Search NASA⌕ Search

SEARCH · Search NASA

Results for “Element removal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A Review of the Proposed K (sub Isi) Offset-Secant Method for Size-Independent Linear-Elastic Toughness Evaluation

The proposed size-independent linear-elastic fracture toughness, K (sub Isi), for potential inclusion in ASTM E399 targets a consistent 0.5 millimeters crack extension for all specimen sizes through an offset secant that is a function of the specimen ligament length. The K (sub Isi) method also includes an increase in allowable deformation, and the removal of the P (sub max)/P (sub Q) criterion. A finite element study of the K (sub Isi) test method confirms the viability of the increased deformation limit, but has also revealed a few areas of concern. Findings: 1. The deformation limit, b (sub o) greater than or equal to 1.1 times (K (sub I) divided by delta (sub ys) squared) maintains a K-dominant crack tip field with limited plastic contribution to the fracture energy; 2. The three dimensional effects on compliance and the shape of the force versus CMOD (Crack-Mouth Opening Displacement) trace are significant compared to a plane strain assumption; 3. The non-linearity in the force versus CMOD trace at deformations higher than the current limit of 2.5 times (K (sub I) divided by delta (sub ys) squared) is sufficient to introduce error or even "false calls" regarding crack extension when using a constant offset secant line. This issue is more significant for specimens with W (width) greater than or equal to 2 inches; 4. A non-linear plasticity correction factor in the offset secant may improve the viability of the method at deformations between 2.5 times (K (sub I) divided by delta (sub ys) squared) and 1.1 times (K (sub I) divided by delta (sub ys) squared).

James, Mark↗

Safety Compliance Verification of Fuel Cell Electric Vehicle Exhaust

NREL has been developing compliance verification tools for allowable hydrogen levels prescribed by the Global Technical Regulation Number 13 (GTR-13) for hydrogen fuel cell electric vehicles (FCEVs). As per GTR-13, FCEV exhaust is to remain below 4 vol% H2 over a 3-second moving average and shall not at any time exceed 8 vol% H2 and that this requirement is to be verified with an analyzer that has a response time of less than 300 ms. To be enforceable, a means to verify regulatory requirements must exist. In response to this need, NREL developed a prototype analyzer that meets the GTR metrological requirements for FCEV exhaust analysis. The analyzer was tested on a commercial fuel cell electric vehicle (FCEV) under simulated driving conditions using a chassis dynamometer at the Emissions Research and Measurement Section of Environment and Climate Change Canada and FCEV exhaust was successfully profiled. Although the prototype FCEV Exhaust Analyzer met the metrological requirements of GTR-13, the stability of the hydrogen sensor was adversely impacted by condensed water in the sample gas. FCEV exhaust is at an elevated temperature and nearly saturated with water vapor. Furthermore, condensed water is present in the form of droplets. Condensed water in the sample gas can collect on the hydrogen sensing element, which would not only block access of hydrogen to the sensor but can also permanently damage the sensor. In the past year, the design of the gas sampling system was modified to mitigate against the transport of liquid water to the sensing element. Laboratory testing confirmed the effectiveness of the modified sampling system water removal strategy while maintaining the measurement range and response time required by GTR-13. Testing of the upgraded analyzer design on an FCEV operating on a chassis dynamometer is scheduled for the summer of 2021.

DIRECT ENERGY CONVERSION,HYDROGEN↗

The adverse aerodynamic impact of very small leading-edge ice (roughness) buildups on wings and tails

Systematic experimental studies were performed to establish the aerodynamic impact of very small leading-edge simulated ice (roughness) formations on lifting surfaces. The geometries studied include single element configurations (airfoil and 3-D tail) as well as multi-element high-lift airfoil geometries. Emphasis in these studies was placed on obtaining results at high Reynolds numbers to insure the applicability of the findings to full-scale situations. It was found that the well-known Brumby correlation for the adverse lift impact of discrete roughness elements at the leading edge is not appropriate for cases representative of initial ice build up (i.e., distributed roughness). It was also found that allowing initial ice formations of a size required for removal by presently proposed deicing systems could lead to maximum lift losses of approximately 40 percent for single-element airfoils. Losses in angle-of-attack margin to stall are equally substantial - as high as 6 degrees. Percentage losses for multi-element airfoils are not as severe as for single-element configurations, but degradations of the angle-of-attack-to-stall margin are the same for both.

Lynch, Frank T.↗

Removal of Non-Specifically Bound Proteins Using Rayleigh Waves Generated on ST-Quartz Substrates

Label-free biosensors are plagued by the issue of non-specific protein binding which negatively affects sensing parameters such as sensitivity, selectivity, and limit-of-detection. In the current work, we explore the possibility of using the Rayleigh waves in ST-Quartz devices to efficiently remove non-specifically bound proteins via acoustic streaming. A coupled-field finite element (FE) fluid structure interaction (FSI) model of a surface acoustic wave (SAW) device based on ST-Quartz substrate in contact with a liquid loading was first used to predict trends in forces related to SAW-induced acoustic streaming. Based on model predictions, it is found that the computed SAW body force is sufficient to overcome adhesive forces between particles and a surface while lift and drag forces prevent reattachment for a range of SAW frequencies. We further performed experiments to validate the model predictions and observe that the excitation of Rayleigh SAWs removed non-specifically bound (NSB) antigens and antibodies from sensing and non-sensing regions, while rinsing and blocking agents were ineffective. An amplified RF signal applied to the device input disrupted the specific interactions between antigens and their capture antibody as well. ST-quartz allows propagation of Rayleigh and leaky SH-SAW waves in orthogonal directions. Thus, the results reported here could allow integration of three important biosensor functions on a single chip, i.e., removal of non-specific binding, mixing, and sensing in the liquid phase.

59 BASIC BIOLOGICAL SCIENCES↗

Significance of a Solid Electrolyte Interphase on Separation of Anode and Cathode Materials from Spent Li-Ion Batteries by Froth Flotation

The separation of electrode active materials from spent Li-ion batteries (LIBs) by froth flotation is challenging due to the changes in surface properties of electrode active materials from cycling as well as the presence of organic binders. In this work, the froth flotation separation of aged anode and cathode composite materials from spent LIBs was systematically investigated after the materials were heat treated. The results show that aged anode and cathode materials from spent LIBs can be well separated from each other after a heating process in air at 400 degrees C and at which some of the PVDF binder remains intact. The underlying mechanism was investigated by X-ray photoelectron spectroscopy (XPS), contact angle measurements, and scanning transmission electron microscopy (STEM) coupled with energy-dispersive X-ray spectroscopy (EDX). The results from the XPS and contact angle measurements show that there is a hydrophilic and oxygen-rich layer on the surface of aged anode materials. This hydrophilic surface, associated with the solid electrolyte interface (SEI) layer, impacts the froth flotation process significantly. The results also show that both the SEI layers and PVDF binder residues on the surface are removed at 400 degrees C for an hour, restoring the hydrophobicity of the anode materials, which, in turn, benefits the separation of anode and cathode materials. The STEM/EDX elemental analysis data confirms that there are 20 nm-thick oxygen-rich SEI layers on the surfaces, which can be removed after a heating process. The present result illustrates the significance of the SEI layers in flotation separation of electrode materials and sheds new lights into the future development of the recycling processes for the separation of anode and cathode composite materials from spent Li-ion batteries.

25 ENERGY STORAGE↗

Selective pseudocapacitive immobilization of REE elements on carbon based electrodes

Current extraction technologies for rare earth elements at ambient conditions are reagent and energy intensive, giving rise to significant quantities of secondary waste streams. Exploration of the removal of common cations from aqueous streams has been undertaken with carbon materials and have shown promising results. However, those promising materials have not been explored extensively for rare earth element capture from aqueous process streams. In this study, a carbon electrode was investigated for the adsorption and immobilization of REE elements from aqueous solutions. Cyclic voltammetry studies of the carbon electrode displayed a pseudocapacitive behavior where it was verified that cation adsorption is accompanied by an electron transfer process. Preliminary tests showed that a current density of 89.1 mA. g -1 , allowed for the pseudocapacitive adsorption (PSA) of Nd 3+ cation without the formation of rare earth hydroxides. Hence, the selective PSA of Nd 3+ was verified in an electrolyte solution with equimolar concentrations of Nd 3+ , Mg 2+ , Li + , Na + and K + , achieving separation factors of 8.6, 1.1, and 10.9 for Nd 3+ /Li + , Nd 3+ /Na + , and Nd 3+ /Mg 2+ , respectively. Analysis of the potential-time curves for the various cations suggests that storage of ions in the electrode involved pore-spacings rather than interlayer spacings and was corroborated by XRD analysis. Specific capacitance as high as >640 F.g -1 for Nd 3+ was also observed for the carbon electrode, with Faradaic efficiencies (FE) of > 20% for Nd 3+ and Mg 2+ , and > 9% for Na + . Furthermore, adsorption capacity of >125 mg g -1 after 4hrs of electrosorption was observed for Nd 3+ . In the presence of the Nd 3+ electrolyte, the electrode achieved increasing storage of Nd 3+ with >94% retention of Nd 3+ with a FE > 20% over 6 cycles between loading and releases in 1 M KCl solution. In conclusion, these preliminary results provide information and some guidance on the selective recovery of rare earth elements, such as Nd, in aqueous streams in the presence of competitive cations employing the use of carbon-based materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Compression creep of filamentary composites

Axial and transverse strain fields induced in composite laminates subjected to compressive creep loading were compared for several types of laminate layups. Unidirectional graphite/epoxy as well as multi-directional graphite/epoxy and graphite/PEEK layups were studied. Specimens with and without holes were tested. The specimens were subjected to compressive creep loading for a 10-hour period. In-plane displacements were measured using moire interferometry. A computer based data reduction scheme was developed which reduces the whole-field displacement fields obtained using moire to whole-field strain contour maps. Only slight viscoelastic response was observed in matrix-dominated laminates, except for one test in which catastrophic specimen failure occurred after a 16-hour period. In this case the specimen response was a complex combination of both viscoelastic and fracture mechanisms. No viscoelastic effects were observed for fiber-dominated laminates over the 10-hour creep time used. The experimental results for specimens with holes were compared with results obtained using a finite-element analysis. The comparison between experiment and theory was generally good. Overall strain distributions were very well predicted. The finite element analysis typically predicted slightly higher strain values at the edge of the hole, and slightly lower strain values at positions removed from the hole, than were observed experimentally. It is hypothesized that these discrepancies are due to nonlinear material behavior at the hole edge, which were not accounted for during the finite-element analysis.

Graesser, D. L.↗

Free volume manipulation of a 6FDA-HAB polyimide using a solid-state protection/deprotection strategy

We report tert-butoxycarbonyl (t-BOC) is a thermally labile moiety that can be used to protect hydroxyl groups on polymers. In this study, t-BOC was appended onto a polyimide consisting of 2,2'-bis-(3,4-dicarboxyphenyl) hexafluoropropane dianhydride (6FDA) and 3,3'-dihydroxy-4,4'-diamino-biphenyl (HAB), after which the polymer was formed into self-standing films. Solid-state thermal treatments were performed to systematically remove t-BOC moieties to alter the physical packing structure and concomitant gas transport properties of the polymer. Despite performing deprotection reactions well below the glass transition temperature of 6FDA-HAB (~300 °C), this free volume manipulation (FVM) approach produced only subtle differences in polymer density, fractional free volume, average free volume element size, and gas transport properties relative to the unprotected polymer. While these findings suggest that thermally removing covalently bound functional groups from polymer films can be used to manipulate free volume and gas transport performance for glassy polymers, more robust polymer systems than linear polyimides are required to preserve the nascent free volume architecture generated from this approach.

36 MATERIALS SCIENCE↗

Positive Role of Fluorine Impurity in Recovered LiNi 0.6 Co 0.2 Mn 0.2 O 2 Cathode Materials

Lithium-ion battery (LIB) recycling is considered as an important component to enable industry sustainability. A massive number of LIBs in portable electronics, electric vehicles, and grid storage will eventually end up as wastes, leading to serious economic and environmental problems. Hence, tremendous efforts have been made to improve the hydrometallurgical recycling process because it is the most promising option for handling end-of-life LIBs owing to its wide applicability, low cost, and high productivity. Despite these advantages, some extra elements (Al, Fe, C, F, and so forth) remain as impurities in the removal process and are retained in the solution, which is a great challenge to obtain high-quality cathode materials. In this work, the impacts caused by fluorine impurity on the LiNi 0.6 Co 0.2 Mn 0.2 O 2 (NCM622) cathode are intensively investigated via hydrometallurgical coprecipitation for the first time. Our results show that up to 1 at. % fluorine impurity brings a positive influence on the recovered material due to a higher Ni 2+ ratio on the surface of cathode particles. In addition, the presence of fluoride ions during coprecipitation could lead to the formation of holes in cathode particles, which improves the rate capability and cyclability dramatically. Compared to the virgin material, the capacity of the NCM622 material with 0.2 at. % fluorine impurity is boosted by ~8% (167.7 mA h/g) with a remarkable capacity retention of 98.0% after 100 cycles at 0.33 C. Besides, the cathode with 0.2 at. % fluorine impurity shows a far better rate performance, especially at high rates (~7% increased at 5 C) than that of virgin. Furthermore, these results convince that a low concentration of fluorine impurity is desirable in the hydrometallurgical recycling process. More importantly, this study offers implications in the design of high-performance NCM622 cathode materials via coprecipitation production with ion doping in the near future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing the ultracentral flow puzzle in hydrodynamic modeling of heavy-ion collisions

An outstanding problem in heavy-ion collisions is the inability for models to accurately describe ultra-central experimental flow data, despite that being precisely the regime where a hydrodynamic description should be most applicable. Here, we reassess the status of this puzzle by computing the flow in ultra-central collisions obtained from multiple recent Bayesian models that were tuned to various observables in different collision systems at typical centralities. While central data can now be described with better accuracy than in previous calculations, tension with experimental observation remains and worsens as one goes to ultra-central collisions. Tuning the model parameters cannot remove this tension without destroying the fit at other centralities. As such, new elements are likely needed in the standard modeling of heavy-ion collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

14 MeV Irradiation and Analysis of a 93% 239 Pu Target in Preparation for a F2019 FY22 Pu Campaign

In this work, we present the irradiation of a 93% 239 Pu with 14 MeV neutrons and subsequent analysis of the fission and activation products. The fully assembled target, a Pu metal bead encapsulated in Al, further encapsulated in welded stainless steel, was analyzed 22 times over more than 100 days using gamma emission analysis (GEA). Using the results from these analyses, R-values and fission yields for fission products were determined. To prepare for the FY22 Pu irradiation using the GODIVA critical assembly at NCERC, the irradiated Pu target was disassembled, dissolved, and separated using chemistry provided by LANL collaborators. This chemical separation was intended to remove the Pu from solution with little to no effect on the remaining elements. The chemistry was assessed to try to determine possible routes of fractionation of the sample and the fission products. The separation process used was successful for the bulk of the analyzed fission and activation products, as well as the added radiotracers. The final dissolved solution and separated fractions were analyzed by GEA looking at the remaining fission, activation and radiotracers and thermal ionization mass spectrometry analysis looking at the Pu isotopics.

14MeV↗

Loss of oxygen, silicon, sulfur, and potassium from the lunar regolith

The processes of formation and maturation of lunar soils lead to enrichments in the heavy stable isotopes of oxygen, silicon, sulfur, and potassium. The isotopic enrichment implies substantial losses of these elements from the moon. Vaporization by micrometeorite impact and by ion sputtering have removed at least 1% of the mass of the regolith. The losses of sulfur and potassium amount to at least 20-30% of their original abundance in the regolith.

Clayton, R. N.↗

Three dimensional mesh generation by triangulation of arbitrary point sets

A method for generating an unstructured mesh is described. The approach is quite general and joins an arbitrary set of points to produce a covering of three dimensional space by tetrahedra. After removing the tetrahedra that connect surface points, a mesh suitable for a finite element based flow solver is obtained. Details of the triangulation algorithm are provided together with an analysis of the algorithm efficiency and validity.

Baker, Timothy J.↗

Measurement and calibration of differential Mueller matrix of distributed targets

A rigorous method for calibrating polarimetric backscatter measurements of distributed targets is presented. By characterizing the radar distortions over the entire mainlobe of the antenna, the differential Mueller matrix is derived from the measured scattering matrices with a high degree of accuracy. It is shown that the radar distortions can be determined by measuring the polarimetric response of a metallic sphere over the main lobe of the antenna. Comparison of results obtained with the new algorithm with the results derived from the old calibration method show that the discrepancy between the two methods is less than 1 dB for the backscattering coefficients. The discrepancy is more drastic for the phase-difference statistics, indicating that removal of the radar distortions from the cross products of the scattering matrix elements cannot be accomplished with the traditional calibration methods.

Sarabandi, Kamal↗

Removal of Oxygen from Electronic Materials by Vapor-Phase Processes

Thermochemical analyses of equilibrium partial pressures over oxides with and without the presence of the respective element condensed phase, and hydrogen, chalcogens, hydrogen chalcogenides, and graphite are presented. Theoretical calculations are supplemented with experimental results on the rate of decomposition and/or sublimation/vaporization of the oxides under dynamic vacuum, and on the rate of reaction with hydrogen, graphite, and chalcogens. Procedures of removal of a number of oxides under different conditions are discussed.

Palosz, Witold↗

Fuel-Cell Reactant-Gas Purifier

Catalytic purifier removes oxygen from hydrogen feedlines just upstream of fuel-cell stack. Purifier consists of layer of platinum sandwiched between two sheets of porous polytetrafluoroethylene (PTFE). Platinum and PTFE elements stacked and ready for pressing. Purifier cut to size, pleated and inserted into convenient length of metal tubing. Purifier is 90 percent efficient in removing oxygen from gas stream containing 2 percent oxygen in hydrogen.

Mcbryar, H.↗

Accuracy limitations for composition analysis by XPS using relative peak intensities: LiF as an example

Although precision in XPS can be excellent, allowing small changes to be easily observed, obtaining accurate absolute elemental composition of a solid material from relative peak intensities is generally much more problematical, involving many factors: background removal; differing analysis depths at different photoelectron kinetic energies; possible angular distribution effects; calibration of the instrument transmission function, and variations of the distribution of the photoelectron intensity between “main” peaks (those usually used for analysis) and associated substructure following the main peak, as a function of the chemical bonding of the elements concerned. The last item, coupled with the use of photoionization cross-sections and/or relative sensitivity factors, is the major subject of this paper, though it is necessary to consider the other items also, using LiF as a test case. The results show that the above issues, which are relevant to differing degrees in most XPS analyses, present significant challenges to highly accurate XPS quantification.

Brundle, Christopher R.↗

Transient Analysis of a Magnetic Heat Pump

An experimental heat pump that uses a rare earth element as the refrigerant is modeled using NASTRAN. The refrigerant is a ferromagnetic metal whose temperature rises when a magnetic field is applied and falls when the magnetic field is removed. The heat pump is used as a refrigerator to remove heat from a reservoir and discharge it through a heat exchanger. In the NASTRAN model the components modeled are represented by one-dimensional ROD elements. Heat flow in the solids and fluid are analyzed. The problem is mildly nonlinear since the heat capacity of the refrigerant is temperature-dependent. One simulation run consists of a series of transient analyses, each representing one stroke of the heat pump. An auxiliary program was written that uses the results of one NASTRAN analysis to generate data for the next NASTRAN analysis.

Schroeder, E. A.↗