Search NASA⌕ Search

SEARCH · Search NASA

Results for “Double shell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Feasibility Study for Cathodic Protection of Waste Tanks at Hanford

The Hanford Nuclear Reservation site contains approximately 211 million liters of radioactive and chemically hazardous waste arising from nuclear weapons production, beginning with World War II, and continuing through the Cold War. The waste is stored in 177 carbon-steel underground storage tanks, of which 149 are single-shell tanks (SSTs) and the remaining are double-shell tanks (DSTs). The mission of an ongoing River Protection Project is to retrieve the waste from the underground storage tanks and then treat and immobilize (i.e., vitrify) it for disposal. Waste from the older SSTs is being progressively retrieved into the newer DSTs for storage pending treatment, immobilization, and disposal. Waste chemistry controls are in place to mitigate general corrosion, pitting corrosion, and stress corrosion cracking (SCC) and minimize corrosion risks to the carbon steel tank liners of DST at the Hanford Site. The chemistry control program focuses on preserving liner integrity while balancing the need for caustic/nitrite additions that have large downstream impacts on vitrification. Some of the DSTs store salt cake or sludge waste layers contain out-of-specification interstitial liquids that contact the primary tank bottom or sidewall. Remediation of such layers through chemical additions is not practical. At the present time, the most significant leak integrity concern at Hanford is for corrosion of the tank bottoms of DSTs where the solids layer is out of specification because of hydroxide ion depletion and consequently, pH values that are less than 12. Cathodic protection (CP) has been proposed as a possible way to protect the liners of such tanks against corrosion. The objective of this project was to investigate the feasibility of applying CP to Hanford DSTs to mitigate internal corrosion of the carbon steel tank primary liners. The scope of the project included (1) a literature review on the application of CP to storage tank systems, in general, and to waste tanks at the Savannah River Site (SRS) and Hanford, (2) a review of the finite element analysis (FEA) model recently developed to evaluate potentials for a DST, and (3) the development of a boundary element analysis (BEA) model for CP for a DST. Tank AN-107, one of the Hanford DSTs, was selected for this work because (1) the bottommost waste layer in the tank is out-of-specification, and (2) electrochemical and resistivity data, based on recent waste sampling and testing, are available for this tank. The overarching conclusion of this study is that, based on the available information, it is feasible to apply CP to mitigate internal corrosion of the primary liners of the Hanford DSTs. However, significant additional information and work are required before a CP system can be designed. Recommendations for next steps in the design of the CP system will be presented.

WIERSMA, BRUCE↗

FY24 Task 5: Leachate Disposition

Directly feeding sludge solids to the high-level waste (HLW) Waste Treatment Plant represents an alternative flowsheet seeking to initiate sludge processing as soon as possible. Key processing functions previously captured during baseline pretreatment operations include leaching and washing prior to solids concentration. These operations should be considered in the potential direct feed flowsheets to maximize waste feed loading, minimize HLW volume, and mitigate corrosion challenges associated with vitrification of high phosphate and fluoride concentrations. Additionally, single-shell tank (SST) retrievals and waste transfers to double-shell tanks (DSTs) in a direct feed flowsheet would likely also benefit from some level of leaching, washing, and solids concentration in order to reduce DST space and mission duration. These operations could occur in a new facility or potentially in available DSTs. If washing and leaching are utilized, an effective disposition pathway for the wash water and leachate solutions are needed. Three target species that benefit significantly from leaching and washing are phosphate, fluoride and aluminum. Phosphate (PO 4 3- ) and fluoride (F - ) can contribute substantially to the amount of carrier fluid needed for dissolution, and the resulting volume of liquid generated. Disposition of this retrieval solution should be evaluated in order to prevent crystallization of these anions throughout system processing. Since there is a high probability that any retrieval solutions will be at or near their PO 4 3- and F - solubility limits, evaporation or blending with a high Na supernate (>3.5 M) is not recommended for the wash water streams without a method to remove precipitants prior to solution disposal. Additionally, aluminum present in the southeast quadrant of the Hanford site represents roughly 60% of the waste solids in the initial processing tanks. These aluminum solids are in the form of gibbsite (Al(OH) 3 ) and can pose significant challenges for processing due to the fast-settling times and high solids loading associated with these materials. Easily remediated by caustic addition to the solids, these wash solutions could be processed through crystalline silicotitanate (CST) ion exchange columns to prepare the supernate solutions for disposition. The current target for feed conditions to the Low Activity Waste (LAW) melter are waste streams that contain nominally 5-6 M Na. Fractions within the tanks contain upwards of 0.2 M phosphate and fluoride in solution at 3.5 M Na. Concentrating these solutions above 5 M Na would result in an exceedance of the solubility limits, and potential for uncontrolled precipitation of the phosphate and fluoride crystal material. The resulting crystalline salt material is typically sodium fluoride phosphate, also referred to as natrophosphate (Na 7 FPO 4 ·19H 2 O). Salt phases are of importance in tank waste due to their chemical reactivity, which can result in precipitation, dissolution, or transformation, impacting any downstream processes (Bolling et al. 2020, Russell, Snow, and Peterson 2010). Salt generation and precipitation could pose challenges by causing system plugging and melter corrosion if left in the supernate stream, or limit sodium molarity of the supernate that would be accepted without incident in waste operations. To understand the impact of this salt generation, the crystallization of natrophosphate in multiple simulant feed matrices was studied to understand the implications of various tank waste supernate chemistries. Three matrices were examined: high PO 4 3- /low F - , low PO 4 3- /high F - , and an average matrix. Subsequent testing was performed with the average matrix with the inclusion of CsNO 3 , and a final run with the average matrix including CsNO 3 and a 137 Cs spike for tracer purposes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Waste Retrieval and Inspection Operations in Hanford Tank 241-AY-102 - 18234

In August 2012, a periodic annulus inspection of tank 241-AY-102 (AY-102) identified a leak from the primary tank into the secondary containment. A pumping plan was developed in 2013 to provide a path forward for recommended remediation actions to be implemented as part of the AY-102 Recovery Project. On March 21, 2014, the Washington State Department of Ecology issued an Administrative Order requiring Washington River Protection Solutions and the United States Department of Energy to conduct actions related to and including the removal of waste from AY-102. The parties agreed to resolve the appeal of the Administrative Order through a Settlement Agreement which addressed the remaining requirements and implemented enforceable milestone dates, including completion of waste removal operations, and performance of an inspection aimed at determining the cause of the leak. The AY-102 Recovery Project was developed to address the Settlement Agreement requirements. While retrieval of waste from Single-Shell Tanks has been performed at Hanford for decades, retrieval from Double-Shell Tank AY-102 required adaptation of the existing technologies to a new environment on a larger scale than previously encountered. Despite countless challenges and obstacles encountered throughout, the project successfully completed system design, fabrication, installation, testing, and retrieval operations within a highly compressed, aggressive schedule. Waste removal activities in AY-102 completed in February 2017. Subsequent inspection activities were completed as part of a multi-step process aimed at determining the likely cause of failure and assessing the feasibility of repair. A variety of input data were used in evaluating the likely failure mechanism, such as video examinations that revealed numerous through-floor penetrations and significant degradation across the visible surface area. Based on the operational history of the tank, corrosion testing and analysis, and the visual appearance of the confirmed leak sites, service-induced pitting corrosion due to the historic waste composition and operating conditions appears to be the primary degradation mechanism leading to failure of the tank. The inspection data has demonstrated that repairing and returning AY-102 to service would likely introduce substantial technical, logistical, and financial challenges due to the extent of bottom-plate damage. As a result, tank AY-102 will ultimately be closed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Machine learning for detection of 3D features using sparse x-ray tomographic reconstruction

In many inertial confinement fusion (ICF) experiments, the neutron yield and other parameters cannot be completely accounted for with one and two dimensional models. This discrepancy suggests that there are three dimensional effects that may be significant. Sources of these effects include defects in the shells and defects in shell interfaces, the fill tube of the capsule, and the joint feature in double shell targets. Due to their ability to penetrate materials, x rays are used to capture the internal structure of objects. Methods such as computational tomography use x-ray radiographs from hundreds of projections, in order to reconstruct a three dimensional model of the object. In experimental environments, such as the National Ignition Facility and Omega-60, the availability of these views is scarce, and in many cases only consists of a single line of sight. Mathematical reconstruction of a 3D object from sparse views is an ill-posed inverse problem. These types of problems are typically solved by utilizing prior information. Neural networks have been used for the task of 3D reconstruction as they are capable of encoding and leveraging this prior information. We utilize half a dozen, different convolutional neural networks to produce different 3D representations of ICF implosions from the experimental data. Deep supervision is utilized to train a neural network to produce high-resolution reconstructions. These representations are used to track 3D features of the capsules, such as the ablator, inner shell, and the joint between shell hemispheres. Machine learning, supplemented by different priors, is a promising method for 3D reconstructions in ICF and x-ray radiography, in general.

Wolfe, Bradley T. (ORCID:0000000268301614)↗

Neural simulation-based inference of the Higgs trilinear self-coupling via off-shell Higgs production

One of the forthcoming major challenges in particle physics is the experimental determination of the Higgs trilinear self-coupling. While efforts have largely focused on on-shell double- and single-Higgs production in proton-proton collisions, off-shell Higgs production has also been proposed as a valuable complementary probe. In this article, we design a hybrid neural simulation-based inference (NSBI) approach to construct a likelihood of the Higgs signal incorporating modifications from the Standard Model effective field theory (SMEFT), relevant background processes, and quantum interference effects. It leverages the training efficiency of matrix-element-enhanced techniques, which are vital for robust SMEFT applications, while also incorporating the practical advantages of classification-based methods for effective background estimates. We demonstrate that our NSBI approach achieves sensitivity close to the theoretical optimum and provide expected constraints for the high-luminosity upgrade of the Large Hadron Collider. While we primarily concentrate on the Higgs trilinear self-coupling, we also consider constraints on other SMEFT operators that affect off-shell Higgs production.

Ghosh, Aishik [Univ. of California, Irvine, CA (Un↗

Plasma Radiation Source on the Basis of the Gas Puff with Outer Plasma Shell in the Circuit of a Mega-Ampere Load Current Doubler

Characteristics of Z-pinch plasma radiation in the form of a double shell neon gas puff with outer plasma shell are investigated in the microsecond implosion mode. Experiments are performed using a GIT-12 mega-joule generator with load current doubler having a ferromagnetic core at implosion currents up to 5 MA. Conditions for matching of the nonlinear load with the mega-ampere current multiplier circuit are determined. The load parameters (plasma shell characteristics and mass and geometry of gas puff shells) are optimized on the energy supplied to the gas puff and n energy characteristics of radiation. It is established that the best modes of K-shell radiation in neon are realized for such radial distribution of the gas-puff material at which the compression velocity of the shell is close to a constant and amounts to 27–30 cm/μs. In these modes, up to 40% of energy supplied to the gas puff is converted into K-shell radiation. The reasons limiting the efficiency of the radiation source with increasing implosion current are analyzed. A modernized version of the energy supply from the current doubler to the Z-pinch is proposed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gyroid Structures at Highly Asymmetric Volume Fractions by Blending of ABC Triblock Terpolymer and AB Diblock Copolymer

Here, we investigated, via small angle X-ray scattering and transmission electron microscopy, the morphologies of binary blend of polyisoprene- b -polystyrene- b -poly(2-vinylpyridine) (ISP) triblock terpolymer and polyisoprene-b-polystyrene (IS) diblock copolymer. An asymmetric ISP with volume fractions ( f ) of 0.12, 0.75, and 0.13 for PI, PS, and P2VP blocks, respectively, showed a new morphology: Coexistence of spheres and cylinders with tetragonal packing. Asymmetric IS with f I = 0.11 and f S =0.89 showed conventional body-centered cubic spherical microdomains. Very interestingly, a binary blend of ISP and IS with overall volume fractions of f I = 0.12, f S = 0.79, and f P = 0.09 exhibited core-shell double gyroid (CSG: Q 230 space group), where PI consists of thin core and PS forms thick shell, while P2VP becomes thin matrix. It is very unusual to form highly asymmetric CSG with the matrix having very small volume fraction (0.09).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hanford Technology Development (Tank Farms) - 12509

The mission of the Department of Energy's Office of River Protection (ORP) is to safely retrieve and treat the 56 million gallons of Hanford's tank waste and close the Tank Farms to protect the Columbia River. The millions of gallons of tank waste are a byproduct of decades of plutonium production. After irradiated fuel rods were taken from the nuclear reactors to the processing facilities at Hanford they were exposed to a series of chemicals designed to dissolve away the rod, which enabled workers to retrieve the plutonium. Once those chemicals were exposed to the fuel rods they became radioactive and extremely hot. They also couldn't be used in this process more than once. Because the chemicals are caustic and extremely hazardous to humans and the environment, underground storage tanks were built to hold these chemicals until a more permanent solution could be found. One key part of the ongoing work at Hanford is retrieving waste from the single-shell tanks, some of which have leaked in the past, and transferring that waste to the double-shell tanks - none of which have ever leaked. The 56 million gallons of radioactive tank waste is stored in 177 underground tanks, 149 of which are single-shell tanks built between 1943 and 1964. The tanks sit approximately 250 feet above the water table. Hanford's single-shell tanks are decades past their 20-year design life. In the past, up to 67 of the single-shell tanks are known or suspected to have leaked as much as one million gallons of waste to the surrounding soil. Starting in the late 1950's, waste leaks from dozens of the single-shell tanks were detected or suspected. Most of the waste is in the soil around the tanks, but some of this waste is thought to have reached groundwater. The Vadose Zone Project was established to understand the radioactive and chemical contamination in the soil beneath the tanks as the result of leaks and discharges from past plutonium-production operations. The vadose zone is the area of soil between the ground surface and the water table 200-to-300 feet below. The project tracks and monitors contamination in the soil. Technologies are being developed and deployed to detect and monitor contaminants. Interim surface barriers, which are barriers put over the single-shell tanks, prevent rain and snow from soaking into the ground and spreading contamination. The impermeable barrier placed over T Farm, which was the site of the largest tank waste leak in Hanford's history, is 60,000 square feet and sloped to drain moisture outside the tank farm. The barrier over TY Farm is constructed of asphalt and drains moisture to a nearby evaporation basin. Our discussion of technology will address the incredible challenge of removing waste from Hanford's single-shell tanks. Under the terms of the Tri-Party Agreement, ORP is required to remove 99 percent of the tank waste, or until the limits of technology have been reached. All pumpable liquids have been removed from the single-shell tanks, and work now focuses on removing the non-pumpable liquids. Waste retrieval was completed from the first single-shell tank in late 2003. Since then, another six single-shell tanks have been retrieved to regulatory standards. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Common Origin of Normal Type Ia Supernovae Suggested by the Photometric Diversity

In recent years, with the increasing number of type Ia supernovae (SNe Ia) discovered soon after their explosions, a nonnegligible fraction of SNe Ia with early-excess emissions (EExSNe Ia) have been confirmed. In this paper, we present a total of 67 early-phase normal SNe Ia from published papers and ongoing transient survey projects to systematically investigate their photometric behaviors from very early time. We found that EExSNe Ia in our sample have longer rise and brighter peak luminosities compared to non-EExSNe Ia. Moreover, EExSNe Ia commonly have “tiny red bump” or “blue plateau” features in the early B − V color while non-EExSNe Ia show blueward evolution from the very beginning. Here, we propose that the thin He-shell double detonation scenario can phenomenologically explain the photometric diversities of normal SNe Ia considering different white dwarf–He-shell mass combinations and the viewing angle effect, implying a unified explosion mechanism of normal-type SNe Ia. To further verify the possible common origin of normal SNe Ia, systematical studies of multiband photometric and spectral properties of early-phase SNe Ia through the new-generation wide-field time-domain survey facilities and global real-time follow-up networks are highly needed.

Wu, Weiyu↗

Improved Management of the Technical Interfaces Between the Hanford Tank Farm Operator and the Hanford Waste Treatment Plant - 13383

The Department of Energy (DOE) is constructing the Waste Treatment and Immobilization Plant (WTP) at the Hanford site in Washington to treat and immobilize approximately 114 million gallons of high level radioactive waste (after all retrievals are accomplished). In order for the WTP to be designed and operated successfully, close coordination between the WTP engineering, procurement, and construction contractor, Bechtel National, Inc. and the tank farms operating contractor (TOC), Washington River Protection Solutions, LLC, is necessary. To develop optimal solutions for DOE and for the treatment of the waste, it is important to deal with the fact that two different prime contractors, with somewhat differing contracts, are tasked with retrieving and delivering the waste and for treating and immobilizing that waste. The WTP and the TOC have over the years cooperated to manage the technical interface. To manage what is becoming a much more complicated interface as the WTP design progresses and new technical issues have been identified, an organizational change was made by WTP and TOC in November of 2011. This organizational change created a co-located integrated project team (IPT) to deal with mutual and interface issues. The Technical Organization within the One System IPT includes employees from both TOC and WTP. This team has worked on a variety of technical issues of mutual interest and concern. Technical issues currently being addressed include: - The waste acceptance criteria; - Waste feed delivery and the associated data quality objectives (DQO); - Evaluation of the effects of performing a riser cut on a single shell tank on WTP operations; - The disposition of secondary waste from both TOC and WTP; - The close coordination of the TOC double shell tank mixing and sampling program and the Large Scale Integrated Test (LSIT) program for pulse jet mixers at WTP along with the associated responses to the Defense Nuclear Facilities Safety Board (DNFSB) Recommendation 2010-2; - Development of a set of alternatives to the current baseline that involve aspects of direct feed, feed conditioning, and design changes. The One System Technical Organization has served WTP, TOC, and DOE well in managing and resolving issues at the interface. This paper describes the organizational structure used to improve the interface and several examples of technical interface issues that have been successfully addressed by the new organization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AUTOMATED LEAK DETECTION OF BURIED TANKS USING GEOPHYSICAL METHODS AT THE HANFORD NUCLEAR SITE

At the Hanford Nuclear Site in Washington State, the Department of Energy oversees the containment, treatment, and retrieval of liquid high-level radioactive waste. Much of the waste is stored in single-shelled tanks (SSTs) built between 1943 and 1964. Currently, the waste is being retrieved from the SSTs and transferred into newer double-shelled tanks (DSTs) for temporary storage before final treatment. Monitoring the tanks during the retrieval process is critical to identifying leaks. An electrically-based geophysics monitoring program for leak detection and monitoring (LDM) has been successfully deployed on several SSTs at the Hanford site since 2004. The monitoring program takes advantage of changes in contact resistance that will occur when conductive tank liquid leaks into the soil. During monitoring, electrical current is transmitted on a number of different electrode types (e.g., steel cased wells and surface electrodes) while voltages are measured on all other electrodes, including the tanks. Data acquisition hardware and software allow for continuous real-time monitoring of the received voltages and the leak assessment is conducted through a time-series data analysis. The specific hardware and software combination creates a highly sensitive method of leak detection, complementing existing drywell logging as a means to detect and quantify leaks. Working in an industrial environment such as the Hanford site presents many challenges for electrical monitoring: cathodic protection, grounded electrical infrastructure, lightning strikes, diurnal and seasonal temperature trends, and precipitation, all of which create a complex environment for leak detection. In this discussion we present examples of challenges and solutions to working in the tank farms of the Hanford site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Precision mass measurement of lightweight self-conjugate nucleus 80 Zr

Protons and neutrons in the atomic nucleus move in shells analogous to the electronic shell structures of atoms. The nuclear shell structure varies due to changes of the nuclear mean field with the number of neutrons N and protons Z, and these variations can be probed by measuring mass differences between nuclei. The N=Z=40 self-conjugate nucleus 80 Zr is of particular interest as its proton and neutron shell structures are expected to be very similar, and its ground state is highly deformed. Here, we provide evidence for the existence of a deformed double shell closure in 80Zr through high precision Penning trap mass measurements of 80-83 Zr. Our mass values show that 80Zr is significantly lighter, and thus more strongly bound than predicted. This can be attributed to the deformed shell closure at N=Z=40 and the large Wigner energy. A statistical Bayesian model mixing analysis employing several global nuclear mass models demonstrates difficulties with reproducing the observed mass anomaly using current theory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Early Signal of Emerging Nuclear Collectivity in Neutron-Rich 129Sb

Radioactive 129Sb, which can be treated as a proton plus semimagic 128Sn core within the particle-core coupling scheme, was studied by Coulomb excitation. Reduced electric quadrupole transition probabilities, B(E2), for the 2+Ⓧπg7/2 multiplet members and candidate πd5/2 state were measured. The results indicate that the total electric quadrupole strength of 129Sb is a factor of 1.39(11) larger than the 128Sn core, which is in stark contrast to the expectations of the empirically successful particle-core coupling scheme. Shell-model calculations performed with two different sets of nucleon-nucleon interactions suggest that this enhanced collectivity is due to constructive quadrupole coherence in the wave functions stemming from the proton-neutron residual interactions, where adding one nucleon to a core near a double-shell closure can have a pronounced effect. The enhanced electric quadrupole strength is an early signal of the emerging nuclear collectivity that becomes dominant away from the shell closure.

Gray, Tim↗

Hanford 200 West Area Flowsheet Data to Support Waste Treatment and Disposal Request for Proposal

This report documents the 200 West Area (200W) flowsheet supplemental data needed to support the Request for Proposal (RFP) to procure onsite and/or offsite treatment and disposal capabilities for West Area pretreated1 tank waste (PTW). The data provided in this document is based on the results of a 200W flowsheet model run evaluating single-shell tank (SST) retrievals for all S, SX, and U Farms, except for Tank S-112, which was retrieved in March of 2007 (HNF-EP-0182, Waste Tank Summary Report for Month End August 31, 2024). The evaluation also includes the waste inventory in double-shell tanks (DSTs) in SY Farm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stable and confined burn in a Revolver ignition capsule

In this paper, the main burn phase physics in a Revolver ignition capsule is analyzed and found to exhibit a new feature where pusher stagnation is persistent and burn occurs with the fuel at a fixed volume. The pressure and density gradients at the fuel-pusher interface are both positive making it stable to Rayleigh-Taylor growth. Expansion cooling and RT mixing are absent from the Revolver burn during this time. The effect is due to the massive heavy metal pusher shell being compressed during implosion and heated on an inner layer by the Marshak wave. The pusher is driven to a higher pressure than the DT fuel and becomes a fuel confining shell starting at stagnation and continuing past the time of peak burn. This period of persistent stagnation lasts for approximately 100 ps (in the baseline design) with a fuel burnup during stagnation of 40%. Finally, this behavior does not occur in any other capsule designs, including the double shell schemes that also employ a heavy metal pusher.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

One System Integrated Project Team: Retrieval And Delivery Of The Hanford Tank Wastes For Vitrification In The Waste Treatment Plant

The One System Integrated Project Team (IPT) was formed in late 2011 as a way for improving the efficiency of delivery and treatment of highly radioactive waste stored in underground tanks at the U.S. Department of Energy's (DOE's) 586-square-mile Hanford Site in southeastern Washington State. The purpose of the One System IPT is to improve coordination and integration between the Hanford's Waste Treatment Plant (WTP) contractor and the Tank Operations Contractor (TOC). The vision statement is: One System is a WTP and TOC safety conscious team that, through integrated management and implementation of risk-informed decision and mission-based solutions, will enable the earliest start of safe and efficient treatment of Hanford's tank waste, to protect the Columbia River, environment and public. The IPT is a formal collaboration between Bechtel National, Inc. (BNI), which manages design and construction of the WTP for the U.S. Department of Energy's Office of River Protection (DOEORP), and Washington River Protection Solutions (WRPS), which manages the TOC for ORP. More than fifty-six (56) million gallons of highly radioactive liquid waste are stored in one hundred seventy-seven (177) aging, underground tanks. Most of Hanford's waste tanks - one hundred forty-nine (149) of them - are of an old single-shell tank (SST) design built between 1944 and 1964. More than sixty (60) of these tanks have leaked in the past, releasing an estimated one million gallons of waste into the soil and threatening the nearby Columbia River. There are another twenty-eight (28) new double-shelled tanks (DSTs), built from 1968 to 1986, that provide greater protection to the environment. In 1989, DOE, the U.S. Environmental Protection Agency (EPA), and the Washington State Department of Ecology (Ecology) signed a landmark agreement that required Hanford to comply with federal and state environmental standards. It also paved the way for agreements that set deadlines for retrieving the tank wastes and for building and operating the WTP. The tank wastes are the result of Hanford's nearly fifty (50) years of plutonium production. In the intervening years, waste characteristics have been increasingly better understood. However, waste characteristics that are uncertain and will remain as such represent a significant technical challenge in terms of retrieval, transport, and treatment, as well as for design and construction ofWTP. What also is clear is that the longer the waste remains in the tanks, the greater the risk to the environment and the people of the Pacific Northwest. The goal of both projects - tank operations and waste treatment - is to diminish the risks posed by the waste in the tanks at the earliest possible date. About two hundred (200) WTP and TOC employees comprise the IPT. Individual work groups within One System include Technical, Project Integration & Controls, Front-End Design & Project Definition, Commissioning, Nuclear Safety & Engineering Systems Integration, and Environmental Safety and Health and Quality Assurance (ESH&QA). Additional functions and team members will be added as the WTP approaches the operational phase. The team has undertaken several initiatives since its formation to collaborate on issues: (1) alternate scenarios for delivery of wastes from the tank farms to WTP; (2) improvements in managing Interface Control Documents; (3) coordination on various technical issues, including the Defense Nuclear Facilities Nuclear Safety Board's Recommendation 2010-2; (4) deployment of the SmartPlant Foundation-configuration Management System; and (5) preparation of the joint contract deliverable of the Operational Readiness Support Plan.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗