Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distortion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Numerical Modeling of Flow Control in a Boundary-Layer-Ingesting Offset Inlet Diffuser at Transonic Mach Numbers

This paper will investigate the validation of the NASA developed, Reynolds-averaged Navier-Stokes (RANS) flow solver, OVERFLOW, for a boundary-layer-ingesting (BLI) offset (S-shaped) inlet in transonic flow with passive and active flow control devices as well as a baseline case. Numerical simulations are compared to wind tunnel results of a BLI inlet experiment conducted at the NASA Langley 0.3-Meter Transonic Cryogenic Tunnel. Comparisons of inlet flow distortion, pressure recovery, and inlet wall pressures are performed. The numerical simulations are compared to the BLI inlet data at a free-stream Mach number of 0.85 and a Reynolds number of approximately 2 million based on the fanface diameter. The numerical simulations with and without tunnel walls are performed, quantifying tunnel wall effects on the BLI inlet flow. A comparison is made between the numerical simulations and the BLI inlet experiment for the baseline and VG vane cases at various inlet mass flow rates. A comparison is also made to a BLI inlet jet configuration for varying actuator mass flow rates at a fixed inlet mass flow rate. Overall, the numerical simulations were able to predict the baseline circumferential flow distortion, DPCP avg, very well within the designed operating range of the BLI inlet. A comparison of the average total pressure recovery showed that the simulations were able to predict the trends but had a negative 0.01 offset when compared to the experimental levels. Numerical simulations of the baseline inlet flow also showed good agreement with the experimental inlet centerline surface pressures. The vane case showed that the CFD predicted the correct trends in the circumferential distortion levels for varying inlet mass flow but had a distortion level that was nearly twice as large as the experiment. Comparison to circumferential distortion measurements for a 15 deg clocked 40 probe rake indicated that the circumferential distortion levels are very sensitive to the symmetry of the flow and that a misalignment of the vanes in the experiment could have resulted in this difference. The numerical simulations of the BLI inlet with jets showed good agreement with the circumferential inlet distortion levels for a range of jet actuator mass flow ratios at a fixed inlet mass flow rate. The CFD simulations for the jet case also predicted an average total pressure recovery offset that was 0.01 lower than the experiment as was seen in the baseline. Comparisons of the flow features for the jet cases revealed that the CFD predicted a much larger vortex at the engine fan-face when compare to the experiment.

Allan, Brian G.↗

Reducing Ground-based Astrometric Errors with Gaia and Gaussian Processes

Stochastic field distortions caused by atmospheric turbulence are a fundamental limitation to the astrometric accuracy of ground-based imaging. This distortion field is measurable at the locations of stars with accurate positions provided by the Gaia DR2 catalog; we develop the use of Gaussian process regression (GPR) to interpolate the distortion field to arbitrary locations in each exposure. We introduce an extension to standard GPR techniques that exploits the knowledge that the 2D distortion field is curl-free. Applied to several hundred 90 s exposures from the Dark Energy Survey as a test bed, we find that the GPR correction reduces the variance of the turbulent astrometric distortions ≈12× , on average, with better performance in denser regions of the Gaia catalog. The rms per-coordinate distortion in the riz bands is typically ≈7 mas before any correction and ≈2 mas after application of the GPR model. The GPR astrometric corrections are validated by the observation that their use reduces, from 10 to 5 mas rms, the residuals to an orbit fit to riz-band observations over 5 yr of the r = 18.5 trans-Neptunian object Eris. We also propose a GPR method, not yet implemented, for simultaneously estimating the turbulence fields and the 5D stellar solutions in a stack of overlapping exposures, which should yield further turbulence reductions in future deep surveys.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The reduction of the National Aeronautics and Space Administration plates at the New Mexico University

A method of reducing GEOS satellite plates is described. The catalog positions of stars, whose images were measured, are updated to the time of the photographic observation. The plate constants are used to compute the positions of the seven (or fewer) flashing light images which were measured. There are corrected for refraction, parallax, and radial and decentering lens distortions. With sidereally tracking cameras, the exterior orientation is further corrected to the time of the particular flash, and the change of refraction with time is allowed for. First and second differences and standard deviations and covariances for the flashing light images are developed as a measure of accuracy.

Haas, W. H.↗

Processing Near-Infrared Imagery of the Orion Heatshield During EFT-1 Hypersonic Reentry

The Scientifically Calibrated In-Flight Imagery (SCIFLI) team captured high-resolution, calibrated, near-infrared imagery of the Orion capsule during atmospheric reentry of the EFT-1 mission. A US Navy NP-3D aircraft equipped with a multi-band optical sensor package, referred to as Cast Glance, acquired imagery of the Orion capsule's heatshield during a period when Orion was slowing from approximately Mach 10 to Mach 7. The line-of-sight distance ranged from approximately 65 to 40 nmi. Global surface temperatures of the capsule's thermal heatshield derived from the near-infrared intensity measurements complemented the in-depth (embedded) thermocouple measurements. Moreover, these derived surface temperatures are essential to the assessment of the thermocouples' reliance on inverse heat transfer methods and material response codes to infer the surface temperature from the in-depth measurements. The paper describes the image processing challenges associated with a manually-tracked, high-angular rate air-to-air observation. Issues included management of significant frame-to-frame motions due to both tracking jerk and jitter as well as distortions due to atmospheric effects. Corrections for changing sky backgrounds (including some cirrus clouds), atmospheric attenuation, and target orientations and ranges also had to be made. The image processing goal is to reduce the detrimental effects due to motion (both sensor and capsule), vibration (jitter), and atmospherics for image quality improvement, without compromising the quantitative integrity of the data, especially local intensity (temperature) variations. The paper will detail the approach of selecting and utilizing only the highest quality images, registering several co-temporal image frames to a single image frame to the extent frame-to-frame distortions would allow, and then co-adding the registered frames to improve image quality and reduce noise. Using preflight calibration data, the registered and averaged infrared intensity images were converted to surface temperatures on the Orion capsule's heatshield. Temperature uncertainties will be discussed relative to uncertainties of surface emissivity and atmospheric transmission loss. Comparison of limited onboard surface thermocouple data to the image derived surface temperature will be presented.

Spisz, Thomas S.↗

Reduction of intensity variations on a photovoltaic array with compound parabolic concentrators

The reduction of nonuniformities in the intensity distribution of light focused on a photovoltaic array by a compound parabolic concentrator is investigated. The introduction of small distortions into the surfaces of the reflector in order to diffuse the incident collimated light to fill the angular acceptance of the concentrator is calculated by means of ray tracing to decrease the irradiance nonuniformity at the cost of a lowered effective concentration of the concentrator. Measurements of the intensity distribution on a scale test model in terrestrial sunlight with corrugated aluminized mylar reflectors are shown to be in good agreement with the ray tracing results. A two-stage concentrator consisting of a focusing primary and a nonimaging secondary is also shown to result in a fairly uniform intensity distribution except in the case of a 4-deg incidence angle, which may be corrected by the introduction of distortions into one or both concentration stages.

Greenman, P.↗

Large-angle production of charged pions with 3-12.9 GeV/c incident protons on nuclear targets

Measurements of the double-differential {pi}{sup {+-}} production cross section in the momentum range 100{<=}p{<=}800 MeV/c and angle range 0.35{<=}{theta}{<=}2.15 rad in proton-beryllium, proton-carbon, proton-aluminium, proton-copper, proton-tin, proton-tantalum, and proton-lead collisions are presented. The data were taken with the large-acceptance HARP detector in the T9 beam line of the CERN PS. The pions were produced by proton beams in a momentum range from 3 to 12.9 GeV/c hitting a target with a thickness of 5% of a nuclear interaction length. Tracking and identification of the produced particles was performed by using a small-radius cylindrical Time Projection Chamber (TPC) placed inside a solenoidal magnet. Incident particles were identified by an elaborate system of beam detectors. Results are obtained for the double-differential cross sections d{sup 2}{sigma}/(dpd{theta}) at six incident proton beam momenta [3, 5, 8, and 8.9 GeV/c (Be only) and 12 and 12.9 GeV/c (Al only)]. They are based on a complete correction of static and dynamic distortions of tracks in the HARP TPC, which allows the complete statistics of the collected data set to be used. The results include and supersede our previously published results and are compatible with these. Results are compared with the GEANT4 and MARS Monte Carlo simulation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reducing distortion in an fm modulator.

Free-running oscillator incorporating correction circuit to improve linearity of voltage-variable capacitor for reducing second harmonic and intermodulation distortion

FREQUENCY MODULATION↗

Zoom lens compensator for a cylindrical window in laser anemometer uses

In laser anemometer systems, the flow fields under study are typically enclosed by a window. Aberration of a flat window can be corrected by a shift of the object distance. A zooming correction lens elimates the astigmatism caused by a thick cylindrical window and yields diffraction-limited performance for a monochromatic laser anemometer system. The effects of residual anamorphic distortion are discussed, and procedures for correcting these effects are presented.

Wernet, Mark P.↗

Beam based alignment and its relevance in Indus-2

Initially in the Indus-2 storage ring, the closed orbit distortion (COD) could be best corrected to 1.3 mm rms in the horizontal and 0.43 mm rms in the vertical plane. The strength of the corrector magnets required high values for COD correction. This revealed that offsets in COD readout by the beam position monitors (BPMs) played a role in not achieving a rms COD lower than the above value. Thus, the offset between the electrical center of BPMs and the magnetic center of the nearest quadrupole magnet could be estimated using the beam based alignment (BBA) method. It prefers that the quadrupole magnet is able to be controlled individually and active shunt power supply (ASPS) system was designed for this purpose that works efficiently. This paper describes the methodology of BBA, topology of ASPS and its performance, and COD minimization using the measured BPM offsets. After BBA, the COD could be reduced to 0.45 mm rms and 0.2 mm rms in horizontal and vertical planes, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface structure and equilibrium particle shape of the LiMn 2 O 4 spinel from first-principles calculations

First-principles density functional calculations were used to calculate surface properties of the LiMn 2 O 4 spinel. The calculations were benchmarked to obtain the correct semiconducting, Jahn-Teller distorted electronic ground state of bulk LiMn 2 O 4 and, using the same parameters, the predominant low-index polar surface facets (100), (110), and (111) were calculated to study their structure and stability. Following an investigation of possible surface terminations as well as surface layer reconstructions we find that the (111) LMO surface stabilizes through a targeted site exchange of the undercoordinated surface Mn cations with fully coordinated tetrahedral subsurface Li cations, effectively creating a partial inverse spinel arrangement at the surface. This reconstruction renders the (111) facet the most stable among the investigated facets. Here, the equilibrium (Wulff) shape of a LiMn 2 O 4 particle was constructed and exhibits a cubo-octahedral shape with predominant (1 1 1) facets, in agreement with common experimental findings for the spinel structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gravitational lens equation for embedded lenses; magnification and ellipticity

We give the lens equation for light deflections caused by point mass condensations in an otherwise spatially homogeneous and flat universe. We assume the signal from a distant source is deflected by a single condensation before it reaches the observer. We call this deflector an embedded lens because the deflecting mass is part of the mean density. The embedded lens equation differs from the conventional lens equation because the deflector mass is not simply an addition to the cosmic mean. We prescribe an iteration scheme to solve this new lens equation and use it to compare our results with standard linear lensing theory. We also compute analytic expressions for the lowest order corrections to image amplifications and distortions caused by incorporating the lensing mass into the mean. We use these results to estimate the effect of embedding on strong lensing magnifications and ellipticities and find only small effects, <1%, contrary to what we have found for time delays and for weak lensing, {approx}5%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Numerical Modeling of the Sensitivity of X-Ray Driven Implosions to Low-Mode Flux Asymmetries

In this study, the sensitivity of inertial confinement fusion implosions of the type performed on the National Ignition Facility (NIF) [1] to low-mode flux asymmetries has been investigated numerically. It is shown that large-amplitude, low-order mode shapes (Legendre polynomial P4), resulting from associated low order flux asymmetries, cause spatial variations in capsule and fuel momentum that prevent the DT “ice” layer from being decelerated uniformly by the hot spot pressure. This reduces the transfer of kinetic to internal energy of the central hot spot, thus reducing neutron yield. Furthermore, synthetic gated x-ray images indicate that the P4 component of hot spot self-emission shape is insensitive to P4 hot spot shapes, and a positive P4 asymmetry aliases itself as a negative or oblate P2 in these images. Correction of this apparent P2 distortion can further distort the implosion while creating a round x-ray image. Long wavelength asymmetries may be playing a significant role in the observed yield reduction of NIF DT implosions relative to detailed post-shot 2D simulations.

42 ENGINEERING↗

Nanoporous gold: a hierarchical and multiscale 3D test pattern for characterizing X-ray nano-tomography systems

Full-field transmission X-ray microscopy (TXM) is a well established technique, available at various synchrotron beamlines around the world as well as by laboratory benchtop devices. One of the major TXM challenges, due to its nanometre-scale resolution, is the overall instrument stability during the acquisition of the series of tomographic projections. The ability to correct for vertical and horizontal distortions of each projection image during acquisition is necessary in order to achieve the effective 3D spatial resolution. The effectiveness of such an image alignment is also heavily influenced by the absorption properties and strong contrast of specific features in the scanned sample. Here it is shown that nanoporous gold (NPG) can be used as an ideal 3D test pattern for evaluating and optimizing the performance of a TXM instrument for hard X-rays at a synchrotron beamline. Unique features of NPG, such as hierarchical structures at multiple length scales and high absorbing capabilities, makes it an ideal choice for characterization, which involves a combination of a rapid-alignment algorithm applied on the acquired projections followed by the extraction of a set of both 2D- and 3D-descriptive image parameters. This protocol can be used for comparing the efficiency of TXM instruments at different synchrotron beamlines in the world or benchtop devices, based on a reference library of scanned NPG samples, containing information about the estimated horizontal and vertical alignment values, 2D qualitative parameters and quantitative 3D parameters. The possibility to tailor the ligament sizes of NPG to match the achievable resolution in combination with the high electron density of gold makes NPG an ideal 3D test pattern for evaluating the status and performance of a given synchrotron-based or benchtop-based TXM setup.

36 MATERIALS SCIENCE↗

Quantitative Electroluminescence Imaging Analysis for Performance Estimation of PID-Influenced PV Modules

An empirical method for estimating relative power losses caused by potential-induced degradation (PID) for p-type solar cells and modules using quantitative electroluminescence (EL) analysis (QELA) is presented. First, EL images are corrected for camera- and perspective distortion. The relative power loss map is then calculated from the logarithmic ratio of two EL images, taken either before and after PID degradation or at different applied currents. Only the cell average of the resulting power loss map is evaluated. The highest power loss across each string is averaged to obtain the overall power loss. Consequently, for modules with three strings, three cells are averaged. The resulting power loss depends on the current applied. The conversion to equivalent irradiance allows for comparison of measured and estimated device performance. The analysis of roughly 2000 EL images and related current-voltage (I-V) curves indicates a good agreement between flash-test-measured and performance estimated using QELA. A relative root mean square error of 1-3% can be achieved.

14 SOLAR ENERGY↗

Quantitative Imaging with a Mobile Phone Microscope

Use of optical imaging for medical and scientific applications requires accurate quantification of features such as object size, color, and brightness. High pixel density cameras available on modern mobile phones have made photography simple and convenient for consumer applications; however, the camera hardware and software that enables this simplicity can present a barrier to accurate quantification of image data. This issue is exacerbated by automated settings, proprietary image processing algorithms, rapid phone evolution, and the diversity of manufacturers. If mobile phone cameras are to live up to their potential to increase access to healthcare in low-resource settings, limitations of mobile phone–based imaging must be fully understood and addressed with procedures that minimize their effects on image quantification. Here we focus on microscopic optical imaging using a custom mobile phone microscope that is compatible with phones from multiple manufacturers. We demonstrate that quantitative microscopy with micron-scale spatial resolution can be carried out with multiple phones and that image linearity, distortion, and color can be corrected as needed. Using all versions of the iPhone and a selection of Android phones released between 2007 and 2012, we show that phones with greater than 5 MP are capable of nearly diffraction-limited resolution over a broad range of magnifications, including those relevant for single cell imaging. We find that automatic focus, exposure, and color gain standard on mobile phones can degrade image resolution and reduce accuracy of color capture if uncorrected, and we devise procedures to avoid these barriers to quantitative imaging. By accommodating the differences between mobile phone cameras and the scientific cameras, mobile phone microscopes can be reliably used to increase access to quantitative imaging for a variety of medical and scientific applications.

59 BASIC BIOLOGICAL SCIENCES↗

Digital image processing for the earth resources technology satellite data.

This paper discusses the problems of digital processing of the large volumes of multispectral image data that are expected to be received from the ERTS program. Correction of geometric and radiometric distortions are discussed and a byte oriented implementation is proposed. CPU timing estimates are given for a System/360 Model 67, and show that a processing throughput of 1000 image sets per week is feasible.

Will, P. M.↗

The data-handling problem with television recording of spectra.

A television tube is a useful way to record a many-element picture such as is obtained from an echelle spectrograph. The signal on the tube target is scanned and relayed to the data-processing center where it must be reconstituted into the scene that was present in the focal plane of the spectrograph camera. A typical television frame will contain four million bits of information which must be processed to remove transmission errors and random noise pulses, to remove periodic noise, to correct for optical and electrical distortion, to remove sensitivity variations across the face of the tube, to calibrate from the photoelectrons back to incident energy, and to provide a wavelength scale. Results of a study of these problems is presented.

Underhill, A. B.↗

Thermographic mosaic of Yellowstone National Park

An uncontrolled aerial thermographic mosaic of Yellowstone National Park was assembled from the videotape record of 13 individual thermographs obtained with linescan radiometers. Post mission processing of the videotape record rectified the nadir line to a topographic map base, corrected for v/h variations in adjacent flight lanes, corrected for yaw and pitch distortions, and distortions produced by nonlinearity of the side-wise scan. One of the purposes of the thermographic study was to delineate the areas of thermal emission (hot springs, geysers, etc.) throughout the Park, a study which could have great value in reconnaissance surveys of geothermal areas in remote regions or regions of high relief.

Williams, R. S., Jr.↗