Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cryogenic cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Characterization of CdZnTeSe Nuclear Detector Chemically Etched in Bromine Methanol

Semiconductor nuclear radiation detectors made from tertiary and quaternary compounds of cadmium telluride (CdTe) can operate at room temperature without cryogenic cooling. One of such materials that have become of great interest is cadmium zinc telluride selenide (CdZnTeSe). Compared to other CdTe-based materials, such as cadmium zinc telluride (CdZnTe), CdZnTeSe can be grown with much less Te inclusions and sub-grain boundary networks. Chemical etching is often used to smoothen wafer surfaces during detector fabrication. This paper presents the characterization of CdZnTeSe that is chemically etched using bromine methanol solution. Infrared imaging shows that the wafer has no sub-grain boundary networks that often limit detector performance. The current-voltage (I-V) characterization experiment gave a resistivity of 4.6 × 10 10 Ω-cm for the sample. The I-V curve was linear in the ±10 to ±50 volts range. An energy resolution of 7.2% was recorded at 100 V for the 59.6-keV gamma line of 241 Am.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Highly stable microwave delay line

TWM /Traveling Wave Master/ comb structure serves as a highly stable microwave delay line for determining the short-term stability of the hydrogen maser frequency standards used in the deep space network. Cryogenic cooling is used to minimize signal attenuation and thermal noise.

Higa, W. H.↗

Wide-range nuclear magnetic resonance detector

Compact and easy to use solid state nuclear magnetic resonance detector is designed for measuring field strength to 20 teslas in cryogenically cooled magnets. Extremely low noise and high sensitivity make detector applicable to nearly all types of analytical nuclear magnetic resonance measurements and can be used in high temperature and radiation environments.

Sturman, J. C.↗

Shuttle cryogenic supply system optimization study. Volume 1: Management supply, sections 1 - 3

An analysis of the cryogenic supply system for use on space shuttle vehicles was conducted. The major outputs of the analysis are: (1) evaluations of subsystem and integrated system concepts, (2) selection of representative designs, (3) parametric data and sensitivity studies, (4) evaluation of cryogenic cooling in environmental control subsystems, and (5) development of mathematical model.

Source record↗

Cryogenic applications for environment simulation.

Some of the applications of cryogenics for simulating space environmental conditions are reviewed, and typical existing space simulation facilities are described. The techniques of adapting cryogenics to environmental simulation are discussed. Special attention is given to cryosorption pumps designed to accelerate cryogenic cooling of the adsorbent material.

Hardgrove, W. F.↗

Infrared telescopes for a space observatory

A cryogenically cooled infrared telescope of 1 to 2 meter aperture is discussed. Advantages of the space environment are detailed, and design considerations for cooled telescopes are given, leading to a schematic and preliminary design of a telescope for the space shuttle. The advantages of the sortie mode to an infrared observatory are dealt with and possible use of an ambient temperature telescope is discussed. Costs of infrared telescope observation are indicated.

Witteborn, F. S.↗

An S-band radiometer design with high absolute precision

A radiometer for the remote measurement of sea surface temperature is described. The development of an instrument capable not only of high relative accuracy (i.e., resolution) but also of high absolute precision is considered. The concepts underlying the design of an instrument capable of an absolute accuracy of a few tenths degrees Kelvin in the measurement of brightness temperature at S band are described. The role of the antenna is discussed, and the importance of high ohmic and beam efficiencies is stressed. The hardware itself is fully described, along with an outline concerning the design of a unique cryogenically cooled termination used to calibrate the whole radiometer, including antenna. Finally, some test results are presented that show that the design goals for the instrument have been closely approached.

Hardy, W. N.↗

Infrared upconversion as a means of seeing in the dark

A new approach to seeing in the dark is described which is based on the principles of nonlinear optics employing a crystal such as lithium iodate. A nonlinear optical device capable of producing photons at higher frequencies from lower-frequency incident light is shown to upconvert infrared light directly into visible light. The major advantages of the infrared upconversion process is that it permits the infrared signal to be detected by photon-counting devices presently available for the visible spectral region, and that it can provide sensitivity to infrared radiation without the need for cryogenic cooling of the detector used. Early works on infrared upconversion are reviewed. The development of applications is discussed as to astronomical spectroscopy and infrared image upconversion involving either angular or positional resolution elements. The demonstration of infrared upconversion in rectangular waveguides of single-crystal GaAs by Anderson et al. (1971) indicates future possibilities in upconversion by the use of integrated optics devices.

Gurski, T. R.↗

Low-noise room-temperature and cryogenic mixers for 80-120 GHz

A description is given of two new mixers designed to operate in the 80-120-GHz range on 36-ft radio telescope. It is shown that for a hard-driven diode the parasitic resistance and capacitance are the primary factors influencing the design of the diode mount. A room-temperature mixer is described which achieves a single-sideband (SSB) conversion loss (L) of 5.5 dB, and a SSB noise temperature (Tm) of 500 K (excluding the IF contribution) with a 1.4-GHz IF. A cryogenically cooled version, using a quartz structure to support the diode chip and contact whisker, achieves values of L = 5.8 dB and Tm = 300 K with a 4.75-GHz IF. The mixers use high-quality Schottky-barrier diodes in a one-quarter-height waveguide mount.

Kerr, A. R.↗

A radiometer for monitoring column densities of infrared-active molecules

A cryogenically cooled radiometer capable of accurately measuring the infrared background from 3.5 to 100 microns and the column density of water vapor for the low values specified for the space shuttle orbiter is described. The infrared spectral characteristics of the contaminant atmosphere are considered as well as the spectral characteristics of the natural IR background. The measurement technique is described in detail.

Witteborn, F. C.↗

Obtaining ultradry crystalline solids

Drying, cryogenic cooling, and redrying with high temperature and vacuum techniques, reduces moisture in crystalline solids to less than 0.01%.

Attar, A.↗

Atmosphere, Magnetosphere and Plasmas in Space (AMPS). Spacelab payload definition study. Volume 7, book 3: Supporting Research and Technology (SR and T) report

The items identified as required to support the AMPS mission and requiring SR and T support and further work are: (1) a general purpose Experiment Pointing Mount; (2) a technique for measuring the attitude of the pallet-mounted or deployed experiments; (3) the development of a common optics cryogenically cooled interferometer spectrometer; (4) the development of a differential absorption lidar system for the measurement of ozone densitites in the earth's atmosphere; (5) the development of dc to dc power processors which are capable of converting energy stored in a capacitor system at 500 V to energy supplied to equipment operating at 40 kV and at 20 kW (eventually up to 100 kW); and (6) the development of a magnetic or possibly electrostatic deflection system capable of bending the beam of an electron accelerator. A data sheet is included for each item, briefly describing the background and need for each item, and the general objectives of the required development, and identifying the schedule requirements in support of the AMPS program.

Source record↗

Development, applications, and future of infrared upconversion

Infrared upconversion is a technique that converts linearly polarized infrared photons to photons of higher frequency. The technique can be applied advantageously to the detection of IR radiation because the upconverted signal can be detected by photon-counting devices available for the visible spectral region. In addition, unlike presently available IR detectors, an upconversion device can provide sensitivity to IR radiation without the need for cryogenic cooling. Infrared upconversion was first demonstrated in 1961. By 1974, approximately 100% quantum conversion efficiency and a bandwidth of 1.81 microns had been attained. Photometric detection of IR radiation from various astronomical objects had also been demonstrated. Research is presently under way on the application of upconversion to astronomical spectroscopy and to imaging. The major drawback to the upconversion technique is the sheer bulk of the apparatus involved. It is anticipated that this problem can be overcome by applying the developing technology of integrated optics.

Gurski, T. R.↗