Search NASA⌕ Search

SEARCH · Search NASA

Results for “DISEASE DETECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Quantum AI Based Enhanced Detection of Dementia

Quantum computing has the potential to significantly improve the early detection of Alzheimer's Disease and Related Dementias (ADRD). Quantum-enhanced machine learning can be used to perform an early screening of Alzheimer's disease using brain imaging data based on dataset of MRI scans from both healthy individuals and those diagnosed with Alzheimer's. This study aims to demonstrate the potential of quantum transfer learning to enhance the performance of the classical deep learning model for dementia detection. Using the MRI sagittal images available in the OASIS-2 (64 demented and 72 non-demented subjects between 60 and 96 years), we show how quantum techniques can transform a suboptimal classical model into a more effective solution for dementia detection, highlighting their potential impact on advancing healthcare technology. We begin with a simple classical deep learning model with a significantly smaller number of parameters, which gives suboptimal performance on the problem. Then, we apply different configurations of quantum transfer learning based on the pre-trained weak classifier (Figure 1). We fix the weak classifier's initial convolutional layers at their fixed pre-trained parameters and replace the last set of dense layers with a dressed quantum circuit (DQN), which we train to enhance performance. We performed 4-fold cross-validation for both the classical and the hybrid quantum models and trained them using Pennylane's `default.qubit' simulator and IonQ's Aria-1 simulator (noisy simulation). We showed that with significantly fewer parameters, the quantum transfer learning-based hybrid models showed significant performance enhancement over the base weak classical deep learning model for dementia detection. To classify between a demented and non-demented subject, the accuracy of quantum-based AI methods improved by 6 to 14% compared to classical methods. The sensitivity of the models improved by 4 to 17%. This shows that there are fewer chances of misclassifying demented patients. Figure 2 compares the performance of the hybrid quantum models and their base classical model, and Table 1 summarizes the results. We illustrated that with assistance from quantum machine learning, it is possible to enhance detection for dementia based on brain images. This shows the potential for practical utility of quantum computing in ADRD research.

Bhowmik, Sounak [University of Tennessee, Knoxvill↗

Rotaxane Probes for the Detection of Hydrogen Peroxide by 129 Xe HyperCEST NMR Spectroscopy

The development of sensitive and chemically selective MRI contrast agents is imperative for the early detection and diagnosis of many diseases. Conventional responsive contrast agents used in 1 H MRI are impaired by the high abundance of protons in the body. 129 Xe hyperCEST NMR/MRI comprises a highly sensitive complement to traditional 1 H MRI because of its ability to report specific chemical environments. To date, the scope of responsive 129 Xe NMR contrast agents lacks breadth in the specific detection of small molecules, which are often important markers of disease. Herein, we report the synthesis and characterization of a rotaxane-based 129 Xe hyperCEST NMR contrast agent that can be turned on in response to H 2 O 2 , which is upregulated in several disease states. Finally, added H 2 O 2 was detected by 129 Xe hyperCEST NMR spectroscopy in the low micromolar range, as well as H 2 O 2 produced by HEK 293T cells activated with tumor necrosis factor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Colorimetric Loop-Mediated Isothermal Amplification Assay for the Detection of Trypanosoma cruzi in Low-Resource Settings

Chagas disease is an inflammatory parasitic infection caused by Trypanosoma cruzi (T. cruzi). Early diagnosis is crucial in guiding treatment and slowing disease progression; however, current diagnostic methods have insufficient detection limits and often require skilled technicians. Molecular tests, especially isothermal nucleic acid assays, are advantageous due to their excellent sensitivity, specificity, speed, and simplicity. Here, we optimized a colorimetric loop-mediated isothermal amplification (LAMP) assay for T. cruzi. We can detect as few as 2 genomic copies/reaction using three different T. cruzi strains. We examined selectivity using other parasitic protozoans and successfully detected T. cruzi DNA extracted from parasites in human whole blood down to 1.2 parasite equivalents/reaction. We also performed a blinded study using canine blood samples and established a 100% sensitivity, specificity, and accuracy for the colorimetric LAMP assay. Finally, we used a heated 3D printer bed and an insulated thermos cup to demonstrate that the LAMP incubation step could be performed with accessible, low-cost materials. Altogether, we have developed a high-performing assay for T. cruzi with a simple colorimetric output that would be ideal for rapid, low-cost screening at the point of use.

60 APPLIED LIFE SCIENCES↗

Classification System for Identifying Women at Risk for Altered Partial Breast Irradiation Recommendations After Breast Magnetic Resonance Imaging

Purpose: To study the utility of preoperative breast MRI for partial breast irradiation (PBI) patient selection, using multivariable analysis of significant risk factors to create a classification rule. Methods and Materials: Between 2002 and 2009, 712 women with newly diagnosed breast cancer underwent preoperative bilateral breast MRI at Mayo Clinic Florida. Of this cohort, 566 were retrospectively deemed eligible for PBI according to the National Surgical Adjuvant Breast and Bowel Project Protocol B-39 inclusion criteria using physical examination, mammogram, and/or ultrasound. Magnetic resonance images were then reviewed to determine their impact on patient eligibility. The patient and tumor characteristics were evaluated to determine risk factors for altered PBI eligibility after MRI and to create a classification rule. Results: Of the 566 patients initially eligible for PBI, 141 (25%) were found ineligible because of pathologically proven MRI findings. Magnetic resonance imaging detected additional ipsilateral breast cancer in 118 (21%). Of these, 62 (11%) had more extensive disease than originally noted before MRI, and 64 (11%) had multicentric disease. Contralateral breast cancer was detected in 28 (5%). Four characteristics were found to be significantly associated with PBI ineligibility after MRI on multivariable analysis: premenopausal status (P=.021), detection by palpation (P<.001), first-degree relative with a history of breast cancer (P=.033), and lobular histology (P=.002). Risk factors were assigned a score of 0-2. The risk of altered PBI eligibility from MRI based on number of risk factors was 0:18%; 1:22%; 2:42%; 3:65%. Conclusions: Preoperative bilateral breast MRI altered the PBI recommendations for 25% of women. Women who may undergo PBI should be considered for breast MRI, especially those with lobular histology or with 2 or more of the following risk factors: premenopausal, detection by palpation, and first-degree relative with a history of breast cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pet imaging of zinc transport

A method for producing a solution including a positron emitting zinc cation of .sup.63Zn, and the method comprises bombarding a solution target including .sup.63Cu with high energy protons to produce a solution including a positron emitting zinc cation. A method for detecting or ruling out Alzheimer's disease in a patient comprises administering to a patient a detectable amount of a compound including a positron emitting zinc cation, wherein the zinc cation is targeted to beta-amyloid in the patient, and acquiring an image to detect the presence or absence of beta-amyloid in the patient.

Degrado, Timothy R.↗

PET imaging of zinc transport

A method for producing a solution including a positron emitting zinc cation of 63Zn, and the method comprises bombarding a solution target including 63 Cu with high energy protons to produce a solution including a positron emitting zinc cation. A method for detecting or ruling out Alzheimer's disease in a patient comprises administering to a patient a detectable amount of a compound including a positron emitting zinc cation, wherein the zinc cation is targeted to β-amyloid in the patient, and acquiring an image to detect the presence or absence of β-amyloid in the patient. A method for detecting or ruling out cancer in a patient comprises administering to a patient a detectable amount of a compound including a positron emitting zinc cation, wherein the zinc cation is targeted to tissue in the patient; and acquiring an image using a medical imaging technique to detect zinc distribution in tissue in the patient.

DeGrado, Timothy R.↗

Deep Recurrent Neural Networks for seizure detection and early seizure detection systems

Epilepsy is common neurological diseases, affecting about 0.6-0.8 % of world population. Epileptic patients suffer from chronic unprovoked seizures, which can result in broad spectrum of debilitating medical and social consequences. Since seizures, in general, occur infrequently and are unpredictable, automated seizure detection systems are recommended to screen for seizures during long-term electroencephalogram (EEG) recordings. In addition, systems for early seizure detection can lead to the development of new types of intervention systems that are designed to control or shorten the duration of seizure events. In this article, we investigate the utility of recurrent neural networks (RNNs) in designing seizure detection and early seizure detection systems. We propose a deep learning framework via the use of Gated Recurrent Unit (GRU) RNNs for seizure detection. We use publicly available data in order to evaluate our method and demonstrate very promising evaluation results with overall accuracy close to 100 %. We also systematically investigate the application of our method for early seizure warning systems. Our method can detect about 98% of seizure events within the first 5 seconds of the overall epileptic seizure duration.

59 BASIC BIOLOGICAL SCIENCES↗

Integrating biological knowledge for mechanistic inference in the host-associated microbiome

Advances in high-throughput technologies have enhanced our ability to describe microbial communities as they relate to human health and disease. Alongside the growth in sequencing data has come an influx of resources that synthesize knowledge surrounding microbial traits, functions, and metabolic potential with knowledge of how they may impact host pathways to influence disease phenotypes. These knowledge bases can enable the development of mechanistic explanations that may underlie correlations detected between microbial communities and disease. In this review, we survey existing resources and methodologies for the computational integration of broad classes of microbial and host knowledge. We evaluate these knowledge bases in their access methods, content, and source characteristics. We discuss challenges of the creation and utilization of knowledge bases including inconsistency of nomenclature assignment of taxa and metabolites across sources, whether the biological entities represented are rooted in ontologies or taxonomies, and how the structure and accessibility limit the diversity of applications and user types. We make this information available in a code and data repository at: https://github.com/lozuponelab/knowledge-source-mappings. Addressing these challenges will allow for the development of more effective tools for drawing from abundant knowledge to find new insights into microbial mechanisms in disease by fostering a systematic and unbiased exploration of existing information.

59 BASIC BIOLOGICAL SCIENCES↗

Improved diagnosis of the number of stenosed coronary artery vessels by segmentation with scatter and photo-peak window data for attenuation correction in myocardial perfusion SPECT

Background: Attenuation correction using segmentation of scatter and photo-peak window data (SSPAC) enables an evaluation of the attenuation map in a patient-specific manner without additional radiation exposure. We compared the accuracy of SSPAC and non-corrected myocardial perfusion scintigraphy methods for diagnosing the number of stenosed coronary artery vessels. Methods and Results: We retrospectively reviewed the data from 183 consecutive patients who underwent {sup 99m}Tc-tetrofosmin stress/rest SPECT examination and a coronary angiography within 3 months. The MPS images were reconstructed with and without SSPAC attenuation correction. We examined the accuracy of the quantitative interpretation using summed differential score in the detection of coronary artery disease (CAD). The attenuation maps were successfully determined in 179 of 183 patients (98%). In terms of the vessel-based diagnostic ability, sensitivity, specificity, positive predictive and negative predictive values of the SSPAC and non-correction methods for diagnosing CAD in individual coronary territories were 77%*, 89%, 74%*, and 90%* vs 51%, 87%, 62%, and 82%, respectively (*P < .05). In 35 patients with multi-vessel CAD, those values were 78%*, 81%, 93%, and 55%* vs 49%, 81%, 89%, and 34%, respectively (*P < .05; AUC: 0.82 vs 0.62, P < .05). Conclusion: SSPAC-corrected SPECT myocardial perfusion images exhibit improved accuracy in the detection of the number of stenosed coronary artery vessels, even in patients with multi-vessel CAD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid, portable, multiplexed detection of bacterial pathogens directly from clinical sample matrices

Enteric and diarrheal diseases are a major cause of childhood illness and death in countries with developing economies. Each year, more than half of a million children under the age of five die from these diseases. We have developed a portable, microfluidic platform capable of simultaneous, multiplexed detection of several of the bacterial pathogens that cause these diseases. Furthermore, this platform can perform fast, sensitive immunoassays directly from relevant, complex clinical matrices such as stool without extensive sample cleanup or preparation. Using only 1 µL of sample per assay, we demonstrate simultaneous multiplexed detection of four bacterial pathogens implicated in diarrheal and enteric diseases in less than 20 min.

47 OTHER INSTRUMENTATION↗

Quantitative Proteome Mapping of Nitrotyrosines

An essential first step in the understanding disease and environmental perturbations is the early and quantitative detection of the increased levels of the inflammatory marker nitrotyrosine, as compared with its endogenous levels within the tissue or cellular proteome. Thus, methods that successfully address a proteome-wide quantitation of nitrotyrosine and related oxidative modifications can provide early biomarkers of risk and progression of disease as well as effective strategies for therapy. Multidimensional separations LC coupled with tandem mass spectrometry (LC-MS/MS) has, in recent years, significantly expanded our knowledge of human (and mammalian model system) proteomes including some nascent work in identification of post-translational modifications. In the following review, we discuss the application of LC-MS/MS for quantitation and identification of nitrotyrosine-modified proteins within the context of complex protein mixtures presented in mammalian proteomes.

59 BASIC BIOLOGICAL SCIENCES↗

Remote sensing of vigor loss in conifers due to dwarf mistletoe

The initial operation of a multiband/multidate tower-tramway test site in northeastern Minnesota for the development of specifications for subsequent multiband aerial photography of more extensive study areas was completed. Multiband/multidate configurations suggested by the tower-tramway studies were and will be flown with local equipment over the Togo test site. This site was photographed by the NASA RB57F aircraft in August and September 1971. It appears that, of all the film/filter combinations attempted to date (including optical recombining of several spectral band images via photo enhancement techniques), Ektachrome infrared film with a Wratten 12 filter is the best for detecting dwarf mistletoe, and other tree diseases as well. Using this film/filter combination, infection centers are easily detectable even on the smallest photo scale (1:100,000) obtained on the Togo site.

Meyer, M. P.↗

COMPACT CdZnTe-BASED GAMMA CAMERA FOR PROSTATE CANCER IMAGING

In this paper, we discuss the design of a compact gamma camera for high-resolution prostate cancer imaging using Cadmium Zinc Telluride (CdZnTe or CZT) radiation detectors. Prostate cancer is a common disease in men. Nowadays, a blood test measuring the level of prostate specific antigen (PSA) is widely used for screening for the disease in males over 50, followed by (ultrasound) imaging-guided biopsy. However, PSA tests have a high false-positive rate and ultrasound-guided biopsy has a high likelihood of missing small cancerous tissues. Commercial methods of nuclear medical imaging, e.g. PET and SPECT, can functionally image the organs, and potentially find cancer tissues at early stages, but their applications in diagnosing prostate cancer has been limited by the smallness of the prostate gland and the long working distance between the organ and the detectors comprising these imaging systems. CZT is a semiconductor material with wide band-gap and relatively high electron mobility, and thus can operate at room temperature without additional cooling. CZT detectors are photon-electron direct-conversion devices, thus offering high energy-resolution in detecting gamma rays, enabling energy-resolved imaging, and reducing the background of Compton-scattering events. In addition, CZT material has high stopping power for gamma rays; for medical imaging, a few-mm-thick CZT material provides adequate detection efficiency for many SPECT radiotracers. Because of these advantages, CZT detectors are becoming popular for several SPECT medical-imaging applications. Most recently, we designed a compact gamma camera using CZT detectors coupled to an application-specific-integrated-circuit (ASIC). This camera functions as a trans-rectal probe to image the prostate gland from a distance of only 1-5 cm, thus offering higher detection efficiency and higher spatial resolution. Hence, it potentially can detect prostate cancers at their early stages. The performance tests of this camera have been completed. The results show better than 6-mm resolution at a distance of 1 cm. Details of the test results are discussed in this paper.

36 MATERIALS SCIENCE↗

Computerized analysis of coronary artery disease: Performance evaluation of segmentation and tracking of coronary arteries in CT angiograms

Purpose: The authors are developing a computer-aided detection system to assist radiologists in analysis of coronary artery disease in coronary CT angiograms (cCTA). This study evaluated the accuracy of the authors’ coronary artery segmentation and tracking method which are the essential steps to define the search space for the detection of atherosclerotic plaques. Methods: The heart region in cCTA is segmented and the vascular structures are enhanced using the authors’ multiscale coronary artery response (MSCAR) method that performed 3D multiscale filtering and analysis of the eigenvalues of Hessian matrices. Starting from seed points at the origins of the left and right coronary arteries, a 3D rolling balloon region growing (RBG) method that adapts to the local vessel size segmented and tracked each of the coronary arteries and identifies the branches along the tracked vessels. The branches are queued and subsequently tracked until the queue is exhausted. With Institutional Review Board approval, 62 cCTA were collected retrospectively from the authors’ patient files. Three experienced cardiothoracic radiologists manually tracked and marked center points of the coronary arteries as reference standard following the 17-segment model that includes clinically significant coronary arteries. Two radiologists visually examined the computer-segmented vessels and marked the mistakenly tracked veins and noisy structures as false positives (FPs). For the 62 cases, the radiologists marked a total of 10191 center points on 865 visible coronary artery segments. Results: The computer-segmented vessels overlapped with 83.6% (8520/10191) of the center points. Relative to the 865 radiologist-marked segments, the sensitivity reached 91.9% (795/865) if a true positive is defined as a computer-segmented vessel that overlapped with at least 10% of the reference center points marked on the segment. When the overlap threshold is increased to 50% and 100%, the sensitivities were 86.2% and 53.4%, respectively. For the 62 test cases, a total of 55 FPs were identified by radiologist in 23 of the cases. Conclusions: The authors’ MSCAR-RBG method achieved high sensitivity for coronary artery segmentation and tracking. Studies are underway to further improve the accuracy for the arterial segments affected by motion artifacts, severe calcified and noncalcified soft plaques, and to reduce the false tracking of the veins and other noisy structures. Methods are also being developed to detect coronary artery disease along the tracked vessels.

60 APPLIED LIFE SCIENCES↗

Volatiles from the necrophagous fly Cochliomyia macellaria (Diptera: Calliphoridae) as indicators of Salmonella exposure

Blow flies (Diptera: Calliphoridae) are crucial in forensic investigations due to their association with both living and dead humans and other animals. Additionally, their interactions with various resources and potential as vectors of pathogens of humans and other animals, thus, make them potential tools for biosurveillance. This study investigated the potential of monitoring volatile organic compounds (VOCs) emitted by blow flies exposed to Salmonella as a method for pathogen surveillance. Adult blow flies ( Cochliomyia macellaria ) were exposed, or not, to Salmonella enterica . Following exposure, VOCs released by the blow flies were collected and analyzed using gas chromatography-mass spectrometry (GC-MS). Results indicate a treatment by time interaction (P < 0.01). Indicator species analysis identified a single compound significantly associated with S. enterica exposure (P = 0.02), Nonane, 2,2,4,4,6,8,8-heptamethyl, potentially indicating an immune system response. Given a compound indicating exposure was detected, future research should determine if more replicates could detect more differences after Salmonella ingestion. This research highlights the potential of blow flies as biosurveillance tools and the potential value of volatiles for assessing their exposure to pathogens.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of the Prostate Bed for Local Recurrence After Radical Prostatectomy Using Endorectal Magnetic Resonance Imaging

Purpose: To summarize the results of a 4-year period in which endorectal magnetic resonance imaging (MRI) was considered for all men referred for salvage radiation therapy (RT) at a single academic center; to describe the incidence and location of locally recurrent disease in a contemporary cohort of men with biochemical failure after radical prostatectomy (RP), and to identify prognostic variables associated with MRI findings in order to define which patients may have the highest yield of the study. Methods and Materials: Between 2007 and 2011, 88 men without clinically palpable disease underwent eMRI for detectable prostate-specific antigen (PSA) after RP. The median interval between RP and eMRI was 32 months (interquartile range, 14-57 months), and the median PSA level was 0.30 ng/mL (interquartile range, 0.19-0.72 ng/mL). Magnetic resonance imaging scans consisting of T2-weighted, diffusion-weighted, and dynamic contrast-enhanced imaging were evaluated for features consistent with local recurrence. The prostate bed was scored from 0-4, whereby 0 was definitely normal, 1 probably normal, 2 indeterminate, 3 probably abnormal, and 4 definitely abnormal. Local recurrence was defined as having a score of 3-4. Results: Local recurrence was identified in 21 men (24%). Abnormalities were best appreciated on T2-weighted axial images (90%) as focal hypointense lesions. Recurrence locations were perianastomotic (67%) or retrovesical (33%). The only risk factor associated with local recurrence was PSA; recurrence was seen in 37% of men with PSA >0.3 ng/mL vs 13% if PSA {<=}0.3 ng/mL (P<.01). The median volume of recurrence was 0.26 cm{sup 3} and was directly associated with PSA (r=0.5, P=.02). The correlation between MRI-based tumor volume and PSA was even stronger in men with positive margins (r=0.8, P<.01). Conclusions: Endorectal MRI can define areas of local recurrence after RP in a minority of men without clinical evidence of disease, with yield related to PSA. Further study is necessary to determine whether eMRI can improve patient selection and success of salvage RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Virtual monoenergetic reconstruction of contrast-enhanced CT scans of the abdomen and pelvis at 40 keV improves the detection of peritoneal metastatic deposits

Purpose: To evaluate the role of virtual monoenergetic imaging (VMI) in the detection of peritoneal metastatic disease in contrast-enhanced computed tomography (CT) of the abdomen and pelvis and to compare this technique to the conventional 120 kV mixed dataset. Materials and methods: Institutional review board approval was obtained with no informed consent required for this retrospective analysis. 43 consecutive patients with histopathologically confirmed peritoneal disease were scanned using a standard protocol on a 128-section dual-source, dual-energy CT system (100/140 keV). Scans were retrospectively reconstructed at VMI energy levels from 40–110 keV in 10 keV increments and were analyzed both quantitatively and qualitatively. CNR values for peritoneal metastatic deposits were recorded using region of interest (ROI) analysis at each energy level for all VMI datasets. Subjective analysis was performed by two independent fellowship-trained readers with combined experience of greater than 15 years. Qualitative parameters included diagnostic acceptability, subjective noise, and contrast resolution and confidence. Results: The contrast-to-noise ratios (CNRs) for peritoneal metastatic deposits at the different VMI energy levels were compared using a one-way ANOVA with Tukey Post Test, and the optimal CNR was observed at 40 keV (p < 0.0001). Qualitative parameters were compared using a Paired T Test. Subjective noise, diagnostic acceptability, and contrast resolution was significantly better on the conventional images, but readers reported increased confidence on VMI at 40 keV (p < 0.001). Conclusion: VMI reconstruction of contrast-enhanced dual-energy CT scans of the abdomen and pelvis at 40 keV maximizes the conspicuity of metastatic peritoneal deposits and improves radiologists’ diagnostic confidence compared with conventional CT images. We recommend using virtual monoenergetic datasets at 40 keV as a tool for improving the detection of these lesions in routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The use of remote sensors to relate biological and physical indicators to environmental and public health problems

Relationships between biological, ecological and botanical structures, and disease organisms and their vectors which might be detected and measured by remote sensing are determined. In addition to the use of trees as indicators of disease or potential disease, an attempt is made to identify environmental factors such as soil moisture and soil and water temperatures as they relate to disease or health problems and may be detected by remote sensing. The following three diseases and one major health problem are examined: Malaria, Rocky Mountain spotted fever, Encephalitis and Red Tide. It is shown that no single species of vascular plant nor any one environmental factor can be used as the indicator of disease or health problems. Entire vegetation types, successional stages and combinations of factors must be used.

Source record↗