Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Diffraction paradox: An unusually broad diffraction background marks high quality graphene

The realization of the unusual properties of two-dimensional (2D) materials requires the formation of large domains of single-layer thickness, extending over the mesoscale. It is found that the formation of uniform graphene on SiC, contrary to textbook diffraction, is signaled by a strong bell-shaped component (BSC) around the (00) and G(10) spots (but not around the substrate spots). The BCS is also seen on graphene grown on metals, because a single uniform graphene layer can be also grown with large lateral size. It is only seen by electron diffraction but not with x-ray or He scattering. Although the origin of such an intriguing result is unclear, its presence in the earlier literature (but never mentioned) points to its robustness and significance. A likely mechanism relates to the the spatial confinement of the graphene electrons, within a single layer. Finally, this leads to large spread in their wave vector which is transferred by electron-electron interactions to the elastically scattered electrons to generate the BSC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diffractive Imaging of Coherent Nuclear Motion in Isolated Molecules

Observing the motion of the nuclear wave packets during a molecular reaction, in both space and time, is crucial for understanding and controlling the outcome of photoinduced chemical reactions. We have imaged the motion of a vibrational wave packet in isolated iodine molecules using ultrafast electron diffraction with relativistic electrons. The time-varying interatomic distance was measured with a precision 0.07 Å and temporal resolution of 230 fs full width at half maximum. The method is not only sensitive to the position but also the shape of the nuclear wave packet.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Size–strain separation in diffraction line profile analysis

Separation of size and strain effects on diffraction line profiles has been studied in a round robin involving laboratory instruments and synchrotron radiation beamlines operating with different radiation, optics, detectors and experimental configurations. The studied sample, an extensively ball milled iron alloy powder, provides an ideal test case, as domain size broadening and strain broadening are of comparable size. The high energy available at some synchrotron radiation beamlines provides the best conditions for an accurate analysis of the line profiles, as the size–strain separation clearly benefits from a large number of Bragg peaks in the pattern; high counts, reliable intensity values in low-absorption conditions, smooth background and data collection at different temperatures also support the possibility to include diffuse scattering in the analysis, for the most reliable assessment of the line broadening effect. However, results of the round robin show that good quality information on domain size distribution and microstrain can also be obtained using standard laboratory equipment, even when patterns include relatively few Bragg peaks, provided that the data are of good quality in terms of high counts and low and smooth background.

Scardi, P. (ORCID:0000000310973917)↗

X-ray nanoprobes and diffraction-limited storage rings: opportunities and challenges of fluorescence tomography of biological specimens

X-ray nanoprobes require coherent illumination to achieve optic-limited resolution, and so will benefit directly from diffraction-limited storage rings. Here, the example of high-resolution X-ray fluorescence tomography is focused on as one of the most voracious demanders of coherent photons, since the detected signal is only a small fraction of the incident flux. Alternative schemes are considered for beam delivery, sample scanning and detectors. One must consider as well the steps before and after the X-ray experiment: sample preparation and examination conditions, and analysis complexity due to minimum dose requirements and self-absorption. By understanding the requirements and opportunities for nanoscale fluorescence tomography, one gains insight into the R&D challenges in optics and instrumentation needed to fully exploit the source advances that diffraction-limited storage rings offer.

de Jonge, Martin D.↗

In Situ Diffraction from Levitated Solids Under Extreme Conditions—Structure and Thermal Expansion in the Eu 2 O 3 –ZrO 2 System

The accurate determination of structure and thermal expansion of refractory materials at temperatures above 1500°C is challenging. Here, for the first time, we demonstrate the ability to reliably refine the structure and thermal expansion coefficient of oxides at temperatures to 2200°C using in situ synchrotron diffraction coupled with aerodynamic levitation. Solid solutions in the Eu 2 O 3 –ZrO 2 binary system were investigated, including the high‐temperature order–disorder transformation in Eu 2 Zr 2 O 7 . The disordered fluorite phase is found to be stable above 1900°C, and a reversible phase transition to the pyrochlore phase is noticed during cooling. Site occupancies in Eu 2 Zr 2 O 7 show a gradual increase in disorder on both cation and anion sublattices with increasing temperature. The thermal expansion coefficients of all cubic solid solutions are relatively similar, falling in the range 8.6–12.0 × 10 −6 C −1 . These studies open new vistas for in situ exploration of complex structural changes in high‐temperature materials.

Maram, Pardha S.↗

Residual Stress Modeling and Advanced Diffraction Measurements of 347H Steel Weldments

The 347H stainless steel is a primary high-temperature material for many energy and power generation industries. Stress relief cracking (SRC) has been a particular concern in welding of this material. The residual stress induced by welding and its evolution during post-welding heat treatment (PWHT) and subsequent operating and service conditions is one of the primary factors contributing to SRC. The lifetime of welded structure components is also controlled by the precipitation kinetics that accompanies PWHT, stress relaxation process, and long-term aging and complex synergistic factors. Various theories have been proposed in the past to explain SRC. However, a widely accepted approach to predicting the entire damage evolution and the resulting performance reduction is still lacking. This study is to demonstrate a reliable solution for two critical issues that affect the predictions. First, the residual stress distribution obtained from both simulation and neutron diffraction is compared, which increases the accuracy of mechanical analysis simulation model and therefore builds a solid basis for the lifetime prediction model. Second, the generation, evolution, and annihilation of precipitates are monitored by the synchrotron diffraction experiment. Preliminary results demonstrate the critical importance of precipitation kinetics on the residual stress distribution/redistribution during heat treatments.

Yang, Yi↗

Rapid feedback of chemical vapor deposition growth mechanisms by operando X-ray diffraction

An operando x-ray diffraction system is presented for elucidating optimal laser assisted chemical vapor deposition growth conditions. The technique is utilized to investigate deposition dynamics of boron-carbon materials using trimethyl borate precursor. Trimethyl borate exhibits vastly reduced toxicological and flammability hazards compared to existing precursors, but has previously not been applied to boron carbide growth. Crystalline boron-rich carbide material is produced in a narrow growth regime on addition of hydrogen during the growth phase at high temperature. Finally, the use of the operando x-ray diffraction system allows for the exploration of highly nonequilibrium conditions and rapid process control, which are not possible using ex situ diagnostics.

36 MATERIALS SCIENCE↗

Fibre Diffraction Analysis of Skin Offers a Very Early and Extremely Accurate Diagnostic Test for Prostate Cancer

Double blind analysis of a batch of thirty skin tissue samples from potential prostate cancer sufferers correctly identified all “control” patients, patients with high and low grade prostate cancers, the presence of benign prostate hyperplasia (BPH), perineural invasions, and the one lymphatic invasion. Identification was by analysis of fibre diffraction patterns interpreted using a schema developed from observations in nine previous studies. The method, schema, and specific experiment results are reported in this paper, with some implications then drawn.

James, Veronica J.↗

Diffraction limited focusing and routing of gap plasmons by a metal-dielectric-metal lens

Passive optical elements can play key roles in photonic applications such as plasmonic integrated circuits. Here we experimentally demonstrate passive gap-plasmon focusing and routing in two-dimensions. This is accomplished using a high numerical-aperture metal-dielectric-metal lens incorporated into a planar-waveguide device. Fabrication via metal sputtering, oxide deposition, electron- and focused-ion- beam lithography, and argon ion-milling is reported on in detail. Diffraction-limited focusing is optically characterized by sampling out-coupled light with a microscope. The measured focal distance and full-width-half-maximum spot size agree well with the calculated lens performance. The surface plasmon polariton propagation length is measured by sampling light from multiple out-coupler slits.

42 ENGINEERING↗

Exploring 2D X-ray diffraction phase fraction analysis with convolutional neural networks: Insights from kinematic-diffraction simulations

Abstract Deep-learning models are effective for analyzing the complex information in 2D X-ray diffraction (XRD) patterns. Accurately collecting parameters of the material sample is crucial during model training, significantly impacting model performance. In this study, we employ a kinematic-diffraction simulator to generate simulated 2D XRD patterns for Ti–6Al–4V alloy, allowing precise control of sample parameters. These simulated patterns are used to train convolutional neural networks, predicting $$\upbeta$$ β -phase volume fractions. The training data set consists exclusively of 2D XRD patterns with pure $$\upalpha$$ α - or pure $$\upbeta$$ β -phase, while the testing set incorporates patterns with intermediate phase volume fraction. In particular, we investigate how the architectures of the model influence prediction reliability and computational performance. Experimental results reveal that, with appropriate training, the convolutional neural network accurately detects intermediate phase volume fractions even trained with only pure-phase patterns, achieving a mean square error accuracy of $$9.4 \times 10^{-4}$$ 9.4 × 10 - 4 . Graphical abstract

Yue, Weiqi↗

Electromagnetic diffraction efficiencies for plane reflection diffraction gratings

The theory and computer programs, based on electromagnetic theory, for the analysis and design of echelle gratings were developed. The gratings are designed for instruments that operate in the ultraviolet portion of the spectrum. The theory was developed so that the resulting computer programs will be able to analyze deep (up to 30 wavelengths) gratings by including as many as 100 real or homogeneous diffraction orders. The program calculates the complex amplitude coefficient for each of the diffracted orders. A check on the numerical method used to solve the integral equations is provided by a conservation of energy calculation.

Marathay, A. S.↗

Isotropic etchback method of linewidth tailoring multilayer dielectric diffraction gratings for improvement of laser damage resistance and diffraction efficiency

A method of fabricating a multilayer dielectric (MLD) diffraction grating by providing a multilayer stack having a grating layer, and anisotropically etching the grating layer to form grating lines having an initial lineheight, an initial linewidth, and an initial grating duty cycle, that are greater than a target lineheight, a target linewidth, and a target grating duty cycle, respectively. An isotropic wet etch solution is then used to etch back the grating lines to the target lineheight, the target linewidth, and the target grating duty cycle so as to minimize electric field intensities and maximize diffraction efficiency for a given set of MLD illumination conditions.

Britten, Jerald A.↗

High energy X-ray diffraction study of the relationship between the macroscopic mechanical properties and microstructure of irradiated HT-9 steel

Samples harvested from an HT-9 fuel test assembly (ACO-3) irradiated for six years in the Fast Flux Test Facility (FFTF) reaching 2–147 dpa at 382–504°C were deformed in-situ while collecting high-energy X-ray diffraction data to monitor microstructure evolution. With the initiation of plastic deformation, all samples exhibited a clear load transfer from the ferrite matrix to carbide particulate. This behavior was confirmed by modeling of the control material. The evolution of dislocation density in the material as a result of deformation was characterized through full pattern line profile analysis. The dislocation densities increased substantially after deformation, the level of dislocation evolution observed was highly dependent upon the irradiation temperature of the sample. The differences in both the yield and hardening behavior between samples irradiated at higher and lower temperatures suggest the existence of a transition in tensile behavior at an irradiation temperature near 420°C dividing regions of distinct damage effects.

36 MATERIALS SCIENCE↗