Impedance Discontinuity Reduction Between High-Speed Differential Connectors and PCB Interfaces

High-speed serial communication (i.e., Gigabit Ethernet) requires differential transmission and controlled impedances. Impedance control is essential throughout cabling, connector, and circuit board construction. An impedance discontinuity arises at the interface of a high-speed quadrax and twinax connectors and the attached printed circuit board (PCB). This discontinuity usually is lower impedance since the relative dielectric constant of the board is higher (i.e., polyimide approx. = 4) than the connector (Teflon approx. = 2.25). The discontinuity can be observed in transmit or receive eye diagrams, and can reduce the effective link margin of serial data networks. High-speed serial data network transmission improvements can be made at the connector-to-board interfaces as well as improving differential via hole impedances. The impedance discontinuity was improved by 10 percent by drilling a 20-mil (approx. = 0.5-mm) hole in between the pin of a differential connector spaced 55 mils (approx. = 1.4 mm) apart as it is attached to the PCB. The effective dielectric constant of the board can be lowered by drilling holes into the board material between the differential lines in a quadrax or twinax connector attachment points. The differential impedance is inversely proportional to the square root of the relative dielectric constant. This increases the differential impedance and thus reduces the above described impedance discontinuity. The differential via hole impedance can also be increased in the same manner. This technique can be extended to multiple smaller drilled holes as well as tapered holes (i.e., big in the middle followed by smaller ones diagonally).

Navidi, Sal↗

Guanine Oxidation in the Genome, not RNA Editing, Accounts for Single Nucleotide Variation in the Exome of Mice Flown on Board the ISS

We have conducted a further analysis of single nucleotide variation (somatic mutation) in mice flown aboard the ISS. We used data archived in GeneLab from a cohort of 18-week-old mice were flown to the ISS, housed in the Rodent Habitat and therefore subjected to microgravity for 37 days. Mice of similar age, sex and the same strain were used for ground controls housed in identical hardware and simulating, but not matching ISS environmental conditions (temperature, humidity and gas atmosphere). Primary data consists of next generation RNA sequencing for the tissues examined: eye, liver, skeletal muscle and kidney. We used novel software, developed at NASA Ames Research Center and deployed on the NASA Ames Supercomputer, to perform variant calling for single point mutations. Unexpectedly, we discovered a high degree of somatic mutation in ISS-flown mice, compared to controls. We found that the extent of somatic mutation correlated with the degree of gene expression in the four tissue types, with the highest degree of somatic mutation observed in genes with the highest degree of expression. Careful analysis that included measurement of specific nucleotide changes that occurred demonstrated that guanine substitutions were the most frequent, consistent with the hypothesis that reactive oxygen species-mediated guanine oxidation was responsible for the hypermutation events. By contrast, adenine substitutions would be expected if gene editing were responsible for the somatic mutation. These types of substitutions were much less frequent. The implication of these findings for astronaut health in a variety of mission scenarios will be discussed.

International Space Station↗

Energy Use Intensity and its Influence on the Integrated Daylighting Design of a Large Net Zero Energy Building: Preprint

Net-zero energy buildings generate as much energy as they consume and are significant in the sustainable future of building design and construction. The role of daylighting (and its simulation) in the design process becomes critical. In this paper we present the process the National Renewable Energy Laboratory embarked on in the procurement, design, and construction of its newest building, theResearch Support Facility (RSF) - particularly the roles of daylighting, electric lighting, and simulation. With a rapid construction schedule, the procurement, design, and construction had to be tightly integrated; with low energy use. We outline the process and measures required to manage a building design that could expect to operate at an efficiency previously unheard of for a building ofthis type, size, and density. Rigorous simulation of the daylighting and the electric lighting control response was a given, but the oft-ignored disconnect between lighting simulation and whole-building energy use simulation had to be addressed. The RSF project will be thoroughly evaluated for its performance for one year; preliminary data from the postoccupancy monitoring efforts will also bepresented with an eye toward the current efficacy of building energy and lighting simulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detecting and Analyzing Multiple Moving Objects in Crowded Environments with Coherent Motion Regions

Understanding the world around us from large-scale video data requires vision systems that can perform automatic interpretation. While human eyes can unconsciously perceive independent objects in crowded scenes and other challenging operating environments, automated systems have difficulty detecting, counting, and understanding their behavior in similar scenes. Computer scientists at ORNL have a developed a technology termed as "Coherent Motion Region Detection" that invloves identifying multiple indepedent moving objects in crowded scenes by aggregating low-level motion cues extracted from moving objects. Humans and other species exploit such low-level motion cues seamlessely to perform perceptual grouping for visual understanding. The algorithm detects and tracks feature points on moving objects resulting in partial trajectories that span coherent 3D region in the space-time volume defined by the video. In the case of multi-object motion, many possible coherent motion regions can be constructed around the set of trajectories. The unique approach in the algorithm is to identify all possible coherent motion regions, then extract a subset of motion regions based on an innovative measure to automatically locate moving objects in crowded environments.The software reports snapshot of the object, count, and derived statistics ( count over time) from input video streams. The software can directly process videos streamed over the internet or directly from a hardware device (camera).

Cheriyadat, Anil M.↗

Saccades to remembered targets: the effects of smooth pursuit and illusory stimulus motion

1. Measurements were made in four normal human subjects of the accuracy of saccades to remembered locations of targets that were flashed on a 20 x 30 deg random dot display that was either stationary or moving horizontally and sinusoidally at +/-9 deg at 0.3 Hz. During the interval between the target flash and the memory-guided saccade, the "memory period" (1.4 s), subjects either fixated a stationary spot or pursued a spot moving vertically sinusoidally at +/-9 deg at 0.3 Hz. 2. When saccades were made toward the location of targets previously flashed on a stationary background as subjects fixated the stationary spot, median saccadic error was 0.93 deg horizontally and 1.1 deg vertically. These errors were greater than for saccades to visible targets, which had median values of 0.59 deg horizontally and 0.60 deg vertically. 3. When targets were flashed as subjects smoothly pursued a spot that moved vertically across the stationary background, median saccadic error was 1.1 deg horizontally and 1.2 deg vertically, thus being of similar accuracy to when targets were flashed during fixation. In addition, the vertical component of the memory-guided saccade was much more closely correlated with the "spatial error" than with the "retinal error"; this indicated that, when programming the saccade, the brain had taken into account eye movements that occurred during the memory period. 4. When saccades were made to targets flashed during attempted fixation of a stationary spot on a horizontally moving background, a condition that produces a weak Duncker-type illusion of horizontal movement of the primary target, median saccadic error increased horizontally to 3.2 deg but was 1.1 deg vertically. 5. When targets were flashed as subjects smoothly pursued a spot that moved vertically on the horizontally moving background, a condition that induces a strong illusion of diagonal target motion, median saccadic error was 4.0 deg horizontally and 1.5 deg vertically; thus the horizontal error was greater than under any other experimental condition. 6. In most trials, the initial saccade to the remembered target was followed by additional saccades while the subject was still in darkness. These secondary saccades, which were executed in the absence of visual feedback, brought the eye closer to the target location. During paradigms involving horizontal background movement, these corrections were more prominent horizontally than vertically. 7. Further measurements were made in two subjects to determine whether inaccuracy of memory-guided saccades, in the horizontal plane, was due to mislocalization at the time that the target flashed, misrepresentation of the trajectory of the pursuit eye movement during the memory period, or both. 8. The magnitude of the saccadic error, both with and without corrections made in darkness, was mislocalized by approximately 30% of the displacement of the background at the time that the target flashed. The magnitude of the saccadic error also was influenced by net movement of the background during the memory period, corresponding to approximately 25% of net background movement for the initial saccade and approximately 13% for the final eye position achieved in darkness. 9. We formulated simple linear models to test specific hypotheses about which combinations of signals best describe the observed saccadic amplitudes. We tested the possibilities that the brain made an accurate memory of target location and a reliable representation of the eye movement during the memory period, or that one or both of these was corrupted by the illusory visual stimulus. Our data were best accounted for by a model in which both the working memory of target location and the internal representation of the horizontal eye movements were corrupted by the illusory visual stimulus. We conclude that extraretinal signals played only a minor role, in comparison with visual estimates of the direction of gaze, in planning eye movements to remembered targ.

Clinical Trial↗

Second-order statistical bootstrap for the uncertainty quantification of time-temperature-superposition analysis

Time-temperature superposition (TTS), which for decades has been a powerful method for long-term prediction from accelerated aging data, involves rigid-shifting isotherms in logarithmic time to produce a single master prediction curve. For simple thermo-rheological properties that accurately follow the TTS principle, the shifts can be easily determined, even manually by the eye. However, for many properties of interest, where the principle is obeyed only approximately, or the data is noisy, it is imperative to develop objective shifting techniques along with reliable uncertainty bounds. This work analyzes in detail the method of arclength-minimization as an unsupervised algorithm to determining optimum shifts and demonstrates that the method is nearly unbiased for all practical datasets with a variety of noise distributions. Moreover, if averaged over with-replacement (bootstrap) resamples, the predicted shifts follow a normal distribution, a fact that can be used to construct confidence interval for the master curve through a second-order bootstrap procedure.

36 MATERIALS SCIENCE↗

Quantitative EEG Monitoring of Vigilance: Effects of Sleep Deprivation, Circadian Phase and Sympathetic Activation

Shuttle astronauts typically sleep only 6 to 6.5 hours per day while in orbit. This sleep loss is related to recurrent sleep cycle shifting--due to mission-dependent orbital mechanics and mission duration requirements-- and associated circadian displacement of sleep, the operational demands of space flight, noise and space motion sickness. Such sleep schedules are known to produce poor subjective sleep quality, daytime sleepiness, reduced attention, negative mood, slower reaction times, and impaired daytime alertness. Countermeasures to allow crew members to obtain an adequate amount of sleep and maintain adequate levels of neurobehavioral performance are being developed and investigated. However, it is necessary to develop methods that allow effective and attainable in-flight monitoring of vigilance to evaluate the effectiveness of these countermeasures and to detect and predict online critical decrements in alertness/performance. There is growing evidence to indicate that sleep loss and associated decrements in neurobehavioral function are reflected in the spectral composition of the electroencephalogram (EEG) during wakefulness as well as in the incidence of slow eye movements recorded by the electro-oculogram (EOG). Further-more, our preliminary data indicated that these changes in the EEG during wakefulness are more pronounced when subjects are in a supine posture, which mimics some of the physiologic effects of microgravity. Therefore, we evaluate the following hypotheses: (1) that during a 40-hour period of wakefulness (i.e., one night of total sleep deprivation) neurobehavioral function deteriorates, the incidence of slow eye-movements and EEG power density in the theta frequencies increases especially in frontal areas of the brain; (2) that the sleep deprivation induced deterioration of neurobehavioral function and changes in the incidence of slow eye movements and the spectral composition of the EEG are more pronounced when subjects are in a supine position; and (3) that based on assessment of slow-eye movements and quantitative on-line topographical analyses of EEG during wakefulness an EEG and or EOG parameter can be derived/constructed which accurately predicts changes in neurobehavioral function.

Dijk, Derk-Jan↗

Spacelab Life Sciences 1, development towards successive life sciences flights

A general review is presented of flight data and related hardware developments for Spacelab Life Sciences (SLS) 1 with an eye toward applying this knowledge to projected flight planning. Specific attention is given to the Research Animal Holding Facility (RAHF), the General Purpose Work Station (GPWS), the Small Mass Measuring Instrument (SMMI), and the Animal Enclosure Module (AEM). Preflight and in-flight testing methods are detailed including biocompatibility tests, parametric engineering sensitivity analyses, measurements of environmental parameters, and studies of operational interfaces. Particulate containment is demonstrated for some of the equipment, and successful use of the GPWS, RAHF, AEM, and SMMI are reported. The in-flight data are useful for developing more advanced hardware such as the AEM for SLS flight 2 and the modified RAHF for SLS flight 3.

Dalton, B. P.↗

Conjunctival Autograft Alone or Combined With Adjuvant Beta-Radiation? A Randomized Clinical Trial

Purpose: To evaluate the effectiveness and safety of postoperative low single-dose of beta-irradiation ({beta}-RT) in pterygium comparing conjunctival autograft (CAG) surgery with CAG plus adjuvant {beta}-RT in a randomized clinical trial. Methods: This trial was designed as a prospective, randomized, single-center study. Surgery was performed in all cases according to the CAG technique. One hundred and eight pterygia were postoperatively randomized to CAG + {beta}-RT or CAG alone. In the case of {beta}-RT, a (90) Sr eye applicator was used to deliver 10 Gy to the sclera surface at a dose rate of between 200 and 250 cGy/min. After treatment, both an ophthalmologist and a radiation oncologist performed the follow-up examinations. The accumulated data were analyzed using a group sequential test. Results: Between February 2008 and September 2008, 116 eyes with primary pterygium were operated on according to the trial protocol. Adjuvant treatment was performed within 24 h postoperatively. Eight patients were lost to follow-up, resulting in 108 patients who could be analyzed. At a mean follow-up of 18 months (range, 8-33), in the 54 eyes randomized to receive CAG + {beta}-RT, 5 relapses occurred compared with 12 recurrences in the 54 eyes in CAG, for a crude control rate of 90.8 % vs. 78%; p = 0.032, respectively. The treatment complications as hyperemia, total dehiscence of the autograft and dellen were significantly more frequent in the CAG (p < 0.05). The arm of {beta}-RT resulted in better cosmetic results and improves of symptoms than CAG. Conclusions: A low single-dose of {beta}-RT of 10 Gy after CAG surgery was a simple, effective, and safe treatment that reduced the risk of primary pterygium recurrence, improved symptoms after surgery, resulting in a better cosmetic effect than only CAG.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Energy Differential Response of Cancer Cells for Low Dose Irradiation:Impact of Monoenergetic Brachytherapy Sources

Purpose: The purpose of this work was to evaluate the energy differential response of cancer cells under identical dose exposure to asses the relevancy of mono-energetic sources for Brachytherapy treatments. Method and Materials: An electron energy spectrum impinging on lived breast cancer cell lines (MDA321) was obtained by placing a 19.65 {micro}Ci {sup 90}Sr/{sup 90}Y radioactive source in front of a non-uniform magnetic field constructed from two 5.08 x 5.0 cm x 2.54 cm neodimium ion permanent dipole magnets with a 1 cm separation gap. The cell lines were placed on the exit pole face of the magnet and were subsequently irradiated with different electron energies ranging from about 0.75 MeV to 1.85 MeV. The energy distribution was accurately measured with a scintillating fiber detector system that provided a 0.5% agreement with ICRU and a 5% energy resolution. The dosimetry was performed using a series of data acquired with a {sup 9}Sr/{sup 90}Y 4.5 mCi SIA-6 eye applicator, 6-21 MeV fixed energies from a Varian 2100 EX linac, EBT Gafchromic and Kodak ERT2 films, and an ion chamber detector. The accuracy of the dose rate obtained at different locations along and away from the magnet inside the cell containers was within 10.7%. Results: The cell lines were irradiated with a 0.5-4 Gy dose range. The data indicate a very strong differential energy response for electrons around 1 MeV (more lethal) compare to those with lesser or greater energy and a survival rate of at most 10% at very low dose (0.5-2 Gy). Conclusion: Mono-energetic Brachytherapy sources may provide a new pathway for radio-therapy treatment optimizations following a dedicated study showing very unusual high lethality in a specific energy window for MDA321 breast cancer cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phenomenological study of the interplay between IR-improved DGLAP-CS theory and the precision of an NLO ME matched parton shower MC

We present a phenomenological study of the current status of the application of our approach of exact amplitude-based resummation in quantum field theory to precision QCD calculations, by realistic MC event generator methods, as needed for precision LHC physics. We discuss recent results as they relate to the interplay of the attendant IR-improved DGLAP-CS theory of one of us and the precision of exact NLO matrix-element matched parton shower MC’s in the Herwig6.5 environment as determined by comparison to recent LHC experimental observations on single heavy gauge boson production and decay. The level of agreement between the new theory and the data continues to be a reason for optimism. In the spirit of completeness, we discuss as well other approaches to the same theoretical predictions that we make here from the standpoint of physical precision with an eye toward the (sub-)1% QCD⊗EW total theoretical precision regime for LHC physics. - Highlights: • Using LHC data, we show that IR-improved DGLAP-CS kernels with exact NLO Shower/ME matching improves MC precision. • We discuss other possible approaches in comparison with ours. • We propose experimental tests to discriminate between competing approaches.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of smooth pursuit and combined eye-head tracking in human subjects with deficient labyrinthine function

The effects of deficient labyrinthine function on smooth visual tracking with the eyes and head were investigated, using ten patients with bilateral peripheral vestibular disease and ten normal controls. Active, combined eye-head tracking (EHT) was significantly better in patients than smooth pursuit with the eyes alone, whereas normal subjects pursued equally well in both cases. Compensatory eye movements during active head rotation in darkness were always less in patients than in normal subjects. These data were used to examine current hypotheses that postulate central cancellation of the vestibulo-ocular reflex (VOR) during EHT. A model that proposes summation of an integral smooth pursuit command and VOR/compensatory eye movements is consistent with the findings. Observation of passive EHT (visual fixation of a head-fixed target during en bloc rotation) appears to indicate that in this mode parametric gain changes contribute to modulation of the VOR.

Leigh, R. J.↗

MO-E-17A-08: Attenuation-Based Size Adjusted, Scanner-Independent Organ Dose Estimates for Head CT Exams: TG 204 for Head CT

Purpose: AAPM Task Group 204 described size specific dose estimates (SSDE) for body scans. The purpose of this work is to use a similar approach to develop patient-specific, scanner-independent organ dose estimates for head CT exams using an attenuation-based size metric. Methods: For eight patient models from the GSF family of voxelized phantoms, dose to brain and lens of the eye was estimated using Monte Carlo simulations of contiguous axial scans for 64-slice MDCT scanners from four major manufacturers. Organ doses were normalized by scannerspecific 16 cm CTDIvol values and averaged across all scanners to obtain scanner-independent CTDIvol-to-organ-dose conversion coefficients for each patient model. Head size was measured at the first slice superior to the eyes; patient perimeter and effective diameter (ED) were measured directly from the GSF data. Because the GSF models use organ identification codes instead of Hounsfield units, water equivalent diameter (WED) was estimated indirectly. Using the image data from 42 patients ranging from 2 weeks old to adult, the perimeter, ED and WED size metrics were obtained and correlations between each metric were established. Applying these correlations to the GSF perimeter and ED measurements, WED was calculated for each model. The relationship between the various patient size metrics and CTDIvol-to-organ-dose conversion coefficients was then described. Results: The analysis of patient images demonstrated the correlation between WED and ED across a wide range of patient sizes. When applied to the GSF patient models, an exponential relationship between CTDIvol-to-organ-dose conversion coefficients and the WED size metric was observed with correlation coefficients of 0.93 and 0.77 for the brain and lens of the eye, respectively. Conclusion: Strong correlation exists between CTDIvol normalized brain dose and WED. For the lens of the eye, a lower correlation is observed, primarily due to surface dose variations. Funding Support: Siemens-UCLA Radiology Master Research Agreement; Disclosures - Michael McNitt-Gray: Institutional Research Agreement, Siemens AG; Research Support, Siemens AG; Consultant, Flaherty Sensabaugh Bonasso PLLC; Consultant, Fulbright and Jaworski.

60 APPLIED LIFE SCIENCES↗

Omniview motionless camera orientation system

An apparatus and method is provided for converting digital images for use in an imaging system. The apparatus includes a data memory which stores digital data representing an image having a circular or spherical field of view such as an image captured by a fish-eye lens, a control input for receiving a signal for selecting a portion of the image, and a converter responsive to the control input for converting digital data corresponding to the selected portion into digital data representing a planar image for subsequent display. Various methods include the steps of storing digital data representing an image having a circular or spherical field of view, selecting a portion of the image, and converting the stored digital data corresponding to the selected portion into digital data representing a planar image for subsequent display. In various embodiments, the data converter and data conversion step may use an orthogonal set of transformation algorithms.

Martin, H. Lee↗

Applying Pattern Recognition to High-Resolution Images to Determine Cellular Signaling Status

Two frequently used tools to acquire high-resolution images of cells are scanning electron microscopy (SEM) and atomic force microscopy (AFM). The former provides a nanometer resolution view of cellular features rapidly and with high throughput, while the latter enables visualizing hydrated and living cells. In current practice, these images are viewed by eye to determine cellular status, e.g. activated versus resting. Automatic and quantitative data analysis is lacking. This work develops an algorithm of pattern recognition that works very effectively for AFM and SEM images. Using rat basophilic leukemia (RBL) cells, our approach creates a support vector machine (SVM) to automatically classify resting and activated cells. 10-fold cross-validation with cells that are known to be activated or resting gives a good estimate of the generalized classification results. The pattern recognition of AFM images achieves 100% accuracy, while SEM reaches 95.4% for our images as well as images published in prior literature. This outcome suggests that our methodology could become an important and frequently used tool for researchers utilizing AFM and SEM for structural characterization as well as determining cellular signaling status and function.

60 APPLIED LIFE SCIENCES↗

QUASI-PERIODICITIES AT YEAR-LIKE TIMESCALES IN BLAZARS

We searched for quasi-periodicities on year-like timescales in the light curves of six blazars in the optical—near-infrared bands and we made a comparison with the high energy emission. We obtained optical/NIR light curves from Rapid Eye Mounting photometry plus archival Small and Moderate Aperture Research Telescope System data and we accessed the Fermi light curves for the γ-ray data. The periodograms often show strong peaks in the optical and γ-ray bands, which in some cases may be inter-related. The significance of the revealed peaks is then discussed, taking into account that the noise is frequency dependent. Quasi-periodicities on a year-like timescale appear to occur often in blazars. No straightforward model describing these possible periodicities is yet available, but some plausible interpretations for the physical mechanisms causing periodic variabilities of these sources are examined.

79 ASTRONOMY AND ASTROPHYSICS↗

STS-67 Post Flight Presentation

This video is the post-flight presentation by the astronauts of the STS-67 Space Shuttle Mission. The astronauts were: Steve Oswald (Mission Commander), Bill Gregory (Shuttle Pilot), John Grunsfeld (Mission Specialist), Sam Durrance (Payload Specialist), Ron Parise (Payload Specialist), and Tammy Jernigan (Payload Commander). Footage includes: pre-launch suitup and launch (liftoff), the deployment of the telescope package payload (Hopkins UV telescope, Wisconsin UV polarimeter, and Astrostar Tracker) for their astronomical observations of different stellar objects, inside Shuttle shots of data collection stations, protein crystal growth experiments, medical BSO of head and eye functions in microgravity environment, storm activity over the United States and other Earth observation shots, Mid-deck Act Control Experiments, school-Shuttle direct radio communication, and descent and landing footage. This launch was a night launch and the flight was a 17 day flight (extended two days from original flight plan).

Source record↗