Search NASA⌕ Search

SEARCH · Search NASA

Results for “Demand management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Distribution System Congestion Management - A Survey of Reliable Integration for Aggregated Resources and Microgrids

Rising penetration of consumer-owned Distribution Grid Resources (DGRs), increasingly managed by third party aggregators and enrolled in grid services and wholesale market programs, can create localized congestion in distribution networks. Managing these constraints is challenging due to a persistent coordination and information gap: utilities are accountable for reliability and have network topology and state visibility, while aggregators control the DGR capability needed to relieve congestion. This survey synthesizes congestion management solutions for distribution systems with high DGR penetration, covering both market-based mechanisms (distribution level markets, locational pricing, flexibility auctions) and non-market-based solutions (network reconfiguration, direct DGR control, demand response, curtailment, etc.). The literature is organized across three decision horizons: long term planning, operational planning, and real-time operation. Special attention is devoted to emerging distribution system operator architectures and coordination frameworks spanning transmission system operators, aggregators, and microgrids. Drawing on recent case studies and implementations, we distill best practices, identify key technical and economic barriers, and outline research directions. The evidence points to a shift toward integrated congestion management that combines market signals with technical controls, enabled by improved monitoring, forecasting, and closed loop control capabilities.

Active Distribution Networks (ADN)↗

Winners are not keepers: Characterizing household engagement, gains, and energy patterns in demand response using machine learning in the United States

Demand-response programs can help utilities manage rapidly evolving electric grids, but these programs are subject to the complexities of human behavior. This paper explores a novel method for uncovering heterogeneity in households. In this work, we use a machine-learning method known as a Conditional Inference Tree (c-tree) algorithm to categorize households based on their energy behavior characteristics collected via smart meters, and explore how this translates through into heterogeneity in their real-world response to a DR program. Using data from randomized controlled trial, we generate estimates of the changes in energy use caused by the program within each household group. Our results show that the c-tree approach differentiates households by their energy-use characteristics in a way that increases the spread in enrollment rates and critical peak reduction among household groups, compared with the spreads achieved via several conventional segmentation methods. Thus, the c-tree analysis enables the most tailored targeting of major potential energy savers and could provide the greatest increase in cost-effectiveness of household recruitment into DR programs. Our results also offer fresh insights into the relationships between household energy behavior characteristics – such as peak energy use and “structural winningness” (the ability to save money under a DR program without changing energy-use behaviors) – and household decisions about enrolling in DR programs and reducing energy use. Our research also demonstrates the potential of smart meter data, combined with machine learning and econometric methods, to provide significant value to utilities, program implementers, researchers, and other stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achieving a Net-Zero Future: The Role of Nuclear Energy

Governments and private industry around the world have established aggressive goals to achieve net-zero emissions for the power, industrial, and transportation sectors by 2050. These aggressive goals demand immediate action if we are to be successful, and they require us to think more holistically about our clean energy options. Programs within the U.S. Department of Energy (DOE) are addressing these holistic solutions. Traditionally, electricity generation and management are considered independently from meeting energy demands for industry and transportation. As we seek to eliminate emissions across all energy use sectors we need to reassess how energy demands are met. When we consider overall energy use, only one-third is in the form of electricity. Additional energy demands are in the form of heat or steam for industrial processes, in addition to direct fuel use for transportation. These sectors are much harder to abate, and electrification may not be the best option. Reducing environmental emissions at an affordable cost, while maintaining grid reliability and resilience, will require us to leverage all of the clean energy resources available. The DOE Office of Nuclear Energy (DOE-NE) program on Integrated Energy Systems (IES) is led by researchers at Idaho National Laboratory (INL), and work is conducted in partnership with an array of other DOE laboratories, industry, and academia. The primary focus of IES research is to assess the technical and economic potential of nuclear-driven IES to enhance the flexibility and utilization of nuclear reactors working alongside renewable generators to meet an array of energy demands—thereby maximizing the utilization of clean energy resources across all energy sectors. Various energy applications and product streams beyond electricity are being evaluated, ranging from generation of potable water to production of hydrogen, fertilizers, synthetic fuels, and various chemicals. The DOE-NE program additionally partners with the Hydrogen and Fuel Cell Technologies Office under the DOE Office of Energy Efficiency and Renewable Energy to jointly fund the development of analysis tools, technologies, and nuclear-integrated hydrogen demonstration projects. This presentation will highlight the wide array of R&D being conducted across multiple DOE-funded programs to develop and deploy nuclear-based IES that will be key to achieving our net-zero goals. By working with key collaborators in the nuclear industry, analytical studies are now becoming a reality in demonstration projects.

08 HYDROGEN↗

Modeling the Water Systems of the Western US to Support Climate‐Resilient Electricity System Planning

Abstract Electricity and water systems in the Western US (WUS) are closely connected, with hydropower comprising 20% of total annual WUS generation, and electricity related to water comprising about 7% of total WUS electricity use. Because of these interdependencies, the threat of climate change to WUS resources will likely have compounding electricity impacts on the Western Interconnect grid. This study describes a WUS‐wide water system model with a particular emphasis on estimating climate impacts on hydropower generation and water‐related electricity use, which can be linked with a grid expansion model to support climate‐resilient electricity planning. The water system model combines climatically‐driven physical hydrology and management of both water supply and demand allocation, and is applied to an ensemble of 15 climate scenarios out to 2050. Model results show decreasing streamflow in key basins of the WUS under most scenarios. Annual water‐related electricity use increases up to 4%, and by up to 6% during the summer months, driven by growing agricultural demands met increasingly through a shift toward energy‐intensive groundwater to replace declining surface water. Total annual hydropower generation changes by +5% to −20% by mid‐century but declines in most scenarios, with decreases in summer generation by up to nearly −30%. Water‐related electricity use increases tend to coincide with hydropower generation declines, annually and seasonally, demonstrating the importance of concurrently evaluating the climate signal on both water‐for‐energy and energy‐for‐water to inform planning for grid reliability and decarbonization goals.

13 HYDRO ENERGY↗

Elucidating the impact of fiber source on polypropylene/hemp composite performance for the automotive industry

Given their high strength-to-weight ratio, there is an ever-increasing volume of plastics being used in the automotive industry as plastics aid in the charge to lightweight vehicles for improved fuel efficiency. However, these plastics are often landfilled at their end-of-life, which has given rise to the demand for sustainable materials and waste management alternatives compared to purely synthetic systems. Natural fiber composites have been explored as a viable material option to reduce the environmental impact of plastic use in automobiles while simultaneously ensuring the part performance is not sacrificed. Herein, we explored the use of hemp/polypropylene (PP) composites in which US-sourced hemp is compared to internationally sourced and industrially available hemp. There appears to be a minimal impact on the composite properties regardless of fiber sourcing, and the addition of a natural filler to the PP matrix results in up to a 367% increase in Young's modulus, 126% increase in heat deflection temperature, and comparable water uptake performance. It should be noted that the natural filler addition does increase density by up to 13% due to the higher density of natural fibers compared to the low-density PP matrix. A modified rule of mixtures calculation revealed that the composite materials produced in this study demonstrated good agreement with analytical modeling. Finally, a screening analysis was performed exploring the transportation of hemp fibers, and the results build a strong case for regionalized manufacturing of automotive parts.

Hubbard, Amber M. [Oak Ridge National Laboratory (↗

Building Energy Systems as Behind-the-Meter Resources for Grid Services: Intelligent load control and transactive control and coordination

To mitigate the impacts of climate change, significant reductions in emissions from all sectors of the economy are needed. The electricity generation sector has embarked on an ambitious plan to include renewable generation as part of its decarbonization efforts, and many cities and states are mandating all-electric buildings. While renewable resources will reduce emissions, they are not dispatchable, they vary temporally, and their generation is uncertain. Under these conditions, traditional approaches to managing grid reliability, where supply follows demand, will not be efficient and may not be cost-effective. Further, there is a more efficient alternative for balancing the supply–demand imbalance and for absorbing variability and uncertainty of renewable energy using distributed energy resources (DERs) as opposed to reserve generation. Because buildings consume more than 75% of total U.S. annual electricity consumption, behind-the-meter (BTM) DERs have a load flexibility of 77 GW of power and 90 GWh of virtual energy storage capacity nationwide (Kalsi, 2017). Therefore, some portion of the supply–demand imbalance can be met by these DERs at a lower cost compared to business-as-usual solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technology in Focus: Power-to-X

Power-to-X is the process that converts electricity into energy carriers that can be used in industries and applications not connected to the electricity grid. By creating a product with direct process connected generation, contracted generation, or grid-delivered electricity that is in excess of current demand, production of electricity can be managed to time arbitrage energy and mitigate generation curtailment or inefficient operational reductions. In addition, creating a product potentially develops a secondary revenue stream that aids economics of the facility. This document is a high-level factsheet that provides an overview of what Power-to-X is and what it means.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Waste-to-Energy Pipeline through Consolidated Fermentation–Microbial Fuel Cell (MFC) System

The rise in population, urbanization, and industrial developments have led to a substantial increase in waste generation and energy demand, posing significant challenges for waste management as well as energy conservation and production. Bioenergy conversions have been merged as advanced, sustainable, and integrated solutions for these issues, encompassing energy generation and waste upcycling of different types of organic waste. Municipal solid waste (MSW) and agricultural residues (AR) are two main resources for bioenergy conversions. Bioenergy production involves feedstock deconstruction and the conversion of platform chemicals to energy products. This review provides a detailed overview of waste sources, biofuel, and bioelectricity production from fermentation and microbial fuel cell (MFC) technology, and their economic and environmental perspectives. Fermentation plays a critical role in liquid biofuel production, while MFCs demonstrate promising potential for simultaneous production of electricity and hydrogen. Fermentation and MFCs hold a significant potential to be integrated into a single pipeline, enabling the conversion of organic matter, including a variety of waste material and effluent, into diverse forms of bioenergy via microbial cultures under mild conditions. Furthermore, MFCs are deemed a promising technology for pollutant remediation, reducing COD levels while producing bioenergy. Importantly, the consolidated fermentation–MFC system is projected to produce approximately 7.17 trillion L of bioethanol and 6.12 × 10 4 MW/m 2 of bioelectricity from MSW and AR annually, contributing over USD 465 billion to the global energy market. Such an integrated system has the potential to initiate a circular economy, foster waste reduction, and improve waste management practices. This advancement could play a crucial role in promoting sustainability across the environmental and energy sectors.

09 BIOMASS FUELS↗

Characterization of Connected Lighting System Potential for Grid Services Under Real-Time Pricing

Increasingly over the last decade, the management of end-use electricity demand has been examined as a potential source of services for the electric power grid beyond contracts with large commercial and industrial customers. Lighting represents about 17\% of U.S. commercial building annual electricity consumption; however, its potential rapid speed of response may position it to uniquely contribute to services that improve the reliability and resilience of the grid. Connected lighting systems (CLS), which build upon solid-state lamp technology, can change state by adjusting power demand more quickly than most other building electricity end uses and could be used as a platform to monitor lighting electricity use and space conditions. But the potential of CLS to provide grid services has not been extensively studied. In this paper, we describe initial research to evaluate the potential of CLS for grid services. We develop a model for CLS using a set of parameters to represent operation behaviors and constraints: maximal power, minimal power, nominal power, ramp rate, and time delay. Parameter values are generated for representative building types. CLS demand curves are constructed, indirectly capturing building occupant preferences for lighting as functions of electricity price. The CLS model and the demand curves are incorporated into a Transactive Control and Coordination (TCC) Platform to simulate CLS providing grid services. Previous research has shown TCC to be a powerful tool to enable end uses to provide grid services through a hybrid economic-control approach. Initial quantitative results will be provided for CLS grid services potential.

Wang, Peng↗

Quantifying the Value of Grid-Interactive Efficient Buildings through Field Study: Preprint

Quantifying the annual energy impacts of efficient technologies in commercial buildings has been well established by the building science field. As we move toward enabling grid-interactive efficient buildings (GEB) targeting flexible building operation and carbon reduction, quantification methods to evaluate time-sensitive peak load and emissions impact are much less defined. A number of national laboratories are working to field validate four different GEB software solutions that provide the capability to control multiple building end-use systems in multiple load flexibility modes (i.e., energy efficiency, load shed, load shift, and possible load modulation at the second to sub-second level). To guide the laboratory leads in effective measurement and verification (M&V) practices, two of the laboratories collaborated to define metrics to quantify the impacts of flexible load control on building demand, utility costs, carbon emissions, facility management, and occupant comfort. This paper summarizes the proposed metrics to quantify peak load and emission impacts in the field, decision parameters, approaches to accurately conduct M&V, lessons learned, and outstanding needs and next steps.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Quantifying the Value of Grid-Interactive Efficient Buildings through Field Study

Quantifying the annual energy impacts of efficient technologies in commercial buildings has been well established by the building science field. As we move toward enabling grid-interactive efficient buildings (GEB) targeting flexible building operation and carbon reduction, quantification methods to evaluate time-sensitive peak load and emissions impact are much less defined. A number of national laboratories are working to field validate four different GEB software solutions that provide the capability to control multiple building end-use systems in multiple load flexibility modes (i.e., energy efficiency, load shed, load shift, and possible load modulation at the second to sub-second level). To guide the laboratory leads in effective measurement and verification (M&V) practices, two of the laboratories collaborated to define metrics to quantify the impacts of flexible load control on building demand, utility costs, carbon emissions, facility management, and occupant comfort. This paper summarizes the proposed metrics to quantify peak load and emission impacts in the field, decision parameters, approaches to accurately conduct M&V, lessons learned, and outstanding needs and next steps.

Langner, Rois↗

Individual Data Sparsity in Smart Thermostat Big Data: Impacts on Modeling Thermostat Use Behavior Dynamics

This study explores the impacts of the sparsity of individual thermostat interaction data on modeling thermostat use behavior dynamics using a dataset of over 100,000 smart thermostats. In developing a data-driven model of Thermal Frustration Theory (TFT), we investigate the challenges and trade-offs in clustering occupant data to enhance predictive accuracy. Our findings reveal that a single, aggregated model fails to capture the diversity of occupant behaviors, resulting in extremely poor prediction performance. Conversely, excessive clustering exacerbates data sparsity, undermining model reliability. By identifying an optimal clustering strategy, we achieve a balance that significantly improves the prediction of manual setpoint changes during demand response (DR) events, enhancing energy management and occupant comfort

Fannon, David↗

Performance Assessment of a Heat Pump Integrated with Thermal Energy Storage in Cooling & Heating Modes

Thermal Energy Storage (TES) systems have demonstrated significant potential to manage the fluctuating nature of energy demand and shifting peak loads. This technology has made significant recent advances, including new research on the integration of TES with residential and commercial Heating, Ventilation, and Air-Conditioning (HVAC) systems. In this paper, we present the use of a novel laboratory assessment framework for a prototype heat pump system integrated with latent heat phase change material-based TES. The assessment framework consists of 22 total test points (11 heating, 11 cooling) using psychrometric conditions from AHRI Standard 210/240 and includes transient conditions to evaluate TES charging and discharging modes. In addition, both continuous mode and cyclic mode were evaluated for charging and discharging to explore the benefits to TES heat transfer from repeated transient operation. The ambient conditions evaluated include heating mode charging at cold-climate heat pump conditions when winter-peaking utilities may most require demand reduction (H4Full conditions, 5°F/-15°C) and cooling mode charging at high ambient temperature that may occur during times of day when excess solar power generation results in low-cost electricity (105°F/40.6°C). The work demonstrates the demand reduction capabilities of integrating TES with HVAC, including up to 44% in cooling mode and 60% in heating mode compared to conventional HVAC equipment without TES.

25 ENERGY STORAGE↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

Overcoming persistent challenges in putting environmental flow policy into practice: a systematic review and bibliometric analysis

The implementation of environmental flows (e-flows) aims to reduce the negative impacts of hydrological alteration on freshwater ecosystems. Despite the growing attention to the importance of e-flows since the 1970s, actual implementation has lagged. Therefore, we explore the limitations in e-flows implementation, their systemic reasons, and solutions. We conducted a systematic review and a bibliometric analysis to identify peer-reviewed articles published on the topic of e-flows implementation research in the last two decades, resulting in 68 research and review papers. Co-occurrence of terms, and geographic and temporal trends were analyzed to identify the gaps in environmental water management and propose recommendations to address limitations on e-flows implementation. We identify the underlying causes and potential solutions to such challenges in environmental water management. The limitations to e-flow implementation identified were categorized into 21 classes. The most recognized limitation was the competing priorities of human uses of water (n = 29). Many secondary limitations, generally co-occurring in co-causation, were identified as limiting factors, especially for implementing more nuanced and sophisticated e-flows. The lack of adequate hydrological data (n = 24) and ecological data (n = 28) were among the most mentioned, and ultimately lead to difficulties in starting or continuing monitoring/adaptive management (n = 28) efforts. The lack of resource/capacity (n = 21), experimentation (n = 19), regulatory enforcement (n = 17), and differing authorities involved (n = 18) were also recurrent problems, driven by the deficiencies in the relative importance given to e-flows when facing other human priorities. In order to provide a clearer path for successful e-flow implementation, system mapping can be used as a starting point and general-purpose resource for understanding the sociohydrological problems, interactions, and inherited complexity of river systems. Secondly, we recommend a system analysis approach to address competing demands, especially with the use of coupled water-energy modeling tools to support decision-making when hydropower generation is involved. Such approaches can better assess the complex interactions among the hydrologic, ecological, socioeconomic, and engineering dimensions of water resource systems and their effective management. Lastly, given the complexities in environmental water allocation, implementation requires both scientific rigor and proven utility. Consequently, and where possible, we recommend a move from simplistic flow allocations to a more holistic approach informed by hydroecological principles. To ease conflicts between competing water demands, water managers can realize more 'pop per drop' by supporting key components of a flow regime that include functional attributes and processes that enhance biogeochemical cycling, structural habitat formation, and ecosystem maintenance.

54 ENVIRONMENTAL SCIENCES↗

Impacts of Forest Management-Induced Productivity Changes on Future Land Use and Land Cover Change

Anthropogenic land use and land cover change (LULCC) is projected to continue in the future. However, the influence of forest management on forest productivity change and subsequent LULCC projections remains under-investigated. This study explored the impacts of forest management-induced change in forest productivity on LULCC throughout the 21st century. Specifically, we developed a framework to softly couple the Global Change Analysis Model and Global Timber Model to consider forest management-induced forest productivity change and projected future LULCC across the five Shared Socioeconomic Pathways (SSPs). We found future increases in forest management intensity overall drive the increase of forest productivity. The forest management-induced forest productivity change shows diverse responses across all SSPs, with a global increase from 2015 to 2100 ranging from 3.9% (SSP3) to 8.8% (SSP1). This further leads to an overall decrease in the total area with a change of land use types, with the largest decrease under SSP1 (-7.5%) and the smallest decrease under SSP3 (-0.7%) in 2100. Among land use types, considering forest management-induced change significantly reduces the expansion of managed forest and also reduces the loss of natural land in 2100 across SSPs. This suggests that ignoring forest management-induced forest productivity change underestimates the efficiency of wood production, overestimates the managed forest expansion required to meet the future demand, and consequently, potentially introduces uncertainties into relevant analyses, for example, carbon cycle and biodiversity. Thus, we advocate to better account for the impacts of forest management in future LULCC projections.

54 ENVIRONMENTAL SCIENCES↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources: Preprint

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS—based on real-time optimal power flow—controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

61 RADIATION PROTECTION AND DOSIMETRY↗