Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diagnostic Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Soft X-ray astronomy using grazing incidence optics

The instrumental background of X-ray astronomy with an emphasis on high resolution imagery is outlined. Optical and system performance, in terms of resolution, are compared and methods for improving the latter in finite length instruments described. The method of analysis of broadband images to obtain diagnostic information is described and is applied to the analysis of coronal structures.

Davis, John M.↗

Seismic Holography of Solar Activity

The basic goal of the project was to extend holographic seismic imaging techniques developed under a previous NASA contract, and to incorporate phase diagnostics. Phase-sensitive imaging gives us a powerful probe of local thermal and Doppler perturbations in active region subphotospheres, allowing us to map thermal structure and flows associated with "acoustic moats" and "acoustic glories". These remarkable features were discovered during our work, by applying simple acoustic power holography to active regions. Included in the original project statement was an effort to obtain the first seismic images of active regions on the Sun's far surface.

Lindsey, Charles↗

Proposed Space Flight Experiment Hardware

The primary thrust for this plan is to develop design tools and fundamental understanding that are timely and consistent with the goal of the various exploration initiatives. The plan will utilize ISS facilities, such as the Fluids Integrated Rack (FIR) and the Microgravity Science Glovebox (MSG). A preliminary flow schematic of Two-Phase Flow Facility (T(phi)FFy) which would utilize FIR is shown in Figure 3. MSG can be utilized to use the Boiling eXperiment Facility (BXF) and Contact Line Dynamics Experiment (CLiDE) Facility. The T(phi)FFy system would have multiple test sections whereby different configurations of heat exchangers could be used to study boiling and condensation phenomena. The test sections would be instrumented for pressure drop, void fraction, heat fluxes, temperatures, high-speed imaging and other diagnostics. Besides a high-speed data acquisition system with a large data storage capability, telemetry could be used to update control and test parameters and download limited amounts of data. In addition, there would be multiple accumulators that could be used to investigate system stability and fluid management issues. The system could accommodate adiabatic tests through either the space station nitrogen supply or have an experiment-specific compressor to pressurize a sufficient amount of air or other non-condensable gas for reuse as the supply bottle is depleted.

Source record↗

Gravity Effects in Condensing and Evaporating Films

A general overview of gravity effects in condensing and evaporating films is presented. The topics include: 1) Research Overview; 2) NASA Recognizes Critical Need for Condensation & Evaporation Research to Enable Human Exploration of Space; 3) Condensation and Evaporation Research in Reduced Gravity is Enabling for AHST Technology Needs; 4) Differing Role of Surface Tension on Condensing/Evaporating Film Stability; 5) Fluid Mechanisms in Condensing and Evaporating Films in Reduced Gravity; 6) Research Plan; 7) Experimental Configurations for Condensing Films; 8) Laboratory Condensation Test Cell; 9) Aircraft Experiment; 10) Condensation Study Current Test Conditions; 11) Diagnostics; 12) Shadowgraph Images of Condensing n- pentane Film in Unstable (-1g) Configuration; 13) Condensing n-Pentane Film in Normal Gravity (-1g) at Constant Pressure; 14) Condensing n-Pentane Film in Normal Gravity (-1g) with Cyclic Pressure; 15) Non-condensing Pumped Film in Normal Gravity (-1g); 16) Heat Transfer Coefficient in Developing, Unstable Condensing Film in Normal Gravity; 17) Heat Transfer for Unsteady Condensing Film (-1g); 18) Ultrasound Measurement of Film Thickness N-pentane Film, Stable (+1g) Configuration; and 19) Ultrasound Measurement of Film Thickness N-pentane Film, Unstable (-1g) Configuration.

Hermanson, J. C.↗

Smart Ultrasound Remote Guidance Experiment (SURGE)- Concept of Operations Evaluation for Using Remote Guidance Ultrasound for Planetary Space Flight

Introduction Use of remote guidance (RG) techniques aboard the International Space Station (ISS) has enabled astronauts to collect diagnostic-level ultrasound images. Exploration class missions will require this cohort of (typically) non-formally trained sonographers to operate with greater autonomy given the longer communication delays (2 seconds for ISS vs. >6 seconds for missions beyond the Moon) and communication blackouts. To determine the feasibility and training requirements for autonomous ultrasound image collection by non-expert ultrasound operators, ultrasound images were collected from a similar cohort using three different image collection protocols: RG only, RG with a computer-based learning tool (LT), and autonomous image collection with LT. The groups were assessed for both image quality and time to collect the images. Methods Subjects were randomized into three groups: RG only, RG with LT, and autonomous with LT. Each subject received 10 minutes of standardized training before the experiment. The subjects were tasked with making the following ultrasound assessments: 1) bone fracture and 2) focused assessment with sonography in trauma (FAST) to assess a patient s abdomen. Human factors-related questionnaire data were collected immediately after the assessments. Results The autonomous group did not out-perform the two groups that received RG. The mean time for the autonomous group to collect images was less than the RG groups, however the mean image quality for the autonomous group was less compared to both RG groups. Discussion Remote guidance continues to produce higher quality ultrasound images than autonomous ultrasound operation. This is likely due to near-instant feedback on image quality from the remote guider. Expansion in communication time delays, however, diminishes the capability to provide this feedback, thus requiring more autonomous ultrasound operation. The LT has the potential to be an excellent training and coaching component for autonomous ultrasound image collection during exploration missions.

Hurst, Victor, IV↗

Subscale Test Program for the Orion Conical Ribbon Drogue Parachute

A subscale wind tunnel test program for Orion's conical ribbon drogue parachute is under development. The desired goals of the program are to quantify aerodynamic performance of the parachute in the wake of the entry vehicle, including understanding of the coupling of the parachute and command module dynamics, and an improved understanding of the load distribution within the textile elements of the parachute. The test program is ten percent of full scale conducted in a 3x2.1 m (10x7 ft) closed loop subsonic wind tunnel. The subscale test program is uniquely suited to probing the aerodynamic and structural environment in both a quantitative and qualitative manner. Non-intrusive diagnostics, including Particle Image Velocimetry for wake velocity surveys, high speed pressure transducers for canopy pressure distribution, and a high speed photogrammetric reconstruction, will be used to quantify the parachute's performance.

parachute↗

Instrument design for an inertial confinement fusion ion temperature imager

A mix of contaminant mass is a known, performance-limiting factor for laser-driven inertial confinement fusion (ICF). It has also recently been shown that the contaminant mass is not necessarily in thermal equilibrium with the deuterium–tritium plasma. Contaminant mass temperature is one of the dominant uncertainties in contaminant mass estimates. The MixIT diagnostic is a new and potentially transformative diagnostic, capable of spatially resolving ion temperature. The approach combines principles of neutron time-of-flight and neutron imaging diagnostics. The information from the MixIT diagnostic can be used to optimize ICF target and laser drive designs as well as provide key constraints on ICF radiation-hydrodynamic simulations that are critical to contaminant mass estimates. This work details the design and optimization of the major components of the MixIT diagnostic: the neutron aperture, the neutron detector (scintillator), and the recording system.

47 OTHER INSTRUMENTATION↗

Imaging Station Multi-Foil Target

The Axis II Downstream Transport (DST) of the Dual Axis Radiographic Hydrodynamic Testing (DARHT) Facility is the final subassembly of the particle accelerator whose primary objective is to focus the 4-pulse beam as it enters the Target Region. Before the beam reaches the Target Region, it passes through two imaging stations located in the DST. At Imaging Station E (ISE) and Imaging Station C (ISC), diagnostics are conducted and experimenters study beam physics using specialized targets. Different targets are used depending on the objective of the study. The desire to conduct specific experiments has driven a need for a multi-foil target. This new design has been engineered to allow for new capabilities, and diagnostics to be studied at ISC. To accommodate new parameters, three different configurations have been conceived. Although each of the three designs differ from each other, their function and purpose remain consistent. Each target is engineered to secure a variable amount of target foils at variable spacing while Imaging Station experiments are conducted. Beam diagnostics and data from the targets are analyzed through various sized viewports on the imaging stations. The objective of this technical note is to document the purpose and functionality of the targets. Design considerations, assembly instructions, and maintenance recommendations are also discussed. Additionally, each target and its respective advantages and disadvantages are covered in detail.

43 PARTICLE ACCELERATORS↗

Rock-type discrimination from ratioed infrared scanner images of Pisgah Crater, California.

The radiances in two thermal infrared channels of an airborne scanner system were ratioed to produce images that recorded compositionally diagnostic emittance variations for several silicate rock types near Pisgah Crater, California. The images demonstrate that the ratio method is capable of enhancing emittance variations in the presence of temperature extremes that differ by no more than 25 C, with no temperature corrections.

Vincent, R. K.↗

A time-resolved imaging system for the diagnosis of x-ray self-emission in high energy density physics experiments

A diagnostic capable of recording spatially and temporally resolved x-ray self-emission data was developed to characterize experiments on the MAGPIE pulsed-power generator. The diagnostic used two separate imaging systems: a pinhole imaging system with two-dimensional spatial resolution and a slit imaging system with one-dimensional spatial resolution. The two-dimensional imaging system imaged light onto the image plate. The one-dimensional imaging system imaged light onto the same piece of image plate and a linear array of silicon photodiodes. This design allowed the cross-comparison of different images, allowing a picture of the spatial and temporal distribution of x-ray self-emission to be established. The design was tested in a series of pulsed-power-driven magnetic-reconnection experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NorthStar Facility Target Fab and Flow Testing - FY 21

The facility target fabrication and flow testing activity will consist of flow tests using the blower system at LANL to test the disk holder and target, both redesigned by the NorthStar prime contractor. The housing and transition system delivering helium cooling to the disc holder and target will be fabricated and tested at LANL facilities. The tests will include pressure drop versus flow measurements through the target and housing, optical flow diagnostics and fiber optic imaging of the disc stack. The pressure drop measurements will be compared to CFD simulations to verify the latter, the optical flow diagnostics will be used to determine whether modifications made to the housing and target holder allow sufficient flow through the bottom of the housing to adequately cool it and the fiber optics will be used to image the discs during operation as a proof of concept of the diagnostic, to be used at NorthStar facilities during preproduction testing. The work is a Partial Fulfillment of the Deliverable Requirement for NorthStar Facility Target Fab and Flow Testing and Production Target Testing Support by LANL

42 ENGINEERING↗

Blade Designs For Improved Multi-Phase Performance In sCO 2 Compressors; Part II - Optical Diagnostics In sCO 2 And Experimental Evaluation With Particle Image Velocimetry

This paper presents the second part of a study in which the leading-edge and suction surface of a compressor blade was modified to delay onset of phase change for sCO 2 compressors operating near the critical point. Using a first-of-its-kind apparatus for the measurement of sCO 2 flow fields, Particle Image Velocimetry (PIV) is used for local flow field measurements of two compressor blade geometries: the modified “biased-wedge,” and a conventional constant thickness blade. Utilizing the developed hardware, the feasibility of a simple, laser-based diagnostic for qualitatively measuring liquid phase regions, is also presented. The design of the optical diagnostics rig, a discussion of numerous challenges, and necessary considerations involved in performing optical-based measurements like PIV, in sCO 2 , are discussed. Velocity field measurements for the modified compressor profile show a much lower suction peak compared to a conventional blade. Furthermore, these results validate numerical results at the tested conditions, where the suction side profile of the biased wedge works to minimize the local pressure gradient.

14 SOLAR ENERGY↗

X-Ray Imaging And Assessment Of Non-Perturbing Magnetic Diagnostics For Intermediate-Density Fusion Experiments

This research adds to the understanding of when, why, where, and how fusion-grade plasmas generate X-rays. Normal fusion reactions create different spectra of X-rays from unwanted spurious situations so examination of the X-ray spectra provides information on whether a fusion device is operating properly or not. The characteristic time scale of the X-rays ranges from a few nanoseconds to a microseconds so a movie camera having a very high framing rate is required. The energy of the X-rays is not known and so the camera should provide information on what this energy is. The mechanism by which the X-rays are generated varies depend on whether the X-rays are from normal operation or from unwanted spurious effects. This project developed prototypes of a high-speed X-ray movie camera using two different technologies. These were tested on pulsed plasma experiments at Caltech. Despite having modest plasma parameters these experiments generated transient X-ray bursts suitable for developing and testing these cameras. One of the cameras was used on the MIFTI fusion-related experiment at UCSD and provided information on the energy, location, and timing of X-rays produced there. The camera could measure X-rays having energies from about 5 kilovolts to about 30 kilovolts with 40 nanosecond time resolution and space resolution of a few mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a high-resolution Rayleigh-Taylor experiment with the Crystal Backlighter Imager on the National Ignition Facility

The Rayleigh-Taylor (RT) instability affects a vast range of High Energy Density (HED) length scales, spanning from supernova explosions (10 13 m) to inertial confinement fusion (10 -6 m). In inertial confinement fusion, the RT instability is known to induce mixing or turbulent transition, which in turn cools the hot spot and hinders ignition. The fine-scale features of the RT instability, which are difficult to image in HED physics, may help determine if the system is mixing or is transitioning to turbulence. Earlier diagnostics lacked the spatial and temporal resolution necessary to diagnose the dynamics that occur along the RT structure. A recently developed diagnostic, the Crystal Backlighter Imager (CBI), [1,2] can now produce an x-ray radiograph capable of resolving the fine-scale features expected in these RT unstable systems. This paper describes an experimental design that adapts a well-characterized National Ignition Facility (NIF) platform to accommodate the CBI diagnostic. Simulations and synthetic radiographs highlight the resolution capabilities of the CBI in comparison to previous diagnostics. Furthermore, the improved resolution of the system can provide new observations to study the RT instability's involvement in mixing and the transition to turbulence in the HED regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic and quality-assurance tools for low-contrast images obtained from array detectors

We investigate methods of estimating a background image frame for subtraction from a data frame for use when a more suitable measured background frame is not available. We define background as any signal component that is not attributable to the phenomenon currently under investigation. We describe a technique that is based on pixel-by-pixel least-squares regression of images for computing a background frame from available data. We argue that the same technique can be a useful quality-assurance tool for evaluating instrument performance. For example, it can help to separate image structure resulting from the reading process from structure resulting from the characteristics of the detector itself. We demonstrate that background estimation can be nontrivial by comparing the results of different background estimation procedures by using data obtained from a CCD array detector. We investigate the temperature-dependent contributions of the detector and readout electronics to the total signal as a demonstration of the diagnostic capabilities of least-squares image regression.

Hatfield, D. B.↗

Visualization and imaging methods for flames in microgravity

The visualization and imaging of flames has long been acknowledged as the starting point for learning about and understanding combustion phenomena. It provides an essential overall picture of the time and length scales of processes and guides the application of other diagnostics. It is perhaps even more important in microgravity combustion studies, where it is often the only non-intrusive diagnostic measurement easily implemented. Imaging also aids in the interpretation of single-point measurements, such as temperature, provided by thermocouples, and velocity, by hot-wire anemometers. This paper outlines the efforts of the Microgravity Combustion Diagnostics staff at NASA Lewis Research Center in the area of visualization and imaging of flames, concentrating on methods applicable for reduced-gravity experimentation. Several techniques are under development: intensified array camera imaging, and two-dimensional temperature and species concentrations measurements. A brief summary of results in these areas is presented and future plans mentioned.

Weiland, Karen J.↗

Evaluation of Deep Learning Model Architectures for Point-of-Care Ultrasound Diagnostics

Point-of-care ultrasound imaging is a critical tool for patient triage during trauma for diagnosing injuries and prioritizing limited medical evacuation resources. Specifically, an eFAST exam evaluates if there are free fluids in the chest or abdomen but this is only possible if ultrasound scans can be accurately interpreted, a challenge in the pre-hospital setting. In this effort, we evaluated the use of artificial intelligent eFAST image interpretation models. Widely used deep learning model architectures were evaluated as well as Bayesian models optimized for six different diagnostic models: pneumothorax (i) B- or (ii) M-mode, hemothorax (iii) B- or (iv) M-mode, (v) pelvic or bladder abdominal hemorrhage and (vi) right upper quadrant abdominal hemorrhage. Models were trained using images captured in 27 swine. Using a leave-one-subject-out training approach, the MobileNetV2 and DarkNet53 models surpassed 85% accuracy for each M-mode scan site. The different B-mode models performed worse with accuracies between 68% and 74% except for the pelvic hemorrhage model, which only reached 62% accuracy for all model architectures. These results highlight which eFAST scan sites can be easily automated with image interpretation models, while other scan sites, such as the bladder hemorrhage model, will require more robust model development or data augmentation to improve performance. With these additional improvements, the skill threshold for ultrasound-based triage can be reduced, thus expanding its utility in the pre-hospital setting.

47 OTHER INSTRUMENTATION↗

Medics: Medical Decision Support System for Long-Duration Space Exploration

The Autonomous Medical Operations (AMO) group at NASA Ames is developing a “medical decision support system” to enable astronauts on long-duration exploration missions to operate autonomously. The system will support clinical actions by providing medical interpretation advice and procedural recommendations during emergent care and clinical work performed by crew. The current state of development of the system, called MedICS (Medical Interpretation Classification and Segmentation) includes two separate aspects: a set of machine learning diagnostic models trained to analyze organ images and patient health records, and an interface to ultrasound diagnostic hardware and to medical repositories. Three sets of images of different organs and medical records were utilized for training machine learning models for various analyses, as follows: 1. Pneumothorax condition (collapsed lung). The trained model provides a positive or negative diagnosis of the condition. 2. Carotid artery occlusion. The trained model produces a diagnosis of 5 different occlusion levels (including “normal”). 3. Ocular retinal images. The model extracts optic disc pixels (image segmentation). This is a precursor step for advanced autonomous fundus clinical evaluation algorithms to be implemented in FY20. 4. Medical health records. The model produces a differential diagnosis for any particular individual, based on symptoms and other health and demographic information. A probability is calculated for each of 25 most common conditions. The same model provides the likelihood of survival. All results are provided with a confidence level. Item 1 images were provided by the US Army and were part of a data set for the clinical treatment of injured battlefield soldiers. This condition is relevant to possible space mishaps, due to pressure management issues. Item 2 images were provided by Houston Methodist Hospital, and item 3 health records were acquired from the MIT laboratory of computational physiology. The machine learning technology utilized is deep multilayer networks (Deep Learning), and new models will continue to be produced, as relevant data is made available and specific health needs of astronaut crews are identified. The interfacing aspects of the system include a GUI for running the different models, and retrieving and storing data, as well as support for integration with an augmented reality (AR) system deployed at JSC by Tietronix Software Inc. (HoloLens). The AR system provides guidance for the placement of an ultrasound transducer that captures images to be sent to the MedICS system for diagnosis. The image captured and the associated diagnosis appear in the technician’s AR visual display.

Colombano, Silvano↗