X-ray nanoprobes and diffraction-limited storage rings: opportunities and challenges of fluorescence tomography of biological specimens

X-ray nanoprobes require coherent illumination to achieve optic-limited resolution, and so will benefit directly from diffraction-limited storage rings. Here, the example of high-resolution X-ray fluorescence tomography is focused on as one of the most voracious demanders of coherent photons, since the detected signal is only a small fraction of the incident flux. Alternative schemes are considered for beam delivery, sample scanning and detectors. One must consider as well the steps before and after the X-ray experiment: sample preparation and examination conditions, and analysis complexity due to minimum dose requirements and self-absorption. By understanding the requirements and opportunities for nanoscale fluorescence tomography, one gains insight into the R&D challenges in optics and instrumentation needed to fully exploit the source advances that diffraction-limited storage rings offer.

de Jonge, Martin D.↗

In Situ Diffraction from Levitated Solids Under Extreme Conditions—Structure and Thermal Expansion in the Eu 2 O 3 –ZrO 2 System

The accurate determination of structure and thermal expansion of refractory materials at temperatures above 1500°C is challenging. Here, for the first time, we demonstrate the ability to reliably refine the structure and thermal expansion coefficient of oxides at temperatures to 2200°C using in situ synchrotron diffraction coupled with aerodynamic levitation. Solid solutions in the Eu 2 O 3 –ZrO 2 binary system were investigated, including the high‐temperature order–disorder transformation in Eu 2 Zr 2 O 7 . The disordered fluorite phase is found to be stable above 1900°C, and a reversible phase transition to the pyrochlore phase is noticed during cooling. Site occupancies in Eu 2 Zr 2 O 7 show a gradual increase in disorder on both cation and anion sublattices with increasing temperature. The thermal expansion coefficients of all cubic solid solutions are relatively similar, falling in the range 8.6–12.0 × 10 −6 C −1 . These studies open new vistas for in situ exploration of complex structural changes in high‐temperature materials.

Maram, Pardha S.↗

Residual Stress Modeling and Advanced Diffraction Measurements of 347H Steel Weldments

The 347H stainless steel is a primary high-temperature material for many energy and power generation industries. Stress relief cracking (SRC) has been a particular concern in welding of this material. The residual stress induced by welding and its evolution during post-welding heat treatment (PWHT) and subsequent operating and service conditions is one of the primary factors contributing to SRC. The lifetime of welded structure components is also controlled by the precipitation kinetics that accompanies PWHT, stress relaxation process, and long-term aging and complex synergistic factors. Various theories have been proposed in the past to explain SRC. However, a widely accepted approach to predicting the entire damage evolution and the resulting performance reduction is still lacking. This study is to demonstrate a reliable solution for two critical issues that affect the predictions. First, the residual stress distribution obtained from both simulation and neutron diffraction is compared, which increases the accuracy of mechanical analysis simulation model and therefore builds a solid basis for the lifetime prediction model. Second, the generation, evolution, and annihilation of precipitates are monitored by the synchrotron diffraction experiment. Preliminary results demonstrate the critical importance of precipitation kinetics on the residual stress distribution/redistribution during heat treatments.

Yang, Yi↗

Rapid feedback of chemical vapor deposition growth mechanisms by operando X-ray diffraction

An operando x-ray diffraction system is presented for elucidating optimal laser assisted chemical vapor deposition growth conditions. The technique is utilized to investigate deposition dynamics of boron-carbon materials using trimethyl borate precursor. Trimethyl borate exhibits vastly reduced toxicological and flammability hazards compared to existing precursors, but has previously not been applied to boron carbide growth. Crystalline boron-rich carbide material is produced in a narrow growth regime on addition of hydrogen during the growth phase at high temperature. Finally, the use of the operando x-ray diffraction system allows for the exploration of highly nonequilibrium conditions and rapid process control, which are not possible using ex situ diagnostics.

36 MATERIALS SCIENCE↗

Fibre Diffraction Analysis of Skin Offers a Very Early and Extremely Accurate Diagnostic Test for Prostate Cancer

Double blind analysis of a batch of thirty skin tissue samples from potential prostate cancer sufferers correctly identified all “control” patients, patients with high and low grade prostate cancers, the presence of benign prostate hyperplasia (BPH), perineural invasions, and the one lymphatic invasion. Identification was by analysis of fibre diffraction patterns interpreted using a schema developed from observations in nine previous studies. The method, schema, and specific experiment results are reported in this paper, with some implications then drawn.

James, Veronica J.↗

Diffraction limited focusing and routing of gap plasmons by a metal-dielectric-metal lens

Passive optical elements can play key roles in photonic applications such as plasmonic integrated circuits. Here we experimentally demonstrate passive gap-plasmon focusing and routing in two-dimensions. This is accomplished using a high numerical-aperture metal-dielectric-metal lens incorporated into a planar-waveguide device. Fabrication via metal sputtering, oxide deposition, electron- and focused-ion- beam lithography, and argon ion-milling is reported on in detail. Diffraction-limited focusing is optically characterized by sampling out-coupled light with a microscope. The measured focal distance and full-width-half-maximum spot size agree well with the calculated lens performance. The surface plasmon polariton propagation length is measured by sampling light from multiple out-coupler slits.

42 ENGINEERING↗

Exploring 2D X-ray diffraction phase fraction analysis with convolutional neural networks: Insights from kinematic-diffraction simulations

Abstract Deep-learning models are effective for analyzing the complex information in 2D X-ray diffraction (XRD) patterns. Accurately collecting parameters of the material sample is crucial during model training, significantly impacting model performance. In this study, we employ a kinematic-diffraction simulator to generate simulated 2D XRD patterns for Ti–6Al–4V alloy, allowing precise control of sample parameters. These simulated patterns are used to train convolutional neural networks, predicting $$\upbeta$$ β -phase volume fractions. The training data set consists exclusively of 2D XRD patterns with pure $$\upalpha$$ α - or pure $$\upbeta$$ β -phase, while the testing set incorporates patterns with intermediate phase volume fraction. In particular, we investigate how the architectures of the model influence prediction reliability and computational performance. Experimental results reveal that, with appropriate training, the convolutional neural network accurately detects intermediate phase volume fractions even trained with only pure-phase patterns, achieving a mean square error accuracy of $$9.4 \times 10^{-4}$$ 9.4 × 10 - 4 . Graphical abstract

Yue, Weiqi↗

Isotropic etchback method of linewidth tailoring multilayer dielectric diffraction gratings for improvement of laser damage resistance and diffraction efficiency

A method of fabricating a multilayer dielectric (MLD) diffraction grating by providing a multilayer stack having a grating layer, and anisotropically etching the grating layer to form grating lines having an initial lineheight, an initial linewidth, and an initial grating duty cycle, that are greater than a target lineheight, a target linewidth, and a target grating duty cycle, respectively. An isotropic wet etch solution is then used to etch back the grating lines to the target lineheight, the target linewidth, and the target grating duty cycle so as to minimize electric field intensities and maximize diffraction efficiency for a given set of MLD illumination conditions.

Britten, Jerald A.↗

High energy X-ray diffraction study of the relationship between the macroscopic mechanical properties and microstructure of irradiated HT-9 steel

Samples harvested from an HT-9 fuel test assembly (ACO-3) irradiated for six years in the Fast Flux Test Facility (FFTF) reaching 2–147 dpa at 382–504°C were deformed in-situ while collecting high-energy X-ray diffraction data to monitor microstructure evolution. With the initiation of plastic deformation, all samples exhibited a clear load transfer from the ferrite matrix to carbide particulate. This behavior was confirmed by modeling of the control material. The evolution of dislocation density in the material as a result of deformation was characterized through full pattern line profile analysis. The dislocation densities increased substantially after deformation, the level of dislocation evolution observed was highly dependent upon the irradiation temperature of the sample. The differences in both the yield and hardening behavior between samples irradiated at higher and lower temperatures suggest the existence of a transition in tensile behavior at an irradiation temperature near 420°C dividing regions of distinct damage effects.

36 MATERIALS SCIENCE↗

Correlated high-resolution x-ray diffraction photoluminescence and atom probe tomography analysis of continuous and discontinuous In x Ga 1-x N quantum wells

In this study, atom probe tomography (APT) is used to characterize the influence of hydrogen dosing duringGaN barrier growth on the indium distribution of In x Ga 1-x N quantum wells, and correlatedmicro-photoluminescence is used to measure changes in the emission spectrum and efficiency. We found that relative to the control growth, hydrogen dosing leads to a 50% increase in emission intensity arising from discontinuous quantum wells that are narrower, of lower indium content, and with more abrupt interfaces. Additionally, simulations of carrier distributions based on APT composition profiles indicate that the greater carrier confinement leads to an increased radiative recombination rate. Furthermore, APT analysis of quantum well profiles enables refinement of x-ray diffractionanalysis for more accurate nondestructive measurements of composition.

36 MATERIALS SCIENCE↗

X-ray Absorption and Diffraction Studies of the Mixed-phase State of (CrxV1-x)2O3

X-ray diffraction and vanadium x-ray absorption near-edge structure (XANES) data have been obtained for (V{sub 1-x}Cr{sub x}){sub 2}O{sub 3} samples containing several concentrations of Cr, crossing the metal-insulator transition boundary. For single-phase single-crystal samples our theoretical results are generally in good qualitative agreement with our experimental single-crystal XANES, for both crystal orientations relative to the incident-beam electric vector. However, an anomalous peak occurs for both orientations in the K pre-edge of the single-crystal sample containing 1.2% Cr, a paramagnetic insulator sample that is in the concentration regime corresponding to the room-temperature two-phase (coexistence) region of the phase diagram. Upon increasing the temperature of the 0.4% Cr powdered material to 400 K so that one enters the two-phase region of the phase diagram, a similar peak appears and then diminishes at 600 K. These results, as well as experiments done by others involving room-temperature and low-temperature XANES of a 1.1% Cr sample, suggest that this feature in the V pre-edge structure is associated with the appearance under some circumstances of a small amount of highly distorted VO{sub 6} octahedra in the interface region between coexisting metal and insulating phases. Finally, we find that, for the two-phase regime, the concentration ratio of the metal-to-insulating phase varies between different regions from a sample batch of uniform composition made by the skull melting method.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cryogenic X-Ray Diffraction Microscopy for Biological Samples

X-ray diffraction microscopy (XDM) is well suited for nondestructive, high-resolution biological imaging, especially for thick samples, with the high penetration power of x rays and without limitations imposed by a lens. We developed nonvacuum, cryogenic (cryo-) XDM with hard x rays at 8 keV and report the first frozen-hydrated imaging by XDM. By preserving samples in amorphous ice, the risk of artifacts associated with dehydration or chemical fixation is avoided, ensuring the imaging condition closest to their natural state. The reconstruction shows internal structures of intact D. radiodurans bacteria in their natural contrast.