Search NASA⌕ Search

SEARCH · Search NASA

Results for “DYNAMICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Efficient estimators for likelihood ratio sensitivity indices of complex stochastic dynamics

We demonstrate that centered likelihood ratio estimators for the sensitivity indices of complex stochastic dynamics are highly efficient with low, constant in time variance and consequently they are suitable for sensitivity analysis in long-time and steady-state regimes. These estimators rely on a new covariance formulation of the likelihood ratio that includes as a submatrix a Fisher information matrix for stochastic dynamics and can also be used for fast screening of insensitive parameters and parameter combinations. The proposed methods are applicable to broad classes of stochastic dynamics such as chemical reaction networks, Langevin-type equations and stochastic models in finance, including systems with a high dimensional parameter space and/or disparate decorrelation times between different observables. Furthermore, they are simple to implement as a standard observable in any existing simulation algorithm without additional modifications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental investigations of ablation stream interaction dynamics in tungsten wire arrays: Interpenetration, magnetic field advection, and ion deflection

Experiments have been carried out to investigate the collisional dynamics of ablation streams produced by cylindrical wire array z-pinches. A combination of laser interferometric imaging, Thomson scattering, and Faraday rotation imaging has been used to make a range of measurements of the temporal evolution of various plasma and flow parameters. This paper presents a summary of previously published data, drawing together a range of different measurements in order to give an overview of the key results. The paper focuses mainly on the results of experiments with tungsten wire arrays. Early interferometric imaging measurements are reviewed, then more recent Thomson scattering measurements are discussed; these measurements provided the first direct evidence of ablation stream interpenetration in a wire array experiment. Combining the data from these experiments gives a view of the temporal evolution of the tungsten stream collisional dynamics. In the final part of the paper, we present new experimental measurements made using an imaging Faraday rotation diagnostic. These experiments investigated the structure of magnetic fields near the array axis directly; the presence of a magnetic field has previously been inferred based on Thomson scattering measurements of ion deflection near the array axis. Although the Thomson and Faraday measurements are not in full quantitative agreement, the Faraday data do qualitatively supports the conjecture that the observed deflections are induced by a static toroidal magnetic field, which has been advected to the array axis by the ablation streams. It is likely that detailed modeling will be needed in order to fully understand the dynamics observed in the experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anharmonic densities of states: A general dynamics-based solution

Density of states is a fundamental physical characteristic that lies at the foundation of statistical mechanics and theoretical constructs that derive from them (e.g., kinetic rate theories, phase diagrams, and others). Even though most real physical systems are anharmonic, the vibrational density of states is customarily treated within the harmonic approximation, or with some partial, often limited, account for anharmonicity. The reason for this is that the problem of anharmonic densities of states stubbornly resisted a general and exact, yet convenient and straightforward in applications, solution. Here we formulate such a solution within both classical and quantum mechanics. It is based on actual dynamical behavior of systems as a function of energy and as observed, or monitored, on a chosen time scale, short or long. As a consequence, the resulting anharmonic densities of states are fully dynamically informed and, in general, time-dependent. As such, they lay the ground for formulation of new statistical mechanical frameworks that incorporate time and are ergodic, by construction, with respect to actual dynamical behavior of systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the accuracy of the MB-pol many-body potential for water: Interaction energies, vibrational frequencies, and classical thermodynamic and dynamical properties from clusters to liquid water and ice

The MB-pol many-body potential has recently emerged as an accurate molecular model for water simulations from the gas to the condensed phase. In this study, the accuracy of MB-pol is systematically assessed across the three phases of water through extensive comparisons with experimental data and high-level ab initio calculations. Individual many-body contributions to the interaction energies as well as vibrational spectra of water clusters calculated with MB-pol are in excellent agreement with reference data obtained at the coupled cluster level. Several structural, thermodynamic, and dynamical properties of the liquid phase at atmospheric pressure are investigated through classical molecular dynamics simulations as a function of temperature. The structural properties of the liquid phase are in nearly quantitative agreement with X-ray diffraction data available over the temperature range from 268 to 368 K. The analysis of other thermodynamic and dynamical quantities emphasizes the importance of explicitly including nuclear quantum effects in the simulations, especially at low temperature, for a physically correct description of the properties of liquid water. Furthermore, both densities and lattice energies of several ice phases are also correctly reproduced by MB-pol. Following a recent study of DFT models for water, a score is assigned to each computed property, which demonstrates the high and, in many respects, unprecedented accuracy of MB-pol in representing all three phases of water. Published by AIP Publishing.

Reddy, Sandeep K. (ORCID:0000000214586853)↗

Performance of ePix10K, a high dynamic range, gain auto-ranging pixel detector for FELs

ePix10K is a hybrid pixel detector developed at SLAC for demanding free-electron laser (FEL) applications, providing an ultrahigh dynamic range (245 eV to 88 MeV) through gain auto-ranging. It has three gain modes (high, medium and low) and two auto-ranging modes (high-to-low and medium-to-low). The first ePix10K cameras are built around modules consisting of a sensor flip-chip bonded to 4 ASICs, resulting in 352 × 384 pixels of 100 µm x 100 µm each. We present results from extensive testing of three ePix10K cameras with FEL beams at LCLS, resulting in a measured noise floor of 245 eV rms, or 67 e - equivalent noise charge (ENC), and a range of 11 000 photons at 8 keV. We demonstrate the linearity of the response in various gain combinations: fixed high, fixed medium, fixed low, auto-ranging high to low, and auto-ranging medium-to-low, while maintaining a low noise (well within the counting statistics), a very low cross-talk, perfect saturation response at fluxes up to 900 times the maximum range, and acquisition rates of up to 480 Hz. Finally, we present examples of high dynamic range x-ray imaging spanning more than 4 orders of magnitude dynamic range (from a single photon to 11 000 photons/pixel/pulse at 8 keV). Achieving this high performance with only one auto-ranging switch leads to relatively simple calibration and reconstruction procedures. The low noise levels allow usage with long integration times at non-FEL sources. ePix10K cameras leverage the advantages of hybrid pixel detectors with high production yield and good availability, minimize development complexity through sharing the hardware, software and DAQ development with all other versions of ePix cameras, while providing an upgrade path to 5 kHz, 25 kHz and 100 kHz in three steps over the next few years, matching the LCLS-II requirements.

47 OTHER INSTRUMENTATION↗

Measurements of dynamic surface changes by digital holography for in situ plasma erosion applications

There are currently few viable diagnostic techniques for in situ measurement of plasma facing component erosion. Digital holography is intended to fill this gap. Progress on the development of single and dual CO 2 laser digital holography diagnostics for in situ plasma facing component erosion is discussed. The dual laser mode’s synthetic wavelength allows the measurable range to be expanded by a factor of ~400 compared to single laser digital holography. This allows the diagnostic to measure surface height changes of up to 4.5 μm in single laser mode and up to 2 mm in dual laser mode. Results include ex situ measurements of plasma eroded targets and also dynamic measurements of nm and μm scale motion of a target mounted on a precision translation stage. Dynamic measurements have successfully been made with the system operating in both single and dual laser modes, from ~50 nm to ~4 μm in single laser mode and up to ~400 μm in dual laser mode (limited only by the stage speed and camera acquisition duration). These results demonstrate the feasibility of using digital holography to characterize plasma facing component erosion dynamically, i.e., during plasma exposure. Results of proof-of-principle in situ digital holographic measurements of targets exposed to an electrothermal arc plasma source are presented.

Smith, Cary↗

A SURPRISING DYNAMICAL MASS FOR V773 Tau B

We report on new high-resolution imaging and spectroscopy on the multiple T Tauri star system V773 Tau over the 2003-2009 period. With these data we derive relative astrometry, photometry between the A and B components, and radial velocity (RV) of the A-subsystem components. Combining these new data with previously published astrometry and RVs, we update the relative A-B orbit model. This updated orbit model, the known system distance, and A-subsystem parameters yield a dynamical mass for the B component for the first time. Remarkably, the derived B dynamical mass is in the range 1.7-3.0 M{sub Sun }. This is much higher than previous estimates and suggests that like A, B is also a multiple stellar system. Among these data, spatially resolved spectroscopy provides new insight into the nature of the B component. Similar to A, these near-IR spectra indicate that the dominant source in B is of mid-K spectral type. If B is in fact a multiple star system as suggested by the dynamical mass estimate, the simplest assumption is that B is composed of similar {approx}1.2 M{sub Sun} pre-main-sequence stars in a close (<1 AU) binary system. This inference is supported by line-shape changes in near-IR spectroscopy of B, tentatively interpreted as changing RV among components in V773 Tau B. Relative photometry indicates that B is highly variable in the near-IR. The most likely explanation for this variability is circum-B material resulting in variable line-of-sight extinction. The distribution of this material must be significantly affected by both the putative B multiplicity and the A-B orbit.

79 ASTRONOMY AND ASTROPHYSICS↗

Fission dynamics of 240Pu from saddle to scission and beyond

Calculations are presented for the time evolution of 240 Pu from the proximity of the outer saddle point until the fission fragments are well separated, using the time-dependent density functional theory extended to superfluid systems. We have tested three families of nuclear energy density functionals and found that all functionals exhibit a similar dynamics: The collective motion is highly dissipative and with little trace of inertial dynamics, due to the one-body dissipation mechanism alone. This finding justifies the validity of using the overdamped collective motion approach and to some extent the main assumptions in statistical models of fission. This conclusion is robust with respect to the nuclear energy density functional used. The configurations and interactions left out of the present theory framework only increase the role of the dissipative couplings. An unexpected finding is varying the pairing strength within a quite large range has only minor effects on the dynamics. We find notable differences in the excitation energy sharing between the fission fragments in the cases of spontaneous and induced fission. With increasing initial excitation energy of the fissioning nucleus, more excitation energy is deposited in the heavy fragment, in agreement with experimental data on average neutron multiplicities.

Bulgac, Aurel↗

Novel transition dynamics of topological solitons

Continuous phase transitions can be classified into ones characterized by local-order parameters and others that need additional topological constraints. The critical dynamics near the former transitions have been extensively studied, but the latter is less understood. We fill this gap in knowledge by studying the transition dynamics to a parity-breaking topological ground state called the chiral soliton lattice in quantum chromodynamics at finite temperature, baryon chemical potential, and an external magnetic field. We find a slowing down of the soliton’s translational motion as the critical magnetic field approaches, while the local relaxation rate to the solitonic state remains finite. The time required to converge to the stationary state strongly depends on the symmetry of the initial configuration, determining whether translational motion occurs during the dynamic process. Published by the American Physical Society 2024

Nishimura, Kentaro↗

DynaM: Dynamic Multiresolution Data Representation for Large-Scale Scientific Analysis

Fast growing large-scale systems enable scientific applications to run at a much larger scale and accordingly produce gigantic volumes of simulation output. Such data imposes a grand challenge to post-processing tasks such as visualization and data analysis, because these tasks are often performed at a host machine that is remotely located and equipped with much less memory and storage resources. During the simulation runs, it is also desirable for scientists to be able to interactively monitor and steer the progress of simulation. This requires scientific data to be represented in an efficient form for initial exploration and computation steering. In this paper, we propose DynaM a software framework that can represent scientific data in a multiresolution form, and dynamically organize data blocks into an optimized layout for efficient scientific analysis. DynaM supports a convolution-based multiresolution data representation for abstracting scientific data for visualization at a wide spectrum of resolution. To support the efficient generation and retrieval of different data granularities from such representation, a dynamic data organization in DynaM is enabled to cater distinct peculiarities of different size data blocks for efficient and balanced I/O performance. Our experimental results demonstrate that DynaM can efficiently represent large scientific dataset and speed up the visualization of multidimensional scientific data. An up to 29 times speedup is achieved on Jaguar supercomputer at Oak Ridge National Laboratory.

Tian, Yuan↗

Regression-Based Analytics for Response Dynamics of SDN Solutions and Components

We consider Software-Defined Network (SDN) solutions that dynamically setup and teardown connections, and also their response dynamics of connectivity and TCP throughput. There is a wide variety of choices for controllers, switches, andsoftware modules, and objective analytics of measurements are needed to compare the response dynamics of solutions based on their combinations. Throughput and ping measurements during connection changes contain significant statistical variations due to the complexities of controllers, northbound scripts, and network devices. We propose analytical methods to estimate response regression functions, which provide a rigorous and objective comparison of different SDN solutions and their components, namely, controllers, switches, and OpenFlow versions. We apply this approach in two scenarios: (a) switching of long-haul connections emulated in hardware by ANUE devices over a testbed consisting of HP and Cisco switches, and (b) multi-site science infrastructure emulated using VMs and Mininet. The results provide useful practical insights including: (i) the dpctl method responds seconds faster than the OpenDayLight (ODL) method on average under OpenFlow 1.0, but performs similar to ODL under OpenFlow 1.3, and (ii) the ping response of dpctl is about 0.6 sec faster than ODL for the second scenario.

97 MATHEMATICS AND COMPUTING↗

Faster than Real-Time Dynamic Simulation for Large-Size Power System with Detailed Dynamic Models using High-Performance Computing Platform

This paper presents a faster-than-real-time dynamic simulation software package that is designed for large-size power system dynamic simulation. It was developed on the GridPACKTM high-performance computing (HPC) framework. The key features of the developed software package include (1) faster-than-real-time dynamic simulation for a WECC system (17,000 buses) with different types of detailed generator, controller, and relay dynamic models, (2) a decoupled parallel dynamic simulation algorithm with optimized computation architecture to better leverage HPC resources and technologies, (3) options for HPC-based linear and iterative solvers, (4) hidden HPC details, such as data communication and distribution, to enable development centered on mathematical models and algorithms rather than on computational details for power system researchers, and (5) easy integration of new dynamic models and related algorithms into the software package.

Huang, Renke↗

Simulation of Inrush Dynamics for Unbalanced Distribution Systems using Phasor Dynamics

Microgrids are a possible solution to mitigate the extensive interruptions in service to end-use customers caused by abnormal events, such as major natural disasters. Microgrids can be formed by energizing portions of the distribution system to interconnect generator and critical loads. In this scenario, inrush dynamic currents can present a barrier for forming microgrids by preventing the necessary switching operations and/or damaging equipment. Modeling inrush dynamics, through electromagnetic transient tools, presents a challenge when the microgrid represents a large portion of a distribution feeder. This paper uses a phasor dynamics approach to approximate the envelope of inrush dynamics, thus allowing simulations of large systems. The two main contributions of this paper are: a) a new formulation to solve a set of phasor-dynamic differential equations representing an unbalanced distribution system; and b) modeling of transformer saturation in the phasor-dynamics frame. These two contributions allow the in-rush phenomena to be simulated on full size microgrid and/or distribution feeder models. The new formulation and model are implemented in GridLAB-D, and tested on IEEE test systems.

inrush, GridLAB-D, distribution analysis, microgri↗

The State of the Art in Visualizing Dynamic Multivariate Networks

Abstract Most real‐world networks are both dynamic and multivariate in nature, meaning that the network is associated with various attributes and both the network structure and attributes evolve over time. Visualizing dynamic multivariate networks is of great significance to the visualization community because of their wide applications across multiple domains. However, it remains challenging because the techniques should focus on representing the network structure, attributes and their evolution concurrently. Many real‐world network analysis tasks require the concurrent usage of the three aspects of the dynamic multivariate networks. In this paper, we analyze current techniques and present a taxonomy to classify the existing visualization techniques based on three aspects: temporal encoding, topology encoding, and attribute encoding. Finally, we survey application areas and evaluation methods; and discuss challenges for future research.

Kale, Bharat↗

Perspective: Nonequilibrium dynamics of localized and delocalized excitons in colloidal quantum dot solids

Self-assembled quantum dot (QD) solids are a highly tunable class of materials with a wide range of applications in solid-state electronics and optoelectronic devices. In this perspective, the authors highlight how the presence of microscopic disorder in these materials can influence their macroscopic optoelectronic properties. Specifically, they consider the dynamics of excitons in energetically disordered QD solids using a theoretical model framework for both localized and delocalized excitonic regimes. In both cases, they emphasize the tendency of energetic disorder to promote nonequilibrium relaxation dynamics and discuss how the signatures of these nonequilibrium effects manifest in time-dependent spectral measurements. Moreover, they describe the connection between the microscopic dynamics of excitons within the material and the measurement of material specific parameters, such as emission linewidth broadening and energetic dissipation rate.

solar (photovoltaic), solid state lighting, photos↗

Development of a dynamic flow imaging phantom for dynamic contrast-enhanced CT

Purpose: Dynamic contrast enhanced CT (DCE-CT) studies with modeling of blood flow and tissue perfusion are becoming more prevalent in the clinic, with advances in wide volume CT scanners allowing the imaging of an entire organ with sub-second image frequency and sub-millimeter accuracy. Wide-spread implementation of perfusion DCE-CT, however, is pending fundamental validation of the quantitative parameters that result from dynamic contrast imaging and perfusion modeling. Therefore, the goal of this work was to design and construct a novel dynamic flow imaging phantom capable of producing typical clinical time-attenuation curves (TACs) with the purpose of developing a framework for the quantification and validation of DCE-CT measurements and kinetic modeling under realistic flow conditions. Methods: The phantom is based on a simple two-compartment model and was printed using a 3D printer. Initial analysis of the phantom involved simple flow measurements and progressed to DCE-CT experiments in order to test the phantoms range and reproducibility. The phantom was then utilized to generate realistic input TACs. A phantom prediction model was developed to compute the input and output TACs based on a given set of five experimental (control) parameters: pump flow rate, injection pump flow rate, injection contrast concentration, and both control valve positions. The prediction model is then inversely applied to determine the control parameters necessary to generate a set of desired input and output TACs. A protocol was developed and performed using the phantom to investigate image noise, partial volume effects and CT number accuracy under realistic flow conditionsResults: This phantom and its surrounding flow system are capable of creating a wide range of physiologically relevant TACs, which are reproducible with minimal error between experiments ({sigma}/{mu} < 5% for all metrics investigated). The dynamic flow phantom was capable of producing input and output TACs using either step function based or typical clinical arterial input function (AIF) inputs. The measured TACs were in excellent agreement with predictions across all comparison metrics with goodness of fit (R{sup 2}) for the input function between 0.95 and 0.98, while the maximum enhancement differed by no more than 3.3%. The predicted output functions were similarly accurate producing R{sup 2} values between 0.92 and 0.99 and maximum enhancement to within 9.0%. The effect of ROI size on the arterial input function (AIF) was investigated in order to determine an operating range of ROI sizes which were minimally affected by noise for small dimensions and partial volume effects for large dimensions. It was possible to establish the measurement sensitivity of both the Toshiba (ROI radius range from 1.5 to 3.2 mm ''low dose'', 1.4 to 3.0 mm ''high dose'') and GE scanner (1.5 to 2.6 mm ''low dose'', 1.1 to 3.4 mm ''high dose''). This application of the phantom also provides the ability to evaluate the effect of the AIF error on kinetic model parameter predictions. Conclusions: The dynamic flow imaging phantom is capable of producing accurate and reproducible results which can be predicted and quantified. This results in a unique tool for perfusion DCE-CT validation under realistic flow conditions which can be applied not only to compare different CT scanners and imaging protocols but also to provide a ground truth across multimodality dynamic imaging given its MRI and PET compatibility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗