Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cooling effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Visualization techniques to experimentally model flow and heat transfer in turbine and aircraft flow passages

Increased attention to fuel economy and increased thrust requirements have increased the demand for higher aircraft gas turbine engine efficiency through the use of higher turbine inlet temperatures. These higher temperatures increase the importance of understanding the heat transfer patterns which occur throughout the turbine passages. It is often necessary to use a special coating or some form of cooling to maintain metal temperatures at a level which the metal can withstand for long periods of time. Effective cooling schemes can result in significant fuel savings through higher allowable turbine inlet temperatures and can increase engine life. Before proceeding with the development of any new turbine it is economically desirable to create both mathematical and experimental models to study and predict flow characteristics and temperature distributions. Some of the methods are described used to physically model heat transfer patterns, cooling schemes, and other complex flow patterns associated with turbine and aircraft passages.

Russell, Louis M.↗

Hydrogen film cooling investigation

Effects of flow turning, flow acceleration, and supersonic flow on film cooling were determined experimentally and correlated in terms of an entrainment film cooling model. Experiments were conducted using thin walled metal test sections, hot nitrogen mainstream gas, and ambient hydrogen or nitrogen as film coolants. The entrainment film cooling model relates film cooling effectiveness to the amount of mainstream gases entrained with the film coolant in a mixing layer. The experimental apparatus and the analytical model used are described in detail and correlations for the entrainment fraction and film coolant-to-wall heat transfer coefficient are presented.

Rousar, D. C.↗

Effect of endwall cooling on secondary flows in turbine stator vanes

An experimental investigation was performed to determine the effect of endwall cooling on the secondary flow behavior and the aerodynamic performance of a core-turbine stator vane. The investigation was conducted in a cold-air, full-annular cascade, where three-dimensional effects could be obtained. In one configuration, the cooling holes were oriented so that the coolant was injected in line with the inviscid streamline direction. In another configuration, the coolant was injected at an angle of 15 deg to the inviscid streamline direction and oriented toward the vane pressure surface. Total-pressure surveys were taken downstream of the stator vanes over a range of cooling flows. Changes in the total-pressure contours downstream of the vanes were used to obtain the effect of endwall cooling on the secondary flows in the stator. Comparisons are made between the two cooled-endwall configurations and with the results obtained previously for solid (uncooled) endwalls.

Goldman, L. J.↗

Extreme hydroclimates amplify the biophysical effects of advanced green-up in temperate China

Vegetation phenology modulates climate by altering energy and water exchange between the land and atmosphere. However, how extreme hydroclimatic conditions modify these phenology-climate feedbacks is still poorly understood. Here, in this study, we used a land–atmosphere-coupled Weather Research and Forecasting model to explore the impacts of advanced green-up on air temperature under different hydroclimate conditions across temperate China and to Mechanistic analysis elucidate the underlying biophysical mechanisms. By imposing a 14-day earlier green-up in line with recent satellite observations, we found that under mean climate conditions, an earlier leaf-out induces immediate surface cooling of 0.14 °C during green-up and a lagging 0.02 °C warming during senescence averaged for temperate China. Extremely humid conditions amplify the cooling effects to 0.18 °C during green-up, extending this cooling into the senescence period. Conversely, under extremely arid conditions, earlier green-up cools air temperature by 0.09 °C, and amplified senescence warming to 0.16 °C. Mechanism analysis revealed that evapotranspiration-dominated non-radiative processes drive immediate cooling during green-up while radiation and circulation process dominates the delayed but opposite warming/cooling effects during senescence in extremely arid/humid hydroclimates. Given the projected continuation of warming trends and increased frequency of extreme climatic events, it is imperative to incorporate the biophysical effects of vegetation phenology into local climate adaptation strategies.

54 ENVIRONMENTAL SCIENCES↗

Thermal Management for a Novel Non-Heavy Rare-Earth Interior Permanent Magnet Machine

The work presents a thermal management solution for a novel non-heavy rare-earth permanent magnet machine being developed at Oak Ridge National Laboratory. The motor has been designed to minimize losses while maximizing performance for a range of speeds and power ratings. The novel motor design reduces rare-earth magnet usage, thereby avoiding supply chain issues. The motor component heat losses are established for operating windows and desired performance. These heat losses, along with windage losses, are being used to develop cooling solutions for different components of this machine. A novel thermal management solution for stators and rotors has been developed, and progress is presented in this paper. The stator cooling is achieved with the help of water-ethylene glycol flowing over the finned aluminum stator jacket, and rotor cooling with automatic transmission fluid passing through novel channels designed in the rotor laminations. The attempt is to establish effective cooling of the stator winding, laminations, and rotor magnets. A 3D conjugate heat transfer model has been developed for overall thermal analysis to establish a down- selected thermal management solution for the machine. The model, in addition to estimated component heat losses, includes windage losses and its impact on rotor and stator cooling. Overall, the work presents a workable thermal solution for the interior permanent magnet machine with potential for further improvements. Future work will involve establishing end winding and refinement of other end parts of the machine with the aim of establishing a robust thermal management solution. The work will also focus on different shapes (e.g., round, non-round, presence of wedges) of rotor-stator gaps and investigate windage losses and their impact on thermal management for higher rotational speeds for the machine.

30 DIRECT ENERGY CONVERSION↗

Cosmic Reionization on Computers: Baryonic Effects on Halo Concentrations during the Epoch of Reionization

Baryons both increase halo concentration through adiabatic contraction and expel mass through feedback processes. However, it is not well understood how the radiation fields prevalent during the epoch of reionization affect the evolution of concentration in dark matter halos. We investigate how baryonic physics during the epoch of reionization modify the structure of dark matter halos in the Cosmic Reionization On Computers (CROC) simulations. We use two different measures of halo concentration to quantify the effects. We compare concentrations of halos matched between full-physics simulations and dark-matter-only simulations with identical initial conditions between 5 ≤ z ≤ 9. Baryons in full-physics simulations do pull matter toward the center, increasing the maximum circular velocity compared to dark-matter-only simulations. However, their overall effects are much less than if all the baryons were simply centrally concentrated indicating that heating processes efficiently counteract cooling effects. Finally, we show that the baryonic effects on halo concentrations at z ≈ 5 are relatively insensitive to environmental variations of reionization history. These results are pertinent to models of galaxy–halo connection during the epoch of reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

Current Pulses Momentarily Enhance Thermoelectric Cooling

The rates of cooling afforded by thermoelectric (Peltier) devices can be increased for short times by applying pulses of electric current greater than the currents that yield maximum steady-state cooling. It has been proposed to utilize such momentary enhancements of cooling in applications in which diode lasers and other semiconductor devices are required to operate for times of the order of milliseconds at temperatures too low to be easily obtainable in the steady state. In a typical contemplated application, a semiconductor device would be in contact with the final (coldest) somewhat taller stage of a multistage thermoelectric cooler. Steady current would be applied to the stages to produce steady cooling. Pulsed current would then be applied, enhancing the cooling of the top stage momentarily. The principles of operation are straightforward: In a thermoelectric device, the cooling occurs only at a junction at one end of the thermoelectric legs, at a rate proportional to the applied current. However, Joule heating occurs throughout the device at a rate proportional to the current squared. Hence, in the steady state, the steady temperature difference that the device can sustain increases with current only to the point beyond which the Joule heating dominates. If a pulse of current greater than the optimum current (the current for maximum steady cooling) is applied, then the junction becomes momentarily cooled below its lowest steady temperature until thermal conduction brings the resulting pulse of Joule heat to the junction and thereby heats the junction above its lowest steady temperature. A theoretical and experimental study of such transient thermoelectric cooling followed by transient Joule heating in response to current pulses has been performed. The figure presents results from one of the experiments. The study established the essential parameters that characterize the pulse cooling effect, including the minimum temperature achieved, the maximum temperature overshoot, the time to reach minimum temperature, the time while cooled, and the time between pulses. It was found that at large pulse amplitude, the amount of pulse supercooling is about a fourth of the maximum steady-state temperature difference. For the particular thermoelectric device used in one set of the experiments, the practical optimum pulse amplitude was found to be about 3 times the optimum steady-state current. In a further experiment, a pulse cooler was integrated into a small commercial thermoelectric threestage cooler and found to provide several degrees of additional cooling for a time long enough to operate a semiconductor laser in a gas sensor.

Snyder, G. Jeffrey↗

The X-ray surface brightness distribution and spectral properties of six early-type galaxies

Detailed analysis is presented of the Einstein X-ray observations of six early-type galaxies. The results show that effective cooling is probably present in these systems, at least in the innermost regions. Interaction with the surrounding medium has a major effect on the X-ray surface brightness distribution at large radii, at least for galaxies in clusters. The data do not warrant the general assumptions of isothermality and gravitational hydrostatic equilibrium at large radii. Comparison of the X-ray surface brightness profiles with model predictions indicate that 1/r-squared halos with masses of the order of 10 times the stellar masses are required to match the data. The physical model of White and Chevalier (1984) for steady cooling flows in a King law potential with no heavy halo gives a surface brightness distribution that resembles the data if supernovae heating is present.

Trinchieri, G.↗

Strong influence of convective heat transfer efficiency on the cooling benefits of green roof irrigation

Abstract By enhancing evapotranspiration (ET), green roofs provide cooling benefits for the urban environment and are recognized as a promising heat mitigation strategy. The evaporative cooling effects of green roofs strongly depend on the soil moisture conditions and thus irrigation may be needed to sustain the cooling benefits. It has been shown that the magnitude of cooling benefits offered by green roof irrigation varies spatially, but its controlling factors remain elusive. In this study, we combine a surface energy balance (SEB) model with global simulations generated by an improved Earth System Model to illustrate the key factors controlling the cooling benefits of green roof irrigation. We employ a simple irrigation scheme, which is only active when there is no ice in soil layers and when the soil moisture is below field capacity. As a result, most of the irrigation water leaves the green roof system via ET. We find that the magnitude and also the spatial variability of the cooling benefits of green roof irrigation are controlled by the irrigation amount, and a surface energy redistribution factor that encodes the efficiencies of different SEB components in transferring heat. Further analysis indicates that the enhancement of latent heat flux due to irrigation is largely balanced by the reduction of sensible heat flux on green roofs. Therefore, the amount of irrigation needed per unit decrease of green roof surface temperature is mainly controlled by the convective heat transfer efficiency. A lower convective heat transfer efficiency (e.g. under a lower wind speed) helps reduce the amount of irrigation needed per unit decrease of green roof surface temperature. This study highlights the importance of SEB in constraining the cooling benefits of green roof irrigation and provides valuable guidance for urban planners and policy makers in terms of heat mitigation and sustainable water management.

Wang, Linying (ORCID:0000000308769220)↗

Aerosol Direct, Indirect, Semidirect, and Surface Albedo Effects from Sector Contributions Based on the IPCC AR5 Emissions for Preindustrial and Present-day Conditions

The anthropogenic increase in aerosol concentrations since preindustrial times and its net cooling effect on the atmosphere is thought to mask some of the greenhouse gas-induced warming. Although the overall effect of aerosols on solar radiation and clouds is most certainly negative, some individual forcing agents and feedbacks have positive forcing effects. Recent studies have tried to identify some of those positive forcing agents and their individual emission sectors, with the hope that mitigation policies could be developed to target those emitters. Understanding the net effect of multisource emitting sectors and the involved cloud feedbacks is very challenging, and this paper will clarify forcing and feedback effects by separating direct, indirect, semidirect and surface albedo effects due to aerosols. To this end, we apply the Goddard Institute for Space Studies climate model including detailed aerosol microphysics to examine aerosol impacts on climate by isolating single emission sector contributions as given by the Coupled Model Intercomparison Project Phase 5 (CMIP5) emission data sets developed for Intergovernmental Panel on Climate Change (IPCC) AR5. For the modeled past 150 years, using the climate model and emissions from preindustrial times to present-day, the total global annual mean aerosol radiative forcing is -0.6 W/m(exp 2), with the largest contribution from the direct effect (-0.5 W/m(exp 2)). Aerosol-induced changes on cloud cover often depends on cloud type and geographical region. The indirect (includes only the cloud albedo effect with -0.17 W/m(exp 2)) and semidirect effects (-0.10 W/m(exp 2)) can be isolated on a regional scale, and they often have opposing forcing effects, leading to overall small forcing effects on a global scale. Although the surface albedo effects from aerosols are small (0.016 W/m(exp 2)), triggered feedbacks on top of the atmosphere (TOA) radiative forcing can be 10 times larger. Our results point out that each emission sector has varying impacts by geographical region. For example, the single sector most responsible for a net positive radiative forcing is the transportation sector in the United States, agricultural burning and transportation in Europe, and the domestic emission sector in Asia. These sectors are attractive mitigation targets.

Bauer, Susanne E.↗

The Effect of Indian Ocean Temperature on the Pacific Trade Winds and ENSO

Abstract A notable shift in the El Niño‐Southern Oscillation (ENSO) has been observed in the early 21st century, characterized by an increased prevalence of Central Pacific (CP) events and strengthened Pacific trade winds. This shift may be attributed to the warming tropical Indian Ocean (TIO). To investigate this, we conduct perturbation experiments using the Insitut Pierre Simon Laplace climate model and nudge TIO surface temperatures to induce warming or cooling effects. Our findings reveal that TIO warming (or cooling) leads to amplified (weakened) mean trade winds and surface warming (cooling) in the Pacific region. Surprisingly, ENSO variability increases in both TIO cooling and warming scenarios. This result is linked to stronger positive feedbacks and a less stable Bjerknes index for either TIO forcing. Additionally, we find that TIO warming leads to more frequent CP events, meridional widening of wind anomalies, and broadening of the ENSO power spectrum toward lower frequencies.

Geology↗

Integrated cooling (i-Cool) textile of heat conduction and sweat transportation for personal perspiration management

Perspiration evaporation plays an indispensable role in human body heat dissipation. However, conventional textiles tend to focus on sweat removal and pay little attention to the basic thermoregulation function of sweat, showing limited evaporation ability and cooling efficiency in moderate/profuse perspiration scenarios. Here, we propose an integrated cooling (i-Cool) textile with unique functional structure design for personal perspiration management. By integrating heat conductive pathways and water transport channels decently, i-Cool exhibits enhanced evaporation ability and high sweat evaporative cooling efficiency, not merely liquid sweat wicking function. In the steady-state evaporation test, compared to cotton, up to over 100% reduction in water mass gain ratio, and 3 times higher skin power density increment for every unit of sweat evaporation are demonstrated. Besides, i-Cool shows about 3 °C cooling effect with greatly reduced sweat consumption than cotton in the artificial sweating skin test. The practical application feasibility of i-Cool design principles is well validated based on commercial fabrics. Owing to its exceptional personal perspiration management performance, we expect the i-Cool concept can provide promising design guidelines for next-generation perspiration management textiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Two-dimensional model studies of the effect of supersonic aircraft operations on the stratospheric ozone content

For a fleet of 250 aircraft, the change in the ozone column is predicted to be very close to zero; in fact, the ozone overburden may actually increase as a result of show that above 25 to 30 km the ozone abundance decreases via catalytic destruction, but at lower heights it increases, mainly as a result of coupling with odd hydrogen species. Water vapor released in the engine exhaust is predicted to cause ozone decreases; for the hypothetical engines used in the study, the total column ozone changes due to water vapor emission largely offset the predicted ozone increases due to NOx emission. The actual effect of water vapor may be less than calculated because present models do not include thermal feedback. Feedback refers to the cooling effect of additional water vapor that would tend to slow the NOx reactions which destroy ozone.

Whitten, R. C.↗

Albedo of crops as a nature-based climate solution to global warming

Abstract Surface albedo can affect the energy budget and subsequently cause localized warming or cooling of the climate. When we convert a substantial portion of lands to agriculture, land surface properties are consequently altered, including albedo. Through crop selection and management, one can increase crop albedo to obtain higher levels of localized cooling effects to mitigate global warming. Still, there is little understanding about how distinctive features of a cropping system may be responsible for elevated albedo and consequently for the cooling potential of cultivated lands. To address this pressing issue, we conducted seasonal measurements of surface reflectivity during five growing seasons on annual crops of corn-soybean–winter wheat ( Zea mays L.- Glycine max L. Merrill - Triticum aestivum L. ; CSW) rotations at three agronomic intensities, a monoculture of perennial switchgrass ( Panicum virgatum L. ), and perennial polycultures of early successional and restored prairie grasslands. 
We found that crop-species, agronomic intensity, seasonality, and plant phenology had significant effects on albedo. The mean±SD albedo was highest in perennial crops of switchgrass (0.179±0.04), intermediate in early successional crops (0.170±0.04), and lowest in a reduced input corn systems with cover crops (0.154±0.02). The strongest cooling potentials were found in soybean (-0.450 kg CO 2 e m -2 yr -1 ) and switchgrass (-0.367 kg CO 2 e m -2 yr -1 ), with up to -0.265 kg CO 2 e m -2 yr -1 of localized climate cooling annually provided by different agroecosystems. We also demonstrated how diverse ecosystems, leaf canopy, and agronomic practices can affect surface reflectivity and provide another potential nature-based solution for reducing global warming at localized scales.

Lei, Cheyenne (ORCID:0000000272746309)↗

Computational Study of Additively Manufactured Internally Cooled Airfoils for Industrial Gas Turbine Applications

Internal cooling features such as pin-fins, impingement jets, and rib-turbulators are necessary to keep turbine components cool, but if sufficiently advanced can potentially also eliminate the need for film cooling on turbine blades particularly in industrial gas turbines where temperatures are not extreme. Furthermore, by leveraging additive manufacturing, other advanced designs such as lattice and incremental impingement configurations are possible and have recently been experimentally tested. While the performance of such configurations has been quantified through means of overall cooling effectiveness, it is not as clear why certain designs were better than others, or what the mechanisms were behind the observed external cooling patterns. The purpose of this study was to computationally analyze different advanced turbine blade internal cooling designs previously tested by the National Energy Technology Laboratory.

CFD↗

Evaluating the Effect of Vane Trailing Edge Flow on Turbine Rim Sealing

Abstract Modern gas turbine development continues to move toward increased overall efficiency, driven in part by higher firing temperatures that point to a need for more cooling air to prevent catastrophic component failure. However, using additional cooling flow bled from the upstream compressor causes a corresponding detriment to overall efficiency. A primary candidate for cooling flow optimization is purge flow, which contributes to sealing the stator–rotor cavity and prevents ingestion of hot main gas path (MGP) flow into the wheelspace. Previous research has identified that the external main gas path flow physics play a significant role in driving rim seal ingestion. However, the potential impact of other cooling flow features on ingestion behavior, such as vane trailing edge (VTE) flow, is absent in the open literature. This paper presents experimental measurements of rim cavity cooling effectiveness collected from a one-stage turbine operating at engine-representative Reynolds and Mach numbers. Carbon dioxide (CO2) was used as a tracer gas in both the purge flow and vane trailing edge flow to investigate flow migration into and out of the wheelspace. Results show that the vane trailing edge flow does in fact migrate into the rim seal and that there is a superposition relationship between individual cooling flow contributions. Computational fluid dynamics (CFD) simulations using unsteady Reynolds-averaged Navier–Stokes (URANS) were used to confirm VTE flow ingestion into the rim seal cavity. Radial and circumferential traverse surveys were performed to quantify cooling flow radial migration through the main gas path with and without vane trailing edge flow. The surveys confirmed that vane trailing edge flow is entrained into the wheelspace as purge flow is reduced. Local CO2 measurements also confirmed the presence of VTE flow deep in the wheelspace cavity.

Engineering↗

Physiologic Responses Produced by Active and Passive Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to document and compare the subjects' response to three cooling vests in their recommended configurations. The Life Enhancement Tech (LET) lightweight active cooling vest with cap, the MicroClimate Systems Change of Phase garment (MCS), and the Steele Vest were each used to cool the chest regions of 12 male and 8 female Healthy subjects (21 to 69 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approx. 22 C), were tested for 60 min. with one of the cooling garments. The LET active garment had an initial coolant fluid inlet temperature of 60 F, and was ramped down to 50 F. Oral, right and left ear canal temperatures were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. For men, all three vests had similar, significant cooling effects. Decreases in the average rectal temperature, oral temperature, and ear canal temperatures were approximately 0.2 C, 0.2 C and 0.1 C, respectively. In contrast to the men, the female subjects wearing the MCS and Steel vests had similar cooling responses in which the core temperature remained elevated and oral and ear canal temperatures did not drop. The LET active garment cooled most of the female subjects in this study; rectal, oral and ear temperature decreased about 0.2 C, 0.3 C and 0.3 C, respectively. These results show that the garment configurations tested do not elicit a similar thermal response in all subjects. A gender difference is evident. The LET active garment configuration was most effective in decreasing temperatures of the female subjects; the MCS vest was least effective. For male subjects, the three vests appear to be more nearly equivalent. The active garment system under study included a cooling cap, which may account for some of the difference in response.

Ku, Yu-Tsuan E.↗

Environmental Co‐Benefits of Maintaining Native Vegetation With Solar Photovoltaic Infrastructure

Abstract Co‐locating solar photovoltaics with vegetation could provide a sustainable solution to meeting growing food and energy demands. However, studies quantifying multiple co‐benefits resulting from maintaining vegetation at utility‐scale solar power plants are limited. We monitored the microclimate, soil moisture, panel temperature, electricity generation and soil properties at a utility‐scale solar facility in a continental climate with different site management practices. The compounding effect of photovoltaic arrays and vegetation may homogenize soil moisture distribution and provide greater soil temperature buffer against extreme temperatures. The vegetated solar areas had significantly higher soil moisture, carbon, and other nutrients compared to bare solar areas. Agrivoltaics in agricultural areas with carbon debt can be an effective climate mitigation strategy along with revitalizing agricultural soils, generating income streams from fallow land, and providing pollinator habitats. However, the benefits of vegetation cooling effects on electricity generation are rather site‐specific and depend on the background climate and soil properties. Overall, our findings provide foundational data for site preservation along with targeting site‐specific co‐benefits, and for developing climate resilient and resource conserving agrivoltaic systems.

14 SOLAR ENERGY↗