Calibration of a high resolution grating soft x-ray spectrometer

The calibration of the soft x-ray spectral response of a large radius of curvature, high resolution grating spectrometer (HRGS) with a back-illuminated charge-coupled device detector is reported. The instrument is cross-calibrated for the 10-50 A waveband at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) x-ray source with the EBIT calorimeter spectrometer. The HRGS instrument is designed for laser-produced plasma experiments and is important for making high dynamic range measurements of line intensities, line shapes, and x-ray sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning and benchmarking a 3D dosimetry system for clinical use

Purpose: A 3D dosimetry system is described which consists of two parts: a radiochromic plastic dosimeter PRESAGE (which responds to absorbed dose with a linear change in optical-density) and the Duke large-field-of-view optical-CT scanner (DLOS). The DLOS/PRESAGE system has recently been commissioned and benchmarked for clinical use and, in particular, for verification and commissioning of complex radiation treatments. Methods: DLOS commissioning involved determining the dynamic range, spatial resolution, noise, temporal, and other characteristics of the light source and imaging components. Benchmarking tests were performed on the combined DLOS/PRESAGE system to establish baseline dosimetric performance. The tests consisted of delivering simple radiation treatments to PRESAGE dosimeters, and comparing the measured 3D relative dose distributions with the known gold standard. The gold standard distribution was obtained from machine beam-data or the treatment planning system (TPS). All studies used standardized procedures to ensure consistency. Results: For commissioning, isotropic spatial resolution was submillimeter (MTF > 0.5 for frequencies of 1.5 lp/mm) and the dynamic range was {approx}60 dB. Flood field uniformity was within 10% and stable after 45 min of warm-up. Stray-light is small, due to telecentricity, but even the residual can be removed through deconvolution by a point-spread-function. For benchmarking, the mean 3D passing NDD (normalized dose distribution) rate (3%, 3mm, 5% dose threshold) over the benchmark data sets was 97.3% {+-} 0.6% (range 96%-98%), which is on par with other planar dosimeters used in external beam radiation therapy indicating excellent agreement. Noise was low at <2% of maximum dose (4-12 Gy) for 2 mm reconstructions. The telecentric design was critical to enabling fast imaging with minimal stray-light artifacts. Conclusions: This work presents the first comprehensive benchmarking of a 3D dosimetry system for clinical use. The DLOS/PRESAGE benchmark tests show consistently good agreement to simple known distributions. The system produces accurate isotropic 2 mm dose data over clinical volumes (e.g., 16 cm diameter phantoms, 12 cm height), in under 15 min. It represents a uniquely useful and versatile new tool for commissioning and verification of complex therapy treatments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Results of the LHC Longitudinal Density Monitor

The Large Hadron Collider (LHC) at CERN is the world's largest particle accelerator. It is designed to accelerate and collide protons or heavy ions up to the center-of-mass energies of 14 TeV. Knowledge of the longitudinal distribution of particles is important for various aspects of accelerator operation, in particular to check the injection quality and to measure the proportion of charge outside the nominally filled bunches during the physics periods. In order to study this so-called ghost charge at levels very much smaller than the main bunches, a longitudinal profile measurement with a very high dynamic range is needed. A new detector, the LHC Longitudinal Density Monitor (LDM) is a single-photon counting system measuring synchrotron light by means of an avalanche photodiode detector. The unprecedented energies reached in the LHC allow synchrotron light diagnostics to be used with both protons and heavy ions. A prototype was installed during the 2010 LHC run and was able to longitudinally profile the whole ring with a resolution close to the target of 50 ps. On-line correction for the effects of the detector deadtime, pile-up and afterpulsing allow a dynamic range of 105 to be achieved. First measurements with the LDM are presented here along with an analysis of its performance and an outlook for future upgrades.

43 PARTICLE ACCELERATORS↗

A Computer Model to Study the Response of Energetic Materials to a Range of Dynamic Loads

Over the past decade we developed a model to enable computer simulation of the mechanical and subsequent energetic response of explosives and propellants to mechanical insults such as impacts, perforations, drops, and falls. The model is embedded in computer simulation programs that solve the non-linear, large deformation equations of compressible solid and fluid flow in space and time. It is implemented as a user-defined model, which returns the updated stress tensor and composition that result from the simulation supplied strain tensor change. Although it is multi-phase, in that gas and solid species are present, it is single-velocity, in that the gas does not flow through the porous solid. More than 70 time-dependent variables are made available for additional analyses and plotting. The model encompasses a broad range of possible responses: mechanical damage with no energetic response, and a continuous spectrum of degrees of violence including delayed and prompt detonation. This work describes the basic workings of the model.

36 MATERIALS SCIENCE↗

Reliable and Repeatable Characterization of Optical Streak Cameras

Optical streak cameras are used as primary diagnostics for a wide range of physics and laser experiments at facilities such as the National Ignition Facility (NIF). To meet the strict accuracy requirements needed for these experiments, the systematic nonlinearities of the streak cameras (attributed to nonlinearities in the optical and electrical components that make up the streak camera system) must be characterized. In some cases the characterization information is used as a guide to help determine how experiment data should be taken. In other cases, the characterization data are applied to the raw data images to correct for the nonlinearities. In order to characterize an optical streak camera, a specific set of data is collected, where the response to defined inputs are recorded. A set of analysis software routines has been developed to extract information such as spatial resolution, dynamic range, and temporal resolution from this data set. The routines are highly automated, requiring very little user input and thus provide very reliable and repeatable results that are not subject to interpretation. An emphasis on quality control has been placed on these routines due to the high importance of the camera characterization information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Massively distributed fiber strain sensing using Brillouin lasing

Brillouin based distributed fiber sensors present a unique set of characteristics amongst fiber sensing architectures. They are able to measure absolute strain and temperature over long distances, with high spatial resolution, and very large dynamic range in off-the-shelf fiber. However, Brillouin sensors traditionally provide only modest sensitivity due to the weak dependence of the Brillouin frequency on strain and the high signal to noise ratio required to identify the resonance’s peak frequency to within a small fraction of its linewidth. Recently, we introduced a technique which substantially improves the precision of Brillouin fiber sensors by exciting a series of lasing modes in a fiber loop cavity that experience Brillouin amplification at discrete locations in the fiber. The narrow-linewidth and high intensity of the lasing modes enabled ultra-low noise Brillouin sensors with large dynamic range. However, our initial demonstration was only modestly distributed: measuring strain at 40, non-contiguous positions along a 400 m fiber. In this work, we greatly extend this methodology to enable fully distributed sensing at 1000 contiguous locations along 3.5 km of fiber—an order of magnitude increase in sensor count and range. This highly-multiplexed Brillouin fiber laser sensor provides a strain noise as low as 34 nɛ/√Hz and we analyze the limiting factors in this approach.

47 OTHER INSTRUMENTATION↗

Feasibility study of prompt gamma neutron activation for NDT measurement of moisture in stone and brick

The conservation of stone and brick architecture or sculpture often involves damage caused by moisture. The feasibility of a NDT method based on prompt gamma neutron activation (PGNA) for measuring the element hydrogen as an indication of water is being evaluated. This includes systematic characterization of the lithology and physical properties of seven building stones and one brick type used in the buildings of the Smithsonian Institution in Washington, D.C. To determine the required dynamic range of the NDT method, moisture-related properties were measured by standard methods. Cold neutron PGNA was also used to determine chemically bound water (CBW) content. The CBW does not damage porous masonry, but creates an H background that defines the minimum level of detection of damaging moisture. The CBW was on the order of 0.5% for all the stones. This rules out the measurement of hygric processes in all of the stones and hydric processed for the stones with fine scale pore-size distributions The upper bound of moisture content, set by porosity through water immersion, was on the order of 5%. The dynamic range is about 10–20. The H count rates were roughly 1–3 cps. Taking into account differences in neutron energies and fluxes and sample volume between cold PGNA and a portable PGNA instrument, it appears that it is feasible to apply PGNA in the field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fabrication of Six Degrees-of-Freedom Hexflex Positioner With Integrated Strain Sensing Using Nonlithographically Based Microfabrication

In this study, a process flow is described for the low cost, flexible fabrication of metal micro-electromechanical systems (MEMS) with high performance integrated sensing. The process is capable of producing new designs in ≈1 week at an average unit cost of <$1 k/device even at batch sizes of ≈1–10, with expected sensing performance limits of about 135 dB over a 10 kHz sensor bandwidth. This is a ≈20× reduction in cost, ≈25× reduction in time, and potentially >30× increase in sensing dynamic range over comparable state-of-the-art compliant nanopositioners. The nonlithographically based microfabrication (NLBM) process is uniquely suited to create high performance nanopositioning architectures which are customizable to the positioning requirements of a range of nanoscale applications. These can significantly reduce the cost of nanomanufacturing research and development, as well as accelerate the development of new processes and the testing of fabrication process chains without excess capital investment. A six degrees-of-freedom (6DOF) flexural nanopositioner with integrated sensing for all 6DOF was fabricated using the newly developed process chain. The fabrication process was measured to have ≈30 μ m alignment. Sensor arm, flexure, and trace widths of 150 μ m, 150 μ m, and 800 μ m, respectively, were demonstrated. Process capabilities suggest lower bounds of 25 μ m, 50 μ m, and 100 μ m, respectively. Dynamic range sensing of 52 dB was demonstrated for the nanopositioner over a 10 kHz sensor bandwidth. Improvements are proposed to approach sensor performance of about 135 dB over a 10 kHz sensor bandwidth.

42 ENGINEERING↗

Contributions of immunoaffinity chromatography to deep proteome profiling of human biofluids

Human biofluids, especially blood plasma or serum, hold great potential as the sources of potential biomarkers for various diseases; however, the enormous dynamic range of protein concentrations in biofluids represents a significant analytical challenge to detect promising low-abundance protein biomarkers. Over the last decade, various immunoaffinity chromatographic methods have been developed and routinely applied for separating low-abundance proteins from the high and moderate-abundance proteins, thus enabling more effective detection of low-abundance proteins. Herein, we review the advances of immunoaffinity separation methods and their contributions to the proteomics applications of different human biofluids. The limitations and future perspective of immunoaffinity separation methods are also discussed.

Environmental Molecular Sciences Laboratory↗

XAMPS Detectors Readout ASIC for LCLS

An ASIC for the readout of signals from X-ray Active Matrix Pixel Sensor (XAMPS) detectors to be used at the Linac Coherent Light Source (LCLS) is presented. The X-ray Pump Probe (XPP) instrument, for which the ASIC has been designed, requires a large input dynamic range on the order of 104 photons at 8 keV with a resolution of half a photon FWHM. Due to the size of the pixel and the length of the readout line, large input capacitance is expected, leading to stringent requirement on the noise optimization. Furthermore, the large number of pixels needed for a good position resolution and the fixed LCLS beam period impose limitations on the time available for the single pixel readout. Considering the periodic nature of the LCLS beam, the ASIC developed for this application is a time-variant system providing low-noise charge integration, filtering and correlated double sampling. In order to cope with the large input dynamic range a charge pump scheme implementing a zero-balance measurement method has been introduced. It provides an on chip 3-bit coarse digital conversion of the integrated charge. The residual charge is sampled using correlated double sampling into analog memory and measured with the required resolution. The first 64 channel prototype of the ASIC has been fabricated in TSMC CMOS 0.25 {micro}m technology. In this paper, the ASIC architecture and performances are presented.

43 PARTICLE ACCELERATORS↗

A 15GSa/s, 1.5GHz bandwidth waveform digitizing ASIC

The PSEC4 custom integrated circuit was designed for the recording of fast waveforms for use in large-area time-of-flight detector systems. The ASIC has been fabricated using the IBM-8RF 0.13 micron CMOS process. On each of 6 analog channels, PSEC4 employs a switched capacitor array (SCA) 256 samples deep, a ramp-compare ADC with 10.5 bits of DC dynamic range, and a serial data readout with the capability of region-of-interest windowing to reduce dead time. The sampling rate can be adjusted between 4 and 15 Gigasamples/second [GSa/s] on all channels and is servo-controlled on-chip with a low-jitter delay-locked loop (DLL). The input signals are passively coupled on-chip with a -3 dB analog bandwidth of 1.5 GHz. The power consumption in quiescent sampling mode is less than 50 mW/chip; at a sustained trigger and readout rate of 50 kHz the chip draws 100 mW. After fixed-pattern pedestal subtraction, the uncorrected integral non-linearity is 0.15% over an 750 mV dynamic range. With a linearity correction, a full 1 V signal voltage range is available.The sampling timebase has a fixed-pattern non-linearity with an RMS of 13%, which can be corrected for precision waveform feature extraction and timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Radiation-Hard 8-Channel 15-Bit 40-MSPS ADC for the ATLAS Liquid Argon Calorimeter Readout

The custom design of a radiation-hardened, 8-channel, 40-MSPS, 15-bit resolution, 14.2-bit dynamic range, 11.4-ENOB ADC data acquisition ASIC fabricated in a commercial 65-nm triple-well CMOS technology is presented. The ADC is developed for and integrates seamlessly into the readout system for the ATLAS liquid argon (LAr) calorimeter in the high-luminosity large hadron collider (HLLHC) upgrade at CERN, which will require a total of 364 936 ADC channels. A three-stage MDAC+SAR pipelined ADC architecture was designed to meet the physics requirements and scientific goals of the ATLAS experiment. The ADC is a fully self-contained data acquisition system that includes foreground calibration, digital data processing, digital control, and supporting circuitry. The measured performance shows the ADC achieves a competitive dynamic range and SNDR, and it meets or exceeds the ATLAS analog requirements. Radiation tolerance and scalability design considerations were implemented at the device-, circuit-, and system-level. Radiation-hardening-by-design techniques used include redundancy for digital circuits, the use of MiM capacitors, and a hybrid RC-DAC for the ADC core. The ADC ASIC was demonstrated to be robust against the effects of the intense radiation expected in the HL-LHC experimental environment.

DAQ↗

IONOSPHERIC POWER-SPECTRUM TOMOGRAPHY IN RADIO INTERFEROMETRY

A tomographic method is described to quantify the three-dimensional power spectrum of the ionospheric electron-density fluctuations based on radio-interferometric observations by a two-dimensional planar array. The method is valid for the first-order Born approximation and might be applicable in correcting observed visibilities for phase variations due to the imprint of the full three-dimensional ionosphere. It is shown that the ionospheric electron-density distribution is not the primary structure to model in interferometry, but rather its autocorrelation function or equivalently its power spectrum. An exact mathematical expression is derived that provides the three-dimensional power spectrum of the ionospheric electron-density fluctuations directly from a rescaled scattered intensity field and an incident intensity field convolved with a complex unit phasor that depends on the w-term and is defined on the full sky pupil plane. In the limit of a small field of view, the method reduces to the single phase-screen approximation. Tomographic self-calibration can become important in high-dynamic range observations at low radio frequencies with wide-field antenna interferometers because a three-dimensional ionosphere causes a spatially varying convolution of the sky, whereas a single phase screen results in a spatially invariant convolution. A thick ionosphere can therefore not be approximated by a single phase screen without introducing errors in the calibration process. By applying a Radon projection and the Fourier projection-slice theorem, it is shown that the phase-screen approach in three dimensions is identical to the tomographic method. Finally, we suggest that residual speckle can cause a diffuse intensity halo around sources due to uncorrectable ionospheric phase fluctuations in the short integrations, which could pose a fundamental limit on the dynamic range in long-integration images.

79 ASTRONOMY AND ASTROPHYSICS↗

Optically transduced MEMS magnetometer

MEMS magnetometers with optically transduced resonator displacement are described herein. Improved sensitivity, crosstalk reduction, and extended dynamic range may be achieved with devices including a deflectable resonator suspended from the support, a first grating extending from the support and disposed over the resonator, a pair of drive electrodes to drive an alternating current through the resonator, and a second grating in the resonator overlapping the first grating to form a multi-layer grating having apertures that vary dimensionally in response to deflection occurring as the resonator mechanically resonates in a plane parallel to the first grating in the presence of a magnetic field as a function of the Lorentz force resulting from the alternating current. A plurality of such multi-layer gratings may be disposed across a length of the resonator to provide greater dynamic range and/or accommodate fabrication tolerances.

47 OTHER INSTRUMENTATION↗

Hydrothermal synthesis of urchin-like Co{sub 3}O{sub 4} nanostructures and their electrochemical sensing performance of H{sub 2}O{sub 2}

Nanostructured tricobalt tetraoxide, Co{sub 3}O{sub 4}, was hydrothermally synthesized starting from cobalt dichloride hexahydrate (CoCl{sub 2}·6H{sub 2}O) and urea (H{sub 2}NCONH{sub 2}) as precursor and polyethylene glycol-400 (PEG-400) as a structure-directing agent. Uniform urchin-like nanostructures were hydrothermally obtained at 150 °C for 16 h, and the Co{sub 3}O{sub 4} morphology did not collapse after a subsequent calcination at 300 °C for 2 h. XRD measurements indicated that the average sizes of Co{sub 3}O{sub 4} particles prior and after heating at 300 °C are 64 and 44 nm, respectively. This material has been successfully used for the nanostructuration of screen-printed carbon electrodes (SPCEs) which were used for the sensitive electrochemical detection of hydrogen peroxide (H{sub 2}O{sub 2}). The sensor is endowed with a large dynamic range (0.1 to 50 µM) and a limit of detection of 0.145 µM. The as obtained results show that the Co{sub 3}O{sub 4} nanomaterial could be a candidate to be used as sensors for the detection of analytes. - Graphical abstract: The nanowires appear to have a common center and grow to the outside along the radial direction. - Highlights: • Nanostructured was hydrothermally prepared using PEG-400. • Uniform urchin-like Co{sub 3}O{sub 4} nanostructures were hydrothermally obtained. • X-ray diffraction showed a cubic structure after calcinations process. • Nanostructured Co{sub 3}O{sub 4} was used for the sensitive electrochemical detection of H{sub 2}O{sub 2.} • The sensor is endowed with a large dynamic range 0.1 to 50 µM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

1.5 nm fabrication of test patterns for characterization of metrological systems

Any metrology tool is only as good as it is calibrated. The characterization of metrology systems requires test patterns at a scale about ten times smaller than the measured features. The fabrication of patterns with linewidths down to 1.5 nm is described. The test sample was designed in such a way that the distribution of linewidths appears to be random at any location. This pseudorandom test pattern is used to characterize dimensional metrology equipment over its entire dynamic range by extracting the modulation transfer function of the system. The test pattern contains alternating lines of silicon and tungsten silicide, each according to its designed width. As a result, the fabricated test samples were imaged using a transmission electron microscope, a scanning electron microscope, and an atomic force microscope. (C) 2015 American Vacuum Society.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mach-Zehnder recording systems for pulsed power diagnostics

Fiber-optic transmission and recording systems, based on Mach-Zehnder modulators, have been developed and installed at the National Ignition Facility (NIF), and are being developed for other pulsed-power facilities such as the Z accelerator at Sandia, with different requirements. We present the design and performance characteristics for the mature analog links, based on the system developed for the Gamma Reaction History diagnostic at the OMEGA laser and at NIF. For a single detector channel, two Mach-Zehnders are used to provide high dynamic range at the full recording bandwidth with no gaps in the coverage. We present laboratory and shot data to estimate upper limits on the radiation effects as they impact recorded data quality. Finally, we will assess the technology readiness level for mature and developing implementations of Mach-Zehnder links for these environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A direct electron detector for time-resolved MeV electron microscopy

The introduction of direct electron detectors enabled the structural biology revolution of cryogenic electron microscopy. Direct electron detectors are now expected to have a similarly dramatic impact on time-resolved MeV electron microscopy, particularly by enabling both spatial and temporal jitter correction. Here in this paper, we report on the commissioning of a direct electron detector for time-resolved MeV electron microscopy. The direct electron detector demonstrated MeV single electron sensitivity and is capable of recording megapixel images at 180 Hz. The detector has a 15-bit dynamic range, better than 30-μm spatial resolution and less than 20 analogue-to-digital converter count RMS pixel noise. The unique capabilities of the direct electron detector and the data analysis required to take advantage of these capabilities are presented. The technical challenges associated with generating and processing large amounts of data are also discussed.

36 MATERIALS SCIENCE↗