Search NASA⌕ Search

SEARCH · Search NASA

Results for “Count”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Performance Analysis of Airborne Photon-Counting Lidar Data in Preparation for the ICESat-2 Mission

Two airborne photon-counting laser altimeters have been deployed in direct support of National Aeronautics and Space Adminsitration (NASA's) upcoming Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) mission. Multiple Altimeter Beam Experimental Lidar (MABEL) was developed specifically for ICESat-2 testing and development. MABEL data are used to simulate key aspects of the ICESat-2 measurement strategy and are critical to the development of the algorithms for geophysical data-product generation. Slope Imaging Multipolarization Photon-counting Lidar (SIMPL) is a NASA Goddard Space Flight Center instrument that has also been deployed in support of ICESat-2 performance discovery. Both instruments are photon-counting, small footprint laser altimeters that sample in both the 532- and 1064-nm wavelengths. And both instruments serve as a proxy for ICESat-2 operational performance and error assessment and a basis for the development of potential validation strategies. This paper provides an overview of how data from MABEL and SIMPL overflights have specifically provided the foundation for understanding the quality of ICESat-2 data and how we can plan to evaluate ICESat-2 products through comparison with other modalities of lidar data and/or groundtruth locations using ground fiducials.

MABEL↗

Photon Counting Detector Array Algorithms for Deep Space Optical Communications

For deep-space optical communications systems utilizing an uplink optical beacon, a single-photon-counting detector array on the flight terminal can be used to simultaneously perform uplink tracking and communications as well as accurate downlink pointing at photon-starved (pW/sq. m) power levels. In this paper, we discuss concepts and algorithms for uplink signal acquisition, tracking, and parameter estimation using a photon-counting camera. Statistical models of detector output data and signal processing algorithms are presented, incorporating realistic effects such as Earth background and detector/readout blocking. Analysis and simulation results are validated against measured laboratory data using state-of-the-art commercial photon-counting detector arrays, demonstrating sub-microradian tracking errors under channel conditions representative of deep space optical links.

beacon tracking↗

A Critical Look at Coulomb Counting Approach for State of Charge Estimation in Batteries

In this paper, we consider the problem of state-of-charge estimation for rechargeable batteries. Coulomb counting is a well-known method for estimating the state of charge, and it is regarded as accurate as long as the battery capacity and the beginning state of charge are known. The Coulomb counting approach, on the other hand, is prone to inaccuracies from a variety of sources, and the magnitude of these errors has not been explored in the literature. We formally construct and quantify the state-of-charge estimate error during Coulomb counting due to four types of error sources: (1) current measurement error; (2) current integration approximation error; (3) battery capacity uncertainty; and (4) timing oscillator error/drift. It is demonstrated that the state-of-charge error produced can be either time-cumulative or state-of-charge-proportional. Time-cumulative errors accumulate over time and have the potential to render the state-of-charge estimation utterly invalid in the long term. The proportional errors of the state of charge rise with the accumulated state of charge and reach their worst value within one charge/discharge cycle. The study presents methods for reducing time-cumulative and state-of-charge-proportional mistakes through simulation analysis.

Battery management system↗

Simulation of Rate-Related (Dead-Time) Losses In Passive Neutron Multiplicity Counting Systems

Passive Neutron Multiplicity Counting (PNMC) based on Multiplicity Shift Register (MSR) electronics (a form of time correlation analysis) is a widely used non-destructive assay technique for quantifying spontaneously fissile materials such as Pu. At high event rates, dead-time losses perturb the count rates with the Singles, Doubles and Triples being increasingly affected. Without correction these perturbations are a major source of inaccuracy in the measured count rates and assay values derived from them. This paper presents the simulation of dead-time losses and investigates the effect of applying different dead-time models on the observed MSR data. Monte Carlo methods have been used to simulate neutron pulse trains for a variety of source intensities and with ideal detection geometry, providing an event by event record of the time distribution of neutron captures within the detection system. The action of the MSR electronics was modelled in software to analyse these pulse trains. Stored pulse trains were perturbed in software to apply the effects of dead-time according to the chosen physical process; for example, the ideal paralysable (extending) and non-paralysable models with an arbitrary dead-time parameter. Results of the simulations demonstrate the change in the observed MSR data when the system dead-time parameter is varied. In addition, the paralysable and non-paralysable models of deadtime are compared. These results form part of a larger study to evaluate existing dead-time corrections and to extend their application to correlated sources. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of laminae count and manufacturing methods on mechanical properties of thin‐ply woven composites

Abstract Thin‐ply woven composites exhibit exceptional mechanical performance by delaying the onset of damage, making them suitable for high‐performance structural applications. This study outlines the impact of manufacturing techniques (vacuum bagging and hot pressing), ply count, and fiber waviness on the mechanical properties of aromatic thermosetting copolyester/carbon‐fiber (ATSP/CF) composites. The analysis encompasses several different ply counts, evaluating their effects on the in‐plane elastic modulus (0°–90°) and tensile strength. Results demonstrate that reducing the waviness (or crimp) ratio significantly enhances the in‐plane elastic modulus, with improvements up to 188%, highlighting the importance of fiber alignment. Vacuum bagging produced ply thicknesses from 128 to 58 μm for 1–36 plies, with in‐plane elastic moduli from 30.3 to 87.2 GPa, and 4‐ and 8‐ply samples showed approximately 40% higher stiffness than those made by hot pressing. ATSP resin with high thermal stability (up to 400°C) and recyclability was used. Furthermore, this study highlights the microstructural enhancements achieved through vacuum bagging, as revealed by scanning electron and optical microscopy, and micro‐computed tomography imaging. This paper provides insights into damage mitigation and achieving enhanced mechanical properties by controlling fiber waviness using vacuum bagging and higher ply count in thin‐ply ATSP/CF composites. Highlights Crimp ratio reduction enhances elastic in‐plane elastic modulus up to 188%. Vacuum bagging increases modulus over the hot pressing manufacturing method by 40%. Lowering thickness‐per‐ply increases failure strain from 0.8% to 1.2%. Explored the performance of a novel ATSP matrix with high recyclability and thermal stability.

Kushwaha, Shashank [The Grainger College of Engine↗

Worst crosstalk analysis in heterogeneous and trench assisted heterogeneous multicore fiber for different core counts and layouts

In order to obtain appreciably low worst crosstalk level in high core count multicore fiber, heterogeneous MCF with different core configurations and layouts have been investigated analytically using coupled mode equation. The variations in worst crosstalk behavior with respect to the bending radius, core configurations, core layouts, and outer cladding thickness have been analyzed. Further, the core count dependent variations in worst crosstalk level, core pitch, and peak bending radius in different core layouts have been presented. It has been observed that the selection of core configuration, core layout, and outer cladding thickness have significant impact on the reduction in worst crosstalk level. For example, in 12-core normal-index heterogeneous MCF with SLS structure, the core Configuration 1 can provide the worst crosstalk level reduced by 7.09 dB and 16.92 dB in comparison to the other two core configurations, i.e., Configuration 2, and Configuration 3, respectively. Further, for the same core count with TA Configuration 1, SLS core layout can achieve the reduced worst crosstalk level in comparison with circular ORS and DRS, hexagonal ORS and DRS respectively by 24.62 dB, 25.86 dB, 28.87 dB and 30.64 dB.

36 MATERIALS SCIENCE↗

Development of an Absolute Gas-Counting Capability for Low to Medium Activities

ABSTRACT Pacific Northwest National Laboratory (PNNL) is developing a capability to measure the absolute activity concentration of various gaseous radionuclides using length-compensated proportional-counting methods. This capability will enable the validation and use of low-level, gaseous radionuclide calibration standards for use in PNNL’s shallow underground laboratory. Two sets of unequal length proportional counters have been fabricated. These detector assemblies operate on a static gas-fill principle, in contrast to continuous, flow-through configurations. One set of three counters has been fabricated using ultra-low background (ULB) electroformed copper and low-background fabrication methods. Once fully operational, these ULB counters will be used in PNNL’s shallow underground counting laboratory for analysis of gases with low activity concentrations < 1 Bq/cc. A second set of four unequal length counters has been fabricated from Oxygen-Free High-Conductivity Copper (OFHC) using similar low-background cleaning and assembly methods. These OFHC counters will be operated above ground in the analysis of gases with activity concentrations in the range of 1-10 Bq/cc. A gas delivery system is being developed to actively mix the analyte gas with an appropriate amount of count-gas and uniformly deliver it to the counters with high accuracy and repeatability. A description of both detector assemblies and gas delivery system will be given along with a preliminary uncertainty analysis of a simulated 0.05 Bq/cm3 gas measurement.

Williams, Richard M.↗

Pulse shape discrimination of Cs 2 LiYCl 6 :Ce 3+ detectors at high count rate based on triangular and trapezoidal filters

Cs 2 LiYCl 6 :Ce 3+ (CLYC) detectors have demonstrated the capability to simultaneously detect γ-rays and thermal and fast neutrons with medium energy resolution, reasonable detection efficiency, and substantially high pulse shape discrimination performance. In this work, a disadvantage of CLYC detectors is the long scintillation decay times, which causes pulse pile-up at moderate input count rate. Pulse processing algorithms were developed based on triangular and trapezoidal filters to discriminate between neutrons and γ-rays at high count rate. The algorithms were first tested using low-rate data. They exhibit a pulse-shape discrimination performance comparable to that of the charge comparison method, at low rate. Then, they were evaluated at high count rate. Neutrons and γ-rays were adequately identified with high throughput at rates of up to 375 kcps. The algorithm developed using the triangular filter exhibits discrimination capability marginally higher than that of the trapezoidal filter based algorithm irrespective of low or high rate. The algorithms exhibit low computational complexity and are executable on an FPGA in real-time. Finally, they are also suitable for application to other radiation detectors whose pulses are piled-up at high rate owing to long scintillation decay times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward the Minimal Floating Operation Count Cholesky Decomposition of Electron Repulsion Integrals

As quantum chemistry calculations deal with molecular systems of increasing size, the memory requirement to store electron-repulsion integrals (ERIs) greatly outpaces the physical memory available in computing hardware. Here, the Cholesky decomposition of ERIs provides a convenient yet accurate technique to reduce the storage requirement of integrals. Recent developments of a two-step algorithm have drastically reduced the memory operation (MOP) count, leaving the floating operation (FLOP) count as the last frontier of cost reduction in the Cholesky ERI algorithm. In this report, we introduce a dynamic integral tracking, reusing, and compression/elimination protocol embedded in the two-step Cholesky ERI method. Benchmark studies suggest that this technique becomes particularly advantageous when the basis set consists of many computationally expensive high-angular-momentum basis functions. With this dynamic ERI improvement, the Cholesky ERI approach proves to be a highly efficient algorithm with minimal FLOP and MOP count.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved LC-MS/MS Spectral Counting Statistics by Recovering Low Scoring Spectra Matched to Confidently Identified Peptide Sequences

Spectral counting has become a popular semi-quantitative method for LC-MS/MS based proteome quantification; however, this methodology is often not reliable when proteins are identified by a small number of spectra. Here we present a simple strategy to improve spectral counting based quantification for low abundance proteins by recovering low quality or low scoring spectra for confidently identified peptides. In this approach, stringent data filtering criteria were initially applied to achieve confident peptide identifications with low false discovery rate (e.g., <1%) after LC-MS/MS analysis and database search by SEQUEST. Then, all low scoring MS/MS spectra that match to this set of confidently identified peptides were recovered, leading to more than 20% increase of total identified spectra. The validity of these recovered spectra was assessed by the parent ion mass measurement error distribution, retention time distribution, and by comparing the individual low score and high score spectra that correspond to the same peptides. The results support that the recovered low scoring spectra have similar confidence levels in peptide identifications as the spectra passing the initial stringent filter. The application of this strategy of recovering low scoring spectra significantly improved the spectral count quantification statistics for low abundance proteins, as illustrated in the identification of mouse brain region specific proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Fast Neutron Dose Evaluation Using CR39 by Coincidence Counting Process

The solid state nuclear tracks detection (SSNTD) technique is widely used in the area of radiation dosimetry. Different materials can be used applying this technique as glass and the most used in the dosimetry field that are the polycarbonates, CR39 and Makrofol-DE. Both are very rich in hydrogenous, that enables the SSNTD to detect fast neutrons through recoils of protons in the own detector material, without need of converters. The low reproducibility of its backgroundhas often been the major drawback in the assessment of low fluences of fast neutrons with SSNTDs. This problem can be effectively solved by counting coincidence of tracks in two detectors foils irradiated in close contact. After processing and counting only tracks produced by the same recoil nuclei on the surfaces of both detectors are considered as a track. This procedure enables the reduction of the background counts in the response of the detectors. In this work a preliminary study on the application of the coincidence technique for neutron dosimetry is presented. The CR39 material was investigated aiming to achieve the personal dose equivalent for fast neutrons. Using this method of analysis a significant reduction on the lower detectable dose was observed resulting even one order of magnitude smaller value. Reading, however, needs to be automated due to the large areas necessary to achieve a satisfactory number of tracks for statistical significance of results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Perturbative Renormalizability of Chiral Two Pion Exchange and Power Counting in Nucleon-Nucleon Scattering

We show how to renormalize chiral two pion exchange perturbatively if one pion exchange has already been fully iterated at leading order. This particular choice corresponds to the implementation of the counting proposal of Nogga, Timmermans and van Kolck at subleading orders. We illustrate why the perturbative treatment of the two pion exchange contributions is mandatory in order to avoid certain inconsistencies in Weinberg's counting. In addition, renormalizability implies modifications of the power counting which we explore for the particular case of the singlet channel.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of two HPGe counting system used in activation studies for nuclear astrophysics

The activation method is a widely used technique to measure charged-particle induced cross sections for astrophys-ical applications. This two step technique is used for example to measure alpha-induced cross sections in γ-process related studies. The first step – in which a target is irradiated with a proton/alpha beam – is followed by the determination of the produced activity. Especially in p-process related studies in the heavier mass range, the produced radioactive nuclei decays mainly with electron-capture, resulting intense x-rays. The activity of the reaction products hence can be determine via the counting of these x-rays, and not only by counting the usually much weaker γ-rays. In this paper we compare the minimum detectable activity (MDA) of two High Purity Germanium (HPGe) detectors used for x- and γ-ray counting in activation experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calibration of a broadband x-ray crystal spectrometer using a continuum x-ray source and photon-counting detectors

We report measurements of sensitivity of a broadband (≃20–30 keV) x-ray crystal spectrometer using a bremsstrahlung continuum x-ray source and several detectors, including an energy-discriminating photon-counting point detector (Si drift diode, Amptek Inc.), imaging hybrid photon-counting detectors (Eiger2-Si and Eiger2-CdTe, DECTRIS Ltd.), and image plates (SR type). Sensitivity is defined as a ratio of the crystal-reflected energy-position-dispersed spectrum measured by a given detector to the incident non-dispersed spectrum measured using the energy-discriminating point detector. The sensitivity derived from data measured exclusively by the point detector is considered detector-independent and serves as a reference. The sensitivities derived from data collected with the hybrid photon-counting detectors were matched to the reference using a scale factor of 1.05. The image plate-derived sensitivities required a scale factor of 1.16 to match the reference. Furthermore, the resulting mismatch in the shapes of all measured scaled sensitivities in the range of the spectrometer was ≲±10%, while the mismatch between the shapes of the sensitivities corresponding to the Si-based detectors was ≲±2.5%.

Crystal optics↗

Constrained variational optimization of counting-time allocation in sequential scattering measurements: Application to Bonse–Hart USANS

Sequential scattering measurements are often performed under a fixed experimental-time budget, even though the expected count rate varies strongly across the measured coordinate. When the dwell time at each measurement position can be controlled independently, this variation creates a general resource-allocation problem: how should the available time be distributed to minimize the uncertainty of the reconstructed profile? We formulate this problem as a constrained variational optimization for measurements governed by Poisson counting statistics. When each measurement is treated independently, minimizing the averaged squared relative uncertainty yields an inverse-square-root intensity allocation. The formulation is then generalized to include correlations between neighboring measurements and an instrumental resolution operator, leading to an allocation criterion that equalizes the marginal reduction in posterior uncertainty per unit measurement time. Bonse–Hart ultra-small-angle neutron scattering (USANS), in which reciprocal space is sampled sequentially through analyzer-angle stepping, provides an experimentally grounded application. Computational benchmarking shows that the optimized allocation outperforms uniform-time and constant-relative-error strategies, while application to an experimentally measured graphite USANS profile from the Spallation Neutron Source, using Poisson resampling under alternative schedules, demonstrates how counting time should be redistributed toward weak-intensity regions under an identical total duration. The resulting framework applies to sequential scattering and related scanning measurements whenever local dwell times are adjustable and directly determine the measurement uncertainties, and when the relevant correlation and instrumental-response models are available.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

Edge counts for the auxiliary pair graph within the graphical unitary group approach

Closed-form expressions are presented for the numbers of edges in the auxiliary pair graphs (APGs) associated with non spin-orbit and spin-orbit Shavitt graphs for full configuration interaction expansions. A Shavitt graph is a visual representation of a configuration state function expansion space constructed via the graphical unitary group approach (GUGA). An APG is an organisational aid and a programmatic tool generated from a Shavitt graph. The number of edges in an APG determines bounds on the computational scaling as a function of the total numbers of electrons, orbitals, and spin multiplicities. The edge counts extend a suite of Shavitt graph statistics based on these functional parameters. The derivation and the presentation of the formulas for the edge counts has been assisted by the bra-ket interchange symmetry and the particle-hole interchange symmetry in the GUGA formalism. Furthermore, these symmetry operators produce one-to-one correspondences between various sets of edges, and this yields identities among some edge count formulas. There are 208 possible edge types. Of these, some do not contribute to two-electron operators, some are related by bra-ket interchange symmetry, and some are related by particle-hole interchange symmetry. For the remaining unique edge types, explicit expressions are derived for the numbers of edges.

74 ATOMIC AND MOLECULAR PHYSICS↗

FPGA-based gating and logic for multichannel single photon counting

We present results characterizing multichannel InGaAs single photon detectors utilizing gated passive quenching circuits (GPQC), self-differencing techniques, and field programmable gate array (FPGA)-based logic for both diode gating and coincidence counting. Utilizing FPGAs for the diode gating frontend and the logic counting backend has the advantage of low cost compared to custom built logic circuits and current off-the-shelf detector technology. Further, FPGA logic counters have been shown to work well in quantum key distribution (QKD) test beds. Our setup combines multiple independent detector channels in a reconfigurable manner via an FPGA backend and post processing in order to perform coincidence measurements between any two or more detector channels simultaneously. Using this method, states from a multi-photon polarization entangled source are detected and characterized via coincidence counting on the FPGA. Photons detection events are also processed by the quantum information toolkit for application testing (QITKAT)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NEAR-INFRARED GALAXY COUNTS AND EVOLUTION FROM THE WIDE-FIELD ALHAMBRA SURVEY

The ALHAMBRA survey aims to cover 4 deg{sup 2} using a system of 20 contiguous, equal width, medium-band filters spanning the range 3500 A-9700 A plus the standard JHKs filters. Here we analyze deep near-IR number counts of one of our fields (ALH08) for which we have a relatively large area (0.5 deg{sup 2}) and faint photometry (J = 22.4, H = 21.3, and K = 20.0 at the 50% of recovery efficiency for point-like sources). We find that the logarithmic gradient of the galaxy counts undergoes a distinct change to a flatter slope in each band: from 0.44 at [17.0, 18.5] to 0.34 at [19.5, 22.0] for the J band; for the H band 0.46 at [15.5, 18.0] to 0.36 at [19.0, 21.0], and in Ks the change is from 0.53 in the range [15.0, 17.0] to 0.33 in the interval [18.0, 20.0]. These observations together with faint optical counts are used to constrain models that include density and luminosity evolution of the local type-dependent luminosity functions. Our models imply a decline in the space density of evolved early-type galaxies with increasing redshift, such that only 30%-50% of the bulk of the present day red ellipticals was already in place at z {approx} 1.

79 ASTRONOMY AND ASTROPHYSICS↗