power generation and motion response of the floating wave energy converters is of great importance in the research topic of ocean energy harvesting. As a classic design for harvesting the ocean wave energy, the wave energy point absorber is commonly studied theoretically using the idealized 1DOF and 2DOF dynamic model based on the number of the free body within the system. Whereas the mooring system is usually ignored and only the heave motion is considered. In this paper, a point absorber is designed prototyped and tested in a water tank under three different constrains, the single body 1DOF, the two body 2DOF and the two body 6DOF. All the designs and configurations are presented in detail. Numerical analysis is conducted and presented as well to help understand the test results deeper. The test results indicate that the two body system can be tuned to match with the wave excitation and achieve higher energy absorption. In addition, the compared results between the 2DOF configuration and 6DOF configuration show that the classic 2DOF dynamic model is able to predict the performance of the point absorber with mooring well.

Li, Xiaofan↗

Comparative Study of Barotrauma Risk during Fish Passage through Kaplan Turbines

Rapid pressure changes in hydroelectric turbine flows can cause barotrauma that can be hazardous to the passage of fish, in particular migratory juvenile salmonids. Although numerous laboratory tests have evaluated the effect of rapid decompression in fish species of relevance, numerical modeling studies offer the advantage of predicting, for new turbine designs, the potential risks of mortality and injury from rapid pressure change during turbine passage. However, rapid pressure change is only one of several hydraulic risks encountered by fish during turbine passage in addition to blade strike, shear, and turbulence. To better understand the role of rapid pressure changes, the present work focuses on the application of a computational fluid dynamics based method for evaluating the risk of pressure-related mortality to fish passing through an early 1960s era original hydroelectric Kaplan turbine at Wanapum Dam (Columbia River, Washington), and a modern advanced Kaplan turbine installed in 2005. The results show that the modeling approach acceptably reproduced the nadir pressure distributions compared to field data previously collected at the site using an autonomous sensor. Our findings show that the new advanced-design unit performs better, in terms of reduced barotrauma risk to fish from exposure to low pressures, than the original turbine unit. The outcomes allow for comparative analyses of turbine designs and operations prior to installation, an advantage that can potentially be integrated in the process of designing new turbine units to achieve superior environmental performance. Overall, the results show that modern turbine designs can achieve the multiple objectives of increasing power generation, lowering cavitation potential, and reducing barotrauma risks to passing fish.

13 HYDRO ENERGY↗

Mechanical and physical properties of inorganic polymer cement made of iron-rich laterite and lateritic clay: A comparative study

In this work, two different laterites (iron contents of 13.07 and 49.34 wt%, respectively, for lateritic clay, LAC, and iron-rich laterite, LAI) were selected and calcined at 600 °C. The obtained calcined laterites, namely LAI600 and LAC600, were separately mixed with an alkaline solution (silicate modulus of 1.35) or an acidic solution (phosphoric acid solution at pH ≤ 2) for the synthesis of inorganic polymer products. The fabricated products were cured at 20 °C (ambient) and 40 °C (oven). The obtained results showed that the compressive strength of each series of alkaline-based inorganic polymer binder increased with ageing time (7 and 28 days) for room temperature curing, while the reverse trend was noted for oven-cured specimens. The best mechanical performance was obtained when using a phosphoric acid solution, 38 and 52 ± 1 MPa; 62 and 65 ± 1 MPa at 28 days for LAC and LAI respectively. It appeared that a higher iron content within the laterite contributed to an increase in the compressive strength under acidic conditions (LAI (59 MPa) > LAC (48 MPa)) compared to the behavior obtained under alkaline conditions (LAI (6 MPa) < LAC (29 MPa)). Accordingly, the acidic products exhibited a dense structure (with lower porosity) and contained amorphous iron/aluminium phosphate phases such as berlinite (FePO{sub 4}), iron hydrogen phosphate hydrate (Fe{sub 3}H{sub 15}(PO{sub 4}){sub 8·}4H{sub 2}O), ferrowyllieite (AlFe{sub 2}Na{sub 2}(PO{sub 4}){sub 3}) and sodium iron phosphate (Na{sub 3}Fe{sub 2}(PO{sub 4}){sub 3}) arising from the alteration of iron minerals in an acidic medium, confirmed by Mössbauer spectroscopy and electron paramagnetic resonance spectroscopy.

36 MATERIALS SCIENCE↗

A comparative study of quantitative microsegregation analyses performed during the solidification of the Ni-base superalloy CMSX-10

Quantitative microsegregation analyses were systematically carried out during the solidification of the Ni-base superalloy CMSX-10 to clarify the methodological effect on the quantification of microsegregation and to fully understand the solidification microstructure. Three experimental techniques, namely, mushy zone quenching (MZQ), planar directional solidification followed by quenching (PDSQ), and random sampling (RS), were implemented for the analysis of microsegregation tendency and the magnitude of solute elements by electron probe microanalysis. The microprobe data and the calculation results of the diffusion field ahead of the solid/liquid (S/L) interface of PDSQ samples revealed that the liquid composition at the S/L interface is significantly influenced by quenching. By applying the PDSQ technique, it was also found that the partition coefficients of all solute elements do not change appreciably during the solidification of primary γ. All three techniques could reasonably predict the segregation behavior of most solute elements. Nevertheless, the RS approach has a tendency to overestimate the magnitude of segregation for most solute elements when compared to the MZQ and PDSQ techniques. Moreover, the segregation direction of Cr and Mo predicted by the RS approach was found to be opposite from the results obtained by the MZQ and PDSQ techniques. This conflicting segregation behavior of Cr and Mo was discussed intensively. It was shown that the formation of Cr-rich areas near the γ/γ′ eutectic in various Ni-base superalloys, including the CMSX-10 alloy, could be successfully explained by the results of microprobe analysis performed on a sample quenched during the planar directional solidification of γ/γ′ eutectic. - Highlights: • Methodological effect on the quantification of microsegregation was clarified. • The liquid composition at the S/L interface was influenced by quenching. • The segregation direction of Cr varied depending on the experimental techniques. • Cr and Mo segregation in Ni-base superalloys was fully understood.

36 MATERIALS SCIENCE↗

Constitutive Modeling of High-Temperature Flow Stress of Armor Steel in Ballistic Applications: A Comparative Study

Armox 500T is one of the armor grade steels extensively used as armor against bullet penetration in ballistic applications. In such applications, the material undergoes plastic deformation at large strain rates (10{sup 3} s{sup −1}) at temperatures of the order of 673-1373 K. In the present work, an attempt has been made to predict strain rate and temperature-dependent flow behavior of Armox 500T steel through physical-based model like modified Zerilli–Armstrong (M-ZA) and phenomenological-based models like Cowper Symonds (CS), modified Johnson–Cook (M-JC), Arrhenius (Arr.) and Khan–Huang–Liang (KHL) constitutive material model. Isothermal uniaxial compression tests at low strain rates (10{sup −3}-10{sup −1} s{sup −1}) and dynamic compression tests at high strain rates (600-3000 s{sup −1}) in the temperatures range of 673-1373 K have been carried out to determine constitutive material model parameters. In addition, an artificial neural network (ANN) model that works on multilayer perceptron (MLP) based back propagation neural network (BPNN) has also been developed. The results from all these models have been compared in terms of three statistical parameters namely correlation coefficient (R), mean absolute percent error (MAPE) and its standard deviation (Δ). The results revealed that M-JC model shows highest correlation coefficient and lowest average absolute error. Further, ANN model prediction has the highest accuracy with R = 0.999 and MAPE = 1.052.

36 MATERIALS SCIENCE↗

Power distribution and BER in indoor VLC with PPM based modulation schemes: a comparative study

Visible light communication (VLC) uses an intensity-modulation and direct-detection scheme to transmit data. The light source utilized in VLC structures is constantly switched on and off rapidly, resulting in flickering. Furthermore, most of illumination systems exclude dimming support to permit customers to dim the light source to the desired stage. Therefore, the modulation scheme for information transmission in VLC should consist of flicker mitigation and dimming manage abilities. Double inverse pulse position modulation (DIPPM), sub-carrier pulse position modulation (SC-L-PPM), and M-ary variable pulse position modulation (M-VPPM) are recommended for minimizing the flicker issues and supporting an excessive degree of dimming for VLC systems. In this paper, a comparison is introduced between DIPPM, SC-L-PPM, and M-VPPM according to error performance and bit rate. In addition, a simulation is carried out to measure the optical power distribution for a LED lamp in an indoor room topology for each modulation technique. The obtained results indicated that SC-L-PPM is the best choice regarding the bit error rate (BER) and optical power distribution compared to the other two schemes. A 10{sup −6} BER is achieved with a very low power requirement at L = 8, while a remarkable power distribution of 1.5–6.5 dBm is observed from 3 × 5 × 5 m{sup 3} room corners to the center, respectively. According to the bit rate, it is noticed that, M-VPPM is the most efficient one compared to the two other schemes. It achieves 2.3 × 10{sup 7} bps at a signal to noise ratio (SNR) of 22 dB and M = 8.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative study of optical and structural properties of electrospun 1-dimensional CaYAl{sub 3}O{sub 7}:Eu{sup 3+} nanofibers and bulk phosphor

We report the optical and structural studies of Eu{sup 3+}-doped 1-dimensional CaYAl{sub 3}O{sub 7} nano-fiber phosphor. CaYAl{sub 3}O{sub 7}:Eu{sup 3+} phosphors were synthesized by electrospinning technique and the pristine nano-fibers were annealed at 900 °C to form well crystallized uniform fibers. Under ultraviolet excitation, the CaYAl{sub 3}O{sub 7}:Eu{sup 3+} exhibited red emission, due to transitions in the 4f states of Eu{sup 3+}. In order to explore the difference between the quantum efficiency of nano-fiber and bulk CaYAl{sub 3}O{sub 7}:Eu{sup 3+} phosphor, detailed structural and optical analyses were carried out. The structural analysis of the CaYAl{sub 3}O{sub 7}:Eu{sup 3+} nano-fibers indicates that the structural environment surrounding the dopant Eu{sup 3+} ion was more unstable in nano-fiber when compared to a bulk sample. Decay curves for both the samples when fitted with double exponential decay model indicate that the nano-fiber has shorter decay time, arising from the larger contribution from the non-radiative decay, due to defect levels introduced in the host lattice. - Highlights: • Synthesis of red nano-phosphor through electrospinning • Luminescence properties of bulk and nano-phosphors are compared. • Inferior emission intensity of the nano-phosphor is analyzed using MEM. • Charge cloud around nano-phosphor was found to be oblique.

36 MATERIALS SCIENCE↗

A comparative study of LaBr{sub 3}(Ce{sup 3+}) and CeBr{sub 3} based gamma-ray spectrometers for planetary remote sensing applications

The recent availability of large volume cerium bromide crystals raises the possibility of substantially improving gamma-ray spectrometer limiting flux sensitivities over current systems based on the lanthanum tri-halides, e.g., lanthanum bromide and lanthanum chloride, especially for remote sensing, low-level counting applications or any type of measurement characterized by poor signal to noise ratios. The Russian Space Research Institute has developed and manufactured a highly sensitive gamma-ray spectrometer for remote sensing observations of the planet Mercury from the Mercury Polar Orbiter (MPO), which forms part of ESA’s BepiColombo mission. The Flight Model (FM) gamma-ray spectrometer is based on a 3-in. single crystal of LaBr{sub 3}(Ce{sup 3+}) produced in a separate crystal development programme specifically for this mission. During the spectrometers development, manufacturing, and qualification phases, large crystals of CeBr{sub 3} became available in a subsequent phase of the same crystal development programme. Consequently, the Flight Spare Model (FSM) gamma-ray spectrometer was retrofitted with a 3-in. CeBr{sub 3} crystal and qualified for space. Except for the crystals, the two systems are essentially identical. In this paper, we report on a comparative assessment of the two systems, in terms of their respective spectral properties, as well as their suitability for use in planetary mission with respect to radiation tolerance and their propensity for activation. We also contrast their performance with a Ge detector representative of that flown on MESSENGER and show that: (a) both LaBr{sub 3}(Ce{sup 3+}) and CeBr{sub 3} provide superior detection systems over HPGe in the context of minimally resourced spacecraft and (b) CeBr{sub 3} is a more attractive system than LaBr{sub 3}(Ce{sup 3+}) in terms of sensitivities at lower gamma fluxes. Based on the tests, the FM has now been replaced by the FSM on the BepiColombo spacecraft. Thus, CeBr{sub 3} now forms the central gamma-ray detection element on the MPO spacecraft.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗