Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Dynamical theoretical model of the high-resolution double-crystal x-ray diffractometry of imperfect single crystals with microdefects

The dynamical diffraction model has been developed for the quantitative description of rocking curves (RCs) measured in the Bragg diffraction geometry from single crystals containing homogeneously distributed microdefects of several types and with arbitrary sizes. The analytical expressions for coherent and diffuse RC components, which take self-consistently multiple-scattering effects into account and depend explicitly on microdefect characteristics (radius, concentration, strength, etc.), have been derived with taking into account the instrumental factors. The developed model has been applied to determine the characteristics of oxygen precipitates and dislocation loops in silicon crystals grown by Czochralsky and float-zone methods using RCs measured by the high-resolution double-crystal x-ray diffractometer. It has been shown, particularly, that completely dynamical consideration of Huang as well as Stockes-Wilson diffuse scattering (DS) in both diffuse RC component and coefficient of extinction of coherent RC component due to DS, together with taking asymmetry and thermal DS effects into account, provides the possibility to distinguish contributions into RC from defects of different types, which have equal or commensurable effective radii.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Atomic Pair Distribution Function Analysis from the ARCS Chopper Spectrometer at the Spallation Neutron Source

Neutron powder-diffraction-based atomic pair distribution functions (PDFs) are reported from the new wide-angular-range chopper spectrometer ARCS at the Spallation Neutron Source at Oak Ridge National Laboratory. The spectrometer was run in white-beam mode with no Fermi chopper. The PDF patterns of Ni and Al2O3 were refined using the PDFfit method and the results compared with data collected at the NPDF diffractometer at Los Alamos National Laboratory. The resulting fits are of high quality, demonstrating that quantitatively reliable powder diffraction data can be obtained from ARCS when operated in this configuration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Use of a hexapod in diffraction measurements of substrate supported crystals of organic semiconductors

Thin films of organic semiconductor prepared on substrates generally contain crystals that have one common crystal plane parallel to the substrate but random in-plane orientations. In diffraction measurements of these structures, it is often required to anchor the X-ray beam on a fixed spot on the sample, such as an optically visible crystallite or island. Here, a hexapod is used in place of a traditional multi-circle diffractometer to perform area-detector-based diffraction measurements on an actual device that contains 6,13-bis(triisopropylsilyethynyl)-pentacene (TIPS-pentacene) crystals. The hexapod allows for sample rotations about any user-defined rotation center. Two types of complex sample motions have been programmed to characterize the structure of the TIPS-pentacene crystal: an in-plane powder average has been performed at a fixed grazing-incident angle to determine the lattice parameters of the crystal; then the in-plane component of the scattering vector was continuously rotated in transmission geometry to determine the local crystal orientation.

47 OTHER INSTRUMENTATION↗

Ultra-small-angle neutron scattering with azimuthal asymmetry

Small-angle neutron scattering (SANS) measurements from thin sections of rock samples such as shales demand as great a scattering vector range as possible because the pores cover a wide range of sizes. The limitation of the scattering vector range for pinhole SANS requires slit-smeared ultra-SANS (USANS) measurements that need to be converted to pinhole geometry. The desmearing algorithm is only successful for azimuthally symmetric data. Scattering from samples cut parallel to the plane of bedding is symmetric, exhibiting circular contours on a two-dimensional detector. Samples cut perpendicular to the bedding show elliptically dependent contours with the long axis corresponding to the normal to the bedding plane. A method is given for converting such asymmetric data collected on a double-crystal diffractometer for concatenation with the usual pinhole-geometry SANS data. Furthermore, the aspect ratio from the SANS data is used to modify the slit-smeared USANS data to produce quasi-symmetric contours. Rotation of the sample about the incident beam may result in symmetric data but cannot extract the same information as obtained from pinhole geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A preliminary neutron crystallographic study of proteinase K at pD 6.5

A preliminary neutron crystallographic study of the proteolytic enzyme proteinase K is presented. Large hydrogenated crystals were prepared in deuterated crystallization buffer using the vapour-diffusion method. Data were collected to a resolution of 2.3 Å on the LADI-III diffractometer at the Institut Laue Langevin (ILL) in 2.5 days. The results demonstrate the feasibility of a full neutron crystallographic analysis of this structure aimed at providing relevant information on the location of H atoms, particularly at the active site. This information will contribute to further understanding of the molecular mechanisms underlying proteinase K's catalytic activity and to an enriched understanding of the subtilisin clan of serine proteases.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Structure of Yttrialite and Its Identification Using Laboratory and Synchrotron-Based Powder X-Ray Diffraction

A highly crystalline sample of the impurity stabilized phase y-Y{sub 2}Si{sub 2}O{sub 7}, generally known as yttrialite, has been formed from the melt of a glass with a nominal composition of 62(SiO{sub 2})-10(Al{sub 2}O{sub 3})-28(Y{sub 2}O{sub 3}) mol%. Powder X-ray diffraction patterns were collected using in-house instrumentation and the 11-BM diffractometer at the Advanced Photon Source, Argonne National Laboratory, Argonne, IL. Rietveld refinements were carried out on the patterns using two structural models. On patterns collected using in-house instrumentation the correct structure assignment was difficult to determine; however, the extremely high-quality data afforded by the 11-BM instrument showed conclusively that the sample was found to crystallize in the monoclinic system (SG=P2{sub 1}/m) with lattice parameters a=5.03032(6), b=8.06892(6), c=7.33620(6) {angstrom}, and {beta} = 108.673(1). Furthermore, simulations have shown that it is likely that this structure model can be used to describe natural yttrialite or yttrialite that is formed at low temperatures, though the possibility that such materials are paracrystalline is also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Beyond hard x-ray photoelectron spectroscopy: Simultaneous combination with x-ray diffraction

Hard x-ray photoelectron spectroscopy (HAXPES) is a powerful and novel emerging technique for the nondestructive determination of electronic properties and chemical composition of bulk, buried interfaces and surfaces. It benefits from the exceptionally large escape depth of high kinetic energy photoelectrons, increasing the information depth up to several tens of nanometers. Complementing HAXPES with an atomic structure sensitive technique (such as x-ray diffraction) opens a new research field with major applications for materials science. At SpLine, the Spanish CRG beamline at the European Synchrotron Radiation Facility, we have developed a novel experimental set-up that combines HAXPES and x-ray diffraction (x-ray reflectivity, surface x-ray diffraction, grazing incidence x-ray diffraction, and reciprocal space maps). Both techniques can be operated simultaneously on the same sample and using the same excitation source. The set-up includes a robust 2S + 3D diffractometer hosting a ultrahigh vacuum chamber equipped with a unique photoelectron spectrometer (few eV < electron kinetic energy < 15 keV), x-ray tube (Mg/Ti), 15 keV electron gun, and auxiliary standard surface facilities (molecular beam epitaxy evaporator, ion gun, low energy electron diffraction, sample heating/cooling system, leak valves, load-lock sample transfer, etc.). This end-station offers the unique possibility of performing simultaneous HAXPES + x-ray diffraction studies. In the present work, we describe the experimental set-up together with two experimental examples that emphasize its outstanding capabilities: (i) nondestructive characterization of the Si/Ge and HfO{sub 2}/SiO{sub 2} interfaces on Ge-based CMOS devices, and (ii) strain study on La{sub 0.7}Ca{sub 0.3}MnO{sub 3} ultrathin films grown on SrTiO{sub 3}(001) substrate.

36 MATERIALS SCIENCE↗

Optical properties and crystallinity of silver mirrors under a 35 krad cobalt-60 radiation

This study addresses the effects of thin film optical design and environmental radiation on the optical properties of silver mirrors. Different experimental thin film optical designs are selected, and the film stack is built using Macleod's approach. Mirror elements are exposed to the same dose of radiation and their properties are characterized using a spectrophotometer equipped with an integration sphere and an x-ray diffractometer. Spectrophotometric analyses of mirrors exposed to about 35 krad of {sup 60}Co radiations overall show that the B270 glass substrates coated with titanium oxide (TiO{sub 2}), silicon dioxide (SiO{sub 2}), pure chrome, and pure silver effectively reduces radiation damage. The absorption spectrum of the TiO{sub 2} film in the visible region decreases after radiation and displays drifting. As thin metal films comparison, the silver thin film exhibits higher radiation resistance than the chrome thin film. The x-ray diffraction analysis on metal film layers reveals that crystallinity slightly increases when the silver thin film is irradiated.

36 MATERIALS SCIENCE↗

The diagnostic capability of x-ray scattering parameters for the characterization of breast cancer

Purpose: The evaluation of the diagnostic capability of easy to measure x-ray scattering profile characterization parameters for the detection of breast cancer in excised samples. The selected parameters are the full width at half maximum (FWHM) and area under the x-ray scattering profile of breast tissue in addition to the ratio of scattering intensities (I{sub 2}/I{sub 1}%) at 1.6 nm{sup -1} to that at 1.1 nm{sup -1} (corresponding to scattering from soft and adipose tissues, respectively). Methods: A histopathologist is asked to classify 36 excised breast tissue samples into healthy or malignant. A conventional x-ray diffractometer is used to acquire the scattering profiles of the investigated samples. The values of three profile characterization parameters are calculated and the diagnostic capability of each is evaluated by determining the optimal cutoffs of scatter diagrams, calculating the diagnostic indices, and plotting the receiver operating characteristic (ROC) curves. Results: At the calculated optimal cutoff for each of the examined parameters, the sensitivity ranged from 78% (for area under curve) up to 94% (for FWHM), the specificity ranged from 94%[for I{sub 2}/I{sub 1}% and area under curve] up to 100% (for FWHM), and the diagnostic accuracy ranged from 86% (for area under curve) up to 97% (for FWHM). The area under the ROC curves is greater than 0.95 for all of the investigated parameters, reflecting a highly accurate diagnostic performance. Conclusions: The discussed tests offered a means to quantitatively evaluate the performance of the suggested breast tissue x-ray scattering characterization parameters. The performance results are promising, indicating that the evaluated parameters would be considered a tool for fast, on spot probing of breast cancer in excised tissue samples.

60 APPLIED LIFE SCIENCES↗

On the surface shape of an X-ray monochromator

It is established that the surface of a monochromator for a point X-ray source in diffractometers is the surface of revolution of a circle arc around the straight line connecting the X-ray source and detector. It is shown that scattering occurs at the points of intersection of the monochromator surface with the set of ellipsoids of revolution, in whose focuses the X-ray source and detector are located. A formula is obtained for calculating the misorientation angle of mosaic blocks. The limits of variation in the angle for FeK{sub {alpha}} {sub 1}, CuK{sub {alpha}} {sub 1} and MoK{sub {alpha}} {sub 1} radiations are determined. It is shown that there is no unified continuous reflecting monochromator surface, and the true reflecting surface is fractal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nontrivial role of the resolution function in the formation of double-crystal X-ray rocking curves

A theoretical analysis of the shape of the resolution function of an X-ray diffractometer in the double-crystal nondispersive scheme for measuring rocking curves has been performed. It is shown that this function, along with the strong narrow central line (corresponding to the characteristic line to which the collimator crystal and slits in the experimental scheme are tuned) always contains an additional weak satellite, corresponding to the neighboring characteristic line. This feature manifests itself in experimental curves as an additional pseudopeak, whose intensity is comparable with the corresponding diffraction scattering intensity from a sample in the fundamental characteristic line, and whose shape and exact position are set by the resolution function in a specific experimental scheme. It is shown that the exact allowance for the angular and spectral distribution of incident radiation in the double-crystal scheme makes it possible to precisely determine the parameters of the structures studied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Similar quartz crystallographic textures in rocks of continental earth's crust (by neutron diffraction data): I. Quartz textures in monomineral rocks

Quartz crystallographic textures in different rocks have been investigated by neutron diffraction. Various types of crystallographic textures of quartz-bearing mineral associations in monomineral and multiphase rocks from a representative collection of samples have been revealed and classified. Experimental investigations have been performed on special neutron texture diffractometers designed at the Frank Laboratory of Neutron Physics and mounted in the seventh channel of the IBR-2 reactor at the Joint Institute for Nuclear Research (Dubna).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Single-crystal structures of high-pressure phases FeOOH, FeOOD, and GaOOH

The structures of the {epsilon}-FeOOH, {epsilon}-FeOOD, and {beta}-GaOOH phases, which belong to the InOOH structure type (the distorted TiO{sub 2} structure type), are determined using single-crystal X-ray diffraction analysis. The measurements are performed on Xcalibur CCD and CAD-4F diffractometers. The calculations are carried out in space group P2{sub 1nm} with the JANA2000 program. The crystals are twinned and form aggregates related by the rotation around the b axis through an angle close to 62{sup o}. In the same crystals, the merohedral twinning is characterized by the rotation around the c axis through an angle of 180{sup o}. The alternation of these twin domains in the bulk of the crystal determines the corresponding disordering of the hydrogen positions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laboratory X-ray microtomographs with the use of monochromatic radiation

The possibility and expediency of designing X-ray microtomographs based on X-ray diffractometers have been analyzed. Some biomedical objects have been investigated. It has been demonstrated that it is possible to achieve a resolution of the order 10 {mu}m with a field of view of the order of 20 mm without recourse to magnifying X-ray optical elements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Crystal structure refinement of Sr{sub 3}TaGa{sub 3}Si{sub 2}O{sub 14}

An accurate X-ray diffraction study of Sr{sub 3}TaGa{sub 3}Si{sub 2}O{sub 14} (STGS) crystal (a = 8.3023(10) Angstrom-Sign , c = 5.0853(2) Angstrom-Sign , sp. gr. P321, Z = 1, R/wR = 0.59/0.52%, 4004 independent reflections) is performed. The use of two independent data sets obtained on diffractometers with point and 2D detectors made it possible to determine the model structure characterized by the best reproducibility of parameters. The ordered distribution of atoms over crystallographic positions and the anharmonic character of displacements of all cations and one oxygen atom are established.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accurate structural study of langasite-family Ca{sub 3}TaGa{sub 3}Si{sub 2}O{sub 14} crystal

An accurate X-ray diffraction study of Ca{sub 3}TaGa{sub 3}Si{sub 2}O{sub 14} single crystal has been performed using two datasets obtained on a diffractometer equipped with a CCD area detector (a = 8.1056(2) Å, c = 4.9800(1) Å, sp. gr. P321, Z = 1, R/wR = 0.486/0.488%). A model structure is determined which is characterized by a high degree of reproducibility of structural parameters. Each site in Ca{sub 3}TaGa{sub 3}Si{sub 2}O{sub 14} is occupied by atoms of only one type. Nevertheless, its structural feature is asymmetric disordering of sites of Ca, Ta, Ga, and two out of three oxygen atoms occupying special and general sites. A transition of some part of Ca atoms (~3%) from 3e sites on the twofold symmetry axis to general 6g sites is revealed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Crystal structure of Rb{sub 2}Mn{sub 3}(H{sub 2}O){sub 2}[P{sub 2}O{sub 7}]{sub 2}, a new representative of the family of hydrated diphosphates

The crystal structure of Rb{sub 2}Mn{sub 3}(H{sub 2}O){sub 2}[P{sub 2}O{sub 7}]{sub 2}, a new phase obtained in the form of single crystals under hydrothermal conditions in the MnCl{sub 2}–Rb{sub 3}PO{sub 4}–H{sub 2}O system, is determined by X-ray diffraction (Xcalibur-S-CCD diffractometer, R = 0.0270): a = 9.374(2), b = 8.367(2), c = 9.437(2) Å, ß = 99.12(2)°, space group P2{sub 1}/c, Z = 2, D{sub x} = 3.27 g/cm{sup 3}. A correlation between the unit-cell parameters and the size of cations forming the crystal structures of isostructural A{sub 2}M{sub 3}(H{sub 2}O){sub 2}[P{sub 2}O{sub 7}]{sub 2} diphosphates (A = K, NH{sub 4}, Rb, or Na; {sub M} = Mn, Fe, Co, or Ni) is revealed. It is shown that, due to the topological similarity, the structures of diphosphates and orthophosphates of the farringtonite structural type can undergo mutual transformations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New multicell model for describing the atomic structure of La{sub 3}Ga{sub 5}SiO{sub 14} piezoelectric crystal: Unit cells of different compositions in the same single crystal

Accurate X-ray diffraction study of langasite (La{sub 3}Ga{sub 5}SiO{sub 14}) single crystal has been performed using the data obtained on a diffractometer equipped with a CCD area detector at 295 and 90.5 K. Within the known La{sub 3}Ga{sub 5}SiO{sub 14} model, Ga and Si cations jointly occupy the 2d site. A new model of a “multicell” consisting of two different unit cells is proposed. Gallium atoms occupy the 2d site in one of these cells, and silicon atoms occupy this site in the other cell; all other atoms correspondingly coordinate these cations. This structure implements various physical properties exhibited by langasite family crystals. The conclusions are based on processing four data sets obtained with a high resolution (sin θ/λ ≤ 1.35 Å{sup –1}), the results reproduced in repeated experiments, and the high relative precision of the study (sp. gr. P321, Z = 1; at 295 K, a = 8.1652(6) Å, c = 5.0958(5) Å, R/wR = 0.68/0.68%, 3927 independent reflections; at 90.5 K, a = 8.1559(4) Å, c = 5.0913(6) Å, R/wR = 0.92/0.93%, 3928 reflections).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗