Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distance Based Approximation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Enhanced target normal sheath acceleration based on the laser relativistic self-focusing

The enhanced target normal sheath acceleration of ions in laser target interaction via the laser relativistic self-focusing effect is investigated by theoretical analysis and particle-in-cell simulations. The temperature of the hot electrons in the underdense plasma is greatly increased due to the occurrence of resonant absorption, while the electron-betatron-oscillation frequency is close to its witnessed laser frequency [Pukhov et al., Phys. Plasma 6, 2847 (1999)]. While these hot electrons penetrate through the backside solid target, a stronger sheath electric field at the rear surface of the target is induced, which can accelerate the protons to a higher energy. It is also shown that the optimum length of the underdense plasma is approximately equal to the self-focusing distance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanofabrication and Demonstration of a Direct-Write Microevaporator

Direct-write vapor deposition is a new technique that would enable one-step 3D maskless nanofabrication on a variety of substrates. A novel silicon chip-based microevaporator is developed that allows evaporant to exit through 2000–300 nm nozzles while held at distances comparable to the nozzle diameter from the substrate by a three-axis nanopositioning stage in vacuum. This results in a localized deposition on the substrate, which may be scanned relative to the substrate to produce direct-write patterns. The performance of the microevaporator is tested by creating localized depositions of various materials and the line-writing potential is demonstrated. The relationship between linewidth and source-to-substrate distance is investigated by the application of Knudsen's cosine law and Monte-Carlo simulations, and then utilized to approximate the source-to-substrate distance from performed depositions.

36 MATERIALS SCIENCE↗

Observables, gravitational dressing, and obstructions to locality and subsystems

Quantum field theory - our fundamental framework for describing all non-gravitational physics - conflicts with general relativity: the latter precludes the standard definition of the former's essential principle of locality, in terms of commuting local observables. We explore this conflict more carefully, by investigating implications of gauge (diffeomorphism) invariance for observables in gravity. We prove a dressing theorem, showing that any operator with nonzero Poincare charges, and in particular any compactly-supported operator, in flat-spacetime quantum field theory must be gravitationally dressed once coupled to gravity, i.e. it must depend on the metric at arbitrarily long distances, and we put lower bounds on this nonlocal dependence. This departure from standard locality occurs in the most severe way possible: in perturbation theory about flat spacetime, at leading order in Newton's constant. The physical observables in a gravitational theory therefore do not organize themselves into local commuting subalgebras: the principle of locality must apparently be reformulated or abandoned, and in fact we lack a clear definition of the coarser and more basic notion of a quantum subsystem of the Universe. We discuss relational approaches to locality based on diffeomorphism-invariant nonlocal operators, and reinforce arguments that any such locality is state-dependent and approximate. Furthermore, we find limitations to the utility of bilocal diffeomorphism-invariant operators that are considered in cosmological contexts. An appendix provides a concise review of the canonical covariant formalism for gravity, instrumental in the discussion of Poincare charges and their associated long-range fields.

79 ASTRONOMY AND ASTROPHYSICS↗

The 12-layer trimer-based hexagonal perovskite Cs 4 Ca 0.7 Mn 3.3 Cl 12

Here, we describe the crystal structure and basic magnetic properties of Cs 4 Ca 0.7 Mn 3.3 Cl 12 , a previously unreported twelve layer (12L-) hexagonal (R-3m) chloride perovskite. Its crystal structure features face sharing MnCl 6 octahedra that form Mn 3 Cl 12 trimers. The trimers, which form a triangular array, are separated by corner sharing to layers of disordered single Ca(Mn)Cl 6 octahedra. The decreased intratrimer Mn–Mn distance yields stronger magnetic coupling within trimers than between trimers. The dominant magnetic interactions are antiferromagnetic (θ CW = –105 K), the effective magnetic moment per Mn 2+ is 6.5 μ B , and potential signatures of magnetic frustration are observed. Behavior consistent with short- and long-range magnetic order is exhibited at approximately 37 and 0.7 K, respectively.

12L-hexagonal perovskite↗

Structured light approaches in laser-based plasma diagnostics

There is a growing demand for plasma diagnostics suitable for industrial plasma reactors employed in semiconductor nanofabrication, especially relevant to microelectronics and quantum information systems. Such reactors typically have limited optical access and pose considerable diagnostic challenges, including intense background emission, significant thermal loads, and contamination of optical viewports. In this study, we outline research into structured light techniques (laser beams with tailored spatial, temporal, or phase characteristics) that effectively overcome these issues using laser-induced fluorescence (LIF) as an example. The focus of presented diagnostics is on ion kinetics analysis within an industrial plasma source, although this approach is broadly applicable to other plasma systems and diagnostic contexts. We present a confocal LIF implementation using an axicon-generated Bessel annular beam, achieving spatial resolutions of approximately 5 mm at a focal distance of 300 mm, with potential improvements to about 1 mm. This approach matches conventional orthogonal LIF performance but requires only one optical port. Wavelength-modulation LIF employs nonlinear laser wavelength tuning to measure spectral line derivatives, suppressing background emission and enhancing details of spectral line shape. Additionally, we present new results on applying vortex beams (laser beams carrying orbital angular momentum, OAM) for LIF measurements in an industrial plasma device. These measurements enable simultaneous axial and tangential velocity determination using a single laser beam and have been tested with xenon ion transition. Initial quantification of results was performed. Together, these structured-light approaches provide robust, background-resilient, multi-dimensional diagnostics for complex plasma environments.

Romadanov, Ivan [Princeton Plasma Physics Laborato↗

Exact Bayesian computation using H-functions

In the Bayesian Statistics, the use of conjugate prior distributions allows to obtain exact posterior quantities, avoiding the use of approximate methods. However, there are only a few conjugate structures available, which limits the use in practical problems. In this work we propose a general procedure to obtain the posterior distribution in an exact form in non-conjugate location parameter models with known (possibly, heteroskedastic) variance. The theory is based on special functions, specifically the H-function, which embraces most of the probability distributions. We express explicitly in a computable form all the Bayesian tools for posterior inferences, that is the posterior and the posterior predictive distributions and their moments, as well as the cumulative posterior distribution. As an illustration we consider a problem in astronomy of estimating the distance to the Large Magellanic Cloud, the largest galaxy now orbiting the Milky Way Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

An accurate and efficient laser-envelope solver for the modeling of laser-plasma accelerators

Detailed and reliable numerical modeling of laser-plasma accelerators (LPAs), where a short and intense laser pulse interacts with an underdense plasma over distances of up to a meter, is a formidably challenging task. This is due to the great disparity among the length scales involved in the modeling, ranging from the micron scale of the laser wavelength to the meter scale of the total laser-plasma interaction length. The use of the time-averaged ponderomotive force approximation, where the laser pulse is described by means of its envelope, enables efficient modeling of LPAs by removing the need to model the details of electron motion at the laser wavelength scale. Furthermore, it allows simulations in cylindrical geometry which captures relevant 3D physics at 2D computational cost. A key element of any code based on the time-averaged ponderomotive force approximation is the laser envelope solver. In this paper we present the accurate and efficient envelope solver used in the code INF & RNO (INtegrated Fluid & paRticle simulatioN cOde). The features of the INF & RNO laser solver enable an accurate description of the laser pulse evolution deep into depletion even at a reasonably low resolution, resulting in significant computational speed-ups.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LaBr 3 : Ce self-activation analysis for measuring fast neutron fields

Measurement of the fast neutron production rate in deuterium–tritium (D–T) fusion reactions is important for applications such as active interrogation, fusion diagnostics, and borehole logging. Such measurements are typically performed by neutron activation analysis of metal foils, especially copper. Copper foil activation analysis requires efficiency and energy calibrations of the detector used to measure the foil, and it relies on the detection of 511 keV gamma rays, which are prominent in the active background when neutrons are being produced. Alternatives, such as 79m Br produced by inelastic neutron scattering on 79 Br, are limited by short half-life, low-energy gamma emission, and inability to selectively measure D–T neutrons. This work describes a novel alternative approach to measure ≳10 MeV neutron fields based on self-activation analysis of a LaBr 3 :Ce detector. The activity of 78 Br, the activation product of the 79 Br(n,2n) 78 Br reaction, is used to determine the neutron flux and infer the neutron production rate. We experimentally demonstrate the method with a cylindrical LaBr 3 :Ce crystal with a diameter and height of 3.81 cm that was placed at an ~18 cm distance from the neutron production point, at a 90° angle with respect to the deuteron beam in a D–T neutron generator. Operating voltage and current of the generator were adjusted to evaluate the technique’s performance over a nominal generator output range of approximately (1 - 9) x 10 7 n/s. The neutron output obtained from LaBr 3 :Ce activation agrees to within three standard deviations of the output obtained using copper activation. The self-activation technique can be conveniently employed in a variety of applications to simplify measurements of fast neutrons produced in D–T fusion reactions.

Active interrogationLaBr3↗

The DES Bright Arcs Survey: Hundreds of Candidate Strongly Lensed Galaxy Systems from the Dark Energy Survey Science Verification and Year 1 Observations

We report the results of searches for strong gravitational lens systems in the Dark Energy Survey (DES) Science Verification and Year 1 observations. The Science Verification data span approximately 250 sq. deg. with a median i -band limiting magnitude for extended objects (10 σ ) of 23.0. The Year 1 data span approximately 2000 sq. deg. and have an i -band limiting magnitude for extended objects (10 σ ) of 22.9. As these data sets are both wide and deep, they are particularly useful for identifying strong gravitational lens candidates. Potential strong gravitational lens candidate systems were initially identified based on a color and magnitude selection in the DES object catalogs or because the system is at the location of a previously identified galaxy cluster. Cutout images of potential candidates were then visually scanned using an object viewer and numerically ranked according to whether or not we judged them to be likely strong gravitational lens systems. Having scanned nearly 400,000 cutouts, we present 374 candidate strong lens systems, of which 348 are identified for the first time. We provide the R.A. and decl., the magnitudes and photometric properties of the lens and source objects, and the distance (radius) of the source(s) from the lens center for each system.

79 ASTRONOMY AND ASTROPHYSICS↗

MO-F-CAMPUS-J-04: Tissue Segmentation-Based MR Electron Density Mapping Method for MR-Only Radiation Treatment Planning of Brain

Purpose: Automatically derive electron density of tissues using MR images and generate a pseudo-CT for MR-only treatment planning of brain tumours. Methods: 20 stereotactic radiosurgery (SRS) patients’ T1-weighted MR images and CT images were retrospectively acquired. First, a semi-automated tissue segmentation algorithm was developed to differentiate tissues with similar MR intensities and large differences in electron densities. The method started with approximately 12 slices of manually contoured spatial regions containing sinuses and airways, then air, bone, brain, cerebrospinal fluid (CSF) and eyes were automatically segmented using edge detection and anatomical information including location, shape, tissue uniformity and relative intensity distribution. Next, soft tissues - muscle and fat were segmented based on their relative intensity histogram. Finally, intensities of voxels in each segmented tissue were mapped into their electron density range to generate pseudo-CT by linearly fitting their relative intensity histograms. Co-registered CT was used as a ground truth. The bone segmentations of pseudo-CT were compared with those of co-registered CT obtained by using a 300HU threshold. The average distances between voxels on external edges of the skull of pseudo-CT and CT in three axial, coronal and sagittal slices with the largest width of skull were calculated. The mean absolute electron density (in Hounsfield unit) difference of voxels in each segmented tissues was calculated. Results: The average of distances between voxels on external skull from pseudo-CT and CT were 0.6±1.1mm (mean±1SD). The mean absolute electron density differences for bone, brain, CSF, muscle and fat are 78±114 HU, and 21±8 HU, 14±29 HU, 57±37 HU, and 31±63 HU, respectively. Conclusion: The semi-automated MR electron density mapping technique was developed using T1-weighted MR images. The generated pseudo-CT is comparable to that of CT in terms of anatomical position of tissues and similarity of electron density assignment. This method can allow MR-only treatment planning.

60 APPLIED LIFE SCIENCES↗

Characteristics of Vertical Ground Motions and Their Effect on the Seismic Response of Bridges in the Near-Field: A State-of-the-Art Review

Despite the evidence from past earthquakes and several numerical investigations demonstrating the detrimental impact of vertical ground motions (VGMs) on the integrity of bridge structures, incorporating their effects into seismic assessment and design procedures has traditionally been given limited consideration. Current codes utilize rather simplistic approaches to account for the concurrent effects of vertical and horizontal motions in structural performance evaluations, potentially leading to unconservative estimates of structural demands. This paper reviews the main features of VGMs and their effect on the seismic response of bridges. The methods and empirical models available to estimate vertical motions for design purposes are discussed, and research gaps and related research needs are identified. Finally, the emerging role of physics-based ground-motion simulations, as well as their limitations, in supporting future research and informing the development of simplified design procedures is examined. The main areas of interest for future research are identified in the need to carry out systematic sensitivity studies to gain insight into the main earthquake parameters that influence key VGMs features, understand the influence of soil nonlinearities on VGMs amplitude and frequency content, inform the development of empirical models that cover a range of site conditions and source-to-site distances where current models are poorly constrained, generate arrays of motions to update coherency models to properly inform the analysis of distributed infrastructure, investigate the impulsive character of VGMs, and assess the approximations made in estimating VGMs with 1D site response analyses. Furthermore, specific focus is laid on large-magnitude earthquakes in the near-field.

Asynchronous ground motion↗

TH-EF-207A-07: An Integrated X-Ray/bioluminescence Tomography System for Radiation Guidance and Tumor Evaluation

Purpose: CT is not able to differentiate tumors from surrounding soft tissue. This study is to develop a bioluminescence tomography (BLT) system that is integrated onto our previously developed CT guided small animal arc radiation treatment system (iSMAART) to guide radiation, monitor tumor growth and evaluate therapeutic response. Methods: The BLT system employs a CCD camera coupled with a high speed lens, and is aligned orthogonally to the x-ray beam central axis. The two imaging modalities, CT and BLT, are physically registered through geometrical calibration. The CT anatomy provides an accurate contour of animal surface which is used to construct 3D mesh for BLT reconstruction. Bioluminescence projections are captured from multiple angles, once every 45 degree rotation. The diffusion equation based on analytical Kirchhoff approximation is adopted to model the photon propagation in tissues. A discrete cosine transform based reweighted L1-norm regularization (DCT-re-L1) algorithm is used for BLT reconstruction. Experiments are conducted on a mouse orthotopic prostate tumor model (n=12) to evaluate the BLT performance, in terms of its robustness and accuracy in locating and quantifying the bioluminescent tumor cells. Iodinated contrast agent was injected intravenously to delineate the tumor in CT. The tumor location and volume obtained from CT also serve as a benchmark against BLT. Results: With our cutting edge reconstruction algorithm, BLT is able to accurately reconstruct the orthotopic prostate tumors. The tumor center of mass in BLT is within 0.5 mm radial distance of that in CT. The tumor volume in BLT is significantly correlated with that in CT (R2 = 0.81). Conclusion: The BLT can differentiate, localize and quantify tumors. Together with CT, BLT will provide precision radiation guidance and reliable treatment assessment in preclinical cancer research.

60 APPLIED LIFE SCIENCES↗

Mixing bispectrum multipoles under geometric distortions

We derive general expressions for how the Alcock–Paczynski distortions affect the power spectrum and the bispectrum of cosmological fields. We compute explicit formulas for the mixing coefficients of bispectrum multipoles in the linear approximation. The leading-order effect for the bispectrum is the uniform dilation of all three wavevectors. The mixing coefficients depend on the shape of the bispectrum triplet. Our results for the bispectrum multipoles are framed in terms of the ‘natural’ basis of the lengths of three wavevectors but can be easily generalized for other bases and reduction schemes. Our validation tests confirm that the linear approximation is extremely accurate for all power spectrum multipoles. The linear approximation is accurate for the bispectrum monopole but results in sub-per cent level inaccuracies for the bispectrum quadrupole and fails for the bispectrum hexadecapole. Our results can be used to simplify the analysis of the bispectrum from galaxy surveys, especially the measurement of the baryon acoustic oscillation peak position. They can be used to replace numeric schemes with exact analytical formulae.

79 ASTRONOMY AND ASTROPHYSICS↗

Increasing dose gradient and uniformity in small fields using modulation: Theory and prototypes for cone-based stereotactic radiosurgery

Purpose: To investigate the theoretical limits to the tradeoff between dose gradient and uniformity when modulation is used in the context of cone based SRS, and to design a prototype collimation device that allows for steeper dose gradients and/or higher target uniformity as compared to a standard circular collimator. Methods: An inverse planning optimization is performed in the context of idealized phantom geometry to determine the ideal fluence pattern that best approximates a “rect function” dose distribution. Ideal fluence patterns were approximated in a prototype device and radiochromic film dosimetry was utilized to compare the prototype device to a standard circular collimator. Results: For choices of prescription isodose lines above approximately 50%, utilizing modulation allows for an improved tradeoff between dose gradient index and dose heterogeneity index. Compensators placed within the circular collimator can achieve the necessary modulation. Conclusions: Using modulation with features on a submillimeter distance scale, it is possible to increase the dose gradient and/or uniformity in small fields.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling and Calibration of Supplier Selection Problem in Freight Agent-Based Simulations

Freight transportation modeling often struggles with data limitations, especially in accurately representing complex supplier selection processes and their impact on network flows. This research addresses this critical gap by developing a large-scale, calibrated agent-based model for supplier selection, complemented by a probabilistic heuristic for international shipments. Our approach integrates trade relationships between industry sectors, transportation costs, and a supplier-rating model adapted from existing literature. The model’s core objective is to minimize the discrepancy between modeled and observed commodity flows while ensuring a close match to regional shipping distance distributions. Implemented and tested across four major U.S. metropolitan areas—Atlanta, Chicago, Dallas–Fort Worth, and Los Angeles—the model demonstrates high fidelity in replicating observed freight patterns. Key findings reveal consistent alignment with national shipping distance trends and highlight significant spatial variations in commodity trade assignments and demand across the study regions. This behaviorally informed and transport-sensitive framework is designed to approximate real-world decision making, providing a robust tool for policymakers and planners to evaluate targeted interventions, assess infrastructure investments, and enhance supply chain resilience in the face of disruptions.

Ismael, Abdelrahman (ORCID:0000000303712110)↗

Effects of ray profile modeling on resolution recovery in clinical CT

Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. However, among vendors and researchers, there is no consensus of how to best achieve these goals. The authors are focusing on the aspect of geometric ray profile modeling, which is realized by some algorithms, while others model the ray as a straight line. The authors incorporate ray-modeling (RM) in nonregularized iterative reconstruction. That means, instead of using one simple single needle beam to represent the x-ray, the authors evaluate the double integral of attenuation path length over the finite source distribution and the finite detector element size in the numerical forward projection. Our investigations aim at analyzing the resolution recovery (RR) effects of RM. Resolution recovery means that frequencies can be recovered beyond the resolution limit of the imaging system. In order to evaluate, whether clinical CT images can benefit from modeling the geometrical properties of each x-ray, the authors performed a 2D simulation study of a clinical CT fan-beam geometry that includes the precise modeling of these geometrical properties. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and a Forbild thorax phantom with circular resolution patterns representing calcifications in the heart region are simulated. An FBP reconstruction with a Ram–Lak kernel is used as a reference reconstruction. The FBP is compared to iterative reconstruction techniques with and without RM: An ordered subsets convex (OSC) algorithm without any RM (OSC), an OSC where the forward projection is modeled concerning the finite focal spot and detector size (OSC-RM) and an OSC with RM and with a matched forward and backprojection pair (OSC-T-RM, T for transpose). In all cases, noise was matched to be able to focus on comparing spatial resolution. The authors use two different simulation settings. Both are based on the geometry of a typical clinical CT system (0.7 mm detector element size at isocenter, 1024 projections per rotation). Setting one has an exaggerated source width of 5.0 mm. Setting two has a realistically small source width of 0.5 mm. The authors also investigate the transition from setting one to two. To quantify image quality, the authors analyze line profiles through the resolution patterns to define a contrast factor (CF) for contrast-resolution plots, and the authors compare the normalized cross-correlation (NCC) with respect to the ground truth of the circular resolution patterns. To independently analyze whether RM is of advantage, the authors implemented several iterative reconstruction algorithms: The statistical iterative reconstruction algorithm OSC, the ordered subsets simultaneous algebraic reconstruction technique (OSSART) and another statistical iterative reconstruction algorithm, denoted with ordered subsets maximum likelihood (OSML) algorithm. All algorithms were implemented both without RM (denoted as OSC, OSSART, and OSML) and with RM (denoted as OSC-RM, OSSART-RM, and OSML-RM). Results: For the unrealistic case of a 5.0 mm focal spot the CF can be improved by a factor of two due to RM: the 4.2 LP/cm bar pattern, which is the first bar pattern that cannot be resolved without RM, can be easily resolved with RM. For the realistic case of a 0.5 mm focus, all results show approximately the same CF. The NCC shows no significant dependency on RM when the source width is smaller than 2.0 mm (as in clinical CT). From 2.0 mm to 5.0 mm focal spot size increasing improvements can be observed with RM. Conclusions: Geometric RM in iterative reconstruction helps improving spatial resolution, if the ray cross-section is significantly larger than the ray sampling distance. In clinical CT, however, the ray is not much thicker than the distance between neighboring ray centers, as the focal spot size is small and detector crosstalk is negligible, due to reflective coatings between detector elements. Therefore,RM appears not to be necessary in clinical CT to achieve resolution recovery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reliability modeling in a predictive maintenance context: A margin-based approach

Current system reliability methods (typically based on fault trees or reliability block diagrams) can effectively propagate reliability data from the asset to the system level in order to identify system critical points. However, employed asset reliability data are an approximated integral representation of the past industrywide operational experience, and they neglect the present asset health status (available, for example, from online monitoring data and diagnostic assessments) and forecasted health projection (when available from prognostic models). Asset health should be informed solely by that specific asset’s current and historical performance data and should not be an approximated integral representation of the past industrywide operational experience (as currently performed by system reliability models through Bayesian updating processes). Sensor data, diagnostic assessments, and prognostic assessments are in fact not considered in plant reliability models used to inform system engineers on the most critical assets. In addition, the propagation of quantitative health data from the asset to the system level is a challenge given the diverse nature and structure of health data elements (e.g., vibration spectra, temperature readings, expected failure time). Ideally, in a predictive maintenance context, system reliability models should support decision making by propagating available health information from the asset to the system level in order to provide a quantitative snapshot of system health and identify the most critical assets. Here, this paper is directly addressing these two goals by proposing a different approach for reliability modeling that relies on asset diagnostic and prognostic assessments, along with monitoring data to measure asset health. The propagation of health data from the asset to the system level is performed through fault tree models not in probability terms, but in terms of margin where margin is the “distance” between the present status and an undesired event (e.g., failure or unacceptable performance). Through a cause-effect lens, while classical reliability models target the effect associated with asset performance, a margin-based approach focuses on the cause of an undesired asset performance (i.e., its health). Hence, thinking of reliability in terms of margins implies decision-making based on causal reasoning. We will show how fault tree models can be solved using a margin language and how this process can effectively assist system engineers to identify the most critical assets.

97 - MATHEMATICS AND COMPUTING↗

Feasibility of an experiment on clumping induced by the Crow instability along a shocked cylinder

The growth of three-dimensional perturbations subject to the Crow instability along a vortex dipole resulting from the passage of a shock wave through a heavy gaseous cylinder is examined numerically. A linear stability analysis is performed based on geometric parameters extracted from two-dimensional simulations to determine the range of unstable wavenumbers, which is found to extend from 0.0 to 1.3 when normalized by the core separation distance. The analysis is then verified by comparison to three-dimensional simulations, which clearly show the development of the instability and the pinch-off of the vortex dipole into isolated vortex rings, which manifest as clumps of the original cylinder material. A scaling law is developed to determine the relevant spatiotemporal scales of the instability development, which is then used to assess the feasibility of a high-energy-density experiment visualizing clump formation. Specifically, a shocked cylinder with an initial diameter of 100 μm consisting of a perturbation of approximate wavelength and amplitude of 600 and 10 μm, respectively, is expected to form clumps resulting from the Crow instability approximately 40 ns after it is shocked, with dynamics which can be readily visualized on the Omega EP laser facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗