Search NASA⌕ Search

SEARCH · Search NASA

Results for “Demagnetization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Two-polarity magnetization in the Manson impact breccia

A preliminary paleomagnetic study of the impact breccia matrix and clasts has produced surprising results--nearly antipodal normal and reversed polarity magnetic vectors are observed in different portions of the core. Near-antipodal magnetizations within a segment of matrix and within individual samples rule out core inversion as the explanation of the dual polarity. In both the dense and the sandy matrix breccias, the magnetizations of clasts and matrix within the same core segment are identical; this negative 'conglomerate test' indicates that magnetization originated after impact. Paleomagnetic study of the Manson Impact Structure is an attempt to refine the Ar-40/Ar-39 age (65.7 +/- 1 m.y.) that suggests Manson to be a Cretaceous-Tertiary boundary impact. Refinement is possible because the boundary occurs within a reversed polarity interval (29R) of only 0.5 m.y. duration. The two breccia types in the Manson structure were both examined: one of a very dense matrix and apparently partially melted, and the breccia stratigraphically below it of granular or 'sandy' chloritic matrix. Samples were taken from the matrixes and a wide variety of clast compositions, including granite, diabase, gneiss, amphibolite, and melted granite. Currently, measurements have been made on 22 samples, using 30-35 steps of either alternating field (AF) or thermal demagnetization.

Steiner, M. B.↗

The Teton fault, Wyoming: Topographic signature, neotectonics, and mechanisms of deformation

We integrated geophysical and geological methods to evalute the structural evolution of the active Teton normal fault, Wyoming, and its role in the development of the dramatic topography of Teton Range and Jackson Hole. Comparison of variations in surface offsets with the topographic expression of the Teton range crest and drainage divide, and the overall structure of the range, suggests that the effects ofpostglacial faulting cannot be discriminated from the influence of pre-extensional structures and differential; erosion on the footwall topography. In contrast, the effects of multiple scarp-forming normal faulting earthquakes are expressed by the anomalous drainage pattern and westward tilt of the hanging wall, Jackson Hole, toward the Teton fault. Kinematic boundary element fault models suggest that the westward tilt of the valley floor is the product of 110-125 m of displacement on a 45 deg-75 deg E dipping Teton fault in the past 25,000-75,000 years. Comparisons with historic normal faulting earthquake displacements imply that this range of displacement corresponds to 10-50, M greater than 7 scarp-forming earthquakes. A total throw of 2.5 to 3.5 km across the Teton fault is suggested by inverse ray-tracing and forward gravity models. These models also suggest that Laramide age structures have been offset across the Teton fault and obscure its geophysical signature but also continue to influence the structural and topographic expression of the footwall and hanging wall blocks. Paleomagnetic analyses of the approximately 2.0 Ma Huckelberry Ridge Tuff suggest that the overall westward tilt of the Teton Range is a result ofabout 10 deg of west side down tilt across the Teton fault since tuff emplacement. This suggests that much if not all of the throw across the Teton fault has accumulated in the past 2 m.y. Complex demagnetization and rock magnetic behavior and local emplacement of the Huckleberry Ridge Tuff on preexisting topogrpahy preclude determination of the amount or variations in throw along strike of the Teton fault from the paleomagnetic data.

Byrd, John O. D.↗

Reverse Polarity Magnetized Melt Rocks from the Cretaceous/Tertiary Chicxulub Structure, Yucatan Peninsula, Mexico

We report paleomagnetic results for core samples of the breccia and andesitic rocks recovered from the Yucatan-6 Petrolcos Mexicanos exploratory well within the Chicxulub structure (about 60 km SSW from its center), northern Yucatan, Mexico. A previous study has shown that the rocks studied contain high iridium levels and shocked breccia clasts and an Ar/Ar date of 65.2 +/- 0.4 Ma. Andesitic rocks are characterized by stable single-component magnetizations with a mean inclination of -42.6 deg +/- 2.4 deg. Breccias present a complex paleomagnetic record characterized by multivectorial magnetizations with widely different initial NRM inclinations. However, after alternating field demagnetization, well defined characteristic components with upward inclinations are defined. IRM acquisition experiments, comparison of IRM and NRM coercivity spectra and the single component magnetization of the andesitic rocks indicate the occurrence of iron-rich titanomagnetites of single or pseudo-single domain states as the dominant magnetic carriers. Mean inclinations from the andesitic rocks and most of the breccia samples give a mean inclination of about -40 deg to -45 deg, indicating a reverse polarity for the characteristic magnetization that is consistent with geomagnetic chron 29R, which spans the Cretaceous/Tertiary (K/T) boundary. The inclination is also consistent with the expected value (and corresponding paleolatitude) for the site estimated from the reference polar wander curve for North America. We suggest that the characteristic magnetizations for the andesitic and breccia rocks are the result of shock heating at the time of formation of the impact structure and that the age, polarity and pateolatitude are consistent with a time at the K/T boundary.

Urrutia-Fucugauchi, J.↗

The South Pole Imaging Fabry Perot Interferometer (SPIFI)

The design and construction of the South Pole imaging Fabry-Perot interferometer (SPIFI) is reported. The SPIFI is a direct detection imaging spectrometer for use in the far infrared and submillimeter bands accessible to the 1.7 m telescope at the South Pole, and in the submillimeter bands accessible to the 15 m James Clerk Maxwell Telescope (JCMT), HI. It employs a 5 x 5 silicon bolometer array and three cryogenic Fabry Perot interferometers in series in order to achieve velocity resolutions of between 300 km/s and 30 km/s over the entire field of view with a resolution of up to 1 km/s at the center pixel. The scientific justification for the instrument is discussed, considering the spectral lines available to SPIFI. The optical path, the cryogenic Fabry-Perot, the adiabatic demagnetization refrigerator and the detector array are described. The instrument's sensitivity is presented and compared with coherent systems.

Stacey, G. J.↗

Paleomagnetism and Tectonic Interpretations of the Taos Plateau Volcanic Field, Rio Grande Rift, New Mexico

The tectonic response of the Taos Plateau volcanic field in the southern San Luis basin to the late stage extensional environment of the Rio Grande rift was investigated using paleomagnetic techniques. Sixty-two sites (533 samples) of Pliocene volcanic units were collected covering four major rock types with ages of 4.7 to 1.8 Ma. Twenty-two of these sites were from stratigraphic sections of the lower, middle and upper Servilleta Basalt collected in the Rio Grande gorge at two locations 19 km apart. Flows from the lower and middle members in the southern gorge record reversed polarities, while those in Garapata Canyon are normal with an excursion event in the middle of the sequence. The uppermost flows of the upper member at both sites display normal directions. Although these sections correlate chemically, they seem to represent different magnetic time periods during the Gilbert Reversed-Polarity Chiron. Alternating field demagnetization, aided by principal component analysis, yields 55 sites with stable directions representing both normal and reversed polarities, and five sites indicating transitional fields. Mean direction of the normal and inverted reversed sites is I=49.3 deg. and D=356.7 deg. (alpha(sub 95)=3.6 deg). Angular dispersion of the virtual geomagnetic poles is 16.3 deg, which is consistent with paleosecular variation model G, fit to data from the past 5 m.y. Comparison with the expected direction indicates no azimuthal rotation of the Taos Plateau volcanic field; inclination flattening for the southern part of the plateau is 8.3 deg +/- 5.3 deg. Previous paleomagnelic data indicate 10 deg- 15 deg counterclockwise rotation of die Espanola block to the south over the past 5 m.y. The data suggest the Taos Plateau volcanic field, showing no rotation and some flattening in the south and east, has acted as a stable buttress and has been downwarped by overriding of the southeastern end of the plateau by the Picuris Mountains, which make up the northern corner of the counterclockwise rotating Espanola block.

Brown, Laurie L.↗

The Third Flight Magnet

A self-shielded superconducting magnet was designed for the NASA Goddard Space Flight Center Adiabatic Demagnetization Refrigerator Program. This is the third magnet built from this design. The magnets utilize Cryomagnetics' patented ultra-low current technology. The magnetic system is capable of reaching a central field of two tesla at slightly under two amperes and has a total inductance of 1068 henries. This final report details the requirements of the magnet, the specifications of the resulting magnet, the test procedures and test result data for the third magnet (Serial # C-654-M), and recommended precautions for use of the magnet.

McGhee, R. Wayne↗

Thermal Performance of the XRS Helium Insert

The X-Ray Spectrometer (XRS) is an instrument on the Japanese Astro-E satellite, scheduled for launch early in the year 2000. The XRS Helium Insert comprises a superfluid helium cryostat, an Adiabatic Demagnetization Refrigerator (ADR), and the XRS calorimeters with their cold electronics. The calorimeters are capable of detecting X-rays over the energy range 0.1 to 10 keV with a resolution of 12 eV. The Helium Insert completed its performance and verification testing at Goddard in January 1999. It was shipped to Japan, where it has been integrated with the neon dewar built by Sumitomo Heavy Industries. The Helium Insert was given a challenging lifetime requirement of 2.0 years with a goal of 2.5 years. Based on the results of the thermal performance tests, the predicted on-orbit lifetime is 2.6 years with a margin of 30%. This is the result of both higher efficiency in the ADR cycle and the low temperature top-off, more than compensating for an increase in the parasitic heat load. This paper presents a summary of the key design features and the results of the thermal testing of the XRS Helium Insert.

Breon, Susan R.↗

Detector Assembly and the Ultralow-Temperature Refrigerator for XRS

The X-ray spectrometer (XRS) on the Japanese Astro-E Spacecraft is the first ultra low temperature space borne instrument. The system utilizes a 900g Ferric Ammonium Alum (FAA) Adiabatic Demagnetization Refrigerator (ADR) with a helium-3 gas gap heat switch to cool the detector assembly to 0.060K. The system operates in a "single shot" configuration allowing the system to remain at its operating temperature for about 40 hours in the lab. The on-orbit performance is expected to be about 35 hours with a 97% duty cycle. The detector assembly for XRS consists of a 32 channel microcalorimeter array bias electronics, thermometry, and an anti-coincidence detector that are attached to the cold stage of the ADR. To thermally Isolate the detector system from the superfluid helium reservoir, the detector system is suspended by Kevlar cords and electrical connection in made by L30, 17-micron diameter, tensioned NbTi leads. The detectors are read out in a source-follower arrangement using FET amplifiers operating at 130K mounted in multiply-thermally-isolated assemblies that also use Kevlar and stainless steel wiring. The design and thermal performance of this system will be discussed and compared to the theoretical limits.

Porter, F. S.↗

The XRS Low Temperature Cryogenic System: Ground Performance Test Results

The X-Ray Spectrometer (XRS) instrument is part of the Astro-E mission scheduled to launch early in 2000. Its cryogenic system is required to cool a 32-element square array of x-ray microcalorimeters to 60-65 mK over a mission lifetime of at least 2 years. This is accomplished using an adiabatic demagnetization refrigerator (ADR) contained within a two-stage superfluid helium/solid neon cooler. Goddard Space Flight Center is providing the ADR and helium dewar. The flight system was assembled in Sept. 1997 and subjected to extensive thermal performance tests. This paper presents test results at both the system and component levels. In addition, results of the low temperature topoff performed in Japan with the engineering unit neon and helium dewars are discussed.

Breon, Susan↗

Laboratory Astrophysics Using a Spare XRS Microcalorimeter

The XRS instrument on Astro-E is a fully self-contained microcalorimeter x-ray instrument capable of acquiring optimally filtering, and characterizing events for 32 independent pixels. With the launch of the Astro-E spacecraft, a full flight spare detector system has been integrated into a laboratory cryostat for use on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory. The detector system contains a microcalorimeter array with 32 instrumented pixels heat sunk to 60 mK using an adiabatic demagnetization refrio,erator. The instrument has a composite resolution of 8eV at 1 keV and 12eV at 6 keV with a minimum of 95% quantum efficiency. This will allow high spectral resolution, broadband observations of collisionally excited plasmas which are produced in the EBIT experiment. Unique to our instrument are exceptionally well characterized 1000 Angstrom thick aluminum on polyimide infrared blocking filters. The detailed transmission function including the edc,e fine structure of these filters has been measured in our laboratory using an erect field grating spectrometer. This will allow the instrument to perform the first broadband absolute flux measurements with the EBIT instrument. The instrument performance as well as the results of preliminary measurements will be discussed. Work performed under the auspices of the U.S. D.o.E. by Lawrence Livermore National Laboratory under contract W-7405-ENG-48 and was supported by the NASA High Energy Astrophysics Supporting Research and Technology Program.

Audley, M. Damian↗

Strong Magnetic Anomalies on the Lunar Near Side

The near side magnetic field is dominated by the demagnetized Imbrium basin and Oceanus Procellarum regions. However, surrounding this area are a number of strong magnetic anomalies, including Rima Sirsalis and Reiner Gamma.

Halekas, J. S.↗

A Microgravity Helium Dilution Cooler

We are developing a He-3-He-4 dilution cooler to operate in microgravity. It uses charcoal adsorption pumps and heaters for its operation; it has no moving parts. It currently operates cyclically to well below 0.1 K and we have designed a version to operate continuously. We expect that the continuous version will be able to provide the long-duration cooling that many experiments need at temperatures down to 0.040 K. More importantly, such a dilution cooler could provide the precooling that enables the use of adiabatic demagnetization techniques that can reach temperatures below 0.001 K. At temperatures below 0.002 K many fascinating microgravity experiments on superfluid He-3 become possible. Among the possibilities are: research into a superfluid He-3 gyroscope, study of the nucleation of the B-phase of superfluid He-3 when the sample is floating out of contact with walls, study of the anisotropy of the surface tension of the B-phase, and NMR experiments on tiny free-floating clusters of superfluid He-3 atoms that should model the shell structure of nuclei.

Roach, Pat R.↗

Development of a Magnetic Refrigerator Operating Between 2K and 10K

An adiabatic demagnetization refrigerator (ADR) is under development at NASA-Ames Research Center that will operate between 2 K and 10 K and will provide 50 mW of cool ng at 2 K. Gadolinium Gallium Garnet (GGG) is selected as the refrigerant for the ADR, To minimize temperature gradients in the GGG, thick slices of GGG are sandwiched together with strips of high-purity copper in between them. The copper strips are used to exchange heat between the GGG and the 2 K and the 10 K heat switches. The heat transfer across the Cu-GGG interfaces is improved by placing thin foils of' high-purity indium at the interfaces. The heat switches employed in the ADR have no moving parts. The 10 K heat switch is a helium gas-gap heat switch; while, the 2 K heat switch is a He ll-gap heat switch. A switch is on when its gap Is filled with helium and is off' when the gap is emptied. This is accomplished with an activated carbon pump (ACP). The ACP adsorbs helium when cooled and desorbs it when heated. A superconducting magnet capable of providing 9 T at 2 K is used for the ADR cycle. A prototype of this refrigerator has been built and is currently under test. A detailed design of the ADR and preliminary test results performed on the prototype ADR will be presented.

Lane, David A.↗

Efficiency Calculations For a Magnetic Refrigerator Operating Between 2K and 10K

An adiabatic demagnetization refrigerator (ADR) is being developed at NASA-Ames Research Center. The ADR will operate between 2 K and 10 K and will provide 50 mW of cooling at 2 K. The refrigerant in the ADR is Gadolinium Gallium Garnet (GGG). Absorption of heat at 2 K and heat rejection at 10 K in this fully static refrigerator is made possible by the incorporation of 2 K and 10 K heat switches. Physical layout and experimental results are presented in a parallel paper. The present paper discusses the thermal losses associated with components of the ADR as they occur in various parts of the refrigeration cycle. The results are summarized in terms of a prediction for the ADR efficiency.

Helvensteijn, Ben P. M.↗

A Compact, High-Performance Continuous Magnetic Refrigerator

We present test results of the first adiabatic demagnetization refrigerator (ADR) that can produce continuous cooling at sub-kelvin temperatures. This system uses multiple stages that operate in sequence to cascade heat from a continuous stage up to a heat sink. Continuous operation aids the usual constraints of long hold times and short recycle times that lead to the generally large mass of single-shot ADRs, and allows us to achieve much higher cooling power per unit mass. Our design goal is 10 microW of cooling at 50 mK while rejecting heat to a 6-10 K heat sink. The total cold mass is estimated to be less than 10 kg, including magnetic shielding of each stage. These parameters envelop the requirements for currently planned astronomy missions. The relatively high heat rejection capability allows it to operate with a mechanical cryocooler as part of a cryogen-free, low temperature cooling system. This has the advantages of long, mission life and reduced complexity and cost. At present, we have assembled a three-stage ADR that operates with a superfluid helium bath. Additional work is underway to develop magnetocaloric materials that can extend its heat rejection capability up to 10 K. This paper discusses the design and operation of the ADR, as well as interface requirements for cryocooler-based operation.

Shirron, Peter↗

Short-Term Aging of NeFeB Magnets for Stirling Linear Alternator Applications

NeFeB type magnets have been proposed for use in free piston Stirling engine driven, linear alternators to generate electric power during long duration space missions. These type of materials provide the highest energy product commercial magnets, thus minimizing alternator size or mass, but do not provide the high temperature stability of magnetic properties found in the SmCo type magnets. Therefore, to apply the NeFeB type magnets at elevated temperatures to multiyear space missions, their long-term aging characteristics must be determined. This report presents 200 hr aging data for six types of NeFeB magnets selected from three manufacturers. Aging was performed under vacuum at 150 C, with a steady demagnetizing field of 5 kOe applied. From the data produced by this short-term aging run, candidate magnet types were selected for a planned 12,000 hr long-term run. Depending on the manufacturer's magnet type, remanence losses observed ranged from 0 to 7%, when measured at 120 C on an established recoil line. Also, intrinsic coercivity losses up to about 4% were observed for the M-H curve at 120 C. In some cases, these coercivity losses were not recoverable by recharge of the magnet, indicating a structural change of the material.

Niedra, Janis M.↗

Rare-Earth Garnets and Perovskites for Space-Based ADR Cooling at High T and Low H

Future NASA satellite detector systems must be cooled to the 0.1 K temperature range to meet the stringent energy resolution and sensitivity requirements demanded by mid-term astronomy missions. The development of adiabatic demagnetization refrigeration (ADR) materials that can efficiently cool from the passive radiative cooling limit of approx. 30 K down to sub-Kelvin under low magnetic fields (H less than or equal to 3 T) would represent a significant improvement in space-based cooling technology. Governed by these engineering goals, our efforts have focused on quantifying the change in magnetic entropy of rare-earth garnets and perovskites. Various compositions within the gadolinium gallium iron garnet solid solution series (GGIG, Gd3Ga(5-x)Fe(x)O12, 0.00 less than or equal to X less than or equal to 5.00) and gadolinium aluminum perovskite (GAP, GdAlO3) have been synthesized via an organometallic complex approach and confirmed with powder x-ray diffraction. The magnetization of the GGIG and GAP materials has been measured as a function of composition (0.00 less than or equal to X less than or equal to 5.00), temperature (2 K less than or equal to T less than or equal to 30 K) and applied magnetic field (0 T less than or equal to H less than or equal to 3 T). The magnetic entropy change (DeltaS(sub mag)) between 0 T and 3 T was determined from the magnetization data. In the GGIG system, DeltaS(sub mag) was compositionally dependent; Fe(sup 3+) additions up to X less than or equal to 2.44 increased DeltaS(sub mag) at T > 5 K. For GAP, DeltaS(sub mag) was similar to that of GGIG, X = 0.00, both in terms of magnitude and temperature dependence at T > 10 K. However, the DeltaS(sub mag) of GAP at T < 10 K was less than the endmember GGIG composition, X = 0.00, and exhibited maximum approx. 5 K.

King, T. T.↗

A 3-D Magnetic Analysis of a Stirling Convertor Linear Alternator Under Load

The NASA Glenn Research Center (GRC), the Department of Energy (DOE), and the Stirling Technology Company (STC) are developing Stirling convertors for Stirling Radioisotope Power Systems (SRPS) to provide electrical power for future NASA deep space missions. STC is developing the 55-We Technology Demonstration Convertor (TDC) under contract to DOE. Of critical importance to the successful development of the Stirling convertor for space power applications is the development of a lightweight and highly efficient linear alternator. This paper presents a 3-dimensional finite element method (FEM) approach for evaluating Stirling convertor linear alternators. The model extends a magnetostatic analysis previously reported at the 35th Intersociety Energy Conversion Engineering Conference (IECEC) to include the effects of the load current. STC's 55-We linear alternator design was selected to validate the model. Spatial plots of magnetic field strength (H) are presented in the region of the exciting permanent magnets. The margin for permanent magnet demagnetization is calculated at the expected magnet operating temperature for the near earth environment and for various average magnet temperatures. These thermal conditions were selected to represent a worst-case condition for the planned deep space missions. This paper presents plots that identify regions of high H where the potential to alter the magnetic moment of the magnets exists.

Geng, Steven M.↗