Plasma-depleted holes, waves, and energized particles from high-altitude explosive plasma perturbation experiments

The results of high-explosive shaped charge experiments King Crab and Bubble Machines I and II, intended to perturb the ambient plasma and magnetic field, are discussed. The instrumentation was flown above an altitude of 460 km in March 1980 and 1981 and comprised a single-axis dipole electric field detector, a fixed bias cylindrical Langmuir probe, a three-axis attitude magnetometer, and curved plated energetic ion and electron electrostatic analyzer. Among the effects of the explosion which are detailed, emphasis is placed on the creation of an ion-depleted dark hole during the Bubble Machine II experiment; mechanisms explaining the phenomenon are outlined. The auroral intensity ion beams with energies of up to 6.8 keV, observed following the explosion in the field-aligned ion electrostatic analyzer, are suggested to represent an existing ion conic population pitch angle scattered by the released barium into the view of the detector.

Wescott, E. M.↗

Plasma Waves Observed During CUSP Energetic Particle Events and Their Correlation With Polar and Akebono Satellite and Ground Data

We present Polar plasma wave data during cusp energetic particle (CEP) events at 6-9 R(sub E). These data suggest the presence of coherent electrostatic structures that are highly localized and that have typical velocities on the order of hundreds to thousands of kilometers per second along the ambient magnetic field. Some of the wave signatures are solitary waves and some are wave packets. The Polar wave instrument also provides evidence that some of the bursts of electromagnetic waves (with frequencies of a few hundred Hz and just below the electron cyclotron frequency around 800 Hz to 1-2 kHz) that are observed are coher&nt and propagating both up and down the field lines. Electron cyclotron harmonic (ECH) waves are often detected but their duration is usually short (less than 1 second). Low Frequency (less than 1 kHz), broadband, bursty electromagnetic waves are also present. The Polar wave data results are used to obtain a better understanding of the macro/microphysics during a CEP event that takes place on September 11, 1996, by correlating various Polar (approximately 7.0 R(sub E)) and Akebono (approximately 1.4 R(sub E)) data while both spacecraft are in or near the cusp/cleft region and nearly on the same field line, and magnetometer data from the Canadian Intermagnet and Canopus ground stations, which lie near the base of the magnetic footprint passing through Polar. Solar wind and magnetic field data from the interplanetary medium and magnetosheath are provided by the Geotail and IMP-8 satellites, respectively. Some of the cusp waves may be indicators of the reconnection process taking place through the cusp, the result of mixing of magnetosheath with magnetospheric plasma, and the consequence of an anisotropic electron population in a depressed magnetic field. The low frequency electromagnetic waves are still under study to determine their role, if any, in the heating and acceleration of the MeV He ions during CEP events.

Pickett, J. S.↗

Electrostatic forces for personnel restraints

The feasibility of utilizing electrostatic forces for personnel retention devices on exterior spacecraft surfaces was analyzed. The investigation covered: (1) determination of the state of the art; (2) analysis of potential adhesion surfaces; (3) safety considerations for personnel; (4) electromagnetic force field determination and its effect on spacecraft instrumentation; and (5) proposed advances to current technology based on documentation review, analyses, and experimental test data.

Ashby, N.↗

Detectability of electrostatic decay products in Ulysses and Galileo observations of type 3 solar radio sources

Recent in situ Ulysses and Galileo observations of the source regions of type 3 solar radio bursts appear to show an absence of ion acoustic waves S produced by nonlinear Langmuir wave processes such as the electrostatic (ES) decay, in contradiction with earlier ISEE 3 observations and analytic theory. This letter resolves these apparent contradictions. Refined analyses of the maximum S-wave electric fields produced by ES decay and of the characteristics of the Ulysses Wave Form Analyzer (WFA) instrument show that the bursty S waves observed by the ISEE 3 should be essentially undetectable by the Ulysses WFA. It is also shown that the maximum S-wave levels predicted for the Galileo event are approximately less than the instrumental noise level, thereby confirming an earlier suggestion. Thus, no contradictions exist between the ISEE 3 and Ulysses/Galileo observation, and no evidence exists against ES decay in the published Ulysses and Galileo data. All available data are consistent with, or at worst not inconsistent with, the ES decay proceeding and being the dominant nonlinear process in type 3 bursts.

Cairns, Iver H.↗

Post-Launch Calibration and Testing of Space Weather Instruments on GOES-R Satellite

The Geostationary Operational Environmental Satellite - R (GOES-R) is the first of a series of satellites to be launched, with the first launch scheduled for October 2016. The three instruments - Solar Ultra Violet Imager (SUVI), Extreme ultraviolet and X-ray Irradiance Sensor (EXIS), and Space Environment In-Situ Suite (SEISS) provide the data needed as inputs for the product updates National Oceanic and Atmospheric Administration (NOAA) provides to the public. SUVI is a full-disk extreme ultraviolet imager enabling Active Region characterization, filament eruption, and flare detection. EXIS provides inputs to solar backgrounds/events impacting climate models. SEISS provides particle measurements over a wide energy-and-flux range that varies by several orders of magnitude and these data enable updates to spacecraft charge models for electrostatic discharge. EXIS and SEISS have been tested and calibrated end-to-end in ground test facilities around the United States. Due to the complexity of the SUVI design, data from component tests were used in a model to predict on-orbit performance. The ground tests and model updates provided inputs for designing the on-orbit calibration tests. A series of such tests have been planned for the Post-Launch Testing (PLT) of each of these instruments, and specific parameters have been identified that will be updated in the Ground Processing Algorithms, on-orbit parameter tables, or both. Some of SUVI and EXIS calibrations require slewing them off the Sun, while no such maneuvers are needed for SEISS. After a six-month PLT period the GOES-R is expected to be operational. The calibration details are presented in this paper.

On-orbit Calibration↗

Post-Launch Calibration and Testing of Space Weather Instruments on GOES-R Satellite

The Geostationary Operational Environmental Satellite - R (GOES-R) is the first of a series of satellites to be launched, with the first launch scheduled for October 2016. The three instruments Solar UltraViolet Imager (SUVI), Extreme ultraviolet and X-ray Irradiance Sensor (EXIS), and Space Environment In-Situ Suite (SEISS) provide the data needed as inputs for the product updates National Oceanic and Atmospheric Administration (NOAA) provides to the public. SUVI is a full-disk extreme ultraviolet imager enabling Active Region characterization, filament eruption, and flare detection. EXIS provides inputs to solar back-ground-sevents impacting climate models. SEISS provides particle measurements over a wide energy-and-flux range that varies by several orders of magnitude and these data enable updates to spacecraft charge models for electrostatic discharge. EXIS and SEISS have been tested and calibrated end-to-end in ground test facilities around the United States. Due to the complexity of the SUVI design, data from component tests were used in a model to predict on-orbit performance. The ground tests and model updates provided inputs for designing the on-orbit calibration tests. A series of such tests have been planned for the Post-Launch Testing (PLT) of each of these instruments, and specific parameters have been identified that will be updated in the Ground Processing Algorithms, on-orbit parameter tables, or both. Some of SUVI and EXIS calibrations require slewing them off the Sun, while no such maneuvers are needed for SEISS. After a six-month PLT period the GOES-R is expected to be operational. The calibration details are presented in this paper.

On-orbit Calibration↗

Instrumentation and Methodology Development for Mars Mission

The Mars environment comprises a dry, cold and low air pressure atmosphere with low gravity (0.38g) and high resistivity soil. The global dust storms that cover a large portion of Mars were observed often from Earth. This environment provides an idea condition for triboelectric charging. The extremely dry conditions on the Martian surface have raised concerns that electrostatic charge buildup will not be dissipated easily. If triboelectrically generated charge cannot be dissipated or avoided, then dust will accumulate on charged surfaces and electrostatic discharge may cause hazards for future exploration missions. The low surface temperature on Mars helps to prolong the charge decay on the dust particles and soil. To better understand the physics of Martian charged dust particles is essential to future Mars missions. We research and design two sensors, velocity/charge sensor and PZT momentum sensors, to detect the velocity distribution, charge distribution and mass distribution of Martian charged dust particles. These sensors are fabricated at NASA Kenney Space Center, Electromagnetic Physics Testbed. The sensors will be tested and calibrated for simulated Mars atmosphere condition with JSC MARS-1 Martian Regolith simulant in this NASA laboratory.

Chen, Yuan-Liang Albert↗

A rocket-borne electrostatic analyzer for measurement of energetic particle flux

A rocket-borne electrostatic analyzer experiment is described. It is used to measure energetic particle flux (0.9 to 14 keV) in the nighttime midlatitude E region. Energetic particle precipitation is believed to be a significant nighttime ionization source, particularly during times of high geomagnetic activity. The experiment was designed for use in the payload of a Nike Apache sounding rocket. The electrostatic analyzer employs two cylindrical parallel plates subtending a central angle of 90 deg. The voltage waveform supplied to the plates is a series of steps synchronized to the spin of the payload during flight. Both positive and negative voltages are provided, extending the detection capabilities of the instrument to both electrons and protons (and positive ions). The development, construction and operation of the instrument is described together with a preliminary evaluation of its performance in a rocket flight.

Pozzi, M. A.↗

STS-40 orbital acceleration research experiment flight results during a typical sleep period

The Orbital Acceleration Research Experiment (OARE), an electrostatic accelerometer package with complete on-orbit calibration capabilities, was flown for the first time aboard the Space Shuttle on STS-40. This is also the first time an accelerometer package with nano-g sensitivity and a calibration facility has flown aboard the Space Shuttle. The instrument is designed to measure and record the Space Shuttle aerodynamic acceleration environment from the free molecule flow regime through the rarified flow transition into the hypersonic continuum regime. Because of its sensitivity, the OARE instrument defects aerodynamic behavior of the Space Shuttle while in low-earth orbit. A 2-hour orbital time period on day seven of the mission, when the crew was asleep and other spacecraft activities were at a minimum, was examined. During the flight, a 'trimmed-mean' filter was used to produce high quality, low frequency data which was successfully stored aboard the Space Shuttle in the OARE data storage system. Initial review of the data indicated that, although the expected precision was achieved, some equipment problems occurred resulting in uncertain accuracy. An acceleration model which includes aerodynamic, gravity-gradient, and rotational effects was constructed and compared with flight data. Examination of the model with the flight data shows the instrument to be sensitive to all major expected low frequency acceleration phenomena; however, some erratic instrument bias behavior persists in two axes. In these axes, the OARE data can be made to match a comprehensive atmospheric-aerodynamic model by making bias adjustments and slight linear corrections for drift. The other axis does not exhibit these difficulties and gives good agreement with the acceleration model.

Blanchard, R. C.↗

A source of plasma turbulence at the ionopause of Venus

The microscopic aspects of the interaction of the solar wind with the ionosphere of Venus are explored, in light of simultaneous suprathermal ion and low frequency electric field signal measurements by Pioneer Venus instruments which suggest that the two ionopause phenomena may be causally related. Both parallel and perpendicular propagating waves are examined for instability, in the presence of planetary ions added to the flowing ionosheath plasma, by linear Vlasov theory. While for the low beta plasma conditions of the ionopause neither electrostatic nor electromagnetic parallel propagating waves are found to be unstable, perpendicular propagating electrostatic waves are unstable and have the proper frequency-wavelength relation to be Doppler shifted into the observed 100-Hz channel.

Daniell, R. E., Jr.↗

Rocket-borne particle, field, and plasma observations in the cleft region

Results are reported for comprehensive observations of magnetic and electric fields together with ambient and suprathermal plasmas above the dayside auroral oval with rocket-borne instrumentation which penetrated the cleft region. Measurements were also obtained equatorward and poleward of the cleft. Convection velocities as inferred from electric-field measurements were generally toward noon equatorward of the cleft and were antisunward over the polar cap. Observations of electron temperatures, electric fields, and low-frequency electrostatic noise provide strong evidence of a plasma instability (Farley-Buneman) in the E-layer associated with the appearance of the 'slant E condition' identified in ground-acquired ionograms. The positions of these measurements relative to that of the cleft were firmly established via the determination of the plasma environment with an electrostatic analyzer.

Ungstrup, E.↗

The electron spectrometer experiment on ISEE-1

A six-axis electron spectrometer for the ISEE-1 spacecraft is described and some typical early results presented. This instrument, designed for three-dimensional plasma distribution function studies in the solar wind, magnetosheath, outer magnetosphere, and near tail regions, has three energy ranges: 7.5-512 eV, 11-2062 eV, and 109-7285 cV, respectively. Two channel electron multipliers are used at the output of each of six cylindrical electrostatic analyzers. The total mass of two sensors and a data processing unit is 4.9 kg and the power comsumption is 3.5 W. Two hundred information bits/s telemetry rate is required.

Ogilvie, K. W.↗

Observations of the plasma environment during an active ionospheric ion beam

This paper presents detailed data on positive ion flux observations acquired during an active rocket-borne ion beam injection experiment, using the hemispheric electrostatic energy and pitch angle spectrometer (HEEPS) which was separated from the beam-emitting payload by distances along and across geomagnetic field lines which varied systematically during the experiment. The data obtained by the HEEPS illustrate a number of outstanding features of the ion flux environment near the HEEPS instrument during beam operations, some of which are not understood. It is shown that particle, field, and photometric data support a picture of particularly intense beam-plasma interactions in the immediate vicinity of the beam-emitting payload.

Pollock, C. J.↗

MEMS Louvers for Thermal Control

Mechanical louvers have frequently been used for spacecraft and instrument thermal control purposes. These devices typically consist of parallel or radial vanes, which can be opened or closed to vary the effective emissivity of the underlying surface. This project demonstrates the feasibility of using Micro-Electromechanical Systems (MEMS) technology to miniaturize louvers for such purposes. This concept offers the possibility of substituting the smaller, lighter weight, more rugged, and less costly MEMS devices for such mechanical louvers. In effect, a smart skin that self adjusts in response to environmental influences could be developed composed of arrays of thousands of miniaturized louvers. Several orders of magnitude size, weight, and volume decreases are potentially achieved using micro-electromechanical techniques. The use of this technology offers substantial benefits in spacecraft/instrument design, integration and testing, and flight operations. It will be particularly beneficial for the emerging smaller spacecraft and instruments of the future. In addition, this MEMS thermal louver technology can form the basis for related spacecraft instrument applications. The specific goal of this effort was to develop a preliminary MEMS device capable of modulating the effective emissivity of radiators on spacecraft. The concept pursued uses hinged panels, or louvers, in a manner such that heat emitted from the radiators is a function of louver angle. An electrostatic comb drive or other such actuator can control the louver position. The initial design calls for the louvers to be gold coated while the underlying surface is of high emissivity. Since, the base MEMS material, silicon, is transparent in the InfraRed (IR) spectrum, the device has a minimum emissivity when closed and a maximum emissivity when open. An initial set of polysilicon louver devices was designed at the Johns Hopkins Applied Physics Laboratory in conjunction with the Thermal Engineering Branch at NASA's Goddard Space Flight Center.

Champion, J. L.↗

Improved Detection System Description and New Method for Accurate Calibration of Micro-Channel Plate Based Instruments and Its Use in the Fast Plasma Investigation on NASA's Magnetospheric MultiScale Mission

The Fast Plasma Investigation (FPI) on NASAs Magnetospheric MultiScale (MMS) mission employs 16 Dual Electron Spectrometers (DESs) and 16 Dual Ion Spectrometers (DISs) with 4 of each type on each of 4 spacecraft to enable fast (30 ms for electrons; 150 ms for ions) and spatially differentiated measurements of the full 3D particle velocity distributions. This approach presents a new and challenging aspect to the calibration and operation of these instruments on ground and in flight. The response uniformity, the reliability of their calibration and the approach to handling any temporal evolution of these calibrated characteristics all assume enhanced importance in this application, where we attempt to understand the meaning of particle distributions within the ion and electron diffusion regions of magnetically reconnecting plasmas. Traditionally, the micro-channel plate (MCP) based detection systems for electrostatic particle spectrometers have been calibrated using the plateau curve technique. In this, a fixed detection threshold is set. The detection system count rate is then measured as a function of MCP voltage to determine the MCP voltage that ensures the count rate has reached a constant value independent of further variation in the MCP voltage. This is achieved when most of the MCP pulse height distribution (PHD) is located at higher values (larger pulses) than the detection system discrimination threshold. This method is adequate in single-channel detection systems and in multi-channel detection systems with very low crosstalk between channels. However, in dense multi-channel systems, it can be inadequate. Furthermore, it fails to fully describe the behavior of the detection system and individually characterize each of its fundamental parameters. To improve this situation, we have developed a detailed phenomenological description of the detection system, its behavior and its signal, crosstalk and noise sources. Based on this, we have devised a new detection system calibration method that enables accurate and repeatable measurement and calibration of MCP gain, MCP efficiency, signal loss due to variation in gain and efficiency, crosstalk from effects both above and below the MCP, noise margin, and stability margin in one single measurement. More precise calibration is highly desirable as the instruments will produce higher quality raw data that will require less post-acquisition data correction using results from in-flight pitch angle distribution measurements and ground calibration measurements. The detection system description and the fundamental concepts of this new calibration method, named threshold scan, will be presented. It will be shown how to derive all the individual detection system parameters and how to choose the optimum detection system operating point. This new method has been successfully applied to achieve a highly accurate calibration of the DESs and DISs of the MMS mission. The practical application of the method will be presented together with the achieved calibration results and their significance. Finally, it will be shown that, with further detailed modeling, this method can be extended for use in flight to achieve and maintain a highly accurate detection system calibration across a large number of instruments during the mission.

detection system↗

The MECA Payload as a Dust Analysis Laboratory on the MSP 2001 Lander

In a companion abstract, the "Mars Environmental Compatibility Assessment" (MECA) payload for Mars Surveyor Program 2001 (MSP 2001) is described in terms of its capabilities for addressing exobiology on Mars. Here we describe how the same payload elements perform in terms of gathering data about surface dust on the planet. An understanding of the origin and properties of dust is important to both human exploration and planetary geology. The MECA instrument is specifically designed for soil/dust investigations: it is a multifunctional laboratory equipped to assess particulate properties with wet chemistry, camera imagery, optical microscopy (potentially with LTV fluorescence capability), atomic force microscopy (AFM; potentially with mineral-discrimination capabilities), electrometry, active & passive external materials-test panels, mineral hardness testing, and electrostatic & magnetic materials testing. Additionally, evaluation of soil chemical and physical properties as a function of depth down to about 50 cm will be facilitated by the Lander/MECA robot arm on which the camera (RAC) and electrometer are mounted. Types of data being sought for the dust include: (1) general textural and grain-size characterization of the soil as a whole --for example, is the soil essentially dust with other components or is it a clast-supported material in which dust resides only in the clast interstices, (2) size frequency distribution for dust particles in the range 0.01 to 10.00 microns, (3) particle-shape distribution of the soil components and of the fine dust fraction in particular, (4) soil fabric such as grain clustering into clods, aggregates, and cemented/indurated grain amalgamations, as well as related porosity, cohesiveness, and other mechanical soil properties, (5) cohesive relationship that dust has to certain types of rocks and minerals as a clue to which soil materials may be prime hosts for dust "piggybacking", (6) particle, aggregate, and bulk soil electrostatic properties, (7) particle hardness, (8) particle magnetic properties, (9) bulk dust geochemistry (solubility, reactivity, ionic and mineral species). All of these quantities are needed in order for the human exploration program to make assessments of hazards on Mars, and to better enable the production on earth, of soil/dust simulants that can act as realistic test materials in terms of those properties that render dust a contaminant.Such properties include the small grain size that enables penetration of space-suit joints, mechanical interfaces and bearings, seals, etc., and presents difficulty for filtration systems. Size also plays a critical role in the potential for lung disease in long-term habitats. The properties of grain shape and hardness are important parameters in determining the abrasiveness of dust as it enters mechanical systems, or bombards helmet visors and habitat windows in dust-laden winds. Adhesive electrostatic and magnetic properties of dust will be prime causes of contamination of space suits and equipment. Contamination causes mechanical malfunction, tracking of dirt into habitats, "piggybacking" of toxins on dust into habitats, changes in albedo and efficiency of solar arrays and heat exchangers, and changes in electrical conductivity of suit surfaces and other materials that may have specific safety requirements regarding electrical conductivity. Other potentially hazardous properties of dust include the possibility of high solubility of some component grains (rendering them reactive), and toxicity of some materials --grains of superoxidants and heavy metals (there is always the slim, but not inconceivable possibility of biogenic components such as spores). Because Mars has no active surface aqueous regime, volcanic emissions, meteoritic debris, weathering products, and photochemical products of Mars have nowhere to go except reside in the surface; there are few mechanical or chemical (buffering) processes to remove the accumulation of eons. From a planetology perspective, there are many enigmatic issues relating to dust and the aeolian regime in general. MECA will be able to address many questions in this area. For example, if MECA determines a particular particle size distribution (size and sorting values), it will be possible to make inferences about the origin of the dust - - is it all aeolian, or a more primitive residue of weathering, volcanic emissions, and meteoritic gardening? Trenching with the Lander/MECA robot arm will enable local stratigraphy to be determined in terms of depositional rates, amounts and cyclicity in dust storms and/or local aeolian transport. Grain shape will betray the origin of the dust fragments as being the product of recent or ancient weathering, or the comminution products of aeolian transport --the dust-silt ratio might be a measure of aeolian comminution energy. Additional information is contained in the original.

Marshall, J.↗

Experiment M403: Electrostatic charge

Experiment M403 was flown on the Gemini 4 and 5 spacecraft in an effort to discover whether the spacecraft could accumulate sufficient excess electric charge to constitute a hazard for later Gemini-Agena rendezvous missions. An attempt was made to measure the electric field terminating on a small area of the spacecraft retrograde adapter section and to calculate the total spacecraft charge from this measured field value. The Gemini 5 instrument was inhibited from responding to electric fields that corresponded to a charge on the spacecraft. However, readings were obtained on the Gemini 5 mission that were of as great or greater magnitude than those obtained on the Gemini 4 mission. This could be interpreted as an indication that the contribution of a net spacecraft charge to the Gemini 4 measurements was negligible. An operational measurement that was performed on a later rendezvous mission was indicative of a very small exchange of charge between the Gemini spacecraft and the Agena vehicle.

Lafferty, P. E.↗

Advanced Engraving Of Angle-Encoder Disks

Precision increased over mechanical engravers. Laser pulses timed according to rotational speed of rotor electrostatically suspended in vacuum marks angular-encoder disk mounted on lower end of rotor. Precision of timing circuitry and low rotational damping (damping time about 700 years in high vacuum) results in highly-precise angular intervals. System conceived to meet need for increased precision of angular measurements in advanced scientific instruments.

Polstorff, Walter K.↗