Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Alternative Fuels Data Center

This presentation provides an overview of the Alternative Fuels Data Center for the 2026 Transportation Technologies Annual Merit Review, including project objectives, milestone, approach to developing and maintaining the website, project accomplishments and progress, and collaboration with other national labs and external partners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Guidelines for submitting data to the National Space Science Data Center

The mission of the National Space Science Data Center (NSSDC) is to disseminate space science data for further analysis beyond that provided by the principal investigators (PIs) or team leaders (TLs) and their coworkers. Consequently, the NSSDC is responsible for the acquisition, organization, storage, retrieval, announcement, and distribution of scientific data obtained mainly from satellites and spacecraft. Any scientist may acquired data from the NSSDC and use them in further studies, either alone or in conjunction with data from ground-based or spacecraft experiments. With the responsibility for archiving data is the concomitant responsibility for distributing the documentation necessary to make those data usable. Since the group most knowledgeable about a particular experiment and its data is the PI or TL and his coworkers, and since the NSSDC cannot possibly supply the qualified personnel needed to write this documentation comprehensively, it is the responsibility of the PI or TL to provide the essential documentation. The NSSDC will support this effort by defining what is needed, by reviewing what is provided, and by reproducing and distributing the resulting documentation with the data. For a high-use data set, the NSSDC may publish the documentation as a Data Users Note; for a low-use data set, the NSSDC may distribute a Xerox, microfilm, or microfiche copy of the documentation.

Source record↗

Optically connected memory for disaggregated data centers

Recent advances in integrated photonics enable the implementation of reconfigurable, high-bandwidth, and low energy-per-bit interconnects in next-generation data centers. We propose and evaluate an Optically Connected Memory (OCM) architecture that disaggregates the main memory from the computation nodes in data centers. OCM is based on micro-ring resonators (MRRs), and it does not require any modification to the DRAM memory modules. We calculate energy consumption from real photonic devices and integrate them into a system simulator to evaluate performance. Here, our results show that (1) OCM is capable of interconnecting four DDR4 memory channels to a computing node using two fibers with 1.02 pJ energy-per-bit consumption and (2) OCM performs up to 5.5× faster than a disaggregated memory with 40G PCIe NIC connectors to computing nodes.

97 MATHEMATICS AND COMPUTING↗

Energy Performance Testing of Asetek's RackCDU System at NREL's High Performance Computing Data Center

In this study, we report on the first tests of Asetek's RackCDU direct-to-chip liquid cooling system for servers at NREL's ESIF data center. The system was simple to install on the existing servers and integrated directly into the data center's existing hydronics system. The focus of this study was to explore the total cooling energy savings and potential for waste-heat recovery of this warm-water liquid cooling system. RackCDU captured up to 64% of server heat into the liquid stream at an outlet temperature of 89 degrees F, and 48% at outlet temperatures approaching 100 degrees F. This system was designed to capture heat from the CPUs only, indicating a potential for increased heat capture if memory cooling was included. Reduced temperatures inside the servers caused all fans to reduce power to the lowest possible BIOS setting, indicating further energy savings potential if additional fan control is included. Preliminary studies manually reducing fan speed (and even removing fans) validated this potential savings but could not be optimized for these working servers. The Asetek direct-to-chip liquid cooling system has been in operation with users for 16 months with no necessary maintenance and no leaks.

97 MATHEMATICS AND COMPUTING↗

A New Fast Fluid Dynamics Model for Data-Center Floor Plenums

A raised-floor plenum is often used to distribute cooling airflow in data centers. Traditional Computational Fluid Dynamics (CFD) can accurately model airflow distribution in plenums, but it is expensive (computationally and financially) and is, therefore, often not accessible to the data center designer or operator. This paper presents an alternative CFD methodology based on Fast Fluid Dynamics (FFD), which is faster, more parallelizable, and simpler to program. The improvement in computational speed afforded by FFD is particularly important for multiple-iteration optimization, transient simulations, or applications for which near-real-time performance is required. Here, the potential speed improvements of FFD have been widely documented; however, it has been generally accepted that this benefit is accompanied by a modest loss of accuracy relative to traditional CFD. We show here that this is not necessarily true. Plenum airflow predictions by our FFD implementation, which utilizes a first-order upwind rather than Semi-Lagrangian advection scheme of previous research, are extremely close to those predicted by traditional CFD - provided the same turbulence model and computational grid are used consistently.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NREL Data Center Cuts Water Use in Half With Hybrid Thermosyphon System

In 2016, NREL installed a thermosyphon hybrid cooling system to reduce water use in the already extremely energy efficient data center at the Energy Systems Integration Facility. In this video, NREL Computational Science Center Director Steve Hammond describes how the system has successfully cut onsite water use in half without negative impacts to the data center’s energy efficient operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LANL HPC Data Center Monitoring (Summer 2022 Talk) [Slides]

HPC Monitoring is tasked with the understanding of everything that happens in the Data Center. They get to that understanding by: collecting logs and metrics, processing data, analyzing data, displaying information, and receiving alerts on events. Their ultimate (and probably unreachable) goal is a holistic view of the Data Center and an understanding of how everything is correlated.

97 MATHEMATICS AND COMPUTING↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Progress of Covariance Evaluation at the China Nuclear Data Center

Covariance evaluations at the China Nuclear Data Center focus on the cross sections of structural materials and actinides in the fast neutron energy range. In addition to the well-known Least-squares approach, a method based on the analysis of the sources of experimental uncertainties is especially introduced to generate a covariance matrix for a particular reaction for which multiple measurements are available. The scheme of the covariance evaluation flow is presented, and an example of n+{sup 90}Zr is given to illuminate the whole procedure. It is proven that the accuracy of measurements can be properly incorporated into the covariance and the long-standing small uncertainty problem can be avoided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Toward higher-radix switches with co-packaged optics for improved network locality in data center and HPC networks [Invited]

In this work, we study the network locality improvements that can be achieved by using co-packaged optics in data center and high-performance computing (HPC) networks. The increased escape bandwidth offered by co-packaged optics can enable switches with speeds of 51.2 Tb/s and beyond. From a network architecture perspective, the key advantages of introducing co-packaged optics at the switch points include the implementation of large-scale topologies of >12,000 end points with 4× higher bisection bandwidth and the reduction of the required number of switches by >40% compared with state-of-the-art approaches. From a network operation perspective, improved network locality and faster operation can be achieved since the higher-radix switches can mitigate the impact of network contention. Placing applications under fewer leaf switches reduces the number of packets that cross the spine switches in a leaf-spine topology. The proposed scheme is evaluated via discrete-event simulations: we initially evaluate the network locality properties of the system by using virtual-machine traces from a production data center, and we subsequently quantify the performance improvements by simulating an all-to-all pattern for a variety of message sizes over a number of nodes. The results suggest that co-packaged optics form a promising solution for keeping up with bandwidth scaling in future networks. The virtual-machine analysis shows that large-scale applications can be placed under up to 50% fewer first-level switches, while the network analysis shows speedups of up to 7.1, which translates to execution time reductions of up to 26% and 42.7% for applications with communication ratios of 0.3 and 0.5, respectively.

99 GENERAL AND MISCELLANEOUS↗

Guide to Minimizing Compressor-based Cooling in Data Centers

This best practice guide is one in a series created by the Lawrence Berkeley National Laboratory for the Federal Energy Management Program (FEMP), a program of the U.S. Department of Energy. Geared towards architects, engineers, and data center Information Technology (IT) and facility managers, this guide provides information about technologies and practices to use in designing, constructing, and operating sustainable high-performance data centers.

Guide, Minimizing, Compressor-based, Cooling, Data↗

NASA’s Atmospheric Science Data Center’s Approach to a Cloud-Based Model of Ingest, Archival, and Distribution of TEMPO Data: Methods, Challenges, and Best Practices

The National Aeronautics and Space Administration's (NASA) Atmospheric Science Data Center (ASDC) at NASA Langley Research Center in Hampton, VA provides atmospheric science data products and services to the science community, including enhanced search and subsetting capabilities for numerous datasets. The ASDC is the official Distributed Active Archive Center (DAAC) of record for the upcoming Tropospheric Emissions: Monitoring of Pollution (TEMPO) instrument. TEMPO will be situated on a geostationary satellite positioned at a longitude near the center of the conterminous United States and focused on North America, making hourly swaths of its field of regard from east to west. ASDC’s data products are currently hosted locally and services (e.g., spatial and temporal subsetting) are managed on premises. The ASDC is planning to provide TEMPO data and services in the cloud through the Earthdata Search platform. This presentation will discuss the ASDC’s approach to a cloud-based model of ingest, archival, and distribution of TEMPO data. Methods, challenges, best practices, lessons learned, and future plans will be discussed.

Iman Nasif↗

Energy Use in Quantum Data Centers: Scaling the Impact of Computer Architecture, Qubit Performance, Size, and Thermal Parameters

As quantum computers increase in size, the total energy used by a quantum data center, including the cooling, will become a greater concern. The cooling requirements of quantum computers, which operate at temperatures near absolute zero, are determined by computing system parameters, including the number and type of physical qubits, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. When combined with thermal system parameters such as cooling efficiency and cryostat heat transfer, the total energy use can be determined using a first-principles energy model. These models show that cooling of quantum computers differs in two fundamental ways from conventional data centers: (1) the energy required for cooling is much greater than the energy required for computation, and (2) the cooling loads are sensitive to the computational architecture. The temperature requirements for different qubit types can change energy requirements by orders of magnitude. Power use and computational power, as quantified by quantum volume, are analytically correlated. Approaches are identified for minimizing energy use in integrated quantum systems relative to computational power. Furthermore, designing a sustainable quantum computer will require both efficient cooling and system design that minimizes cooling requirements.

97 MATHEMATICS AND COMPUTING↗

Fusion and Fission Energy and Science Directorate and Information Technology Services Directorate HPC Cluster Reduction, Consolidation, and Savings in Data Center Space, Power, and Cooling

This report evaluates the benefits of decommissioning six legacy FFESD purchased HPC clusters and consolidating services and workloads into a new HPC cluster named HELIOS. The findings demonstrate significant reductions in the data center power and cooling requirements, data center footprint, and operational overhead, while simultaneously increasing computational capacity.

97 MATHEMATICS AND COMPUTING↗