Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Conservation Measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Metabolism and heat dissipation during Apollo EVA periods

The extravehicular activity life support equipment, suit temperature control, metabolic rate measurement methods, and energy production are discussed. The Apollo crewmen were able to perform planned extravehicular activities and to extend them to the maximum time allowable without medical problems. The metabolic rates experienced during the lunar surface extravehicular activities were lower than conservative premission estimates. A manually controlled liquid cooling garment was effectively used to minimize fatigue and water loss from sweating during lunar surface extravehicular activities. Gas cooling was adequate during the short zero-g extravehicular activities performed from the command module. The prediction of EVA workloads became more reliable as inflight data was accumulated. The prediction of the average metabolic cost of an EVA was more reliable than the cost of an individual short-term task.

J.M. Waligora↗

The signature of parallel electric fields in a collisionless plasma

The presence of a parallel electric field in the magnetosphere should be apparent through its effect on particles. An analysis is made of particle trajectories in phase space for a steady state collisionless plasma. The analysis utilizes the concepts of distribution function, total energy, and magnetic moment because all three quantities are conserved in a steady state situation in the absence of collisions. Two methods are presented for using particle data to gain information on the potential distribution. The first method involves the use of measurements of both ion and electron distribution functions and invokes the principle of quasi-neutrality. The second method involves the observation of discontinuities in velocity space which can be interpreted in terms of the effect of the electric field on the apparent loss or source cone.

Whipple, E. C., Jr.↗

Dynamics of a class of vortex rings

The contour dynamics method is extended to vortex rings with vorticity varying linearly from the symmetry axis. An elliptic core model is also developed to explain some of the basic physics. Passage and collisions of two identical rings are studied focusing on core deformation, sound generation and stirring of fluid elements. With respect to core deformation, not only the strain rate but how rapidly it varies is important and accounts for greater susceptibility to vortex tearing than in two dimensions. For slow strain, as a passage interaction is completed and the strain relaxes, the cores return to their original shape while permanent deformations remain for rapidly varying strain. For collisions, if the strain changes slowly the core shapes migrate through a known family of two-dimensional steady vortex pairs up to the limiting member of the family. Thereafter energy conservation does not allow the cores to maintain a constant shape. For rapidly varying strain, core deformation is severe and a head-tail structure in good agreement with experiments is formed. With respect to sound generation, good agreement with the measured acoustic signal for colliding rings is obtained and a feature previously thought to be due to viscous effects is shown to be an effect of inviscid core deformation alone. For passage interactions, a component of high frequency is present. Evidence for the importance of this noise source in jet noise spectra is provided. Finally, processes of fluid engulfment and rejection for an unsteady vortex ring are studied using the stable and unstable manifolds. The unstable manifold shows excellent agreement with flow visualization experiments for leapfrogging rings suggesting that it may be a good tool for numerical flow visualization in other time periodic flows.

Shariff, Karim↗

Supersaturated Electrolyte Solutions: Theory and Experiment

Highly supersaturated electrolyte solutions can be prepared and studied employing an electrodynamic levitator trap (ELT) technique. The ELT technique involves containerless suspension of a microdroplet thus eliminating dust, dirt, and container walls which normally cause heterogeneous nucleation. This allows very high supersaturations to be achieved. A theoretical study of the experimental results obtained for the water activity in microdroplets of various electrolyte solutions is based on the development of the Cahn-Hilliard formalism for electrolyte solutions. In the approach suggested the metastable state for electrolyte solutions is described in terms of the conserved order parameter omega(r,t) associated with fluctuations of the mean solute concentration n(sub 0). Parameters of the corresponding Ginzburg-Landau free energy functional which defines the dynamics of metastable state relaxation are determined and expressed through the experimentally measured quantities. A correspondence of 96-99 % between theory and experiment for all solutions studied was achieved and allowed the determination of an analytical expression for the spinodal concentration n(sub spin), and its calculation for various electrolyte solutions at 298 K. The assumption that subcritical solute clusters consist of the electrically neutral Bjerrum pairs has allowed both analytical and numerical investigation of the number-size N(sub c) of nucleation monomers (aggregates of the Bjerrum pairs) which are elementary units of the solute critical clusters. This has also allowed estimations for the surface tension Alpha, and equilibrium bulk energy Beta per solute molecule in the nucleation monomers. The dependence of these properties on the temperature T and on the solute concentration n(sub 0) through the entire metastable zone (from saturation concentration n(sub sat) to spinodal n(sub spin) is examined. It has been demonstrated that there are the following asymptotics: N(sub c), = I at spinodal concentration and N(sub c) = infinity at saturation.

Izmailov, Alexander F.↗

Adaptive behavior and different thermal experiences of real people: A Bayesian neural network approach to thermal preference prediction and classification

Various observed and unquantifiable factors affect the thermal comfort of occupants in indoor environments and can lead to high uncertainty in the prediction and classification of their thermal preferences. The behavioral adaptation of occupants, by operating window systems for example, changes their thermal experience and expectations and therefore contributes to even higher prediction uncertainty. In this study, we applied a Bayesian neural network (BNN) algorithm to build a predictive model for occupant thermal preference using the ASHRAE Global Thermal Comfort Database II. The Bayesian method allows us to synthesize prior knowledge and available measurements into a unified modeling framework. It also offers a way to express and quantify uncertainty. Here we have performed a systematic study to test the efficiency and robustness of different BNN model configurations. In this study, the results show that the BNN model outperforms conventional thermal comfort models such as Predicted Mean Vote (PMV) and adaptive comfort model. The BNN model tends to produce more confident “prefer cooler” predictions with high possibility and low uncertainty. In contrast, the BNN model produces less certain predictions for “prefer no change” and “prefer warmer” across all occupants. Our findings suggest that linking occupants’ subjective evaluation measures and window opening/closing behavior to thermal comfort modeling effectively improves predictive performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Leading in Los Angeles: Demonstrating scalable emerging energy efficient technologies for integrated façade, lighting, and plug loads INTER System FLEXLAB Test Report

This report is a part of the California Energy Commission (Energy Commission) EPIC study Leading in Los Angeles: Demonstrating scalable emerging energy efficient technologies for integrated façade, lighting, and HVAC. The set of technologies are called the Integrated Technologies for Energy-efficient Retrofits (INTER) and are comprised of automated shading products and LED lighting systems with networked luminaire-level sensors and controls. In addition, the project will include control modifications and assessments of HVAC savings. This document includes the test plan and test results for the FLEXLAB® testing of the shading and lighting INTER system and related energy use impact. The test plan describes the test objectives and features, test cases, schedule, and measurements. The test results cover system performance in the lab; including lighting and HVAC energy, visual comfort, and thermal comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2022 Louisiana State University (Final Report)

LSU-IAC started in LSU’s College of Engineering in 2016 with funding from the U.S. Department of Energy’s IAC program. Due to the Covid 19 pandemic, the grant end date was extended from 8/31/2021 to 2/28/2022. In the 5-year performance period, LSU-IAC has conducted a total of 67 industrial assessments and trained a total number of 41 students. We have recommended 408 improvement measures with potential energy savings of 58,951,388 kWh and energy cost savings of $6,817,783 if implemented. Of the 41 students trained, 16 received DOE certificates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units

The heat pump rooftop units (RTUs) measure replaces gas furnace and electric resistance RTUs with high-efficiency heat pump rooftop units (HP-RTUs). The HP-RTUs are intended to be top-of-the line, including high-efficiency fans and heat pump systems. The fans are variable speed, allowing the HP-RTUs to operate as single-zone variable air volume systems. The heat pumps are also variable speed, allowing for high part load performance. All schedules in the existing RTUs are transferred to the new HP-RTUs for consistency. Furthermore, any energy efficiency features in the existing baseline RTUs such as energy recovery or economizers are also transferred to the new HP-RTUs for consistency. This measure is applicable to approximately 45% of the ComStock floor area. The HP-RTU measure demonstrates 10.3% total site energy savings (449 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Anisotropic parametrized post-Newtonian gravitational metric field

The anisotropic generalization of the parameterized post-Newtonian (PPN) gravitational metric field is made for the case of theories with energy and momentum conservation laws. Such an anisotropic metric field will generally result in two-tensor or bimetric theories of gravity in an anisotropic universe. New anisotropic 3 x 3 spatial PPN matrices are introduced into the general metric expansion. Earth gravimeter measurements strongly restrict some anisotropies, while anisotropic inertial and gravitational mass for celestial bodies result from other combinations of the PPN matrices.

Nordtvedt, K., Jr.↗

Alaska at the Crossroads of Migration: Space Based Ornithology

Understanding bird migration on a global scale is one of the most compelling and challenging problems of modern biology with major implications for human health and conservation biology. Revolutionary advances in remote sensing now provide us with near real-time measurements of atmospheric and land surface conditions at high spatial resolution over entire continents. We use spatially-explicit, individual based bird migration models driven by numerical weather prediction models of atmospheric conditions, dynamic habitat suitability maps derived from remotely sensed land surface conditions, biophysiological models, and biological field data to simulate migration routes, timing, energy budgets, and survival of individual birds and populations. Long-distance migratory birds travel annually between breeding grounds in Alaska and wintering grounds in Latin Amierica. Approximately 25% of these species are potential vectors of Avian Influenza. Alaska is at the crossroads of Asian and New World migratory flyways and is likely to be a point of introduction of Asian H5N1 AI into the western hemisphere. If/when an infected bird is detected, a pressing question will be where was this bird several days ago, and where is it likely to go after it was released from the survey site? Answers to such questions will increase effectiveness of AI surveillance and mitigation measures. From a conservation perspective, Alaska's diverse landscape provides breeding sites for many migrants, and climatic and land surface changes along migratory flyways in the western hemisphere may reduce bird survival and physical condition upon arrival at Alaskan breeding territories, success and migrant populations.

Deppe, Jill↗

Control of multi-agent systems: Results, open problems, and applications

The purpose of this review article is to present some recent results on the modeling and control of large systems of agents. We focus on particular applications where the agents are capable of independent actions instead of simply reacting to external forces. In the literature, such agents were referred to as autonomous, intelligent, self-propelled, greedy, and others. The main applications we have in mind are social systems (as opinion dynamics), pedestrians’ movements (also called crowd dynamics), animal groups, and vehicular traffic. We note that the last three examples include physical constraints; however, the agents are able to inject energy into the system, thus preventing the typical conservation of momentum and energy. In addition, the control problems posed by such systems are new and require innovative methods. We illustrate some ideas developed recently, including the use of sparse controls, limiting the total variation of controls, and defining new control problems for measures. After reviewing various approaches, we discuss some future research directions of potential interest. The latter encompasses both new types of equations and new types of limiting procedures to connect several scales at which a system can be represented. We conclude by illustrating a recent real-life experiment using autonomous vehicles on an open highway to smooth traffic waves. This opens the door to a new era of interventions to control real-time multi-agent systems and to increase the societal impact of such interventions guided by control research.

97 MATHEMATICS AND COMPUTING↗

Data-Driven Load Modeling and Forecasting of Residential Appliances

The expansion of residential demand side management programs and increased deployment of controllable loads require accurate appliance-level load modeling and forecasting. This paper proposes a conditional hidden semi-Markov model to describe the probabilistic nature of residential appliance demand. Model parameters are estimated directly from power consumption data using scalable statistical learning methods. We also propose an algorithm for short-term load forecasting as a key application for appliance-level load models. Case studies performed using granular sub-metered power measurements from various types of appliances demonstrate the effectiveness of the proposed load model for short-term prediction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Managing Army Plug Load Equipment Energy Use: Breakroom Appliances

Breakroom equipment is the third highest energy-consuming plug load category in Army buildings. In addition to the vending machine measures described separately, improved purchasing and control measures for breakroom appliances can save the Army more than 9 million kWh and $550K per year in the building types evaluated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units with Original Fuel Backup

This documentation focuses on a single end-use savings shape measure—heat pump rooftop units with supplemental heat that matches the original fuel type of the replaced system; if the existing system used electric resistance heating, the supplemental heating source is electric resistance. If it was a natural gas furnace, the supplemental system is modeled as natural gas. This is a modification to the heat pump rooftop unit with electric supplemental heat measure from the Commercial EUSS 2023 Release 1 dataset. This document will primarily discuss the supplemental heating change for the heat pump RTU measure. For a comprehensive overview of the fundamental modeling methodology and background of the heat pump RTU measure, including performance curves and other key assumptions, please review the documentation for the original heat pump rooftop unit with electric supplemental heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DIY Affordable Window Shading

This document shows how you can easily and affordably shade your windows to keep your home from getting too hot on sunny days. This phenomenon (what researchers call “solar heat gain”) can threaten occupant comfort and safety, especially during heatwaves. Still, many homes lack adequate protection. All of these solutions can be implemented inexpensively using common household items or items that can easily be purchased online. Additionally, you don’t need specialized tools or expertise to install them. Note that these are ideally temporary fixes, so households with sufficient means should still pursue permanent ones (e.g.,shades—preferably on the outside—or specialized windows or films). In their absence, the stopgap measures described below can help protect you and your loved ones during heatwaves and other exceptional events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: LED Lighting

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a timeseries profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - LED lighting. The LED lighting measure replaces interior lights with LEDs where applicable. The measure resulted in 1.25 TBtu energy savings across the building stock, with the majority of savings occurring in retail and warehouse buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement of C P Violation Observables in D + → K − K + π + Decays

A search for violation of the charge-parity ( C P ) symmetry in the D + → K − K + π + decay is presented, with proton-proton collision data corresponding to an integrated luminosity of 5.4 fb − 1 , collected at a center-of-mass energy of 13 TeV with the LHCb detector. A novel model-independent technique is used to compare the D + and D − phase-space distributions, with instrumental asymmetries subtracted using the D s + → K − K + π + decay as a control channel. The p value for the hypothesis of C P conservation is 8.1%. The C P asymmetry observables A C P | S ϕ π + = ( 0.95 ± 0.4 3 stat ± 0.2 6 syst ) × 10 − 3 and A C P | S K ¯ * 0 K + = ( − 0.26 ± 0.5 6 stat ± 0.1 8 syst ) × 10 − 3 are also measured. These results show no evidence of C P violation and represent the most sensitive search performed through the phase space of a multibody decay. © 2024 CERN, for the LHCb Collaboration 2024 CERN

Aaij, R. (ORCID:0000000305331952)↗

Comparative study on the overall energy performance between photovoltaic and Low-E insulated glass units

In this report a novel semi-transparent building integrated photovoltaic (BIPV) laminate was developed and introduced in this paper. It was produced by cutting standard mono-crystalline silicon solar cells into small strips and then making electrical connections between each strip before laminating the cells between two layers of glass. The overall energy performance and energy saving potential of the BIPV insulated glass unit (IGU) under real world conditions were identified through a side by side comparative study. Compared to the reference IGU, the BIPV IGU had lower solar heat gain coefficient (SHGC) but much higher U-factor. The average HVAC electricity saving of the BIPV IGU was about 10% relative to the reference IGU. Daylighting measurement and analysis were carried out to evaluate the trade-offs associated with the BIPV IGU between daylight, glare, and lighting energy use. The results indicated that the BIPV IGU is better than the reference IGU in reducing discomfort glare. However, if the most conservative viewpoint near the window is used for the assessment, a lower transmittance BIPV IGU is required to bring the overall discomfort levels below the perceptible level. Lastly, the net energy saving potential associated with the novel BIPV IGU was identified based on the power, thermal and daylighting performance. On average, the BIPV IGU saved 16.8% of the total electricity use of the room. Further studies and improvement on the energy conversion efficiency of solar cells, the optimal transmittance as well as the thermal properties would make this technology more energy-efficient and affordable.

14 SOLAR ENERGY↗