At least 271 records · Page 15

Recent progress in the development of liquid metal plasma facing components for magnetic fusion devices

One of the most critical challenges for future fusion reactors is to develop longevity plasma-facing components (PFCs) exposed to extremely high heat and neutron loads. As opposed to those employing solid metals, PFCs with flowing liquid metals (LM) have shown self-healing, heat removal and good impurity control capabilities, all essential to fusion devices. Recently, significant progress in LM-PFC development has been reported globally, with data from several magnetic fusion devices. These studies reveal that LM-PFCs can endure extreme heat fluxes while maintaining plasma compatibility. New design concepts have been proposed and numerically analyzed, advancing models for liquid PFCs in future reactors. Despite existing technical challenges, these developments suggest that LM-PFCs hold promise for future fusion applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Cr and Ni concentrations on resilience of cast Nb- alloyed heat resistant austenitic steels at extreme high temperatures

Austenitic Cr–Ni alloyed heat resistant steels with Nb additions are used for intensively thermo-mechanically loaded cast components working in extreme high temperature oxidizing environment. Their performance during static oxidation and transient thermo-mechanical loading was investigated to recommend an optimal cost-effective Cr/Ni composition of Nb-alloyed austenitic class steels. Here, the static oxidation and transient thermo-mechanical behavior of three austenitic steels with different Cr/Ni alloying levels were investigated and compared for variety of working conditions. Static oxidation was performed between 900 °C and 1000 °C in air for 400 h. The critical temperature which increases spallation during static oxidation was determined for each of the steel alloying levels. In addition, thermal cycling of a constrained specimen was done with varying upper cycling temperatures between 850 °C and 1000 °C. SEM and TEM analyses were supported by thermodynamic simulation of the phases precipitated in the metal matrix and the structure of formed oxide layers. These studies were used to determine the mechanisms of degradation of thermo-mechanically loaded Cr/Ni austenitic steels at extreme high temperatures. A recommendation for a cost-effective Cr/Ni alloying level for different working conditions was determined.

36 MATERIALS SCIENCE↗

A simplified method for thermal analysis of a cowl leading edge subject to intense local shock-wave-interference heating

Type IV shock wave interference heating on a blunt body causes extremely intense heating over a very localized region of the body. An analytical solution is presented to a heat transfer problem that approximates the shock wave interference heating of an engine cowl leading edge of the National Aero-Space Plane. The problem uses a simplified geometry to represent the leading edge. An analytical solution is developed that provides a means for approximating maximum temperature differences between the outer and inner surface temperatures of the leading edge. The solution is computationally efficient and, as a result, is well suited for conceptual and preliminary design or trade studies. Transient and steady state analyses are conducted, and results obtained from the analytical solution are compared with results of 2-D thermal finite element analyses over a wide range of design parameters. Isotropic materials as well as laminated composite materials are studied. Results of parametric studies are presented to indicate the effects of the thickness of the cowl leading edge and the width of the region heated by the shock wave interference on the thermal response of the leading edge.

Mcgowan, David M.↗

A Remarkable Auroral Event on Jupiter Observed in the Ultraviolet with the Hubble Space Telescope

Two sets of ultraviolet images of the Jovian north aurora were obtained with the Faint Object Camera on board the Hubble Space Telescope. The first series shows an intense discrete arc in near corotation with the planet. The maximum apparent molecular hydrogen emission rate corresponds to an electron precipitation of approximately 1 watt per square meter, which is about 30,000 times larger than the solar heating by extreme ultraviolet radiation. Such a particle heating rate of the auroral upper atmosphere of Jupiter should cause a large transient temperature increase and generate strong thermospheric winds. Twenty hours after initial observations, the discrete arc had decreased in brightness by more than one order of magnitude. The time scale and magnitude of the change in the ultraviolet aurora leads us to suggest that the discrete Jovian auroral precipitation is related to large-scale variations in the current system as is the case of for Earth's discrete aurorae.

Gerard, J. C.↗

Aerothermal Performance Envelopes for Hypersonic Small Radius Unswept Leading Edges and Nosetips

Small radius leading edges and nosetips were utilized to minimize wave drag in early hypersonic vehicle concepts until further analysis demonstrated that extreme aerothermodynamic heating would cause severe ablation or blunting of the available thermal protection system materials. Recent studies indicate that diboride composite materials are shape stable under extreme aerothermodynamic heating at ultra high temperatures. Aerothermal performance envelopes for sharp components made from these materials are presented in this work to demonstrate the effects of convective blocking, surface catalycity, surface emissivity, and rarefied flow effects on steady state operation at altitudes from sea level to 90 km. These components are capable of steady state operation at velocities up to 7.9 km/s at altitudes near 90 km.

Kolodziej, Paul↗

Externally Heated Diamond ANvil Cell Experimentation (EH-DANCE) for studying materials and processes under extreme conditions

Externally heated diamond anvil cells provide a stable and uniform thermal environment, making them a versatile device to simultaneously generate high-pressure and high-temperature conditions in various fields of research, such as condensed matter physics, materials science, chemistry, and geosciences. The present study features the Externally Heated Diamond ANvil Cell Experimentation (EH-DANCE) system, a versatile configuration consisting of a diamond anvil cell with a customized microheater for stable resistive heating, bidirectional pressure control facilitated by compression and decompression membranes, and a water-cooled enclosure suitable for vacuum and controlled atmospheres. This integrated system excels with its precise control of both pressure and temperature for mineral and materials science research under extreme conditions. Here, we showcase the capabilities of the system through its successful application in the investigation of the melting temperature and thermal equation of state of high-pressure ice-VII at temperatures up to 1400 K. The system was also used to measure the elastic properties of solid ice-VII and liquid H 2 O using Brillouin scattering and Raman spectra of carbonates using Raman spectroscopy, highlighting the potential of the EH-DANCE system in high-pressure research.

Instruments & Instrumentation↗

Multi-scenario Extreme Weather Simulator application to heat waves: Ko’olauloa community resilience hub

Heat waves are increasing in severity, duration, and frequency. The Multi-Scenario Extreme Weather Simulator (MEWS) models this using historical data, climate model outputs, and heat wave multipliers. In this study, MEWS is applied for planning of a community resilience hub in Hau'ula, Hawaii. The hub will have normal operations and resilience operations modes. Both these modes were modeled using EnergyPlus. The resilience operations mode includes cutting off air conditioning for many spaces to decrease power requirements during emergencies. Results were simulated for 300 future weather files generated by MEWS for 2020, 2040, 2060, and 2080. Shared socioeconomic pathways 2-4.5, 3-7.0 and 5-8.5 were used. The resilience operations mode results show two to six times increase of hours of exceedance beyond 32.2 °C from present conditions, depending on climate scenario and future year. The resulting decrease in thermal resilience enables an average decrease of energy use intensity of 26% with little sensitivity to climate change. The decreased thermal resilience predicted in the future is undesirable, but was not severe enough to require a more energy-intensive resilience mode. Instead, planning is needed to assure vulnerable individuals are given prioritized access to air-conditioned parts of the hub if worst-case heat waves occur.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Attribution of the Australian bushfire risk to anthropogenic climate change

Abstract. Disastrous bushfires during the last months of 2019 and January 2020 affected Australia, raising the question to what extent the risk of these fires was exacerbated by anthropogenic climate change. To answer the question for southeastern Australia, where fires were particularly severe, affecting people and ecosystems, we use a physically based index of fire weather, the Fire Weather Index; long-term observations of heat and drought; and 11 large ensembles of state-of-the-art climate models. We find large trends in the Fire Weather Index in the fifth-generation European Centre for Medium-Range Weather Forecasts (ECMWF) Atmospheric Reanalysis (ERA5) since 1979 and a smaller but significant increase by at least 30 % in the models. Therefore, we find that climate change has induced a higher weather-induced risk of such an extreme fire season. This trend is mainly driven by the increase of temperature extremes. In agreement with previous analyses we find that heat extremes have become more likely by at least a factor of 2 due to the long-term warming trend. However, current climate models overestimate variability and tend to underestimate the long-term trend in these extremes, so the true change in the likelihood of extreme heat could be larger, suggesting that the attribution of the increased fire weather risk is a conservative estimate. We do not find an attributable trend in either extreme annual drought or the driest month of the fire season, September–February. The observations, however, show a weak drying trend in the annual mean. For the 2019/20 season more than half of the July–December drought was driven by record excursions of the Indian Ocean Dipole and Southern Annular Mode, factors which are included in the analysis here. The study reveals the complexity of the 2019/20 bushfire event, with some but not all drivers showing an imprint of anthropogenic climate change. Finally, the study concludes with a qualitative review of various vulnerability and exposure factors that each play a role, along with the hazard in increasing or decreasing the overall impact of the bushfires.

van Oldenborgh, Geert Jan (ORCID:0000000268989535)↗

Microwave Regenerable Air Purification Device

The feasibility of using microwave power to thermally regenerate sorbents loaded with water vapor, CO2, and organic contaminants has been rigorously demonstrated. Sorbents challenged with air containing 0.5% CO2, 300 ppm acetone, 50 ppm trichloroethylene, and saturated with water vapor have been regenerated, singly and in combination. Microwave transmission, reflection, and phase shift has also been determined for a variety of sorbents over the frequency range between 1.3-2.7 GHz. This innovative technology offers the potential for significant energy savings in comparison to current resistive heating methods because energy is absorbed directly by the material to be heated. Conductive, convective and radiative losses are minimized. Extremely rapid heating is also possible, i.e., 1400 C in less than 60 seconds. Microwave powered thermal desorption is directly applicable to the needs of Advance Life Support in general, and of EVA in particular. Additionally, the applicability of two specific commercial applications arising from this technology have been demonstrated: the recovery for re-use of acetone (and similar solvents) from industrial waste streams using a carbon based molecular sieve; and the separation and destruction of trichloroethylene using ZSM-5 synthetic zeolite catalyst, a predominant halocarbon environmental contaminant. Based upon these results, Phase II development is strongly recommended.

Atwater, James E.↗

The 2010 Pakistan Flood and Russian Heat Wave: Teleconnection of Hydrometeorological Extremes

In this paper, preliminary results are presented showing that the two record-setting extreme events during 2010 summer (i.e., the Russian heat wave-wildfires and Pakistan flood) were physically connected. It is found that the Russian heat wave was associated with the development of an extraordinarily strong and prolonged extratropical atmospheric blocking event in association with the excitation of a large-scale atmospheric Rossby wave train spanning western Russia, Kazakhstan, and the northwestern China-Tibetan Plateau region. The southward penetration of upper-level vorticity perturbations in the leading trough of the Rossby wave was instrumental in triggering anomalously heavy rain events over northern Pakistan and vicinity in mid- to late July. Also shown are evidences that the Russian heat wave was amplified by a positive feedback through changes in surface energy fluxes between the atmospheric blocking pattern and an underlying extensive land region with below-normal soil moisture. The Pakistan heavy rain events were amplified and sustained by strong anomalous southeasterly flow along the Himalayan foothills and abundant moisture transport from the Bay of Bengal in connection with the northward propagation of the monsoonal intraseasonal oscillation.

Lau, William K. M.↗

Residential Natural Gas Demand Response Potential during Extreme Cold Events in Electricity-Gas Coupled Energy Systems

In regions where natural gas is used for both power generation and heating buildings, extreme cold weather events can place the electrical system under enormous stress and challenge the ability to meet residential heating and electric demands. Residential demand response has long been used in the power sector to curtail summer electric load, but these types of programs in general have not seen adoption in the natural gas sector during winter months. Natural gas demand response (NG-DR) has garnered interest given recent extreme cold weather events in the United States; however, the magnitude of savings and potential impacts—to occupants and energy markets—are not well understood. We present a case-study analysis of the technical potential for residential natural gas demand response in the northeast United States that utilizes diverse whole-building energy simulations and high-performance computing. Our results show that NG-DR applied to residential heating systems during extreme cold-weather conditions could reduce natural gas demand by 1–29% based on conservative and aggressive strategies, respectively. This indicates a potential to improve the resilience of gas and electric systems during stressful events, which we examine by estimating the impact on energy costs and electricity generation from natural gas. We also explore relationships between hourly indoor temperatures, demand response, and building envelope efficiency.

03 NATURAL GAS↗

Investigation of Loop Heat Pipe Survival and Restart After Extreme Cold Environment Exposure

NASA plans human exploration near the South Pole of the Moon, and other locations where the environment is extremely cold. This paper reports on the heat transfer performance of a loop heat pipe (LHP) exposed to extreme cold under the simulated reduced gravitational environment of the Moon. A common method of spacecraft thermal control is to use a LHP with ammonia working fluid. Typically, a small amount of heat is provided either by electrical heaters or by environmental design, such that the LHP condenser temperature never drops below the freezing point of ammonia. The concern is that a liquid-filled, frozen condenser would not restart, or that a thawing condenser would damage the tubing due to the expansion of ammonia upon thawing. This paper reports the results of an experimental investigation of a novel approach to avoid these problems. The LHP compensation chamber (CC) is conditioned such that all the ammonia liquid is removed from the condenser and the LHP is nonoperating. The condenser temperature is then reduced to below that of the ammonia freezing point. The LHP is then successfully restarted.

Golliher, Eric↗

Multi-Scenario Extreme Weather Simulator

The Multi-scenario Extreme Weather Simulator (MEWS) takes existing historical weather data and inserts trends and extreme events such as heat waves, hurricanes, extreme precipitation, or winter storms. The code includes functionality for projecting increasing frequency and duration of such events over a large range of statistically sampled realizations of the future. These weather files can then be used in building energy simulations through the Energy Plus software created by DOE. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525 SAND2021-8658 O

Villa, Daniel↗

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS↗

An asymptotic-preserving semi-Lagrangian algorithm for the anisotropic heat transport equation with arbitrary magnetic fields

Here, we extend the recently proposed semi-Lagrangian algorithm for the extremely anisotropic heat transport equation [Chacón et al., J. Comput. Phys ., 272 (2014)] to deal with arbitrary magnetic field topologies. The original scheme (which showed remarkable numerical properties) was valid for the so-called tokamak-ordering regime, in which the magnetic field magnitude was not allowed to vary much along field lines. The proposed extension maintains the attractive features of the original scheme (including the analytical Green's function, which is critical for tractability) with minor modifications, while allowing for completely general magnetic fields. The accuracy and generality of the approach are demonstrated by numerical experiment with an analytical manufactured solution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗