Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic load balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Integration of Thermoelectric Generator and Wireless Sensor Node Simulators

This report focuses on integrating TEG and WSN simulators with DC-DC converter as an interface. Here DC stands for direct current. DC-DC converter is essential to balance a wide range of analog, digital, and radio loads acting on the energy source. Also, the voltage level generated by TEGs under varying temperature conditions could be low, irregular, and insufficient to operate WSN, therefore DC-DC is required to boost up the voltage to a desired level. Most of the main problems of DC-DC converters used in TEG system are related to impedance matching between the internal resistance of TEG and the input resistance of DC-DC converter. This report would address the issue associated with dynamic impedance matching under varying temperature conditions in the effort to integrate TEG and WSN. In this effort, dynamic impedance matching algorithms like perturb and observe (P&O) and extremum seeking control (ESC) algorithms will de implemented and compared to achieve maximum peak power tracking (MPPT). In addition, the report will summarize the experimental study performed at BSU on profiling behavior of WSN prototype.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Computer Science Research Needs for Parallel Discrete Event Simulation (PDES)

Historically, scientific computing efforts have demonstrated the clear need for, and effective use of, supercomputing with traditional time-stepped simulations. Nevertheless, there are several areas in the mission spaces of the U.S. Department of Energy and other agencies waiting to tap advanced computing research using a different, discrete event style of modeling, simulation, and analysis. These span a wide spectrum of applications including energy grid resilience, urban planning and policy, transportation science, building technologies, emergency response and planning, environmental impact analysis, computational epidemiology, Internet communications, cyber security, and cyber-physical systems, to name only a few. Even within traditional scientific applications, the role of discrete event modes of execution is increasing in the form of new event-based mathematical solvers such as quantized state integration methods and discrete-continuous hybrid system solvers. Co-design of advanced supercomputing hardware systems is another area that exploits discrete event simulation at its core for effective analyses. Complex systems, entity behaviors and interconnections play a significant role in all these applications, which are mapped to large-scale models with discrete event formulations. To make advancements in all the aforementioned scientific areas, many technical aspects need to be more thoroughly studied and deeply understood in parallel discrete event simulation (PDES). The unique dynamics inherent in a discrete event modeling approach, by their very nature, intersect and influence the entire stack of the computing system, including (a) the unique nature of the instruction sets exercised in PDES workloads without a predominance of high-precision floating point operations, (b) virtual time-constrained multi-threaded execution of many logical processes per processor, (c) extremely variable and difficult to predict network traffic characteristics, (d) interfaces and inter-dependencies with machine learning and artificial intelligence codes at higher software layers, and (e) highly challenging load balancing needs, especially in effectively accounting for accelerated/extremely heterogeneous computing in current and future high-performance computing systems. Efficient and accurate parallel execution of PDES workloads is also dominated by challenges in dealing with their asynchronous concurrency fundamentally present at the model level. Conservative synchronization, optimistic/speculative synchronization, and their hybrid schemes open new questions in fundamental computer science with respect to reversibility of computation and prediction (lookahead) of behaviors inherent within model codes. On the implementation front, there are relatively few scalable, general-purpose parallel discrete event simulators in the world, and even fewer have been studied on emerging hardware platforms. To enable scientific advances using PDES, the research needs in computer science must also be pursued and met in the intersection of the algorithmic and hardware-aware aspects of scalable PDES engines. This report is aimed at capturing a computer science-oriented view of this important area of research in PDES, presenting a sample of important applications with their inherent discrete event technology elements. Needs are outlined in core areas of parallel discrete event research as well as cross-cutting directions in computer science research that positively impact scientific advancements across several important application areas. A selection of priority research opportunities in advanced computing for PDES is identified to serve as reference for key research topics and their order of importance for scientific advancements.

97 MATHEMATICS AND COMPUTING↗

Designing Dynamic Wireless Power Transfer Corridors for Heavy Duty Battery Electric Commercial Freight Vehicles

The use of wireless power transfer systems, consisting of inductive electrical coils on the vehicle and the power source may be designed for dynamic operations where the vehicle will absorb energy at highway speeds from transmitting coils in the road. This has the potential to reduce the onboard energy storage requirements for vehicles while enabling significantly longer missions. This paper presents an approach to architecting a dynamic wireless power transfer corridor for heavy duty battery electric commercial freight vehicles. By considering the interplay of roadway power capacity, roadway and vehicle coil coverage, seasonal road traffic loading, freight vehicle class and weight, vehicle mobility energy requirements, on-board battery chemistry, non-electrified roadway vehicle range requirements, grid capacity, substation locations, and variations in electricity costs, we minimize the vehicle TCO by architecting the electrified roadway and the vehicle battery simultaneously. The idea optimizes battery size and chemistry so that the depth of discharge between recharge events and expected life are balanced, thus fully utilizing the energy available throughout the course of the battery system's life. The approach is illustrated by applying it to the I-75 freight corridor, where the framework developed may be expanded and applied to a larger interstate system, expanded regional corridor, or other transportation network.

Sujan, Vivek↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Power Grid Simulation Testbed for Transactive Energy Management Systems

To effectively engage demand-side and distributed energy resources (DERs) for dynamically maintaining the electric power balance, the challenges of controlling and coordinating building equipment and DERs on a large scale must be overcome. Although several control techniques have been proposed in the literature, a significant obstacle to applying these techniques in practice is having access to an effective testing platform. Performing tests at scale using real equipment is impractical, so simulation offers the only viable route to developmental testing at scales of practical interest. Existing power-grid testbeds are unable to model individual residential end-use devices for developing detailed control formulations for responsive loads and DERs. Furthermore, they cannot simulate the control and communications at subminute timescales. To address these issues, this paper presents a novel power-grid simulation testbed for transactive energy management systems. Detailed models of primary home appliances (e.g., heating and cooling systems, water heaters, photovoltaic panels, energy storage systems) are provided to simulate realistic load behaviors in response to environmental parameters and control commands. The proposed testbed incorporates software as it will be deployed, and enables deployable software to interact with various building equipment models for end-to-end performance evaluation at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Robust and Flexible Design for GCEP Unattended Online Enrichment Monitoring: An OLEM Collection Node Network

Oak Ridge National Laoratory (ORNL) has engineered an on-line enrichment monitor (OLEM) to continuously measure U-235 emissions from the UF6 gas flowing through a unit header pipe of a gas centrifuge enrichment plant (GCEP) as a component of the International Atomic Energy Agency s (IAEA) new generation of technology to support enrichment plant safeguards1. In contrast to other enrichment monitoring approaches, OLEM calibrates and corrects for the pressure and temperature dependent UF6 gas-density without external radiation sources by using the inherent unit header pipe pressure dynamics and combining U-235 gamma-ray spectrometery using a shielded NaI detector with gas pressure and temperature data near the spectrum measurement point to obtain the enrichment of the gas as a function of time. From a safeguards perspective, OLEM can provide early detection of a GCEP being misused for production of highly enriched uranium, but would not detect directly the isolation and use of a cascade within the production unit to produce HEU. OLEM may also reduce the number of samples collected for destructive assay and, if coupled with load cell monitoring, could support isotope mass balance verification and unattended cylinder verification. The earlier paper presented OLEM as one component along with shared load cells and unattended cylinder verification, in the IAEA emering toolbox for unattended instruments at GCEPs1 and described the OLEM concept and how previous modeling studies and field measurements helped confirm the viability of a passive on-line enrichment monitor for meeting IAEA objectives and to support the development of performance targets. Phase I of the United States Support Program (USSP) OLEM project completed a preliminary hardware, software and communications design; phase II will build and test field prototypes in controlled laboratory settings and then at an operational facility. That paper also discussed many of the OLEM collection node commercial off the shelf (COTS) components and summarized the OLEM collection node data security provisions. This paper will discuss a secure and redundant network of OLEM collection nodes, auxiliary detection units and supporting junction boxes distributed throughout a facility for monitoring enrichment on product, feed and tails unit header pipes; the purpose and capability of the built-in Electronic Optical Sealing System (EOSS) network gateway; and a network approach for obtaining reliable and authenticated pressure measurements.

Younkin, James R↗

Data-driven Fault Tolerance for Work Stealing Computations

Checkpoint-restart approaches to fault tolerance typically roll back all the processes to the previous checkpoint in the event of a failure. Work stealing is a promising technique to dynamically tolerate variations in the execution environment, including faults, system noise, and energy constraints. In this paper, we present fault tolerance mechanisms for task parallel computations, a popular computation idiom, employing work stealing. The computation is organized as a collection of tasks with data in a global address space. The completion of data operations, rather than the actual messages, is tracked to derive an idempotent data store. This information is used to accurately identify the tasks to be re-executed, therefore to recompute only the lost data, in the presence of random work stealing. We consider three recovery schemes that present distinct trade-offs -- lazy recovery with potentially increased re-execution cost, immediate collective recovery with associated synchronization overheads, and noncollective recovery enabled by additional communication. We employ distributed work stealing to dynamically rebalance the tasks on the live processes and evaluate the three schemes using candidate application benchmarks. We demonstrate that the overheads (space and time) of the fault tolerance mechanism are low, the cost incurred due to failures are small, and the overheads decrease with per-process work at scale.

fault tolerance, task parallelism, load balancing,↗

Rigorous Kinetic Modeling and Optimization Study of a Modified Claus Unit for an Integrated Gasification Combined Cycle (IGCC) Power Plant with CO{sub 2} Capture

The modified Claus process is one of the most common technologies for sulfur recovery from acid gas streams. Important design criteria for the Claus unit, when part of an Integrated Gasification Combined Cycle (IGCC) power plant, are the ability to destroy ammonia completely and the ability to recover sulfur thoroughly from a relatively low purity acid gas stream without sacrificing flame stability. Because of these criteria, modifications to the conventional process are often required, resulting in a modified Claus process. For the studies discussed here, these modifications include the use of a 95% pure oxygen stream as the oxidant, a split flow configuration, and the preheating of the feeds with the intermediate pressure steam generated in the waste heat boiler (WHB). In the future, for IGCC plants with CO{sub 2} capture, the Claus unit must satisfy emission standards without sacrificing the plant efficiency in the face of typical disturbances of an IGCC plant, such as rapid change in the feed flow rates due to load-following and wide changes in the feed composition because of changes in the coal feed to the gasifier. The Claus unit should be adequately designed and efficiently operated to satisfy these objectives. Even though the Claus process has been commercialized for decades, most papers concerned with the modeling of the Claus process treat the key reactions as equilibrium reactions. Such models are validated by manipulating the temperature approach to equilibrium for a set of steady-state operating data, but they are of limited use for dynamic studies. One of the objectives of this study is to develop a model that can be used for dynamic studies. In a Claus process, especially in the furnace and the WHB, many reactions may take place. In this work, a set of linearly independent reactions has been identified, and kinetic models of the furnace flame and anoxic zones, WHB, and catalytic reactors have been developed. To facilitate the modeling of the Claus furnace, a four-stage method was devised so as to determine which set of linearly independent reactions would best describe the product distributions from available plant data. Various approaches are taken to derive the kinetic rate expressions, which are either missing in the open literature or found to be inconsistent. A set of plant data is used for optimal estimation of the kinetic parameters. The final model agrees well with the published plant data. Using the developed kinetics models of the Claus reaction furnace, WHB, and catalytic stages, two optimization studies are carried out. The first study shows that there exists an optimal steam pressure generated in the WHB that balances hydrogen yield, oxygen demand, and power generation. In the second study, it is shown that an optimal H{sub 2}S/SO{sub 2} ratio exists that balances single-pass conversion, hydrogen yield, oxygen demand, and power generation. In addition, an operability study has been carried out to examine the operating envelope in which both the H{sub 2}S/SO{sub 2} ratio and the adiabatic flame temperature can be controlled in the face of disturbances typical for the operation of an IGCC power plant with CO{sub 2} capture. Impact of CO{sub 2} capture on the Claus process has also been discussed.

20 FOSSIL-FUELED POWER PLANTS↗

SIESTA-SIPs: Massively parallel spectrum-slicing eigensolver for an ab initio molecular dynamics package

Integration of Shift-and-Invert Parallel spectral transformation (SIPs) eigensolver (as implemented in the SLEPc library) into an ab initio molecular dynamics package, SIESTA, is described. The effectiveness of the code is demonstrated on applications to polyethylene chains, boron nitride sheets, and bulk water clusters. For problems with the same number of orbitals, the performance of the SLEPc eigensolver depends on the sparsity of the matrices involved, favoring reduced dimensional systems such as polyethylene or boron nitride sheets in comparison to bulk systems like water clusters. For all problems investigated, performance of SIESTA-SIPs exceeds the performance of SIESTA with default solver (ScaLAPACK) at the larger number of cores and the larger number of orbitals. A method that improves the load-balance with each iteration in the self-consistency cycle by exploiting the emerging knowledge of the eigenvalue spectrum is demonstrated

ab initio↗

Dynamics stabilization and transport coherency in a rocking ratchet for cold atoms

Cold atoms in optical lattices have emerged as an ideal system to investigate the ratchet effect, as demonstrated by several recent experiments. In this work we analyze theoretically two aspects of ac-driven transport in cold-atom ratchets. We first address the issue of whether, and to what extent, an ac-driven ratchet for cold atoms can operate as a motor. We thus study theoretically a dissipative motor for cold atoms, as obtained by adding a load to a 1D nonadiabatically driven rocking ratchet. We demonstrate that a current can be generated also in the presence of a load, e.g., the ratchet device can operate as a motor. Correspondingly, we determine the stall force for the motor, which characterizes the range of loads over which the device can operate as a motor, and the differential mobility, which characterizes the response to a change in the magnitude of the load. Second, we compare our results for the transport in an ac-driven ratchet device with the transport in a dc-driven system. We observe a peculiar phenomenon: the double-harmonic ac force stabilizes the dynamics, allowing the generation of uniform directed motion over a range of momentum much larger than what is possible with a dc bias. We explain such a stabilization of the dynamics by observing that a nonadiabatic ac drive broadens the effective cooling momentum range and forces the atom trajectories to cover such a region. Thus the system can dissipate energy and maintain a steady-state energy balance. Our results show that in the case of a finite-range velocity-dependent friction, a ratchet device may offer the possibility of controlling the particle motion over a broader range of momentum with respect to a purely biased system, although this is at the cost of a reduced coherency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A fourth-order phase-field fracture model: Formulation and numerical solution using a continuous/discontinuous Galerkin method

Modeling crack initiation and propagation in brittle materials is of great importance to be able to predict sudden loss of load-carrying capacity and prevent catastrophic failure under severe dynamic loading conditions. Second-order phase-field fracture models have gained wide adoption given their ability to capture the formation of complex fracture patterns, e.g. via crack merging and branching, and their suitability for implementation within the context of the conventional finite element method. Higher-order phase-field models have also been proposed to increase the regularity of the exact solution and thus increase the spatial convergence rate of its numerical approximation. However, they require special numerical techniques to enforce the necessary continuity of the phase field solution. In this paper, we derive a fourth-order phase-field model of fracture in two independent ways; namely, from Hamilton’s principle and from a higher-order micromechanics-based approach. The latter approach is novel, and provides a physical interpretation of the higher-order terms in the model. In addition, we propose a continuous/discontinuous Galerkin (C/DG) method for use in computing the approximate phase-field solution. This method employs Lagrange polynomial shape functions to guarantee -continuity of the solution at inter-element boundaries, and enforces the required regularity with the aid of additional variational and interior penalty terms in the weak form. Finally, the phase-field equation is coupled with the momentum balance equation to model dynamic fracture problems in hyper-elastic materials. Two benchmark problems are presented to compare the numerical behavior of the C/DG method with mixed finite element methods.

42 ENGINEERING↗

Real-time Pricing Demand Response in Operations

Abstract—Dynamic pricing schemes have been implemented in commercial and industrial application settings, and recently they are getting attention for application to residential customers. Time-of-use and critical-peak-pricing rates are in place in various regions and are being piloted in many more. These programs are proving themselves useful for balancing energy during peak periods; however, real-time (5 minute) pricing signals combined with automation in end-use systems have the potential to deliver even more benefits to operators and consumers. Besides system peak shaving, a real-time pricing system can contribute demand response based on the locational marginal price of electricity, reduce load in response to a generator outage, and respond to local distribution system capacity limiting situations. The US Department of Energy (DOE) is teaming with a mid-west electricity service provider to run a distribution feeder-based retail electricity market that negotiates with residential automation equipment and clears every 5 minutes, thus providing a signal for lowering or raising electric consumption based on operational objectives of economic efficiency and reliability. This paper outlines the capability of the real-time pricing system and the operational scenarios being tested as the system is rolled-out starting in the first half of 2012.

Demand Response↗

Water and Nutrient Balances in a Large Tile-Drained Agricultural Catchment: A Distributed Modeling Study

This paper presents the development and implementation of a distributed model of coupled water nutrient processes, based on the representative elementary watershed (REW) approach, to the Upper Sangamon River Basin, a large, tile-drained agricultural basin located in central Illinois, mid-west of USA. Comparison of model predictions with the observed hydrological and biogeochemical data, as well as regional estimates from literature studies, shows that the model is capable of capturing the dynamics of water, sediment and nutrient cycles reasonably well. The model is then used as a tool to gain insights into the physical and chemical processes underlying the inter- and intra-annual variability of water and nutrient balances. Model predictions show that about 80% of annual runoff is contributed by tile drainage, while the remainder comes from surface runoff (mainly saturation excess flow) and subsurface runoff. It is also found that, at the annual scale nitrogen storage in the soil is depleted during wet years, and is supplemented during dry years. This carryover of nitrogen storage from dry year to wet year is mainly caused by the lateral loading of nitrate. Phosphorus storage, on the other hand, is not affected much by wet/dry conditions simply because the leaching of it is very minor compared to the other mechanisms taking phosphorous out of the basin, such as crop harvest. The analysis then turned to the movement of nitrate with runoff. Model results suggested that nitrate loading from hillslope into the channel is preferentially carried by tile drainage. Once in the stream it is then subject to in-stream denitrification, the significant spatio-temporal variability of which can be related to the variation of the hydrologic and hydraulic conditions across the river network.

54 ENVIRONMENTAL SCIENCES↗

Simulation of annual biogeochemical cycles of nutrient balance, phytoplankton bloom(s), and DO in Puget Sound using an unstructured grid model

Nutrient pollution from rivers, nonpoint source runoff, and nearly 100 wastewater discharges is a potential threat to the ecological health of Puget Sound with evidence of hypoxia in some basins. However, the relative contributions of loads entering Puget Sound from natural and anthropogenic sources, and the effects of exchange flow from the Pacific Ocean are not well understood. Development of a quantitative model of Puget Sound is thus presented to help improve our understanding of the annual biogeochemical cycles in this system using the unstructured grid Finite-Volume Coastal Ocean Model framework and the Integrated Compartment Model (CE-QUAL-ICM) water quality kinetics. Results based on 2006 data show that phytoplankton growth and die-off, succession between two species of algae, nutrient dynamics, and dissolved oxygen in Puget Sound are strongly tied to seasonal variation of temperature, solar radiation, and the annual exchange and flushing induced by upwelled Pacific Ocean waters. Concentrations in the mixed outflow surface layer occupying approximately 5–20 m of the upper water column show strong effects of eutrophication from natural and anthropogenic sources, spring and summer algae blooms, accompanied by depleted nutrients but high dissolved oxygen levels. The bottom layer reflects dissolved oxygen and nutrient concentrations of upwelled Pacific Ocean water modulated by mixing with biologically active surface outflow in the Strait of Juan de Fuca prior to entering Puget Sound over the Admiralty Inlet. The effect of reflux mixing at the Admiralty Inlet sill resulting in lower nutrient and higher dissolved oxygen levels in bottom waters of Puget Sound than the incoming upwelled Pacific Ocean water is reproduced. Finally, by late winter, with the reduction in algal activity, water column constituents of interest, were renewed and the system appeared to reset with cooler temperature, higher nutrient, and higher dissolved oxygen waters from the Pacific Ocean.

biogeochemical model, 3-D hydrodynamic model, nutr↗

Unnatural hypoxic regimes

Abstract Coastal hypoxia is increasing worldwide in response to human‐caused changes in global climate and biogeochemical cycles. In this paper, we view anthropogenic trends in coastal hypoxia through the lens of disturbance ecology and complexity theory. Complexity theory provides a framework for describing how estuaries and other coastal aquatic ecosystems respond to hypoxia by understanding feedback loops. Can it also be valuable in understanding how these ecosystems behave under shifting (i.e., unnatural) disturbance regimes? When viewed as a disturbance regime, shifts in the spatial (areal extent and fragmentation) and temporal (frequency and duration of events) characteristics of coastal hypoxia can be used to track changes into a non‐stationary future. Here, we consider options for increasing the resilience of coastal aquatic ecosystems to future, unnatural hypoxic regimes. To start, we define desirable states as ecosystems with long trophic chains and slow nutrient and carbon dynamics that produce many ecosystem services. We then work backward to describe circumstances dominated by positive feedbacks that can lead ecosystems toward an undesirable state (i.e., depauperate communities and chemically reduced sediments). Processes of degradation and recovery can be understood in the context of island biogeography whereby species diversity in habitats fragmented by hypoxia is determined by the balance between rapid local extinction, slow recolonization from the edges of hypoxic patches, and opportunities for ecological succession during between disturbance events. We review potential future changes associated with changing global climate and highlight ways to enhance coastal resilience. In addition to efforts to slow climate change, potential interventions include reduced nutrient and carbon loadings from rivers, restoration of aquatic vegetation, and managing for key species, including those that promote sediment oxygenation, that enhance water clarity, or that promote grazing on epiphytic algae through top‐down control.

54 ENVIRONMENTAL SCIENCES↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters: Preprint

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗