Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contaminants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Shuttle payload integration - Contamination aspects

As part of the development of the Space Shuttle, a payload integration system has been established. This integration system or process encompasses several technical disciplines, one of which is concerned with the control of molecular and particulate contamination. Specific integration procedures and documentation have evolved that reflect the incorporation of payload/Space Transportation System contamination requirements and capabilities. Of the 38 payloads in the payload integration system currently, about 20% are considered sensitive to contamination in that special precautions must be taken to ensure that contamination from the Space Shuttle Orbiter does not impair payload function. Most of these payload requirements have been satisfied by the incorporation of controlled ground operations discipline and installation of a payload bay liner, which isolates the payload from the Orbiter systems. Some payloads, however, provide covers for sensitive payload instrumentation.

Jacobs, S.↗

Abatement of gaseous and particulate contamination in a space instrument

Methods to prevent the ingestion of external contaminants into the instrument and to limit the effect of the self-generated contaminants during ground, launch, orbiting and landing phases of flight were investigated. It is proposed that a positive pressure and purging flow of clean gas inside the instrument be maintained while on the ground, during launch, and for a period of time in orbit. The pressure to be maintained and the required purging flow are examined in terms of the effectiveness in preventing gaseous and particulate contaminants ingestion and the abatement of the self-generated contaminants. Considerations have been given to the venting requirements for the structural integrity of the instrument during launch, the limitations on the volume and the pressure of the purging gas to be carried along in orbit, and the required venting area is established based on the internal volume of the instrument, the allowable pressure differential, and the rate of external pressure change during launch. Previously announced in STAR as N83-23350

Scialdone, J. J.↗

Optical contamination on the Atmosphere Explorer-E satellite

Atmospheric optical emission measurements by the Visible Airglow Experiment (VAE) on board the Atmosphere Explorer (AE-C, D and E) satellites have been analyzed and found to be contaminated at low altitudes. The contamination maximizes in the forward direction along the spacecraft velocity and is sensitive to the composition and density of the ambient atmosphere. Analysis at two different wavelengths suggests that the contamination is likely to have a diffuse band spectrum which is brighter toward the red. Some unknown processes which involve satellite surface materials and the incoming ambient particles are believed to be responsible for the contamination. A simulation model is presented here to account for the observed angular dependence.

Yee, J. H.↗

Maintenance of contamination sensitive surfaces on board long-term space vehicles

In the current age, highly sensitive instruments are being flown on spacecraft, and questions of contamination have become important. The present investigation is concerned with the available approaches which can provide long-term protection for contamination sensitive surfaces. Aspects and sources of spacecraft contamination are examined, taking into account materials outgassing, particulates, propulsion system interaction, overboard venting, man-made and cosmic debris, and atomic oxygen/ambient atmosphere interaction. Suitable protection approaches provided by current technology are discussed, giving attention to aperture covers, a possibility for a retractable cover design, gaseous purges, options for prolonging the lifetime of the thermal control system, and plume shields. Some new possibilities considered are related to an early warning system for excessive amounts of contamination, a molecular/wake shield, and the use of atomic oxygen.

Phillips, A.↗

Shuttle on-orbit contamination and environmental effects

Ensuring the compatibility of the space shuttle system with payloads and payload measurements is discussed. An extensive set of quantitative requirements and goals was developed and implemented by the space shuttle program management. The performance of the Shuttle system as measured by these requirements and goals was assessed partly through the use of the induced environment contamination monitor on Shuttle flights 2, 3, and 4. Contamination levels are low and generally within the requirements and goals established. Additional data from near-term payloads and already planned contamination measurements will complete the environment definition and allow for the development of contamination avoidance procedures as necessary for any payload.

Leger, L. J.↗

A review of contamination issues associated with an orbiting Space Station external environment

Techniques for measuring, modeling, and limiting the effluent contamination of external spacecraft and instrument surfaces are reviewed, with an emphasis on their application to the Space Station. The major factors addressed by contamination studies are outlined; typical contamination sources are characterized; the critical measurement parameters are defined (molecular column density, background spectral intensity from UV to IR, particle size and velocity distribution, molecular deposition on ambient and cryogenic surfaces, molecular return flux for gaseous species, particulate deposition on surfaces, and optical-surface degradation); and measurement instrumentation is described. Contamination limits for quiescent operation periods of the Space Station are proposed, including column density 10 to the 11th/sq cm for H2O + CO2, 10 to the 13th/sq cm for O2 + N2, and 10 to the 10th/sq cm for other species; particle release no greater than 15-micron particle/orbit/0.00001 sr FOV for a 1-m telescope, and surface deposition 4 pg/sq cm sec for 298-K surfaces and 10 pg/sq cm sec for 4-K surfaces.

Smith, A. C.↗

Airborne trace contaminants of possible interest in CELSS

One design goal of Closed Ecological Life Support Systems (CELSS) for long duration space missions is to maintain an atmosphere which is healthy for all the desirable biological species and not deleterious to any of the mechanical components in that atmosphere. CELESS design must take into account the interactions of at least six major components; (1) humans and animals, (2) higher plants, (3) microalgae, (4) bacteria and fungi, (5) the waste processing system, and (6) other mechanical systems. Each of these major components can be both a source and a target of airborne trace contaminants in a CELSS. A range of possible airborne trace contaminants is discussed within a chemical classification scheme. These contaminants are analyzed with respect to their probable sources among the six major components and their potential effects on those components. Data on airborne chemical contaminants detected in shuttle missions is presented along with this analysis. The observed concentrations of several classes of compounds, including hydrocarbons, halocarbons, halosilanes, amines and nitrogen oxides, are considered with respect to the problems which they present to CELSS.

Garavelli, J. S.↗

Sr, Nd, and Pb isotopes in Proterozoic intrusives astride the Grenville Front in Labrador - Implications for crustal contamination and basement mapping

Trace element and Pb, Sr, and Nd isotopic compositions of anorthosites and related rocks, and of younger mafic dikes from Harp Lake and Mealy Mountains in Labrador, Canada are estimated and compared. The effects of crustal component contaminants on the isotopic compositions of the dikes are investigated. The correlation between the isotopic data and the crustal contamination model is studied. It is observed that for Harp Lake the initial Sr ratios are higher and the Nd values are lower than Mealy samples, and the data do not correspond to the crustal contamination model; however, the Pb isotope data favor a crustal contamination model. It is noted that the Labrador segment of the Grenville Front appears to coincide with the southern margin of the Archean North Atlantic craton, and may represent a pre mid-Proterozoic suture.

Ashwal, L. D.↗

Effects of varying environmental parameters on trace contaminant concentrations in the NASA Space Station Reference Configuration

An evaluation is made of the NASA Space Station Reference Configuration trace contaminant production and depletion level effects of CO2, O2, humidity, temperature, and pressure variations, on the basis of a computer model of the Reference Configuration's chemical reactions and physical processes as functions of time. The effects of changes in the initial concentrations of such contaminants as nonmethane hydrocarbons and nitrogen oxides are also examined, and these are found to result in more significant changes in the concentration levels of trace contaminants than pressure and humidity variations. O2 and CO2 changes are found to have negligible effects on trace contaminant concentrations.

Brewer, Dana A.↗

A simulation model for the analysis of Space Station gas-phase trace contaminants

A simulation model for the analysis of gas-phase trace contaminants in the cabin air of the NASA Space Station Reference Configuration was developed at the NASA Langley Research Center. The model predicts changes in trace contaminant concentrations from both physical and chemical sources and sinks as a function of time. Simulations were performed in which values for relative humidity, temperature, radiation intensity, pressure, and initial species concentrations were constrained to values for these parameters measured and modeled in the continental tropics at the earth's surface. Species concentrations simulated using the model compared favorably with concentrations in the continental tropics which demonstrated that the chemical mechanism in the trace contaminant model approximates changes in atmospheric species concentrations. The sensitivity of initial species concentrations to producing changes in additional species concentrations was also assessed. Results from the model indicated that chemical reactions will be important in determining the composition of cabin air in the Space Station. It is anticipated that the trace contaminant model will be useful in assessing the impact of experiments and commercial operations on the composition of the cabin air in the Space Station.

Brewer, Dana A.↗

Contamination control of the space shuttle Orbiter crew compartment

Effective contamination control as applied to manned space flight environments is a discipline characterized and controlled by many parameters. An introduction is given to issues involving Orbiter crew compartment contamination control. An effective ground processing contamination control program is an essential building block to a successful shuttle mission. Personnel are required to don cleanroom-grade clothing ensembles before entering the crew compartment and follow cleanroom rules and regulations. Prior to crew compartment entry, materials and equipment must be checked by an orbiter integrity clerk stationed outside the white-room entrance for compliance to program requirements. Analysis and source identification of crew compartment debris studies have been going on for two years. The objective of these studies is to determine and identify particulate generating materials and activities in the crew compartment. Results show a wide spectrum of many different types of materials. When source identification is made, corrective action is implemented to minimize or curtail further contaminate generation.

Bartelson, Donald W.↗

Contamination control approach for the Extreme Ultraviolet Explorer satellite instrumentation

The Extreme Ultraviolet Explorer will perform an all-sky survey and spectroscopic observations over the wavelength range 80-900A. Hydrocarbon and particulate contamination will potentially affect the throughput and signal to noise ratio of the signal detected by the instruments. A witness sample program is here used to investigate and monitor the effects of specific contaminants on EUV reflectivity. Witness samples were intentionally contaminated with thin layers of pump oil. An oil layer 150 A thick was applied and found to evaporate over 8 hours. The EUV reflectivity and imaging properties were then measured and found to be acceptable for grazing angles between 5 and 30 deg. In a second test, layers 500 A thick were deposited and then allowed to evaporate in vacuum; once the oil had evaporated to at least 350 A, the final sample reflectivity was degraded less than 10 percent, but the image was degraded severely by scattering. An outline of the contamination control program is also presented.

Mrowka, Stan↗

Effects of contamination on riblet performance

Thin-element polymeric film riblet surfacing materials previously shown to behave similarly to v-groove riblets in the reduction of aerodynamic drag have been tested to ascertain the effects of groove contamination. Three different levels of contamination were simulated for each of two kinds of contamination. Such contaminants as oil drops and condensates have no significant effect on drag reduction. Atmospheric particulates may, however, degrade riblet performance.

Lazos, Barry S.↗

An Auger electron spectroscopy study of surface-preparation contaminants

There are many cleaning techniques that are presently being employed for surface preparation of materials that are subsequently exposed to ultrahigh vacuum (UHV). Unfortunately, there are virtually no comparative measurements which establish the residual contaminant level of each method. In this report, eleven different cleaning methods, ranging from only detergent cleaning to electrochemical polishing, were applied to identical samples of 347 stainless steel. Two surface conditions, a standard machined surface and a mechanically polished surface, were studied. Auger electron spectroscopy (AES) within a UHV environment was then used to detect the types of contaminants and the magnitudes found on the sample surfaces. It was found that the electrochemical polishing gave the least contaminated surface of all metals studied and that mechanically polished surfaces were significantly cleaner than the as-machined surfaces for any given cleaning method. Furthermore, it was also found that the residual contaminations left by methanol, ethanol, isopropyl alcohol, acetone, and freon finishing rinses are almost the same.

Wu, D.↗

A flight experiment to determine GPS photochemical contamination accumulation rates

It was recently suggested that photochemically deposited contamination, originating from volatiles outgassed by a spacecraft, may be responsible for the anomalous degradation in power seen on the GPS Block 1 vehicles. In an attempt to confirm, or deny, the photochemical deposition rates predicted, a study was undertaken to design a flight experiment to be incorporated on the GPS vehicles currently in production. The objective was to develop an inexpensive, light weight instrument package that would give information on the contamination levels within a few months of launch. Three types of apparatus were studied, Quartz Crystal Microbalances, (QCM's), modified solar cells, and calorimeters. A calorimeter was selected due primarily to its impact on the production schedule of the GPS vehicles. An analysis of the sensitivity of the final design is compared to the predicted contamination accumulation rates in order to determine how long after launch it will take the experiment to show the effects of photochemical contamination.

Tribble, A. C.↗

Contamination monitoring approaches for EUV space optics

Data from contaminant-induced UV optics degradation studies and particulate models are used here to develop end-of-service-life instrument contamination requirements which are very stringent but achievable. The budget is divided into allocations for each phase of hardware processing. Optical and nonoptical hardware are monitored for particulate and molecular contamination during initial cleaning and baking, assembly, test, and calibration phases. The measured contamination levels are compared to the requirements developed for each phase to provide confidence that the required end-of-life levels will be met.

Ray, David C.↗

Modeling of internal contaminant deposition on a cold instrument sensor

A model is developed to predict the deposition of contaminants on the CCD sensors of the Wide Field Planetary Camera to determine expected performance parameters. Contaminant deposition due to internal instrument sources is considered as is the mechanism of transport to the CCDs themselves. The Contamination Analysis Program (CAP) model considers deposition and reemission kinetics, nodal containment sources, and internodal shape factors related to line-of-sight transport. Indirect transport is also accounted for in the CAP model by considering the effect of diffuse reflection at internodal exchanges. The effective total transport factors for each node-to-node exchange is precalculated to reduce the effective number of nodes and reducing run time of the CAP program. The method is applied to four distinct conditions and is found to be suitable for the analysis of internal self-contamination. Cold traps, venting, and vacuumlike design are factors which are found to be important for cold-sensitive sensors.

Barengoltz, Jack B.↗

Fluorescence Imaging Reveals Surface Contamination

In technique to detect surface contamination, object inspected illuminated by ultraviolet light to make contaminants fluoresce; low-light-level video camera views fluorescence. Image-processing techniques quantify distribution of contaminants. If fluorescence of material expected to contaminate surface is not intense, tagged with low concentration of dye.

Schirato, Richard↗