Chloride-based Wireline Tool for Measuring Fracture Inflow in Enhanced Geothermal Systems (EGS) Wells: Field Deployment Updates
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
NREL develops and de-risks a portfolio of technologies for converting biomass and waste resources into liquid transportation fuels, including jet fuel.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
NLR develops and de-risks a portfolio of technologies for converting biomass and waste resources into liquid transportation fuels, including jet fuel.
This document outlines how to install Malcolm (https://inl.gov/national-security/ics-malcolm/) on an Amazon AWS EC2 instance. It's intended for a blog post to be released on the Amazon AWS blog.
NIU 2026 Senior Design Showcase
Informational presentation on the use of AI for autonomous design at INL's Scientific Computing and AI division (C500). Presented to visitors on 05/15/2025.
No abstract - Powerpoint for presentation at meeting
Powerpoint presentation for the 2025 NPIC-HMIT conference on barriers for adoption of DI&C systems in nuclear reactors.
Slides prepared for the research seminar at universities of the research progress funded by the Advanced Reactor Technologies (ART) - Gas Cooled Reactors (GCR) program.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Inverter-based resources (IBRs) such as photovoltaics (PVs), wind turbines, and battery energy storage systems (BESSs) are widely deployed in low-carbon power systems. However, these resources typically do not provide the inertia needed for grid stability, resulting in a low-inertia power system. IBRs and lack of inertia have been known to cause anomalies such as waveform distortions and wideband oscillations in power systems due to the limited inertia level, leading to increased generation trips and load shedding. Here, to achieve effective anomaly identification, this paper proposes a synchro-waveform-based algorithm utilizing real-time synchronized voltage waveform measurements from waveform measurement units (WMUs). In the proposed method, different physical characteristics, as well as statistical features, are extracted from synchronized voltage waveform measurements to filter anomalies. Then, the anomaly identification approach based on the random forest is developed and deployed into the FNET/GridEye system considering trade-offs among accuracy, computational burden, and deployment cost. Moreover, four WMUs are specially designed and deployed on Kauai Island to receive instantaneous synchronized voltage waveform measurements. To verify the performance of the proposed algorithm, different experiments are carried out with collected field test data. The result demonstrates that the performance of the proposed synchro-waveform-based anomaly categorization algorithm can accurately identify anomalies 95.35% of the time, which has comparable performance among benchmarking algorithms.
Current models of inner lunar geology have largely been inferred from the seismic experiments and observations performed during the Apollo missions that comprised a relatively small number of seismic instruments. Refining constraints on fundamental lunar relationships such as crust-mantle and mantle-core boundaries in the future will require seismic arrays spanning larger epicentral distances. A promising technology for installing dense seismic arrays with minimal human effort is distributed acoustic sensing (DAS), an approach that allows a single length of fiber optic cable to act as hundreds or thousands of sensors when coupled with a DAS interrogator. While terrestrial uses of DAS technology for seismic monitoring rely on burying the cable to maximize fidelity of seismic signal transmission to the fiber, digging meters of trench to bury optical fiber on lunar or planetary surfaces is logistically infeasible. To evaluate DAS signal attenuation due to surface deployment of cable in lunar regolith, we completed earthquake detection analyses that evaluated the sensitivity of an optic-fiber DAS system to seismic signals at different burial depths. We deployed a single-mode fiber in a 10-m open-bottom wooden box filled with a lunar regolith simulant (LRS) with fiber buried at different depths within the LRS and recorded signals for four regional and local earthquakes. The results were used to identify and evaluate signal attenuation in surface-deployed fiber compared to buried fiber in the LRS. Burial depth responses to active-source signals were also evaluated similar to previous studies characterizing DAS sensitivity of surface-deployed fiber. Atmospheric noise was minimal as the cable was deployed in an indoor environment; however, where observed, atmospheric and anthropogenic noise was filtered out using the same bandpass filtering used to identify earthquake events. We found that signal attenuation of the surface-deployed fiber compared to buried fiber was relatively high in active-source experiments but was not consistently observed in earthquake signals. That burial depth is not highly correlated to attenuation of the observed earthquake signals indicates that in a noise-limited environment, placing DAS-interrogated fiber directly at the regolith surface may be a promising deployment strategy to consider for sensing remote seismic signals during lunar exploration.
The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.