Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distance measure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Concept Design of Active Shielding for Dynamic Wireless Charging of Light-duty EV

Dynamic wireless charging of electric vehicles is a flexible and state of the art charging technology with the potential capability of enabling fully automated in-motion charging. With charging power increasing to more than 100 kW for light duty vehicles, electromagnetic field (EMF) emission becomes a critical challenge. Due to the high costs of ferrite materials, this paper proposes an active shielding solution with multiple canceling coils installed on the ground side to supplement ferrite passive shielding to ensure electromagnetic safety. Two canceling coils are designed on two sides of the ground side coil. The canceling coils are small in size and 180 degree opposite in phase to the ground coil. Simulation and modeling shows that the canceling coils can reduce EMF emission from 37.2 µT to 18.2 µT at 0.8 m during 100 kW operation with only 2.5% of ground side current flowing in the canceling coils. These results have been preliminarily verified by inductance measurements and magnetic field measurement at 1.1 m distance without canceling coils. By further increasing the canceling coils’ currents to 4%, EMF emission can also be mitigated at 200 kW, although the canceling coils’ shape, position, and phase angle can be further optimized to improve the three-dimensional field distribution.

25 ENERGY STORAGE↗

Powertrain control system and method of operating the same

A system and method are provided for operating a powertrain control system. The method includes receiving data measured from a plurality of sensors, the measured data relating to distance dependent speed values, and receiving information from one or more vehicle modules, the vehicle module information relating to distance independent speed values. The method further includes building a speed trajectory profile for a horizon window that includes a plurality of speed change regions represented by at least some distance dependent speed values or at least some distance independent speed values, and creating a synthesized speed profile for the horizon window by processing the speed trajectory profile. The synthesized speed profile optimizes efficiency of the powertrain control system at each of the plurality of speed change regions.

33 ADVANCED PROPULSION SYSTEMS↗

Novel Preprocessing Techniques for Enhancing Flowability of Miscanthus

Purpose-grown energy crops possess significant potential as promising feedstocks for biofuel and biochemical production. However, similar to other biomass feedstocks, their utilization has been hindered by handling and feeding challenges such as clogging and segregation, which prevent biorefineries from operating at full capacity. These challenges arise primarily due to particle attributes including irregular shape, high flexibility, and high compressibility, leading to interlocking, high compaction, and significant friction under stress consolidation. To enhance operational reliability, it is crucial to focus on preprocessing techniques to address these issues, alongside accurately characterizing the mechanical and physical properties and flow performance of these feedstocks. This study investigates novel preprocessing techniques, including pelletization and torrefaction, to fundamentally alter these particle attributes and improve flowability. Miscanthus, an herbaceous energy crop, was the primary focus of this study. Samples were processed using a Forest Concepts Crumbler rotary shear system and an oscillating multi-stack screen bed to achieve two nominal (baseline) particle sizes: 6mm and 2mm. The study evaluated the efficiency and energy consumption of size reduction, revealing that while 2mm particles required more energy, they exhibited better flowability and higher yield strength compared to 6mm particles. Shear and compression tests assessed the material's shear strength, internal friction, and elastic modulus, while wedge-shaped hopper tests measured the critical arching distance and mass flow rate. The results provide valuable insights into the mechanical properties and processing efficiency of Miscanthus, contributing to the development of a preprocessing framework that enhances energy efficiency and material flowability in bioenergy production. However, further preprocessing and development are required to optimize this framework fully.

09 - BIOMASS FUELS↗

Toward Human-Centric Transportation and Energy Metrics: Influence of Mode, Vehicle Occupancy, Trip Distance, and Fuel Economy

Traditional metrics measuring transportation and energy outcomes can be augmented to better represent impacts on people's lives and systems-level performance. In this context, this study introduces two novel metrics: road capacity (as number of people traveling and accessing services) and energy intensity (as energy use for people traveling and accessing services). Current national-level distributions of available data in the United States for factors contributing to the two new integrated metrics are used as context to evaluate potential outcomes. These factors include vehicle occupancy, mode share, fuel economy, and trip distance. Variations in input values provide insights on how these factors shape efficiencies in road capacity and energy intensity. Parametric sensitivity analysis indicates that the impact of each input depends upon the metric being evaluated. For the human-centered road capacity mobility metric, increasing vehicle occupancy has the largest effect – twice that of increasing mode share for bike, walk, and transit. For the energy intensity mobility metric, the effect of improving fuel economy is the largest. However, when the focus is on accessibility (instead of mobility), for both metrics the effect of lowering average trip distance is the largest. Additionally, a novel interactive tool to visualize the results for various parameter combinations makes the metrics practitioner ready. The findings suggest that the diffusion of new human-centric metrics that benchmark outcomes associated with road capacity and energy may be significant in motivating new sustainable transportation investments and efficient utilization of infrastructure, mobility assets, and services.

ADVANCED PROPULSION SYSTEMS↗

Asteroids for μ Hz gravitational-wave detection

A major challenge for gravitational-wave (GW) detection in the μHz band is engineering a test mass (TM) with sufficiently low acceleration noise. We propose a GW detection concept using asteroids located in the inner Solar System as TMs. Our main purpose is to evaluate the acceleration noise of asteroids in the μHz band. We show that a wide variety of environmental perturbations are small enough to enable an appropriate class of ~10 km-diameter asteroids to be employed as TMs. This would allow a sensitive GW detector in the band (few) × 10 -7 Hz ≲ fGW ≲ (few) × 10 -5 Hz, reaching strain hc ~ 10 -19 around f GW ~10 μHz, sufficient to detect a wide variety of sources. To exploit these asteroid TMs, human-engineered base stations could be deployed on multiple asteroids, each equipped with an electromagnetic transmitter/receiver to permit measurement of variations in the distance between them. We discuss a potential conceptual design with two base stations, each with a space-qualified optical atomic clock measuring the round-trip electromagnetic pulse travel time via laser ranging. Trade space exists to optimize multiple aspects of this mission: for example, using a radio-ranging or interferometric link system instead of laser ranging. This motivates future dedicated technical design study. This mission concept holds exceptional promise for accessing this GW frequency band.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A dark siren measurement of the Hubble constant using gravitational wave events from the first three LIGO/Virgo observing runs and DELVE

The current and next observation seasons will detect hundreds of gravitational waves (GWs) from compact binary systems coalescence at cosmological distances. When combined with independent electromagnetic measurements, the source redshift will be known, and we will be able to obtain precise measurements of the Hubble constant H_0 via the distance–redshift relation. However, most observed mergers are not expected to have electromagnetic counterparts, which prevents a direct redshift measurement. In this scenario, one possibility is to use the dark sirens method that statistically marginalizes over all the potential host galaxies within the GW location volume to provide a probabilistic source redshift. Here we presented H_0 measurements using two new dark sirens compared to previous analyses using DECam data: GW190924|$\_$|021846 and GW200202|$\_$|154313. The photometric redshifts of the possible host galaxies of these two events are acquired from the DECam Local Volume Exploration Survey (DELVE) carried out on the Blanco telescope at Cerro Tololo. The combination of the H_0 posterior from GW190924|$\_$|021846 and GW200202|$\_$|154313 together with the bright siren GW170817 leads to |$H_{0} = 68.84^{+15.51}_{-7.74}\, \rm {km\, s^{-1}\, Mpc^{-1}}$|⁠. Including these two dark sirens improves the 68 per cent confidence interval (CI) by 7 per cent over GW170817 alone. This demonstrates that the addition of well-localized dark sirens in such analysis improves the precision of cosmological measurements. Using a sample containing 10 well-localized dark sirens observed during the third LIGO/Virgo observation run, without the inclusion of GW170817, we determine a measurement of |$H_{0} = 76.00^{+17.64}_{-13.45}\, \rm {km\, s^{-1}\, Mpc^{-1}}$|⁠.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing the Environment around GW170817 with DESI: Insights on Galaxy Group Peculiar Velocities for Standard Siren Measurements

We present a new measurement of the Hubble constant, H 0 , following the gravitational-wave event GW170817 and Dark Energy Spectroscopic Instrument (DESI) observations. A standard siren measurement with a nearby (luminosity distance ∼40 Mpc) event such as GW170817 is typically sensitive to the peculiar motion of the host galaxy owing to local dynamics. Previous measurements from this event have taken advantage of peculiar velocity measurements of nearby galaxies, including a handful of objects in the galaxy group that the host of the event, NGC 4993, has been associated with. Still, the group’s properties and NGC 4993’s membership were debated. We present DESI observations of thousands of galaxies in the vicinity of NGC 4993, resulting in 39 group galaxies and a fivefold increase in galaxies compared to previous observations, with many contributing to a peculiar velocity measurement. Examining the local dynamics, our observations support the presence of a galaxy group of which NGC 4993 is a part with a halo mass of order ∼10 13 M ⊙ . Using peculiar velocity measurements from our fundamental plane galaxy observations, we find $H_0 = 70.9^{+6.4}_{-8.5}$ km s −1 Mpc −1 . In addition, using a peculiar velocity measurement for NGC 4993 from surface brightness fluctuations in Cosmicflows-4, we find $H_0 = 73.4^{+3.3}_{-3.9}$ km s −1 Mpc −1 . We study the impact of different galaxy selection criteria on the determination of the peculiar velocity and, in turn, on the H 0 measurement. Our results demonstrate the value of multiplexed spectroscopic observations for probing the local environments of gravitational-wave events used in standard siren measurements.

Amsellem, A. J. [Carnegie Mellon University, Pitts↗

Special Nuclear Material Hold-up Measurement

Facilities that process special nuclear material (SNM) generally have a variety of equipment, shielding, and nearby radiation sources, which can pose challenges when performing nondestructive analysis (NDA) within the facility, as shown in Figure 1. In this figure, the left image features two individuals performing a holdup measurement of a large duct at a posting, utilizing a detector probe attached to a yardstick to reduce some aspect of the measurement uncertainty. Note that the distance to the holdup within the pipe from the posting cannot be accounted for. The right image similarly features several individuals guiding a holdup measurement of a ducting pipe several meters overhead, by attaching a detector probe to a long handle and lining that up with a posting on the outside of the pipe. SNM processing begets SNM holdup, and this difficulty with accurate NDA can result in unaccounted accumulation of SNM holdup within a process or area. Normal SNM processing operations can accumulate holdup within filters, pumps, pipes, ducts, other equipment, and facility support systems, as demonstrated by Figure 2. It is important for deactivation and decommissioning (D&D) gloveboxes and their ancillary equipment, material accountability, criticality safety, facility operations, waste management, radiation safety, and security to accurately characterize the location, composition, and quantity of this holdup to minimize these associated risks and potential diversion pathways. Current NDA techniques for assay of holdup are expensive, time consuming, and have high uncertainty.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measuring Transverse Displacements Using Unmanned Aerial Systems Laser Doppler Vibrometer (UAS-LDV): Development and Field Validation

Measurement of bridge displacements is important for ensuring the safe operation of railway bridges. Traditionally, contact sensors such as Linear Variable Displacement Transducers (LVDT) and accelerometers have been used to measure the displacement of the railway bridges. However, these sensors need significant effort in installation and maintenance. Therefore, railroad management agencies are interested in new means to measure bridge displacements. This research focuses on mounting Laser Doppler Vibrometer (LDV) on an Unmanned Aerial System (UAS) to enable contact-free transverse dynamic displacement of railroad bridges. Researchers conducted three field tests by flying the Unmanned Aerial Systems Laser Doppler Vibrometer (UAS-LDV) 1.5 m away from the ground and measured the displacement of a moving target at various distances. The accuracy of the UAS-LDV measurements was compared to the Linear Variable Differential Transducer (LVDT) measurements. The results of the three field tests showed that the proposed system could measure non-contact, reference-free dynamic displacement with an average peak and root mean square (RMS) error for the three experiments of 10% and 8% compared to LVDT, respectively. Such errors are acceptable for field measurements in railroads, as the interest prior to bridge monitoring implementation of a new approach is to demonstrate similar success for different flights, as reported in the three results. This study also identified barriers for industrial adoption of this technology and proposed operational development practices for both technical and cost-effective implementation.

42 ENGINEERING↗

Evaluating generative networks using Gaussian mixtures of image features

We develop a measure for evaluating the performance of generative networks given two sets of images. A popular performance measure currently used to do this is the Fréchet Inception Distance (FID). However, FID assumes that images featurized using the penultimate layer of Inception follow a Gaussian distribution. This assumption allows FID to be easily computed, since FID uses the 2-Wasserstein distance of two Gaussian distributions fitted to the featurized images. However, we show that Inception features of the ImageNet dataset are not Gaussian; in particular, each marginal is not Gaussian. To remedy this problem, we model the featurized images using Gaussian mixture models (GMMs) and compute the 2-Wasserstein distance restricted to GMMs. We define a performance measure, which we call WaM, on two sets of images by using inception (or another classifier) to featurize the images, estimate two GMMs, and use the restricted 2-Wasserstein distance to compare the GMMs. We experimentally show the advantages of WaM over FID, including how FID is more sensitive than WaM to image perturbations. By modelling the non-Gaussian features obtained from inception as GMMs and using a GMM metric, we can more accurately evaluate generative network performance.

machine learning, genrative adversarial networks↗

Prediction of a measurable sign change in the Casimir force using a magnetic fluid

Here, we demonstrate quantum levitation controlled by Casimir forces acting between a polystyrene surface and a Teflon-coated metallic substrate immersed in a mixture of toluene and magnetite particles. This system experiences repulsion-attraction transitions in the Casimir interaction for distances where the effect is measurable. This Casimir trapping can be controlled by clever choices of metallic and ferrofluid materials, which are directly linked to the emergence of the trapping effect. Thermal and quantum contributions are investigated in detail, showing how the optical and magnetic properties of the ferrofluid and other materials affect the magnitude of the trapping and its distance range of observability.

Ma, Long [University of South Florida, Tampa, FL (↗

New Method for the Astrometric Direct Detection of Ultralight Dark Matter

Ultralight dark matter induces time-dependent perturbations in the spacetime metric, enabling its . In this Letter, we propose using astrometry to detect dark matter. After reviewing the calculation of the metric in the presence of scalar dark matter, we study the influence of the perturbations on the apparent motion of astrophysical bodies. We apply our results to angular position measurements of quasars, whose vast distances from Earth present an opportunity to discover subcomponent dark matter with a mass as low as 10 − 33 eV . We explore the prospects of very long baseline interferometry and optical astrometric survey measurements for detecting ultralight relics, finding that for the smallest masses, current astrometric surveys can detect dark matter moving locally with a velocity of 10 − 3 with energy density as low as 3 × 10 − 11 GeV / cm 3 . Published by the American Physical Society 2025

Dror, Jeff A. (ORCID:0000000301106184)↗

Regression Convolutional Neural Network for Energy Estimation in NOvA

Regression Convolutional Neural Network for Energy Estimation in NOvA" Abstract: "NOvA (NuMI Off-Axis $\nu_e$ Appearance) is a long baseline neutrino experiment designed to measure neutrino oscillations over a distance of 810 km. NOvA employs a near and far detector to observe $\nu_\mu$ disappearance and $\nu_e$ appearance of neutrinos produced by the NuMI beam at Fermilab. Energy reconstruction is critical for precise measurements of neutrino oscillation parameters and cross sections, which are functions of neutrino energy. Energy estimation remains difficult due to the complexity of detector response and final state particle kinematics. We present a regression-based convolutional neural network (CNN) method that reconstructs neutrino and lepton energies based on raw pixel inputs for NOvA. The trained model is able to reconstruct event energy for different interaction modes and complex final states containing leptons and hadrons. Studies of regression CNN networks show improved energy resolution and reduced sensitivity to calibration scale uncertainties relative to traditional kinematics-based energy reconstruction techniques. The results demonstrate the potential of the regression CNN method for neutrino physics analyses by improving on standard kinematics-based reconstruction.

Zhao, Larry [UC, Irvine (main)]↗

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN↗

Measurement of atomic oxygen densities using TALIF on a dielectric barrier discharge: insights into the volume above a micro cavity plasma array

Dielectric barrier discharges, particularly micro cavity plasma arrays, offer significant potential for plasma-catalytic research due to their ability to ignite plasma in direct contact with a catalytic surface, enabling the observation of plasma-surface interactions. A key factor in their application is the generation of reactive species, such as atomic oxygen, within the cavities. These species can interact with both the surface (e.g. for activation or cleaning) and the gas being treated (e.g. for oxidation). Given the central role of oxygen atoms in plasma catalysis and their use as a model for more complex species, this work investigates the transport of these atoms out of the cavities. Two-photon absorption laser-induced fluorescence spectroscopy with picosecond laser excitation is performed in the volume above the cavities. The results are compared with a basic diffusion model. The reactor operates with a He/O 2 mixture at a flow rate of 1 slm and atmospheric pressure. Densities of up to 10 16 cm -3 are measured near the surface. Time-dependent measurements show that, at a distance of 350 µm from the surface, a density equilibrium is reached within less than 3 ms of reactor operation. Decay times due to ozone formation after the reactor is turned off are on a similar scale. Spatially resolved measurements show that the oxygen density decreases exponentially from the surface but remains detectable up to approximately 1 mm above the surface, indicating significant application potential. Variations in the O 2 admixture show a density maximum at 0.4%, confirming previous helium state enhanced actinometry measurements within the cavities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DESI 2024 VI: cosmological constraints from the measurements of baryon acoustic oscillations

We present cosmological results from the measurement of baryon acoustic oscillations (BAO) in galaxy, quasar and Lyman-α forest tracers from the first year of observations from the Dark Energy Spectroscopic Instrument (DESI), to be released in the DESI Data Release 1. DESI BAO provide robust measurements of the transverse comoving distance and Hubble rate, or their combination, relative to the sound horizon, in seven redshift bins from over 6 million extragalactic objects in the redshift range 0.1 < z < 4.2. To mitigate confirmation bias, a blind analysis was implemented to measure the BAO scales. DESI BAO data alone are consistent with the standard flat ΛCDM cosmological model with a matter density Ω m =0.295±0.015. Paired with a baryon density prior from Big Bang Nucleosynthesis and the robustly measured acoustic angular scale from the cosmic microwave background (CMB), DESI requires H 0 =(68.52±0.62) km s -1 Mpc -1 . In conjunction with CMB anisotropies from Planck and CMB lensing data from Planck and ACT, we find Ω m =0.307± 0.005 and H 0 =(67.97±0.38) km s -1 Mpc -1 . Extending the baseline model with a constant dark energy equation of state parameter w, DESI BAO alone requirew=-0.99 +0.15 -0.13 . In models with a time-varying dark energy equation of state parametrised by w 0 and w a , combinations of DESI with CMB or with type Ia supernovae (SN Ia) individually prefer w 0 > -1 and w a < 0. This preference is 2.6σ for the DESI+CMB combination, and persists or grows when SN Ia are added in, giving results discrepant with the ΛCDM model at the 2.5σ, 3.5σ or 3.9σ levels for the addition of the Pantheon+, Union3, or DES-SN5YR supernova datasets respectively. For the flat ΛCDM model with the sum of neutrino mass ∑ m ν free, combining the DESI and CMB data yields an upper limit ∑ m ν < 0.072 (0.113) eV at 95% confidence for a ∑ m ν > 0 (∑ m ν > 0.059) eV prior. These neutrino-mass constraints are substantially relaxed if the background dynamics are allowed to deviate from flat ΛCDM.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-parameter distributed fiber optic sensing using double-Brillouin peak fiber in Brillouin optical time domain analysis

In this paper, we demonstrate a multi-parameter fiber sensing system based on stimulated Brillouin scattering in a double-Brillouin peak specialty fiber with enhanced Brillouin gain response. The amplitude level of the second Brillouin gain peak, which originated from the higher-order acoustic modes, has been improved with an approximately similar amplitude level to the first Brillouin gain peak from the fundamental acoustic mode. Compared to other multi-Brillouin peak fibers presented in the literature, the proposed fiber significantly reduces the measured Brillouin frequency shift error, thus improving strain and temperature accuracies. By utilizing the sensitivity values of the strain and temperature associated with each Brillouin gain spectrum (BGS) peak, a successful discriminative measurement of strain and temperature is performed with an accuracy of ±13 μɛ, and ±0.5 °C, respectively. The proposed double-Brillouin peak fiber appears to be a possible alternative to other multi-BGS peak fibers, for instance, large effective area fiber and dispersion compensating fibers, which are inherently accompanied by large measurement errors due to the weak Brillouin gain values originating from the higher-order acoustic modes. The demonstrated results show different strain and temperature coefficients of 47 kHz/µɛ, 1.15 MHz/°C for peak 1 and 51 kHz/µɛ, 1.37 MHz/°C for peak 2. Moreover, the enhanced BGS peak gains having nearly the same amplitude levels enable the discriminative measurement of strain and temperature. Such fibers in Brillouin interrogation eliminate the need for complex monitoring setups and reduce measurement errors. We recommend that for long-distance natural gas pipeline monitoring, where discriminative strain and temperature measurement is crucial, the proposed double-Brillouin peak fiber can be highly beneficial.

47 OTHER INSTRUMENTATION↗

Triaxiality in the mid-shell nucleus 112 Pd

In this work, lifetimes of low-spin excited states in 112 Pd were measured using the recoil-distance Doppler-shift technique. The nucleus of interest was populated in a 110 Pd( 18 O, 16 O) 112 Pd reaction using the Cologne FN Tandem accelerator. Three lifetimes of ground-state band members and one lifetime of the γ band were measured. From these lifetimes reduced transition probabilities were extracted and compared to interacting boson model, γ-soft calculations, and Davydov calculations. The lifetime of the $2_{γ}^{+}$ gives some insights on the nuclear shape and structure of the γ band. The deduced transition rates show an indicator for a rigid triaxial nucleus as well as more indicators for a γ-soft nucleus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗